Skip to main content
Top
Published in: European Journal of Nuclear Medicine and Molecular Imaging 1/2019

01-01-2019 | Original Article

Contribution of PET imaging to mortality risk stratification in candidates to lead extraction for pacemaker or defibrillator infection: a prospective single center study

Authors: Igor Diemberger, Rachele Bonfiglioli, Cristian Martignani, Maddalena Graziosi, Mauro Biffi, Stefano Lorenzetti, Matteo Ziacchi, Cristina Nanni, Stefano Fanti, Giuseppe Boriani

Published in: European Journal of Nuclear Medicine and Molecular Imaging | Issue 1/2019

Login to get access

Abstract

Purpose

18F-FDG PET/CT is an emerging technique for diagnosis of cardiac implantable electronic devices infection (CIEDI). Despite the improvements in transvenous lead extraction (TLE), long-term survival in patients with CIEDI is poor. The aim of the present study was to evaluate whether the extension of CIEDI at 18F-FDG PET/CT can improve prediction of survival after TLE.

Methods

Prospective, monocentric observational study enrolling consecutive candidates to TLE for a diagnosis of CIEDI. 18F-FDG PET/CT was performed in all patients prior TLE.

Results

There were 105 consecutive patients with confirmed CIEDI enrolled. An increased 18F-FDG uptake was limited to cardiac implantable electrical device (CIED) pocket in 56 patients, 40 patients had a systemic involvement. We had nine negative PET in patients undergoing prolonged antimicrobial therapy (22.5 ± 14.0 days vs. 8.6 ± 13.0 days; p = 0.005). Implementation of 18F-FDG PET/CT in modified Duke Criteria lead to reclassification of 23.8% of the patients. After a mean follow-up of 25.0 ± 9.0 months, 31 patients died (29.5%). Patients with CIED pocket involvement at 18F-FDG PET/CT presented a better survival independently of presence/absence of systemic involvement (HR 0.493, 95%CI 0.240–0.984; p = 0.048). After integration of 18F-FDG PET/CT data, absence of overt/hidden pocket involvement in CIEDI and a (glomerular filtration rate) GFR < 60 ml/min were the only independent predictors of mortality at long term.

Conclusions

Patient with CIEDI and a Cold Closed Pocket (i.e., a CIED pocket without skin erosion/perforation nor increased capitation at 18F-FDG PET/CT) present worse long-term survival. Patient management can benefit by systematic adoption of pre-TLE 18F-FDG PET/CT through improved identification of CIED related endocarditis (CIEDIE) and hidden involvement of CIED pocket.
Literature
2.
go back to reference Tarakji KG, Wazni OM, Harb S, Hsu A, Saliba W, Wilkoff BL. Risk factors for 1-year mortality among patients with cardiac implantable electronic device infection undergoing transvenous lead extraction: the impact of the infection type and the presence of vegetation on survival. Europace. 2014;16(10):1490–5. https://doi.org/10.1093/europace/euu147.CrossRefPubMed Tarakji KG, Wazni OM, Harb S, Hsu A, Saliba W, Wilkoff BL. Risk factors for 1-year mortality among patients with cardiac implantable electronic device infection undergoing transvenous lead extraction: the impact of the infection type and the presence of vegetation on survival. Europace. 2014;16(10):1490–5. https://​doi.​org/​10.​1093/​europace/​euu147.CrossRefPubMed
3.
go back to reference Habib G, Lancellotti P, Antunes MJ, Bongiorni MG, Casalta JP, Del Zotti F, et al. 2015 ESC guidelines for the management of infective endocarditis: the task force for the management of infective endocarditis of the European Society of Cardiology (ESC). Endorsed by: European Association for Cardio-Thoracic Surgery (EACTS), the European Association of Nuclear Medicine (EANM). Eur Heart J. 2015;36(44):3075–128. https://doi.org/10.1093/eurheartj/ehv319.CrossRefPubMed Habib G, Lancellotti P, Antunes MJ, Bongiorni MG, Casalta JP, Del Zotti F, et al. 2015 ESC guidelines for the management of infective endocarditis: the task force for the management of infective endocarditis of the European Society of Cardiology (ESC). Endorsed by: European Association for Cardio-Thoracic Surgery (EACTS), the European Association of Nuclear Medicine (EANM). Eur Heart J. 2015;36(44):3075–128. https://​doi.​org/​10.​1093/​eurheartj/​ehv319.CrossRefPubMed
8.
go back to reference Bongiorni MG, Burri H, Deharo JC, Stark C, Kennergren C, Saghy L, et al. 2018 EHRA expert consensus statement on lead extraction: recommendations on definitions, endpoints, research trial design, and data collection requirements for clinical scientific studies and registries: endorsed by APHRS/HRS/LAHRS. Europace. 2018. https://doi.org/10.1093/europace/euy050.CrossRef Bongiorni MG, Burri H, Deharo JC, Stark C, Kennergren C, Saghy L, et al. 2018 EHRA expert consensus statement on lead extraction: recommendations on definitions, endpoints, research trial design, and data collection requirements for clinical scientific studies and registries: endorsed by APHRS/HRS/LAHRS. Europace. 2018. https://​doi.​org/​10.​1093/​europace/​euy050.CrossRef
16.
go back to reference Shariff N, Eby E, Adelstein E, Jain S, Shalaby A, Saba S, et al. Health and economic outcomes associated with use of an antimicrobial envelope as a standard of care for cardiac implantable electronic device implantation. J Cardiovasc Electrophysiol. 2015;26(7):783–9. https://doi.org/10.1111/jce.12684.CrossRefPubMed Shariff N, Eby E, Adelstein E, Jain S, Shalaby A, Saba S, et al. Health and economic outcomes associated with use of an antimicrobial envelope as a standard of care for cardiac implantable electronic device implantation. J Cardiovasc Electrophysiol. 2015;26(7):783–9. https://​doi.​org/​10.​1111/​jce.​12684.CrossRefPubMed
22.
24.
go back to reference Juneau D, Golfam M, Hazra S, Zuckier LS, Garas S, Redpath C, et al. Positron emission tomography and single-photon emission computed tomography imaging in the diagnosis of cardiac implantable electronic device infection: a systematic review and meta-analysis. Circ Cardiovasc Imaging. 2017;10(4). https://doi.org/10.1161/CIRCIMAGING.116.005772. Juneau D, Golfam M, Hazra S, Zuckier LS, Garas S, Redpath C, et al. Positron emission tomography and single-photon emission computed tomography imaging in the diagnosis of cardiac implantable electronic device infection: a systematic review and meta-analysis. Circ Cardiovasc Imaging. 2017;10(4). https://​doi.​org/​10.​1161/​CIRCIMAGING.​116.​005772.
Metadata
Title
Contribution of PET imaging to mortality risk stratification in candidates to lead extraction for pacemaker or defibrillator infection: a prospective single center study
Authors
Igor Diemberger
Rachele Bonfiglioli
Cristian Martignani
Maddalena Graziosi
Mauro Biffi
Stefano Lorenzetti
Matteo Ziacchi
Cristina Nanni
Stefano Fanti
Giuseppe Boriani
Publication date
01-01-2019
Publisher
Springer Berlin Heidelberg
Published in
European Journal of Nuclear Medicine and Molecular Imaging / Issue 1/2019
Print ISSN: 1619-7070
Electronic ISSN: 1619-7089
DOI
https://doi.org/10.1007/s00259-018-4142-9

Other articles of this Issue 1/2019

European Journal of Nuclear Medicine and Molecular Imaging 1/2019 Go to the issue