Skip to main content
Top
Published in: Abdominal Radiology 5/2010

01-10-2010

Detection of colo-rectal liver metastases: prospective comparison of contrast enhanced US, multidetector CT, PET/CT, and 1.5 Tesla MR with extracellular and reticulo-endothelial cell specific contrast agents

Authors: Pier Paolo Mainenti, Marcello Mancini, Ciro Mainolfi, Luigi Camera, Simone Maurea, Antonietta Manchia, Michela Tanga, Francesco Persico, Pietro Addeo, Dario D’Antonio, Antonio Speranza, Luigi Bucci, Giovanni Persico, Leonardo Pace, Marco Salvatore

Published in: Abdominal Radiology | Issue 5/2010

Login to get access

Abstract

Background

To compare contrast-enhanced US (CE-US), multidetector-CT (MDCT), 1.5 Tesla MR with extra-cellular (Gd-enhanced) and intracellular (SPIO-enhanced) contrast agents and PET/CT, in the detection of hepatic metastases from colorectal cancer.

Materials and methods

A total of 34 patients with colo-rectal adenocarcinoma underwent preoperatively CE-US, MDCT, Gd- and SPIO-enhanced MR imaging (MRI), and PET/CT. Each set of images was reviewed independently by two blinded observers. The ROC method was used to analyze the results, which were correlated with surgical findings, intraoperative US, histopathology, and MDCT follow-up.

Results

A total of 57 hepatic lesions were identified: 11 hemangiomas, 29 cysts, 1 focal fatty liver, 16 metastases (dimensional distribution: 5/16 < 5 mm; 3/16 between 5 mm and <10 mm; 8/16 ≥ 10 mm). Six of 34 patients were classified as positive for the presence of at least one metastasis. Considering all the metastases and those ≥10 mm, ROC areas showed no significant differences between Gd- and SPIO-enhanced MRI, which performed significantly better than the other modalities (P < 0.05). Considering the lesions <10 mm, ROC areas showed no significant differences between all modalities; however MRI presented a trend to perform better than the other techniques. Considering the patients, ROC areas showed no significant differences between all the modalities; however PET/CT seemed to perform better than the others.

Conclusions

Gd- and SPIO-enhanced MRI seem to be the most accurate modality in the identification of liver metastases from colo-rectal carcinoma. PET/CT shows a trend to perform better than the other modalities in the identification of patients with liver metastases.
Literature
1.
go back to reference Fong Y, Cohen AM, Fortner JG, et al. Liver resection for colorectal metastases. J Clin Oncol 1997; 15: 938-946.PubMed Fong Y, Cohen AM, Fortner JG, et al. Liver resection for colorectal metastases. J Clin Oncol 1997; 15: 938-946.PubMed
2.
go back to reference Nakamura S, Suzuky S, Baba S. Resection of liver metastases of colorectal carcinoma. World J Surg 1997; 21: 741-747.CrossRefPubMed Nakamura S, Suzuky S, Baba S. Resection of liver metastases of colorectal carcinoma. World J Surg 1997; 21: 741-747.CrossRefPubMed
3.
go back to reference Lehnert T, Knabel HP, Duck M, et al. Sequential hepatic and pulmonary resections for metastatic colorectal cancer. Br J Surg 1999; 86: 241-243.CrossRefPubMed Lehnert T, Knabel HP, Duck M, et al. Sequential hepatic and pulmonary resections for metastatic colorectal cancer. Br J Surg 1999; 86: 241-243.CrossRefPubMed
4.
go back to reference Tanada M, Saeki T, Takashima S, et al. Intrahepatic arterial infusion chemotherapy for the colon cancer patients with liver metastases: a comparison of arterial embolization chemotherapy versus continuous arterial infusion chemotherapy. Gan to Kagaku Ryoho 1996; 23: 1440-1442.PubMed Tanada M, Saeki T, Takashima S, et al. Intrahepatic arterial infusion chemotherapy for the colon cancer patients with liver metastases: a comparison of arterial embolization chemotherapy versus continuous arterial infusion chemotherapy. Gan to Kagaku Ryoho 1996; 23: 1440-1442.PubMed
5.
go back to reference Dodd GD III, Soulen MC, Kane Rane, et al. Minimally Invasive treatment of malignant hepatic tumors: at the threshold of a major break through. Radiographics 2000; 20: 9-27.PubMed Dodd GD III, Soulen MC, Kane Rane, et al. Minimally Invasive treatment of malignant hepatic tumors: at the threshold of a major break through. Radiographics 2000; 20: 9-27.PubMed
6.
go back to reference Ruers T, Bleichrodt RP. Treatment of liver metastases, an updater on the possibilities and results. Eur J Cancer 2002; 38: 1023-1033.CrossRefPubMed Ruers T, Bleichrodt RP. Treatment of liver metastases, an updater on the possibilities and results. Eur J Cancer 2002; 38: 1023-1033.CrossRefPubMed
7.
go back to reference Kinkel K, Lu Y, Both M, Warren RS, Thoeni RF. Detection of Hepatic Metastases from Cancer of the Gastrointestinal tract by using non invasive imaging methods (US, CT, MR Imaging, PET): a meta-analysis. Radiology 2002; 224: 748-756.CrossRefPubMed Kinkel K, Lu Y, Both M, Warren RS, Thoeni RF. Detection of Hepatic Metastases from Cancer of the Gastrointestinal tract by using non invasive imaging methods (US, CT, MR Imaging, PET): a meta-analysis. Radiology 2002; 224: 748-756.CrossRefPubMed
8.
go back to reference Bipat S, van Leeuwen MS, Comans EFI, et al. Colorectal liver metastases: CT, MR imaging, and PET for diagnosis-Meta-analysis. Radiology 2005; 237: 123-131.CrossRefPubMed Bipat S, van Leeuwen MS, Comans EFI, et al. Colorectal liver metastases: CT, MR imaging, and PET for diagnosis-Meta-analysis. Radiology 2005; 237: 123-131.CrossRefPubMed
9.
go back to reference Couinaud C. Controlled hepatectomies and exposure of the intrahepatic bile ducts. Paris, France: C. Couinaud, 1981: 9-27. Couinaud C. Controlled hepatectomies and exposure of the intrahepatic bile ducts. Paris, France: C. Couinaud, 1981: 9-27.
10.
go back to reference Wernecke K, Rummeny E, Bongartz G, et al. Detection of hepatic masses in patients with carcinoma: comparative sensitivities of sonography, CT, and MR imaging. Am J Roentgenol 1991; 157: 731-739. Wernecke K, Rummeny E, Bongartz G, et al. Detection of hepatic masses in patients with carcinoma: comparative sensitivities of sonography, CT, and MR imaging. Am J Roentgenol 1991; 157: 731-739.
11.
go back to reference Glover C, Douse P, Kane P, et al. Accuracy of investigations for asymptomatic colorectal liver metastases. Dis Colon Rectum 2002; 45: 476-484.CrossRefPubMed Glover C, Douse P, Kane P, et al. Accuracy of investigations for asymptomatic colorectal liver metastases. Dis Colon Rectum 2002; 45: 476-484.CrossRefPubMed
12.
go back to reference Clarke MP, Kane RA, Steele G Jr, et al. Prospective comparison of preoperative imaging and intraoperative ultrasonography in the detection of liver tumors. Surgery 1989; 106: 849-855.PubMed Clarke MP, Kane RA, Steele G Jr, et al. Prospective comparison of preoperative imaging and intraoperative ultrasonography in the detection of liver tumors. Surgery 1989; 106: 849-855.PubMed
13.
go back to reference Ohlsson B, Tranberg KG, Lundstedt C, et al. Detection of hepatic metastases in colorectal cancer: a prospective study of laboratory and imaging methods. Eur J Surg 1993; 159: 275-281.PubMed Ohlsson B, Tranberg KG, Lundstedt C, et al. Detection of hepatic metastases in colorectal cancer: a prospective study of laboratory and imaging methods. Eur J Surg 1993; 159: 275-281.PubMed
14.
go back to reference Albrecht T, Hoffmann CW, Schmitz SA, et al. Phase-inversion sonography during the liver-specific late phase of contrast enhancement: improved detection of liver metastases. Am J Roentgenol 2001; 176: 1191-1198. Albrecht T, Hoffmann CW, Schmitz SA, et al. Phase-inversion sonography during the liver-specific late phase of contrast enhancement: improved detection of liver metastases. Am J Roentgenol 2001; 176: 1191-1198.
15.
go back to reference Albrecht T, Blomley MJ, Burns PN, et al. Improved detection of hepatic metastases with pulse-inversion US during the liver-specific phase of SHU 508A: multicenter study. Radiology 2003; 227: 361-370.CrossRefPubMed Albrecht T, Blomley MJ, Burns PN, et al. Improved detection of hepatic metastases with pulse-inversion US during the liver-specific phase of SHU 508A: multicenter study. Radiology 2003; 227: 361-370.CrossRefPubMed
16.
go back to reference Esteban JM, Molla MA, Tomas C, Maldonado L. Improved detection of liver metastases with contrast-enhanced wideband harmonic imaging: comparison with CT findings. Eur J Ultrasound 2002; 15: 119-126.CrossRefPubMed Esteban JM, Molla MA, Tomas C, Maldonado L. Improved detection of liver metastases with contrast-enhanced wideband harmonic imaging: comparison with CT findings. Eur J Ultrasound 2002; 15: 119-126.CrossRefPubMed
17.
go back to reference Quaia E, D’Onofrio M, Palumbo A, Rossi S, Bruni S, Cova M. Comparison of contrast-enhanced ultrasonography versus baseline ultrasound and contrast-enhanced computed tomography in metastatic disease of the liver: diagnostic performance and confidence. Eur Radiol 2006; 16: 1599-1609.CrossRefPubMed Quaia E, D’Onofrio M, Palumbo A, Rossi S, Bruni S, Cova M. Comparison of contrast-enhanced ultrasonography versus baseline ultrasound and contrast-enhanced computed tomography in metastatic disease of the liver: diagnostic performance and confidence. Eur Radiol 2006; 16: 1599-1609.CrossRefPubMed
18.
go back to reference Dalla Palma L, Bertolotto M, Quaia E, Locatelli M. Detection of liver metastases with pulse inversion harmonic imaging: preliminary results. Eur Radiol 1999; 9 (Suppl. 3): S382-387.CrossRefPubMed Dalla Palma L, Bertolotto M, Quaia E, Locatelli M. Detection of liver metastases with pulse inversion harmonic imaging: preliminary results. Eur Radiol 1999; 9 (Suppl. 3): S382-387.CrossRefPubMed
19.
go back to reference Celli N, Gaiani S, Piscaglia F, et al. Characterization of liver lesions by real-time contrast-enhanced ultrasonography. Eur J Gastroenterol Hepatol 2007; 19: 3-14.CrossRefPubMed Celli N, Gaiani S, Piscaglia F, et al. Characterization of liver lesions by real-time contrast-enhanced ultrasonography. Eur J Gastroenterol Hepatol 2007; 19: 3-14.CrossRefPubMed
20.
go back to reference Larsen LP, Rosenkilde M, et al. The value of contrast enhanced ultrasonography in detection of liver metastases from colorectal cancer: A prospective double-blinded study. European Journal of Radiology 2007; 62: 302-307.CrossRefPubMed Larsen LP, Rosenkilde M, et al. The value of contrast enhanced ultrasonography in detection of liver metastases from colorectal cancer: A prospective double-blinded study. European Journal of Radiology 2007; 62: 302-307.CrossRefPubMed
22.
go back to reference Weg N, Scheer MR, Gabor MP. Liver lesions: improved detection with dual-detector-array CT and routine 2.5-mm thin collimation. Radiology 1998; 209: 417-426.PubMed Weg N, Scheer MR, Gabor MP. Liver lesions: improved detection with dual-detector-array CT and routine 2.5-mm thin collimation. Radiology 1998; 209: 417-426.PubMed
23.
go back to reference Kawata S, Murakami T, Kim T, et al. Multidetector CT: diagnostic impact of slice thickness on detection of hypervascular hepatocellular carcinoma. Am J Roentgenol 2002; 179: 61-66. Kawata S, Murakami T, Kim T, et al. Multidetector CT: diagnostic impact of slice thickness on detection of hypervascular hepatocellular carcinoma. Am J Roentgenol 2002; 179: 61-66.
24.
go back to reference Haider MA, Amitai MM, Rappaport DC et al. Multidetector row helical CT in preoperative assessment of small (<1.5 cm) liver metastases: is thinner collimation better?. Radiology 2002; 225: 137-142.CrossRefPubMed Haider MA, Amitai MM, Rappaport DC et al. Multidetector row helical CT in preoperative assessment of small (<1.5 cm) liver metastases: is thinner collimation better?. Radiology 2002; 225: 137-142.CrossRefPubMed
25.
go back to reference Abdelmoumene A, Chevallier P, Chalaron M, et al. Detection of liver metastases under 2 cm: comparison of different acquisition protocols in four row multidetector-CT (MDCT). Eur Radiol 2005; 15: 1881-1887.CrossRefPubMed Abdelmoumene A, Chevallier P, Chalaron M, et al. Detection of liver metastases under 2 cm: comparison of different acquisition protocols in four row multidetector-CT (MDCT). Eur Radiol 2005; 15: 1881-1887.CrossRefPubMed
26.
go back to reference Scott DJ, Guthrie JA, Arnold P, et al. Dual phase helical CT versus portal venous phase CT for the detection of colorectal liver metastases; correlation with intra-operative sonography, surgical and pathological finings. Clin Radiol 2001; 56: 235-42.CrossRefPubMed Scott DJ, Guthrie JA, Arnold P, et al. Dual phase helical CT versus portal venous phase CT for the detection of colorectal liver metastases; correlation with intra-operative sonography, surgical and pathological finings. Clin Radiol 2001; 56: 235-42.CrossRefPubMed
27.
go back to reference Valls C, Andıa E, Sanchez A, et al. Hepatic metastases from colorectal cancer: preoperative assessment of resectability with helical CT. Radiology 2001; 218: 55-60.PubMed Valls C, Andıa E, Sanchez A, et al. Hepatic metastases from colorectal cancer: preoperative assessment of resectability with helical CT. Radiology 2001; 218: 55-60.PubMed
28.
go back to reference Valls C, Lopez E, Guma A, et al. Helical CT versus CT arterial portography in the detection of hepatic metastasis of colorectal carcinoma. Am J Roentgenol 1998; 170: 1341-1347. Valls C, Lopez E, Guma A, et al. Helical CT versus CT arterial portography in the detection of hepatic metastasis of colorectal carcinoma. Am J Roentgenol 1998; 170: 1341-1347.
29.
go back to reference Kim SH, Choi D, Kim SH, et al. Ferucarbotran-enhanced MRI versus triple- phase MDCT for the preoperative detection of hepatocellular carcinoma. Am J Roentgenol 2005; 184: 1069-76. Kim SH, Choi D, Kim SH, et al. Ferucarbotran-enhanced MRI versus triple- phase MDCT for the preoperative detection of hepatocellular carcinoma. Am J Roentgenol 2005; 184: 1069-76.
30.
go back to reference Numminen K, Isoniemi H, Halavaara J, et al. Preoperative assessment of focal liver lesions: multidetector computed tomography challenges magnetic resonance imaging. Acta Radiol 2005; 46: 9-15.CrossRefPubMed Numminen K, Isoniemi H, Halavaara J, et al. Preoperative assessment of focal liver lesions: multidetector computed tomography challenges magnetic resonance imaging. Acta Radiol 2005; 46: 9-15.CrossRefPubMed
31.
go back to reference Ward J, Robinson PJ, Ashley Guthrie J, et al. Liver metastases in candidates for hepatic resection: comparison of helical CT and gadolinium- and SPIO-enhanced MR imaging. Radiology 2005; 237: 170-180.CrossRefPubMed Ward J, Robinson PJ, Ashley Guthrie J, et al. Liver metastases in candidates for hepatic resection: comparison of helical CT and gadolinium- and SPIO-enhanced MR imaging. Radiology 2005; 237: 170-180.CrossRefPubMed
32.
go back to reference Krakora GA, Coakley FV, Williams G, Yeh BM, Breiman RS, Qayyum A. Small hypoattenuating hepatic lesions at contrast-enhanced CT: prognostic importance in patients with breast cancer. Radiology 2004; 233: 667-673.CrossRefPubMed Krakora GA, Coakley FV, Williams G, Yeh BM, Breiman RS, Qayyum A. Small hypoattenuating hepatic lesions at contrast-enhanced CT: prognostic importance in patients with breast cancer. Radiology 2004; 233: 667-673.CrossRefPubMed
33.
go back to reference Kim YK, Ko SW, Hwang SB, Kim CS, Yu HC. Detection and characterization of liver metastases: 16–slice multidetector computed tomography versus superparamagnetic iron oxide–enhanced magnetic resonance imaging. Eur Radiol 2006; 16: 1337-1345.CrossRefPubMed Kim YK, Ko SW, Hwang SB, Kim CS, Yu HC. Detection and characterization of liver metastases: 16–slice multidetector computed tomography versus superparamagnetic iron oxide–enhanced magnetic resonance imaging. Eur Radiol 2006; 16: 1337-1345.CrossRefPubMed
34.
go back to reference Ruers TJ, Langenhoff BS, Neeleman N, et al. Value of Positron Emission Tomography with F18-Fluorodeoxyglucose in patients with colorectal liver metastases: a prospective study. Journal of Clinical Oncology, 2002; 15: 388-395.CrossRef Ruers TJ, Langenhoff BS, Neeleman N, et al. Value of Positron Emission Tomography with F18-Fluorodeoxyglucose in patients with colorectal liver metastases: a prospective study. Journal of Clinical Oncology, 2002; 15: 388-395.CrossRef
35.
go back to reference Rappeport ED, Loft A, Berthelsen AK, et al. Contrast-Enhanced 18FDG-PET/CT vs. SPIO-Enhanced MRI vs. 18FDG-PET vs. CT in Patients with Liver Metastases from Colorectal Cancer: A Prospective Study with Intraoperative Confirmation Acta Radiol 2007; 4: 369-78.CrossRef Rappeport ED, Loft A, Berthelsen AK, et al. Contrast-Enhanced 18FDG-PET/CT vs. SPIO-Enhanced MRI vs. 18FDG-PET vs. CT in Patients with Liver Metastases from Colorectal Cancer: A Prospective Study with Intraoperative Confirmation Acta Radiol 2007; 4: 369-78.CrossRef
36.
go back to reference Fong Y, Saldinger PF, Akhurst T, et al. Utility of 18F-FDG positron emission tomography scanning on selection of patients for resection of hepatic colorectal metastases. Am J Surg 1999; 178: 282-287.CrossRefPubMed Fong Y, Saldinger PF, Akhurst T, et al. Utility of 18F-FDG positron emission tomography scanning on selection of patients for resection of hepatic colorectal metastases. Am J Surg 1999; 178: 282-287.CrossRefPubMed
37.
go back to reference Sahani DV, Kalva SP, Fischman AJ, Kadavigere R, Blake M, Hahn PF. Detection of liver metastases from adenocarcinoma of the colon and pancreas: comparison of mangafodipir trisodium-enhanced liver MRI and whole-body FDG PET. Am J Roentgenol 2005; 185: 239-246. Sahani DV, Kalva SP, Fischman AJ, Kadavigere R, Blake M, Hahn PF. Detection of liver metastases from adenocarcinoma of the colon and pancreas: comparison of mangafodipir trisodium-enhanced liver MRI and whole-body FDG PET. Am J Roentgenol 2005; 185: 239-246.
38.
go back to reference Selzner M, Hany TF, Wildbrett P, et al. Does the novel PET/CT imaging modality impact on the treatment of patients with metastatic colorectal cancer of the liver? Ann Surg 2004; 240: 1027-1035.CrossRefPubMed Selzner M, Hany TF, Wildbrett P, et al. Does the novel PET/CT imaging modality impact on the treatment of patients with metastatic colorectal cancer of the liver? Ann Surg 2004; 240: 1027-1035.CrossRefPubMed
39.
go back to reference Chua SC, Groves AM, Kayani I, et al. The impact of 18F-FDG PET/CT in patients with liver metastases. Eur J Nucl Med Mol Imaging 2007; 34: 1906-1914.CrossRefPubMed Chua SC, Groves AM, Kayani I, et al. The impact of 18F-FDG PET/CT in patients with liver metastases. Eur J Nucl Med Mol Imaging 2007; 34: 1906-1914.CrossRefPubMed
40.
go back to reference Ward J, Chen F, Guthrie JA, et al. Hepatic lesion detection after superparamagnetic iron oxide enhancement: comparison of five T2-weighted sequences at 1.0 T by using alternative-free response receiver operating characteristic analysis. Radiology 2000; 214: 159-166.PubMed Ward J, Chen F, Guthrie JA, et al. Hepatic lesion detection after superparamagnetic iron oxide enhancement: comparison of five T2-weighted sequences at 1.0 T by using alternative-free response receiver operating characteristic analysis. Radiology 2000; 214: 159-166.PubMed
41.
go back to reference Ba-Ssalamah A, Heinz-Peer G, Schima W, et al. Detection of focal hepatic lesions: comparison of unenhanced and SHU 555 A-enhanced MR imaging versus biphasic helical CTAP. J Magn Reson Imaging 2000; 11: 665-672.CrossRefPubMed Ba-Ssalamah A, Heinz-Peer G, Schima W, et al. Detection of focal hepatic lesions: comparison of unenhanced and SHU 555 A-enhanced MR imaging versus biphasic helical CTAP. J Magn Reson Imaging 2000; 11: 665-672.CrossRefPubMed
42.
go back to reference Blakeborough A, Ward J, Wilson D, et al. Hepatic lesion detection at MR imaging: a comparative study with four sequences. Radiology 1997; 203: 759-765.PubMed Blakeborough A, Ward J, Wilson D, et al. Hepatic lesion detection at MR imaging: a comparative study with four sequences. Radiology 1997; 203: 759-765.PubMed
43.
go back to reference del Frate C, Bazzocchi M, Mortele KJ, et al. Detection of liver metastases: comparison of gadobenate dimeglumine-enhanced MR imaging examinations. Radiology 2002; 225: 766-772.CrossRefPubMed del Frate C, Bazzocchi M, Mortele KJ, et al. Detection of liver metastases: comparison of gadobenate dimeglumine-enhanced MR imaging examinations. Radiology 2002; 225: 766-772.CrossRefPubMed
44.
go back to reference Furuhata T, Okita K, Tsuruma T, et al. Efficacy of SPIOMR imaging in the diagnosis of liver metastases from colorectal carcinomas. Dig Surg 2003; 20: 321-325.CrossRefPubMed Furuhata T, Okita K, Tsuruma T, et al. Efficacy of SPIOMR imaging in the diagnosis of liver metastases from colorectal carcinomas. Dig Surg 2003; 20: 321-325.CrossRefPubMed
45.
go back to reference Hagspiel KD, Neidl KF, Eichenberger AC, et al. Detection of liver metastases: comparison of superparamagnetic iron oxide enhanced and unenhanced MR imaging at 1.5 T with dynamic CT, intraoperative US, and percutaneous US. Radiology 1995; 196: 471-478.PubMed Hagspiel KD, Neidl KF, Eichenberger AC, et al. Detection of liver metastases: comparison of superparamagnetic iron oxide enhanced and unenhanced MR imaging at 1.5 T with dynamic CT, intraoperative US, and percutaneous US. Radiology 1995; 196: 471-478.PubMed
46.
go back to reference Kim HJ, Kim KW, Byun JH, et al. Comparison of mangafodipir trisodium- and ferucarbotran-enhanced MRI for detection and characterization of hepatic metastases in colorectal cancer patients. Am J Roentgenol 2006; 186: 1059-1066.CrossRef Kim HJ, Kim KW, Byun JH, et al. Comparison of mangafodipir trisodium- and ferucarbotran-enhanced MRI for detection and characterization of hepatic metastases in colorectal cancer patients. Am J Roentgenol 2006; 186: 1059-1066.CrossRef
47.
go back to reference Kim YK, Lee JM, Kim CS, et al. Detection of liver metastases: gadobenate dimeglumine-enhanced three dimensional dynamic phases and one-hour delayed phase MR imaging versus superparamagnetic iron oxide-enhanced-MR imaging. Eur Radiol 2005; 15: 220-228.CrossRefPubMed Kim YK, Lee JM, Kim CS, et al. Detection of liver metastases: gadobenate dimeglumine-enhanced three dimensional dynamic phases and one-hour delayed phase MR imaging versus superparamagnetic iron oxide-enhanced-MR imaging. Eur Radiol 2005; 15: 220-228.CrossRefPubMed
48.
go back to reference Lencioni R, Donati F, Cioni D, et al. Detection of colorectal liver metastases: prospective comparison of unenhanced and ferumoxides-enhanced magnetic resonance imaging at 1.5 T, dual phase spiral CT, and spiral CT during arterial portography. MAGMA 1998; 7: 76-83.CrossRefPubMed Lencioni R, Donati F, Cioni D, et al. Detection of colorectal liver metastases: prospective comparison of unenhanced and ferumoxides-enhanced magnetic resonance imaging at 1.5 T, dual phase spiral CT, and spiral CT during arterial portography. MAGMA 1998; 7: 76-83.CrossRefPubMed
49.
go back to reference Van Beers BE, Lacrosse M, Jamart J, et al. Detection and segmental location of malignant hepatic tumors: comparison of ferumoxides-enhanced gradient-echo and T2-weighted spin-echo MR imaging. Am J Roentgenol 1997; 168: 713-717. Van Beers BE, Lacrosse M, Jamart J, et al. Detection and segmental location of malignant hepatic tumors: comparison of ferumoxides-enhanced gradient-echo and T2-weighted spin-echo MR imaging. Am J Roentgenol 1997; 168: 713-717.
50.
go back to reference Ward J, Naik KS, Guthrie JA, et al. Hepatic lesion detection: comparison of superparamagnetic iron oxide with dual-phase CT by using alternative-free response receiver operating characteristic analyses. Radiology 1999; 210: 459-466.PubMed Ward J, Naik KS, Guthrie JA, et al. Hepatic lesion detection: comparison of superparamagnetic iron oxide with dual-phase CT by using alternative-free response receiver operating characteristic analyses. Radiology 1999; 210: 459-466.PubMed
51.
go back to reference Ward J, Guthrie JA, Wilson D, et al. Colorectal hepatic metastases: detection with SPIO-enhanced breath-hold MR imaging-comparison of optimized sequences. Radiology 2003; 228: 709-718.CrossRefPubMed Ward J, Guthrie JA, Wilson D, et al. Colorectal hepatic metastases: detection with SPIO-enhanced breath-hold MR imaging-comparison of optimized sequences. Radiology 2003; 228: 709-718.CrossRefPubMed
52.
go back to reference Ch’en IY, Katz DS, Jeffrey RB Jr, et al. Do arterial phase helical CT images improve detection or characterization of colorectal liver metastases? J Comput Assist Tomogr 1997; 21: 391-397.CrossRefPubMed Ch’en IY, Katz DS, Jeffrey RB Jr, et al. Do arterial phase helical CT images improve detection or characterization of colorectal liver metastases? J Comput Assist Tomogr 1997; 21: 391-397.CrossRefPubMed
Metadata
Title
Detection of colo-rectal liver metastases: prospective comparison of contrast enhanced US, multidetector CT, PET/CT, and 1.5 Tesla MR with extracellular and reticulo-endothelial cell specific contrast agents
Authors
Pier Paolo Mainenti
Marcello Mancini
Ciro Mainolfi
Luigi Camera
Simone Maurea
Antonietta Manchia
Michela Tanga
Francesco Persico
Pietro Addeo
Dario D’Antonio
Antonio Speranza
Luigi Bucci
Giovanni Persico
Leonardo Pace
Marco Salvatore
Publication date
01-10-2010
Publisher
Springer-Verlag
Published in
Abdominal Radiology / Issue 5/2010
Print ISSN: 2366-004X
Electronic ISSN: 2366-0058
DOI
https://doi.org/10.1007/s00261-009-9555-2

Other articles of this Issue 5/2010

Abdominal Radiology 5/2010 Go to the issue
Obesity Clinical Trial Summary

At a glance: The STEP trials

A round-up of the STEP phase 3 clinical trials evaluating semaglutide for weight loss in people with overweight or obesity.

Developed by: Springer Medicine

Highlights from the ACC 2024 Congress

Year in Review: Pediatric cardiology

Watch Dr. Anne Marie Valente present the last year's highlights in pediatric and congenital heart disease in the official ACC.24 Year in Review session.

Year in Review: Pulmonary vascular disease

The last year's highlights in pulmonary vascular disease are presented by Dr. Jane Leopold in this official video from ACC.24.

Year in Review: Valvular heart disease

Watch Prof. William Zoghbi present the last year's highlights in valvular heart disease from the official ACC.24 Year in Review session.

Year in Review: Heart failure and cardiomyopathies

Watch this official video from ACC.24. Dr. Biykem Bozkurt discuss last year's major advances in heart failure and cardiomyopathies.