Skip to main content
Top
Published in: Abdominal Radiology 6/2008

01-11-2008

Staging of colon cancer: whole-body MRI vs. whole-body PET-CT—initial clinical experience

Authors: Ettore Squillaci, Guglielmo Manenti, Stefano Mancino, Carmelo Cicciò, Ferdinando Calabria, Roberta Danieli, Orazio Schillaci, Giovanni Simonetti

Published in: Abdominal Radiology | Issue 6/2008

Login to get access

Abstract

Background

To assess the accuracy of whole-body MR imaging (WB-MRI) in comparison with whole-body [18F]-2-fluoro-2-deoxy-d-glucose (FDG) PET-CT in staging patients with diagnosed colorectal carcinoma (CRC).

Methods

Twenty consecutive patients with previously diagnosed CRC underwent WB-MRI (3T) and PET-CT for staging of lymph node (N) and distant metastases (M). Evaluation was done according to the American Joint Committee on Cancer Staging Criteria. MR images were evaluated by two radiologists while PET-CT images by one radiologist and one nuclear medicine physician. Histology and/or a clinical follow-up of 3–6 months served as standard of reference.

Results

Lymph node involvement was determined in 10/20 cases as N-positive in WB-MRI and in 15/20 in PET-CT. M-stage was evaluated for liver metastases (27 lesions in 15 patients with WB-MRI, 23/15 patients with PET-CT), lung (19/5 patients with WB-MRI, 25/7 patients with PET-CT), and bone (9/3 patients with WB-MRI, 9/3 patients with PET-CT). Two patients showed peritoneal implants and three patients demonstrated local recurrence at the surgery site on both modalities. No brain metastases were found.

Conclusions

WB-MRI is a feasible method for examining colon cancer patients but cannot displace the present role of PET-CT.
Literature
1.
go back to reference Ahmedin J, Rebecca S, Elizabeth W, et al. (2007) Cancer statistics, 2007. CA Cancer J Clin 57:43–66CrossRef Ahmedin J, Rebecca S, Elizabeth W, et al. (2007) Cancer statistics, 2007. CA Cancer J Clin 57:43–66CrossRef
2.
go back to reference Saunders TH, Mendes Ribeiro HK, Gleeson FV (2002) New techniques for imaging colorectal cancer: the use of MRI, PET and radioimmunoscintigraphy for primary staging and follow-up Br Med Bull 64:81–99PubMedCrossRef Saunders TH, Mendes Ribeiro HK, Gleeson FV (2002) New techniques for imaging colorectal cancer: the use of MRI, PET and radioimmunoscintigraphy for primary staging and follow-up Br Med Bull 64:81–99PubMedCrossRef
3.
go back to reference Pickhardt P, Choi J, Hwang I, et al. (2003) Computed tomographic virtual colonoscopy to screen for colorectal neoplasia in asymptomatic adults N Eng J Med 349:2191–2200CrossRef Pickhardt P, Choi J, Hwang I, et al. (2003) Computed tomographic virtual colonoscopy to screen for colorectal neoplasia in asymptomatic adults N Eng J Med 349:2191–2200CrossRef
4.
go back to reference Lauenstein TC, Goehde SC, Herborn CU, et al. (2004) Whole-body MR imaging: evaluation of patients for metastases Radiology 233:139–148PubMedCrossRef Lauenstein TC, Goehde SC, Herborn CU, et al. (2004) Whole-body MR imaging: evaluation of patients for metastases Radiology 233:139–148PubMedCrossRef
5.
go back to reference Schmidt GP, Baur-Melnyk A, Herzog P, et al. (2005) High-resolution whole-body magnetic resonance image tumor staging with the use of parallel imaging versus dual-modality positron emission tomography computed tomography: experience on a 32-channel system Invest Radiol 40:743–753PubMedCrossRef Schmidt GP, Baur-Melnyk A, Herzog P, et al. (2005) High-resolution whole-body magnetic resonance image tumor staging with the use of parallel imaging versus dual-modality positron emission tomography computed tomography: experience on a 32-channel system Invest Radiol 40:743–753PubMedCrossRef
6.
go back to reference Tausig A, Manthey N, Berger F, et al. (2000) Advantages and limitations of wholebody bone marrow MRI using Turbo-STIR sequences in comparison to planar bone scans Nuklearmedizin 39:174–179PubMed Tausig A, Manthey N, Berger F, et al. (2000) Advantages and limitations of wholebody bone marrow MRI using Turbo-STIR sequences in comparison to planar bone scans Nuklearmedizin 39:174–179PubMed
7.
go back to reference Eustace S, Tello R, DeCarvalho V, et al. (1997) A comparison of whole-body turboSTIR MR imaging and planar 99 mTc-methylene diphosphonate scintigraphy in the examination of patients with suspected skeletal metastases AJR Am J Roentgenol 169:1655–1661PubMed Eustace S, Tello R, DeCarvalho V, et al. (1997) A comparison of whole-body turboSTIR MR imaging and planar 99 mTc-methylene diphosphonate scintigraphy in the examination of patients with suspected skeletal metastases AJR Am J Roentgenol 169:1655–1661PubMed
8.
go back to reference Iva K, Ludmila L, Otavar B, et al. (2003) Routine 18F-FDG PET preoperative staging of colorectal cancer: comparison with conventional staging and its impact on treatment decision making J Nucl Med 44(11):1784–1788 Iva K, Ludmila L, Otavar B, et al. (2003) Routine 18F-FDG PET preoperative staging of colorectal cancer: comparison with conventional staging and its impact on treatment decision making J Nucl Med 44(11):1784–1788
9.
go back to reference Dominique D, William HM (2004) PET and PET-CT evaluation of colorectal carcinoma Semin Nucl Med 34(3):209–223CrossRef Dominique D, William HM (2004) PET and PET-CT evaluation of colorectal carcinoma Semin Nucl Med 34(3):209–223CrossRef
10.
go back to reference Abdel-Nabi H, Doerr RJ, Lamonica DM, et al. (1998) Staging of primary colorectal carcinomas with fluorine-18 fluorodeoxyglucose whole-body PET: correlation with histopathologic and CT findings Radiology 206:755–760PubMed Abdel-Nabi H, Doerr RJ, Lamonica DM, et al. (1998) Staging of primary colorectal carcinomas with fluorine-18 fluorodeoxyglucose whole-body PET: correlation with histopathologic and CT findings Radiology 206:755–760PubMed
11.
go back to reference Cohade C, Osman M, Leal J, et al. (2003) Direct comparison of (18)F-FDG PET and PET/CT in patients with colorectal carcinoma J Nucl Med 44:1797–1803PubMed Cohade C, Osman M, Leal J, et al. (2003) Direct comparison of (18)F-FDG PET and PET/CT in patients with colorectal carcinoma J Nucl Med 44:1797–1803PubMed
12.
go back to reference Beyer T, Townsend DW, Brun T, et al. (2000) A combined PET/CT scanner for clinical oncology J Nucl Med 4:1369–1379 Beyer T, Townsend DW, Brun T, et al. (2000) A combined PET/CT scanner for clinical oncology J Nucl Med 4:1369–1379
13.
go back to reference Bar-Shalom R, Yefremov N, Guralnik L, et al. (2000) Clinical performance of PET/CT in evaluation of cancer: additional value for diagnostic imaging and patient management J Nucl Med 44:1200–1209 Bar-Shalom R, Yefremov N, Guralnik L, et al. (2000) Clinical performance of PET/CT in evaluation of cancer: additional value for diagnostic imaging and patient management J Nucl Med 44:1200–1209
14.
go back to reference Greene FL, Page DL, Fleming ID, et al. (eds). (2002) AJCC cancer staging manual, 6th edn. Springer, New York, NY Greene FL, Page DL, Fleming ID, et al. (eds). (2002) AJCC cancer staging manual, 6th edn. Springer, New York, NY
15.
go back to reference Flamen P, Stroobants S, Van Cutsem E (1999) Additional value of whole-body positron emission tomography with fluorine-18-2-fluoro-2- deoxy-d-glucose in recurrent colorectal cancer J Clin Oncol 17:894–901PubMed Flamen P, Stroobants S, Van Cutsem E (1999) Additional value of whole-body positron emission tomography with fluorine-18-2-fluoro-2- deoxy-d-glucose in recurrent colorectal cancer J Clin Oncol 17:894–901PubMed
16.
go back to reference Lauenstein T, Freudenberg L, Goehde S, et al. (2002) Wholebody MRI using a rolling table platform for the detection of bone metastases Eur Radiol 12:2091–2099PubMed Lauenstein T, Freudenberg L, Goehde S, et al. (2002) Wholebody MRI using a rolling table platform for the detection of bone metastases Eur Radiol 12:2091–2099PubMed
17.
go back to reference Horvath LJ, Burtness BA, McCarthy S, et al. (1999) Total-body echo-planar MR imaging in the staging of breast cancer: comparison with conventional methods-early experience Radiology 211:119–128PubMed Horvath LJ, Burtness BA, McCarthy S, et al. (1999) Total-body echo-planar MR imaging in the staging of breast cancer: comparison with conventional methods-early experience Radiology 211:119–128PubMed
18.
go back to reference Barkhausen J, Quick HH, Lauenstein T, et al. (2001) Whole body MR imaging in 30 seconds with real-time true FISP and a continuously rolling table platform: feasibility study Radiology 220:252–256PubMed Barkhausen J, Quick HH, Lauenstein T, et al. (2001) Whole body MR imaging in 30 seconds with real-time true FISP and a continuously rolling table platform: feasibility study Radiology 220:252–256PubMed
19.
go back to reference Lauenstein TC, Goehde SC, Herborn CU, et al. (2002) Three-dimensional volumetric interpolated breath-hold MR imaging for whole-body tumor staging in less than 15 minutes: a feasibility study AJR Am J Roentgenol 179:445–449PubMed Lauenstein TC, Goehde SC, Herborn CU, et al. (2002) Three-dimensional volumetric interpolated breath-hold MR imaging for whole-body tumor staging in less than 15 minutes: a feasibility study AJR Am J Roentgenol 179:445–449PubMed
20.
go back to reference Pruessmann KP,Weiger M, Scheidegger MB, et al. (1999) SENSE: sensitivityencoding for fast MRI Magn Reson Med 42:952–962PubMedCrossRef Pruessmann KP,Weiger M, Scheidegger MB, et al. (1999) SENSE: sensitivityencoding for fast MRI Magn Reson Med 42:952–962PubMedCrossRef
21.
go back to reference Eustace S, Walker R, Blake M, et al. (1999) Whole-body MR imaging. Practical issues, clinical applications, and future directions Magn Reson Imaging Clin N Am 7:209–236PubMed Eustace S, Walker R, Blake M, et al. (1999) Whole-body MR imaging. Practical issues, clinical applications, and future directions Magn Reson Imaging Clin N Am 7:209–236PubMed
22.
go back to reference Antoch G, Vogt F, Freudenberg L, et al. (2003) Whole-body dualmodality PET/CT and whole-body MRI for tumor staging in oncology JAMA 290:3199–3206PubMedCrossRef Antoch G, Vogt F, Freudenberg L, et al. (2003) Whole-body dualmodality PET/CT and whole-body MRI for tumor staging in oncology JAMA 290:3199–3206PubMedCrossRef
23.
go back to reference Muller-Horvat C, Radny P, Eigentler TK, et al. (2006) Prospective comparison of the impact on treatment decisions of whole-body magnetic resonance imaging and computed tomography in patients with metastatic malignant melanoma Eur J Cancer 42(3):342–350PubMedCrossRef Muller-Horvat C, Radny P, Eigentler TK, et al. (2006) Prospective comparison of the impact on treatment decisions of whole-body magnetic resonance imaging and computed tomography in patients with metastatic malignant melanoma Eur J Cancer 42(3):342–350PubMedCrossRef
24.
go back to reference Schlemmer HP, Schafer J, Pfannenberg C, et al. (2005) Fast whole-body assessment of metastatic disease using a novel magnetic resonance imaging system: initial experiences Invest Radiol l40:64–71CrossRef Schlemmer HP, Schafer J, Pfannenberg C, et al. (2005) Fast whole-body assessment of metastatic disease using a novel magnetic resonance imaging system: initial experiences Invest Radiol l40:64–71CrossRef
25.
go back to reference Juergen FS, Heinz-Peter WS (2006) Total-body MR-imaging in oncology Eur Radiol 16:2000–2015CrossRef Juergen FS, Heinz-Peter WS (2006) Total-body MR-imaging in oncology Eur Radiol 16:2000–2015CrossRef
26.
go back to reference Takahara T, Imay Y, Yamashita T, et al. (2004) Diffusion weighted whole body imaging with background body signal suppression (DWIBS): technical improvement using free breathing, STIR and high resolution 3D display Radiat Med 22:275–282PubMed Takahara T, Imay Y, Yamashita T, et al. (2004) Diffusion weighted whole body imaging with background body signal suppression (DWIBS): technical improvement using free breathing, STIR and high resolution 3D display Radiat Med 22:275–282PubMed
27.
go back to reference Petra M, Carsten K, Frank T, et al. (2007) Diffusion-weighted whole-body MR imaging with background body signal suppression: a feasibility study at 3.0 Tesla. Eur Radiol 17(12):3031–3037CrossRef Petra M, Carsten K, Frank T, et al. (2007) Diffusion-weighted whole-body MR imaging with background body signal suppression: a feasibility study at 3.0 Tesla. Eur Radiol 17(12):3031–3037CrossRef
28.
go back to reference Semelka RC, Worawattanakul S, Kelekis NL, et al. (1997) Liver lesion detection, characterization, and effect on patient management: comparison of single-phase spiral CT and current MR techniques J Magn Reson Imaging 7(6):1040–1047PubMedCrossRef Semelka RC, Worawattanakul S, Kelekis NL, et al. (1997) Liver lesion detection, characterization, and effect on patient management: comparison of single-phase spiral CT and current MR techniques J Magn Reson Imaging 7(6):1040–1047PubMedCrossRef
29.
go back to reference Yang M, Martin DR, Karabulut N, et al. (2003) Comparison of MR and PET imaging for the evaluation of liver metastases J Magn Reson Imaging 17(3):343–349PubMedCrossRef Yang M, Martin DR, Karabulut N, et al. (2003) Comparison of MR and PET imaging for the evaluation of liver metastases J Magn Reson Imaging 17(3):343–349PubMedCrossRef
30.
go back to reference Richard CS, Diego RM, Cem B, et al. (2001) Focal liver lesions: comparison of dual-phase CT and multisequence multiplanar MR imaging including dynamic gadolinium enhancement J Magn Reson Imaging 13(3):397–401CrossRef Richard CS, Diego RM, Cem B, et al. (2001) Focal liver lesions: comparison of dual-phase CT and multisequence multiplanar MR imaging including dynamic gadolinium enhancement J Magn Reson Imaging 13(3):397–401CrossRef
31.
go back to reference Rappeport ED, Loft A, Berthelsen AK, et al. (2007) Contrast-enhanced FDG-PET/CT vs. SPIO-enhanced MRI vs. FDG-PET vs. CT in patients with liver metastases from colorectal cancer: a prospective study with intraoperative confirmation Acta Radiol 48(4):369–378PubMedCrossRef Rappeport ED, Loft A, Berthelsen AK, et al. (2007) Contrast-enhanced FDG-PET/CT vs. SPIO-enhanced MRI vs. FDG-PET vs. CT in patients with liver metastases from colorectal cancer: a prospective study with intraoperative confirmation Acta Radiol 48(4):369–378PubMedCrossRef
32.
go back to reference Rappeport ED, Loft A (2007) Liver metastases from colorectal cancer: imaging with superparamagnetic iron oxide (SPIO)-enhanced MR imaging, computed tomography and positron emission tomography. Abdom Imaging 32(5):624–634PubMedCrossRef Rappeport ED, Loft A (2007) Liver metastases from colorectal cancer: imaging with superparamagnetic iron oxide (SPIO)-enhanced MR imaging, computed tomography and positron emission tomography. Abdom Imaging 32(5):624–634PubMedCrossRef
33.
go back to reference Steinborn MM, Heuck AF, Tiling R, et al. (1999) Whole-body bone marrow MRI in patients with metastatic disease to the skeletal system J Comput Assist Tomogr 23:123–129PubMedCrossRef Steinborn MM, Heuck AF, Tiling R, et al. (1999) Whole-body bone marrow MRI in patients with metastatic disease to the skeletal system J Comput Assist Tomogr 23:123–129PubMedCrossRef
Metadata
Title
Staging of colon cancer: whole-body MRI vs. whole-body PET-CT—initial clinical experience
Authors
Ettore Squillaci
Guglielmo Manenti
Stefano Mancino
Carmelo Cicciò
Ferdinando Calabria
Roberta Danieli
Orazio Schillaci
Giovanni Simonetti
Publication date
01-11-2008
Publisher
Springer-Verlag
Published in
Abdominal Radiology / Issue 6/2008
Print ISSN: 2366-004X
Electronic ISSN: 2366-0058
DOI
https://doi.org/10.1007/s00261-007-9347-5

Other articles of this Issue 6/2008

Abdominal Radiology 6/2008 Go to the issue