Skip to main content
Top
Published in: Abdominal Radiology 1/2013

01-02-2013

Dual-energy CT of the urinary tract

Authors: Ravi K. Kaza, Joel F. Platt, Alec J. Megibow

Published in: Abdominal Radiology | Issue 1/2013

Login to get access

Abstract

With the ability to provide structural- and material-specific information with single phase of image acquisition, dual-energy CT has several useful applications in urinary tract imaging such as evaluation of renal mass, CT urography, and characterization of urinary calculi. Although the underlying principle of dual-energy scanning is similar, there are several important differences in the currently available dual-energy scanners and the image processing algorithms used for these scanners. Knowledge of the principle of dual-energy data acquisition and image processing is essential to understand the advantages and limitations of dual-energy CT in urinary tract imaging.
Literature
1.
go back to reference Alvarez RE, Macovski A (1976) Energy-selective reconstructions in X-ray computerized tomography. Phys Med Biol 21(5):733–744PubMedCrossRef Alvarez RE, Macovski A (1976) Energy-selective reconstructions in X-ray computerized tomography. Phys Med Biol 21(5):733–744PubMedCrossRef
2.
go back to reference Hounsfield GN (1973) Computerized transverse axial scanning (tomography). 1. Description of system. Br J Radiol 46(552):1016–1022PubMedCrossRef Hounsfield GN (1973) Computerized transverse axial scanning (tomography). 1. Description of system. Br J Radiol 46(552):1016–1022PubMedCrossRef
3.
go back to reference Kalender WA, et al. (1986) Evaluation of a prototype dual-energy computed tomographic apparatus. I. Phantom studies. Med Phys 13(3):334–339PubMedCrossRef Kalender WA, et al. (1986) Evaluation of a prototype dual-energy computed tomographic apparatus. I. Phantom studies. Med Phys 13(3):334–339PubMedCrossRef
4.
go back to reference Fletcher JG, et al. (2009) Dual-energy and dual-source CT: is there a role in the abdomen and pelvis? Radiol Clin N Am 47(1):41–57PubMedCrossRef Fletcher JG, et al. (2009) Dual-energy and dual-source CT: is there a role in the abdomen and pelvis? Radiol Clin N Am 47(1):41–57PubMedCrossRef
5.
go back to reference Johnson TR, et al. (2007) Material differentiation by dual energy CT: initial experience. Eur Radiol 17(6):1510–1517PubMedCrossRef Johnson TR, et al. (2007) Material differentiation by dual energy CT: initial experience. Eur Radiol 17(6):1510–1517PubMedCrossRef
6.
go back to reference Brown CL, et al. (2009) Dual-energy CT iodine overlay technique for characterization of renal masses as cyst or solid: a phantom feasibility study. Eur Radiol 19(5):1289–1295PubMedCrossRef Brown CL, et al. (2009) Dual-energy CT iodine overlay technique for characterization of renal masses as cyst or solid: a phantom feasibility study. Eur Radiol 19(5):1289–1295PubMedCrossRef
7.
go back to reference Graser A, et al. (2009) Dual-energy CT in patients suspected of having renal masses: can virtual nonenhanced images replace true nonenhanced images? Radiology 252(2):433–440PubMedCrossRef Graser A, et al. (2009) Dual-energy CT in patients suspected of having renal masses: can virtual nonenhanced images replace true nonenhanced images? Radiology 252(2):433–440PubMedCrossRef
8.
go back to reference Primak AN, et al. (2007) Noninvasive differentiation of uric acid versus non-uric acid kidney stones using dual-energy CT. Acad Radiol 14(12):1441–1447PubMedCrossRef Primak AN, et al. (2007) Noninvasive differentiation of uric acid versus non-uric acid kidney stones using dual-energy CT. Acad Radiol 14(12):1441–1447PubMedCrossRef
9.
go back to reference Stolzmann P, et al. (2009) In vivo identification of uric acid stones with dual-energy CT: diagnostic performance evaluation in patients. Abdom Imaging 35:629–635PubMedCrossRef Stolzmann P, et al. (2009) In vivo identification of uric acid stones with dual-energy CT: diagnostic performance evaluation in patients. Abdom Imaging 35:629–635PubMedCrossRef
10.
go back to reference Stolzmann P, et al. (2010) Characterization of urinary stones with dual-energy CT: improved differentiation using a tin filter. Investig Radiol 45(1):1–6CrossRef Stolzmann P, et al. (2010) Characterization of urinary stones with dual-energy CT: improved differentiation using a tin filter. Investig Radiol 45(1):1–6CrossRef
11.
go back to reference Takahashi N, et al. (2010) Detectability of urinary stones on virtual nonenhanced images generated at pyelographic-phase dual-energy CT. Radiology 256(1):184–190PubMedCrossRef Takahashi N, et al. (2010) Detectability of urinary stones on virtual nonenhanced images generated at pyelographic-phase dual-energy CT. Radiology 256(1):184–190PubMedCrossRef
12.
go back to reference Graser A et al. (2010) Single-phase dual-energy CT allows for characterization of renal masses as benign or malignant. Investig Radiol 45(7):399-405 Graser A et al. (2010) Single-phase dual-energy CT allows for characterization of renal masses as benign or malignant. Investig Radiol 45(7):399-405
13.
go back to reference Karlo C, et al. (2011) Dual-energy CT with tin filter technology for the discrimination of renal lesion proxies containing blood, protein, and contrast-agent. An experimental phantom study. Eur Radiol 21(2):385–392PubMedCrossRef Karlo C, et al. (2011) Dual-energy CT with tin filter technology for the discrimination of renal lesion proxies containing blood, protein, and contrast-agent. An experimental phantom study. Eur Radiol 21(2):385–392PubMedCrossRef
14.
go back to reference Park J, et al. (2012) Dual-energy computed tomography applications in uroradiology. Curr Urol Rep 13(1):55–62PubMedCrossRef Park J, et al. (2012) Dual-energy computed tomography applications in uroradiology. Curr Urol Rep 13(1):55–62PubMedCrossRef
15.
go back to reference Silva AC, et al. (2011) Dual-energy (spectral) CT: applications in abdominal imaging. Radiographics 31(4):1031–1046 (discussion 1047–50)PubMedCrossRef Silva AC, et al. (2011) Dual-energy (spectral) CT: applications in abdominal imaging. Radiographics 31(4):1031–1046 (discussion 1047–50)PubMedCrossRef
16.
go back to reference Zhang D, Li X, Liu B (2011) Objective characterization of GE discovery CT750 HD scanner: gemstone spectral imaging mode. Med Phys 38(3):1178–1188PubMedCrossRef Zhang D, Li X, Liu B (2011) Objective characterization of GE discovery CT750 HD scanner: gemstone spectral imaging mode. Med Phys 38(3):1178–1188PubMedCrossRef
17.
go back to reference Li B, Yadava G, Hsieh J (2011) Quantification of head and body CTDI(VOL) of dual-energy x-ray CT with fast-kVp switching. Med Phys 38(5):2595–2601 Li B, Yadava G, Hsieh J (2011) Quantification of head and body CTDI(VOL) of dual-energy x-ray CT with fast-kVp switching. Med Phys 38(5):2595–2601
18.
go back to reference Hidas G, et al. (2010) Determination of renal stone composition with dual-energy CT: in vivo analysis and comparison with X-ray diffraction. Radiology 257(2):394–401PubMedCrossRef Hidas G, et al. (2010) Determination of renal stone composition with dual-energy CT: in vivo analysis and comparison with X-ray diffraction. Radiology 257(2):394–401PubMedCrossRef
19.
go back to reference Vrtiska TJ, et al. (2010) Genitourinary applications of dual-energy CT. AJR Am J Roentgenol 194(6):1434–1442PubMedCrossRef Vrtiska TJ, et al. (2010) Genitourinary applications of dual-energy CT. AJR Am J Roentgenol 194(6):1434–1442PubMedCrossRef
20.
go back to reference Zou YU, Silver MD (2008) Analysis of fast kV-switching in dual energy CT using a pre-reconstruction decomposition technique. In: Hsieh J, Samei E (eds) Proceedings of SPIE: Medical Imaging, vol 6913, pp 691313-1–12 Zou YU, Silver MD (2008) Analysis of fast kV-switching in dual energy CT using a pre-reconstruction decomposition technique. In: Hsieh J, Samei E (eds) Proceedings of SPIE: Medical Imaging, vol 6913, pp 691313-1–12
21.
go back to reference Goodsitt MM, Christodoulou EG, Larson SC (2011) Accuracies of the synthesized monochromatic CT numbers and effective atomic numbers obtained with a rapid kVp switching dual energy CT scanner. Med Phys 38(4):2222–2232PubMedCrossRef Goodsitt MM, Christodoulou EG, Larson SC (2011) Accuracies of the synthesized monochromatic CT numbers and effective atomic numbers obtained with a rapid kVp switching dual energy CT scanner. Med Phys 38(4):2222–2232PubMedCrossRef
22.
go back to reference Matsumoto K, et al. (2011) Virtual monochromatic spectral imaging with fast kilovoltage switching: improved image quality as compared with that obtained with conventional 120-kVp CT. Radiology 259(1):257–262PubMedCrossRef Matsumoto K, et al. (2011) Virtual monochromatic spectral imaging with fast kilovoltage switching: improved image quality as compared with that obtained with conventional 120-kVp CT. Radiology 259(1):257–262PubMedCrossRef
23.
go back to reference Maturen KE, et al. (2012) “Sweet spot” for endoleak detection: optimizing contrast to noise using low keV reconstructions from fast-switch kVp dual-energy CT. J Comput Assist Tomogr 36(1):83–87PubMedCrossRef Maturen KE, et al. (2012) “Sweet spot” for endoleak detection: optimizing contrast to noise using low keV reconstructions from fast-switch kVp dual-energy CT. J Comput Assist Tomogr 36(1):83–87PubMedCrossRef
24.
go back to reference Graser A, et al. (2009) Dual energy CT: preliminary observations and potential clinical applications in the abdomen. Eur Radiol 19(1):13–23PubMedCrossRef Graser A, et al. (2009) Dual energy CT: preliminary observations and potential clinical applications in the abdomen. Eur Radiol 19(1):13–23PubMedCrossRef
25.
go back to reference Maturen KE, et al. (2011) Aortic endograft surveillance: use of fast-switch kVp dual-energy computed tomography with virtual noncontrast imaging. J Comput Assist Tomogr 35(6):742–746PubMedCrossRef Maturen KE, et al. (2011) Aortic endograft surveillance: use of fast-switch kVp dual-energy computed tomography with virtual noncontrast imaging. J Comput Assist Tomogr 35(6):742–746PubMedCrossRef
26.
go back to reference Neville AM, et al. (2011) Detection of renal lesion enhancement with dual-energy multidetector CT. Radiology 259(1):173–183PubMedCrossRef Neville AM, et al. (2011) Detection of renal lesion enhancement with dual-energy multidetector CT. Radiology 259(1):173–183PubMedCrossRef
27.
go back to reference Kaza RK, et al. (2011) Distinguishing enhancing from nonenhancing renal lesions with fast kilovoltage-switching dual-energy CT. AJR Am J Roentgenol 197(6):1375–1381PubMedCrossRef Kaza RK, et al. (2011) Distinguishing enhancing from nonenhancing renal lesions with fast kilovoltage-switching dual-energy CT. AJR Am J Roentgenol 197(6):1375–1381PubMedCrossRef
28.
go back to reference Mendonca PRS et al. (2010) Multi-material decomposition of spectral CT images. In: Proceedings of SPIE, pp 76221W–76221W-9 Mendonca PRS et al. (2010) Multi-material decomposition of spectral CT images. In: Proceedings of SPIE, pp 76221W–76221W-9
29.
go back to reference Chandarana H, et al. (2011) Iodine quantification with dual-energy CT: phantom study and preliminary experience with renal masses. AJR Am J Roentgenol 196(6):W693–W700PubMedCrossRef Chandarana H, et al. (2011) Iodine quantification with dual-energy CT: phantom study and preliminary experience with renal masses. AJR Am J Roentgenol 196(6):W693–W700PubMedCrossRef
30.
31.
go back to reference Miller CM, et al. (2011) Effect of organ enhancement and habitus on estimation of unenhanced attenuation at contrast-enhanced dual-energy MDCT: concepts for individualized and organ-specific spectral iodine subtraction strategies. AJR Am J Roentgenol 196(5):W558–W564PubMedCrossRef Miller CM, et al. (2011) Effect of organ enhancement and habitus on estimation of unenhanced attenuation at contrast-enhanced dual-energy MDCT: concepts for individualized and organ-specific spectral iodine subtraction strategies. AJR Am J Roentgenol 196(5):W558–W564PubMedCrossRef
32.
go back to reference Zech CJ, Arndt N, Becker CR, Staehler M, Reiser MF, Johnson TR (2010) Dual-Energy CT for Detection of Malignancy in Patients with Polycystic Kidney Disease. Presented at Radiological Society of North America 2011 Scientific Assembly and Annual Meeting, November 28–December 3, Chicago, IL Zech CJ, Arndt N, Becker CR, Staehler M, Reiser MF, Johnson TR (2010) Dual-Energy CT for Detection of Malignancy in Patients with Polycystic Kidney Disease. Presented at Radiological Society of North America 2011 Scientific Assembly and Annual Meeting, November 28–December 3, Chicago, IL
33.
go back to reference Dillman JR, Caoili EM, Cohan RH (2007) Multi-detector CT urography: a one-stop renal and urinary tract imaging modality. Abdom Imaging 32(4):519–529PubMedCrossRef Dillman JR, Caoili EM, Cohan RH (2007) Multi-detector CT urography: a one-stop renal and urinary tract imaging modality. Abdom Imaging 32(4):519–529PubMedCrossRef
34.
go back to reference Takahashi N, et al. (2008) Dual-energy CT iodine-subtraction virtual unenhanced technique to detect urinary stones in an iodine-filled collecting system: a phantom study. AJR Am J Roentgenol 190(5):1169–1173PubMedCrossRef Takahashi N, et al. (2008) Dual-energy CT iodine-subtraction virtual unenhanced technique to detect urinary stones in an iodine-filled collecting system: a phantom study. AJR Am J Roentgenol 190(5):1169–1173PubMedCrossRef
35.
go back to reference Moon JW, Park BK, Kim CK, Park SY (2011) Evaluation of virtual unenhanced CT obtained from dualenergy CT urography for detecting urinary stones. Br J Radiol [Epub ahead of print] Moon JW, Park BK, Kim CK, Park SY (2011) Evaluation of virtual unenhanced CT obtained from dualenergy CT urography for detecting urinary stones. Br J Radiol [Epub ahead of print]
36.
go back to reference Mangold S, Fenchel MC, Vuust M, Claussen CD, Heuschmid M, Krauss B, Ketelsen D, Tsiflikas I (2010) Virtual Nonenhanced Dual-Energy CT Urography with Tin Filter Technology: Detection of Urinary Calculi in Vivo in Comparison to True Nonenhanced CT Urography. Presented at Radiological Society of North America 2011 Scientific Assembly and Annual Meeting, November 28–December 3, Chicago, IL Mangold S, Fenchel MC, Vuust M, Claussen CD, Heuschmid M, Krauss B, Ketelsen D, Tsiflikas I (2010) Virtual Nonenhanced Dual-Energy CT Urography with Tin Filter Technology: Detection of Urinary Calculi in Vivo in Comparison to True Nonenhanced CT Urography. Presented at Radiological Society of North America 2011 Scientific Assembly and Annual Meeting, November 28–December 3, Chicago, IL
37.
go back to reference Wells SA, Caoili EM, Cohan RH, Kaza RK, Ellis JH, Platt JF (2010) The role of dual-energy CT (DECT) in CT urography (CTU). Presented at Radiological Society of North America 2010 Scientific Assembly and Annual Meeting; November 28–December 3, Chicago, IL Wells SA, Caoili EM, Cohan RH, Kaza RK, Ellis JH, Platt JF (2010) The role of dual-energy CT (DECT) in CT urography (CTU). Presented at Radiological Society of North America 2010 Scientific Assembly and Annual Meeting; November 28–December 3, Chicago, IL
38.
go back to reference Wang J, Qu M, Leng S, McCollough CH (2010) Differentiation of uric acid versus non-uric acid kidney stones in the presence of iodine using dual-energy CT. In: Samei E, Pelc NJ (eds) Proceedings of SPIE: Medical Imaging, vol 7622, pp 76223O–76223O-9 Wang J, Qu M, Leng S, McCollough CH (2010) Differentiation of uric acid versus non-uric acid kidney stones in the presence of iodine using dual-energy CT. In: Samei E, Pelc NJ (eds) Proceedings of SPIE: Medical Imaging, vol 7622, pp 76223O–76223O-9
39.
go back to reference Kambadakone AR, et al. (2010) New and evolving concepts in the imaging and management of urolithiasis: urologists’ perspective. Radiographics 30(3):603–623PubMedCrossRef Kambadakone AR, et al. (2010) New and evolving concepts in the imaging and management of urolithiasis: urologists’ perspective. Radiographics 30(3):603–623PubMedCrossRef
40.
go back to reference Eliahou R, et al. (2010) Determination of renal stone composition with dual-energy computed tomography: an emerging application. Semin Ultrasound CT MR 31(4):315–320PubMedCrossRef Eliahou R, et al. (2010) Determination of renal stone composition with dual-energy computed tomography: an emerging application. Semin Ultrasound CT MR 31(4):315–320PubMedCrossRef
41.
go back to reference Motley G, et al. (2001) Hounsfield unit density in the determination of urinary stone composition. Urology 58(2):170–173PubMedCrossRef Motley G, et al. (2001) Hounsfield unit density in the determination of urinary stone composition. Urology 58(2):170–173PubMedCrossRef
42.
go back to reference Manglaviti G, et al. (2011) In vivo evaluation of the chemical composition of urinary stones using dual-energy CT. AJR Am J Roentgenol 197(1):W76–W83PubMedCrossRef Manglaviti G, et al. (2011) In vivo evaluation of the chemical composition of urinary stones using dual-energy CT. AJR Am J Roentgenol 197(1):W76–W83PubMedCrossRef
43.
go back to reference Qu M, Giselle J, Ramirez Giraldo J, Vrtiska TJ, Lieske JC, McCollough CH, Krambeck A, Liu Y (2011) In vivo discrimination of nonuric acid kidney stone types. Presented at Radiological Society of North America 2011 Scientific Assembly and Annual Meeting, November 28–December 3, Chicago, IL Qu M, Giselle J, Ramirez Giraldo J, Vrtiska TJ, Lieske JC, McCollough CH, Krambeck A, Liu Y (2011) In vivo discrimination of nonuric acid kidney stone types. Presented at Radiological Society of North America 2011 Scientific Assembly and Annual Meeting, November 28–December 3, Chicago, IL
44.
go back to reference Qu M, et al. (2011) Dual-energy dual-source CT with additional spectral filtration can improve the differentiation of non-uric acid renal stones: an ex vivo phantom study. AJR Am J Roentgenol 196(6):1279–1287PubMedCrossRef Qu M, et al. (2011) Dual-energy dual-source CT with additional spectral filtration can improve the differentiation of non-uric acid renal stones: an ex vivo phantom study. AJR Am J Roentgenol 196(6):1279–1287PubMedCrossRef
45.
go back to reference Joshi M, Langan D, Sahani DS, et al. (2010) Effective atomic number accuracy for kidney stone characterization using spectral CT. In: Samei E, Pelc NJ (eds) Proceedings of SPIE: Medical Imaging 2010, vol 7622, pp 76223K-1-12 Joshi M, Langan D, Sahani DS, et al. (2010) Effective atomic number accuracy for kidney stone characterization using spectral CT. In: Samei E, Pelc NJ (eds) Proceedings of SPIE: Medical Imaging 2010, vol 7622, pp 76223K-1-12
46.
go back to reference Kulkarni N, Pinho D, Desai GS, Eisner BH, Doyle M, Sahani DV (2011) Kidney stone detection and characterization on dual-energy CT under annual background radiation dose. Presented at Radiological Society of North America 2011 Scientific Assembly and Annual Meeting, November 28–December 3, Chicago, IL Kulkarni N, Pinho D, Desai GS, Eisner BH, Doyle M, Sahani DV (2011) Kidney stone detection and characterization on dual-energy CT under annual background radiation dose. Presented at Radiological Society of North America 2011 Scientific Assembly and Annual Meeting, November 28–December 3, Chicago, IL
47.
go back to reference Thomas C, et al. (2009) Dual-energy CT for the characterization of urinary calculi: in vitro and in vivo evaluation of a low-dose scanning protocol. Eur Radiol 19(6):1553–1559PubMedCrossRef Thomas C, et al. (2009) Dual-energy CT for the characterization of urinary calculi: in vitro and in vivo evaluation of a low-dose scanning protocol. Eur Radiol 19(6):1553–1559PubMedCrossRef
48.
go back to reference Yu L, et al. (2009) Image quality optimization and evaluation of linearly mixed images in dual-source, dual-energy CT. Med Phys 36(3):1019–1024PubMedCrossRef Yu L, et al. (2009) Image quality optimization and evaluation of linearly mixed images in dual-source, dual-energy CT. Med Phys 36(3):1019–1024PubMedCrossRef
49.
go back to reference Yadava GK, Chandra N, Hsieh J (2011) Relative dose in dual energy fast-kVp switching and conventional kVp imaging: spatial frequency dependent noise characteristics and low contrast imaging. In: Pelc NJ, Samei E, Nishikawa RM (eds) Proceedings of SPIE: Medical Imaging, vol 7961, pp 79613R-1–7 Yadava GK, Chandra N, Hsieh J (2011) Relative dose in dual energy fast-kVp switching and conventional kVp imaging: spatial frequency dependent noise characteristics and low contrast imaging. In: Pelc NJ, Samei E, Nishikawa RM (eds) Proceedings of SPIE: Medical Imaging, vol 7961, pp 79613R-1–7
50.
go back to reference Ng J, Chandarana H, Megibow AJ (2012) Decreased radiation dose in abdominal-pelvic MDCT using dual source dual energy imaging: quantitative comparison in 84 patients. To be presented at 2012 American Roentegen Ray Society Annual Meeting, Vancouver, CA Ng J, Chandarana H, Megibow AJ (2012) Decreased radiation dose in abdominal-pelvic MDCT using dual source dual energy imaging: quantitative comparison in 84 patients. To be presented at 2012 American Roentegen Ray Society Annual Meeting, Vancouver, CA
51.
go back to reference Hara AK, et al. (2009) Iterative reconstruction technique for reducing body radiation dose at CT: feasibility study. AJR Am J Roentgenol 193(3):764–771PubMedCrossRef Hara AK, et al. (2009) Iterative reconstruction technique for reducing body radiation dose at CT: feasibility study. AJR Am J Roentgenol 193(3):764–771PubMedCrossRef
52.
go back to reference Schindera ST, et al. (2011) Iterative reconstruction algorithm for abdominal multidetector CT at different tube voltages: assessment of diagnostic accuracy, image quality, and radiation dose in a phantom study. Radiology 260(2):454–462PubMedCrossRef Schindera ST, et al. (2011) Iterative reconstruction algorithm for abdominal multidetector CT at different tube voltages: assessment of diagnostic accuracy, image quality, and radiation dose in a phantom study. Radiology 260(2):454–462PubMedCrossRef
53.
go back to reference Leng S, et al. (2011) Noise reduction in spectral CT: reducing dose and breaking the trade-off between image noise and energy bin selection. Med Phys 38(9):4946–4957PubMedCrossRef Leng S, et al. (2011) Noise reduction in spectral CT: reducing dose and breaking the trade-off between image noise and energy bin selection. Med Phys 38(9):4946–4957PubMedCrossRef
54.
go back to reference Szczykutowicz TP, Chen G-H (2011) Radiation dose reduction in dual-energy CT using PICCS reconstruction. Presented at Radiological Society of North America 2011 Scientific Assembly and Annual Meeting; November 28–December 3, Chicago, IL Szczykutowicz TP, Chen G-H (2011) Radiation dose reduction in dual-energy CT using PICCS reconstruction. Presented at Radiological Society of North America 2011 Scientific Assembly and Annual Meeting; November 28–December 3, Chicago, IL
Metadata
Title
Dual-energy CT of the urinary tract
Authors
Ravi K. Kaza
Joel F. Platt
Alec J. Megibow
Publication date
01-02-2013
Publisher
Springer-Verlag
Published in
Abdominal Radiology / Issue 1/2013
Print ISSN: 2366-004X
Electronic ISSN: 2366-0058
DOI
https://doi.org/10.1007/s00261-012-9901-7

Other articles of this Issue 1/2013

Abdominal Radiology 1/2013 Go to the issue
Live Webinar | 27-06-2024 | 18:00 (CEST)

Keynote webinar | Spotlight on medication adherence

Live: Thursday 27th June 2024, 18:00-19:30 (CEST)

WHO estimates that half of all patients worldwide are non-adherent to their prescribed medication. The consequences of poor adherence can be catastrophic, on both the individual and population level.

Join our expert panel to discover why you need to understand the drivers of non-adherence in your patients, and how you can optimize medication adherence in your clinics to drastically improve patient outcomes.

Prof. Kevin Dolgin
Prof. Florian Limbourg
Prof. Anoop Chauhan
Developed by: Springer Medicine
Obesity Clinical Trial Summary

At a glance: The STEP trials

A round-up of the STEP phase 3 clinical trials evaluating semaglutide for weight loss in people with overweight or obesity.

Developed by: Springer Medicine

Highlights from the ACC 2024 Congress

Year in Review: Pediatric cardiology

Watch Dr. Anne Marie Valente present the last year's highlights in pediatric and congenital heart disease in the official ACC.24 Year in Review session.

Year in Review: Pulmonary vascular disease

The last year's highlights in pulmonary vascular disease are presented by Dr. Jane Leopold in this official video from ACC.24.

Year in Review: Valvular heart disease

Watch Prof. William Zoghbi present the last year's highlights in valvular heart disease from the official ACC.24 Year in Review session.

Year in Review: Heart failure and cardiomyopathies

Watch this official video from ACC.24. Dr. Biykem Bozkurt discusses last year's major advances in heart failure and cardiomyopathies.