Skip to main content
Top
Published in: European Journal of Nuclear Medicine and Molecular Imaging 7/2015

01-06-2015 | Original Article

Biodistribution and radiation dosimetry of 82Rb at rest and during peak pharmacological stress in patients referred for myocardial perfusion imaging

Authors: Chad R. R. N. Hunter, Jeremy Hill, M. Cecilia Ziadi, Rob S. B. Beanlands, Robert A. deKemp

Published in: European Journal of Nuclear Medicine and Molecular Imaging | Issue 7/2015

Login to get access

Abstract

Purpose

82Rb is an ultra-short-lived positron emitter used for myocardial blood flow quantification with PET imaging. The aim of this study was to quantify the biodistribution and radiation dosimetry in patients with coronary disease and in healthy normal volunteers.

Methods

A total of 30 subjects, 26 patients with known or suspected coronary artery disease (CAD) and four healthy volunteers were injected with 82Rb chloride at 10 MBq/kg followed by a 10-min dynamic PET scan. Chest scans at rest were acquired in all subjects, as well as one additional biodistribution scan of the head, neck, abdomen, pelvis or thighs. Chest scans under stress were acquired in 25 of the CAD patients. 82Rb time-integrated activity coefficients were determined in 22 source organs using volume of interest analysis, including corrections for partial-volume losses. The mean time-integrated activity coefficients were used to calculate the whole-body effective dose using tissue weighting factors from the International Commission on Radiological Protection (ICRP) Publications 60 and 103.

Results

A total of 283 organ time-integrated activity coefficients were calculated, with a minimum of four values per source organ. The rest and stress mean effective dose was 0.8 mSv/GBq, according to the most recent ICRP definition. Using 10 MBq/kg for 3D PET imaging, the effective dose to a gender-averaged reference person (60 kg female and 73 kg male) is 1.1 mSv for a complete rest and stress perfusion study. For 2D PET using a typical injected activity of 1.1 to 2.2 GBq each for rest and stress, the effective dose for a complete study is 1.8 to 3.5 mSv.

Conclusion

The current effective dose estimate in CAD patients is four times lower than the values reported previously by the ICRP, and about 35 % lower than previous in vivo studies in young healthy subjects.
Appendix
Available only for authorised users
Literature
1.
go back to reference Task Force Members, Montalescot G, Sechtem U, Achenbach S, Andreotti F, Arden C, et al. 2013 ESC guidelines on the management of stable coronary artery disease: the Task Force on the management of stable coronary artery disease of the European Society of Cardiology. Eur Heart J. 2013;34:2949–3003.CrossRef Task Force Members, Montalescot G, Sechtem U, Achenbach S, Andreotti F, Arden C, et al. 2013 ESC guidelines on the management of stable coronary artery disease: the Task Force on the management of stable coronary artery disease of the European Society of Cardiology. Eur Heart J. 2013;34:2949–3003.CrossRef
2.
go back to reference Mc Ardle BA, Dowsley TF, deKemp RA, Wells GA, Beanlands RS. Does rubidium-82 PET have superior accuracy to SPECT perfusion imaging for the diagnosis of obstructive coronary disease? A systematic review and meta-analysis. J Am Coll Cardiol. 2012;60:1828–37.CrossRefPubMed Mc Ardle BA, Dowsley TF, deKemp RA, Wells GA, Beanlands RS. Does rubidium-82 PET have superior accuracy to SPECT perfusion imaging for the diagnosis of obstructive coronary disease? A systematic review and meta-analysis. J Am Coll Cardiol. 2012;60:1828–37.CrossRefPubMed
3.
go back to reference Tahari AK, Lee A, Rajaram M, Fukushima K, Lodge MA, Lee BC, et al. Absolute myocardial flow quantification with (82)Rb PET/CT: comparison of different software packages and methods. Eur J Nucl Med Mol Imaging. 2014;41:126–35.CrossRefPubMed Tahari AK, Lee A, Rajaram M, Fukushima K, Lodge MA, Lee BC, et al. Absolute myocardial flow quantification with (82)Rb PET/CT: comparison of different software packages and methods. Eur J Nucl Med Mol Imaging. 2014;41:126–35.CrossRefPubMed
5.
go back to reference Senthamizhchelvan S, Bravo PE, Esaias C, Lodge MA, Merrill J, Hobbs RF, et al. Human biodistribution and radiation dosimetry of 82Rb. J Nucl Med. 2010;51:1592–9.CrossRefPubMedCentralPubMed Senthamizhchelvan S, Bravo PE, Esaias C, Lodge MA, Merrill J, Hobbs RF, et al. Human biodistribution and radiation dosimetry of 82Rb. J Nucl Med. 2010;51:1592–9.CrossRefPubMedCentralPubMed
6.
go back to reference Senthamizhchelvan S, Bravo PE, Lodge MA, Merrill J, Bengel FM, Sgouros G. Radiation dosimetry of 82Rb in humans under pharmacologic stress. J Nucl Med. 2011;52:485–91.CrossRefPubMedCentralPubMed Senthamizhchelvan S, Bravo PE, Lodge MA, Merrill J, Bengel FM, Sgouros G. Radiation dosimetry of 82Rb in humans under pharmacologic stress. J Nucl Med. 2011;52:485–91.CrossRefPubMedCentralPubMed
7.
go back to reference ICRP Publication 80: Radiation dose to patients from radiopharmaceuticals (addendum 2 to ICRP publication 53). Ann ICRP. 1998;28:1–126. ICRP Publication 80: Radiation dose to patients from radiopharmaceuticals (addendum 2 to ICRP publication 53). Ann ICRP. 1998;28:1–126.
8.
go back to reference Kearfott KJ. Radiation absorbed dose estimates for positron emission tomography (PET): K-38, Rb-81, Rb-82, and Cs-130. J Nucl Med. 1982;23:1128–32.PubMed Kearfott KJ. Radiation absorbed dose estimates for positron emission tomography (PET): K-38, Rb-81, Rb-82, and Cs-130. J Nucl Med. 1982;23:1128–32.PubMed
9.
go back to reference Leggett RW, Williams LR. A proposed blood circulation model for Reference Man. Health Phys. 1995;69:187–201.CrossRefPubMed Leggett RW, Williams LR. A proposed blood circulation model for Reference Man. Health Phys. 1995;69:187–201.CrossRefPubMed
10.
go back to reference Klocke FJ, Baird MG, Lorell BH, Bateman TM, Messer JV, Berman DS, et al. ACC/AHA/ASNC guidelines for the clinical use of cardiac radionuclide imaging--executive summary: a report of the American College of Cardiology/American Heart Association Task Force on Practice Guidelines (ACC/AHA/ASNC Committee to Revise the 1995 Guidelines for the Clinical Use of Cardiac Radionuclide Imaging). Circulation. 2003;108:1404–18.CrossRefPubMed Klocke FJ, Baird MG, Lorell BH, Bateman TM, Messer JV, Berman DS, et al. ACC/AHA/ASNC guidelines for the clinical use of cardiac radionuclide imaging--executive summary: a report of the American College of Cardiology/American Heart Association Task Force on Practice Guidelines (ACC/AHA/ASNC Committee to Revise the 1995 Guidelines for the Clinical Use of Cardiac Radionuclide Imaging). Circulation. 2003;108:1404–18.CrossRefPubMed
11.
go back to reference Klein R, Adler A. Precision-controlled elution of a 82Sr/82Rb generator for cardiac perfusion imaging with positron emission tomography. Phys Med Biol. 2007;52:659–73.CrossRefPubMed Klein R, Adler A. Precision-controlled elution of a 82Sr/82Rb generator for cardiac perfusion imaging with positron emission tomography. Phys Med Biol. 2007;52:659–73.CrossRefPubMed
12.
go back to reference Kemp BJ, Kim C, Williams JJ, Ganin A, Lowe VJ. NEMA NU 2-2001 performance measurements of an LYSO-based PET/CT system in 2D and 3D acquisition modes. J Nucl Med. 2006;47:1960–7.PubMed Kemp BJ, Kim C, Williams JJ, Ganin A, Lowe VJ. NEMA NU 2-2001 performance measurements of an LYSO-based PET/CT system in 2D and 3D acquisition modes. J Nucl Med. 2006;47:1960–7.PubMed
13.
go back to reference Menzel HG, Clement C, DeLuca P. ICRP publication 110. Realistic reference phantoms: an ICRP/ICRU joint effort. A report of adult reference computational phantoms. Ann ICRP. 2009;39:1–164.CrossRefPubMed Menzel HG, Clement C, DeLuca P. ICRP publication 110. Realistic reference phantoms: an ICRP/ICRU joint effort. A report of adult reference computational phantoms. Ann ICRP. 2009;39:1–164.CrossRefPubMed
14.
go back to reference Stabin MG, Sparks RB, Crowe E. OLINDA/EXM: the second-generation personal computer software for internal dose assessment in nuclear medicine. J Nucl Med. 2005;46:1023–7.PubMed Stabin MG, Sparks RB, Crowe E. OLINDA/EXM: the second-generation personal computer software for internal dose assessment in nuclear medicine. J Nucl Med. 2005;46:1023–7.PubMed
15.
go back to reference ICRP Publication 103: The 2007 Recommendations of the International Commission on Radiological Protection. Ann ICRP. 2007;37:1–332. ICRP Publication 103: The 2007 Recommendations of the International Commission on Radiological Protection. Ann ICRP. 2007;37:1–332.
16.
go back to reference 1990 Recommendations of the International Commission on Radiological Protection. Ann ICRP. 1991;21(1–3):1–201. 1990 Recommendations of the International Commission on Radiological Protection. Ann ICRP. 1991;21(1–3):1–201.
17.
18.
go back to reference Duan Y, Lockwood J, Wei L, Hunter C, Soueidan K, Bensimon C, et al. Biodistribution and radiodosimetry of a novel myocardial perfusion tracer 123I-CMICE-013 in healthy rats. EJNMMI Res. 2014;4:16.CrossRefPubMedCentralPubMed Duan Y, Lockwood J, Wei L, Hunter C, Soueidan K, Bensimon C, et al. Biodistribution and radiodosimetry of a novel myocardial perfusion tracer 123I-CMICE-013 in healthy rats. EJNMMI Res. 2014;4:16.CrossRefPubMedCentralPubMed
19.
go back to reference ICRP Publication 53: Radiation dose to patients from radiopharmaceuticals. Ann. ICRP. 1987;18(1–4):1–377. ICRP Publication 53: Radiation dose to patients from radiopharmaceuticals. Ann. ICRP. 1987;18(1–4):1–377.
20.
go back to reference Spector WS. Handbook of biological data. Phildelphia: Saunders; 1956 Spector WS. Handbook of biological data. Phildelphia: Saunders; 1956
21.
go back to reference Ryan JW, Harper PV, Stark VS, Peterson EL, Lathrop KA. Radiation absorbed dose estimates for rubidium-82 determined from in vivo measurements in human subjects. Proceedings of the Fourth International Radiopharmaceutical Dosimetry Symposium, Oak Ridge, Tennessee, 5–8 November 1985. p. 346–58. Ryan JW, Harper PV, Stark VS, Peterson EL, Lathrop KA. Radiation absorbed dose estimates for rubidium-82 determined from in vivo measurements in human subjects. Proceedings of the Fourth International Radiopharmaceutical Dosimetry Symposium, Oak Ridge, Tennessee, 5–8 November 1985. p. 346–58.
22.
go back to reference Hesse B, Tagil K, Cuocolo A, Anagnostopoulos C, Bardies M, Bax J, et al. EANM/ESC procedural guidelines for myocardial perfusion imaging in nuclear cardiology. Eur J Nucl Med Mol Imaging. 2005;32:855–97.CrossRefPubMed Hesse B, Tagil K, Cuocolo A, Anagnostopoulos C, Bardies M, Bax J, et al. EANM/ESC procedural guidelines for myocardial perfusion imaging in nuclear cardiology. Eur J Nucl Med Mol Imaging. 2005;32:855–97.CrossRefPubMed
24.
go back to reference Dorbala S, Di Carli MF, Delbeke D, Abbara S, DePuey EG, Dilsizian V, et al. SNMMI/ASNC/SCCT guideline for cardiac SPECT/CT and PET/CT 1.0. J Nucl Med. 2013;54:1485–507.CrossRefPubMed Dorbala S, Di Carli MF, Delbeke D, Abbara S, DePuey EG, Dilsizian V, et al. SNMMI/ASNC/SCCT guideline for cardiac SPECT/CT and PET/CT 1.0. J Nucl Med. 2013;54:1485–507.CrossRefPubMed
Metadata
Title
Biodistribution and radiation dosimetry of 82Rb at rest and during peak pharmacological stress in patients referred for myocardial perfusion imaging
Authors
Chad R. R. N. Hunter
Jeremy Hill
M. Cecilia Ziadi
Rob S. B. Beanlands
Robert A. deKemp
Publication date
01-06-2015
Publisher
Springer Berlin Heidelberg
Published in
European Journal of Nuclear Medicine and Molecular Imaging / Issue 7/2015
Print ISSN: 1619-7070
Electronic ISSN: 1619-7089
DOI
https://doi.org/10.1007/s00259-015-3028-3

Other articles of this Issue 7/2015

European Journal of Nuclear Medicine and Molecular Imaging 7/2015 Go to the issue