01-04-2003 | Original Article

Dual-modality PET/CT imaging: the effect of respiratory motion on combined image quality in clinical oncology

Authors: Thomas Beyer, Gerald Antoch, Todd Blodgett, Lutz F. Freudenberg, Tim Akhurst, Stephan Mueller

Published in: European Journal of Nuclear Medicine and Molecular Imaging | Issue 4/2003

Login to get access

Abstract

To reduce potential mis-registration from differences in the breathing pattern between two complementary PET and CT data sets, patients are generally allowed to breathe quietly during a dual-modality scan using a combined PET/CT tomograph. Frequently, however, local mis-registration between the CT and the PET is observed. We have evaluated the appearance, magnitude, and frequency of respiration-induced artefacts in CT images of dual-modality PET/CT studies of 62 patients. Combined PET/CT scans during normal respiration were acquired in 43 subjects using single- or dual-slice CT. Nineteen patients were scanned with a special breathing protocol (limited breath-hold technique) on a single-slice PET/CT tomograph. All subjects were injected with ~370 MBq of FDG, and PET/CT scanning commenced 1 h post injection. The CT images were reconstructed and, after appropriate scaling, used for on-line attenuation correction of the PET emission data. We found that respiration artefacts can occur in the majority of cases if no respiration protocol is used. When applying the limited breath-hold technique, the frequency of severe artefacts in the area of the diaphragm was reduced by half, and the spatial extent of respiration-induced artefacts was reduced by at least 40% compared with the acquisition protocols without any breathing instructions. In conclusion, special breathing protocols are effective and should be used for CT scans as part of combined imaging protocols using a dual-modality PET/CT tomograph. The results of this study can also be applied to multi-slice CT to potentially reduce further breathing artefacts in PET/CT imaging and to improve overall image quality.
Literature
1.
go back to reference Gambhir SS, Czernin J, Schwimmer J, Silverman DHS, Coleman EE, Phelps ME. A tabulated summary of the FDG PET literature. J Nucl Med 2001; 42 (5 Suppl):1S–93S. Gambhir SS, Czernin J, Schwimmer J, Silverman DHS, Coleman EE, Phelps ME. A tabulated summary of the FDG PET literature. J Nucl Med 2001; 42 (5 Suppl):1S–93S.
2.
go back to reference Vansteenkiste JF, Stroobants SG, Dupont PJ, Leyn PRD, Wever WF, Verbeken EK, Nuyts JL, Maes FP, Bogaert JG. FDG-PET scan in potentially operable non-small cell lung cancer: Do anatometabolic PET-CT fusion images improve the localisation of regional lymph node metastasis? Eur J Nucl Med 1998; 25:1495–1501. Vansteenkiste JF, Stroobants SG, Dupont PJ, Leyn PRD, Wever WF, Verbeken EK, Nuyts JL, Maes FP, Bogaert JG. FDG-PET scan in potentially operable non-small cell lung cancer: Do anatometabolic PET-CT fusion images improve the localisation of regional lymph node metastasis? Eur J Nucl Med 1998; 25:1495–1501.
3.
go back to reference Hutton BF, Braun M, Thurfjell L, Lau DYH. Image registration: an essential tool for nuclear medicine. Eur J Nucl Med 2002; 29:559–577. Hutton BF, Braun M, Thurfjell L, Lau DYH. Image registration: an essential tool for nuclear medicine. Eur J Nucl Med 2002; 29:559–577.
4.
go back to reference Woods RP, Grafton ST, Holmes CJ, Cherry SR, Mazziotta JC. Automated image registration. I. General methods and intrasubject, intramodality validation. J Comput Assist Tomogr 1998; 22:139–152. Woods RP, Grafton ST, Holmes CJ, Cherry SR, Mazziotta JC. Automated image registration. I. General methods and intrasubject, intramodality validation. J Comput Assist Tomogr 1998; 22:139–152.
5.
go back to reference Yu JN, Fahey FH, Gage HD, Eades CG, Harkness BA, Pelizzari CA, Keys JW Jr. Intermodality, retrospective image registration in the thorax. J Nucl Med 1995; 36:2333–2338. Yu JN, Fahey FH, Gage HD, Eades CG, Harkness BA, Pelizzari CA, Keys JW Jr. Intermodality, retrospective image registration in the thorax. J Nucl Med 1995; 36:2333–2338.
6.
go back to reference Townsend DW, Cherry S. Combining anatomy and function: the path to true image fusion. Eur Radiol 2001; 11:1968–1974. Townsend DW, Cherry S. Combining anatomy and function: the path to true image fusion. Eur Radiol 2001; 11:1968–1974.
7.
go back to reference Beyer T, Townsend DW, Brun T, Kinahan PE, Charron M, Roddy R, Jerin J, Young J, Nutt R, Byars LG. A combined PET/CT tomograph for clinical oncology. J Nucl Med 2000; 41:1369–1379. Beyer T, Townsend DW, Brun T, Kinahan PE, Charron M, Roddy R, Jerin J, Young J, Nutt R, Byars LG. A combined PET/CT tomograph for clinical oncology. J Nucl Med 2000; 41:1369–1379.
8.
go back to reference Kinahan PE, Townsend DW, Beyer T, Sashin D. Attenuation correction for a combined 3D PET/CT scanner. Med Phys 1998; 25:2046–2053. Kinahan PE, Townsend DW, Beyer T, Sashin D. Attenuation correction for a combined 3D PET/CT scanner. Med Phys 1998; 25:2046–2053.
9.
go back to reference von Schulthess GK. Cost considerations regarding an integrated CT-PET system. Eur Radiol 2000; 10 (Suppl 3):S377–S380. von Schulthess GK. Cost considerations regarding an integrated CT-PET system. Eur Radiol 2000; 10 (Suppl 3):S377–S380.
10.
go back to reference Hoh CK, Hawkins RA, Glaspy JA, Dahlbom M, Tse NY, Hoffman EJ, Schiepers C, Choi Y, Rege S, Nitzsche E, Maddahi J, Phelps ME. Cancer detection with whole-body PET using 2-[18F]fluoro-2-deoxy-d-glucose. J Comput Assist Tomogr 1993; 17:582–589. Hoh CK, Hawkins RA, Glaspy JA, Dahlbom M, Tse NY, Hoffman EJ, Schiepers C, Choi Y, Rege S, Nitzsche E, Maddahi J, Phelps ME. Cancer detection with whole-body PET using 2-[18F]fluoro-2-deoxy-d-glucose. J Comput Assist Tomogr 1993; 17:582–589.
11.
go back to reference Beyer T, Townsend D, Blodgett T. Dual-modality PET/CT tomography for clinical oncology. Q J Nucl Med 2002; 46:24–34. Beyer T, Townsend D, Blodgett T. Dual-modality PET/CT tomography for clinical oncology. Q J Nucl Med 2002; 46:24–34.
12.
go back to reference Goerres GW, Kamel E, Heidelberg T-NH, Schwitter MR, Burger C, von Schulthess GK. PET-CT image co-registration in the thorax: influence of respiration. Eur J Nucl Med 2002; 29:351–360. Goerres GW, Kamel E, Heidelberg T-NH, Schwitter MR, Burger C, von Schulthess GK. PET-CT image co-registration in the thorax: influence of respiration. Eur J Nucl Med 2002; 29:351–360.
13.
go back to reference Beyer T, Townsend D. Dual-modality PET/CT imaging: CT-based attenuation correction in the presence of CT contrast agents. J Nucl Med 2001; 42:56P. Beyer T, Townsend D. Dual-modality PET/CT imaging: CT-based attenuation correction in the presence of CT contrast agents. J Nucl Med 2001; 42:56P.
14.
go back to reference Carney J, Beyer T, Brasse D, Yap J, Townsend D. Clinical PET/CT scanning using oral CT contrast agents. J Nucl Med 2002; 43:57P. Carney J, Beyer T, Brasse D, Yap J, Townsend D. Clinical PET/CT scanning using oral CT contrast agents. J Nucl Med 2002; 43:57P.
15.
go back to reference Meikle SR, Dahlbom M, Cherry SR. Attenuation correction using count-limited transmission data in positron emission tomography. J Nucl Med 1993; 34:143–150. Meikle SR, Dahlbom M, Cherry SR. Attenuation correction using count-limited transmission data in positron emission tomography. J Nucl Med 1993; 34:143–150.
16.
go back to reference Cohade C, Osman M, Wahl RL. Accuracy of PET and CT spatial registration of lung lesions with PET-CT. J Nucl Med 2002; 43:14P–15P. Cohade C, Osman M, Wahl RL. Accuracy of PET and CT spatial registration of lung lesions with PET-CT. J Nucl Med 2002; 43:14P–15P.
17.
go back to reference Nakamoto Y, Cohade C, Osman M, Tatsumi M, Traughber BJ, Marshall LT, Wahl RL. Comparison of size and location of normal upper abdominal organs on PET and CT using PET/CT. J Nucl Med 2002; 43:14P. Nakamoto Y, Cohade C, Osman M, Tatsumi M, Traughber BJ, Marshall LT, Wahl RL. Comparison of size and location of normal upper abdominal organs on PET and CT using PET/CT. J Nucl Med 2002; 43:14P.
18.
go back to reference Osman MM, Cohade C, Nakamoto Y, Wahl RL. Clinically significant inaccurate localization of lesions with PET-CT: frequency in 275 patients. J Nucl Med 2002; 43:32P. Osman MM, Cohade C, Nakamoto Y, Wahl RL. Clinically significant inaccurate localization of lesions with PET-CT: frequency in 275 patients. J Nucl Med 2002; 43:32P.
Metadata
Title
Dual-modality PET/CT imaging: the effect of respiratory motion on combined image quality in clinical oncology
Authors
Thomas Beyer
Gerald Antoch
Todd Blodgett
Lutz F. Freudenberg
Tim Akhurst
Stephan Mueller
Publication date
01-04-2003
Publisher
Springer-Verlag
Published in
European Journal of Nuclear Medicine and Molecular Imaging / Issue 4/2003
Print ISSN: 1619-7070
Electronic ISSN: 1619-7089
DOI
https://doi.org/10.1007/s00259-002-1097-6

Other articles of this Issue 4/2003

European Journal of Nuclear Medicine and Molecular Imaging 4/2003 Go to the issue