Abstract

Purpose

Radiofrequency ablation technique for treatment of OO including ablation time and temperature vary greatly between and within reported studies. This study evaluates the immediate and long-term efficacy and complication rate of a two sequential RFA technique for OO.

Materials and methods

We retrospectively reviewed medical records and attempted interview follow-up for 25 patients treated with RFA for OO. Each treatment included 2 consecutive RFAs at 90 °C for 6 min with inter-ablation cooling to 40 °C and occasional inter-ablation probe adjustment. Additionally, we statistically compared the proportion of successful ablations using the DCRFA technique with published studies that utilized alternative OO ablation procedures.

Results

Long-term follow-up was obtained for 24 patients (96 %). Mean patient age at DCRFA was 17.2 years (range, 2.2–50.0 years). Mean time to follow-up was 60 ± 42 months (range 12–152 months). No acute DCRFA-related complications nor long-term recurrences were reported. All 24 interviewed patients reported partial relief of pre-procedural pain within 1 day of DCRFA and total relief within 1 week of DCRFA. One patient ultimately developed a major late complication (complex regional pain syndrome of the left ankle) after DCRFA of a cuboid lesion. Additionally, the DCRFA success rate was significantly higher when compared to two other published OO RFA treatment results.

Conclusion

DCRFA employing two sequential 6-min cycles is an effective treatment of OO. The 100 % primary success rate, 0 % long-term recurrence rate, and low complication rate compare favorably and may be superior to results of prior reports.
Literature
1.
go back to reference Rosenthal DI, Alexander A, Rosenberg AE, Springfield D. Ablation of osteoid osteomas with a percutaneously placed electrode: a new procedure. Radiology. 1992;183:29–33.CrossRefPubMed Rosenthal DI, Alexander A, Rosenberg AE, Springfield D. Ablation of osteoid osteomas with a percutaneously placed electrode: a new procedure. Radiology. 1992;183:29–33.CrossRefPubMed
2.
go back to reference Rosenthal DI, Springfield DS, Gebhardt MC, Rosenberg AE, Mankin HJ. Osteoid osteoma: percutaneous radio-frequency ablation. Radiology. 1995;197:451–4.CrossRefPubMed Rosenthal DI, Springfield DS, Gebhardt MC, Rosenberg AE, Mankin HJ. Osteoid osteoma: percutaneous radio-frequency ablation. Radiology. 1995;197:451–4.CrossRefPubMed
3.
go back to reference Rimondi E, Mavrogenis AF, Rossi G, et al. Radiofrequency ablation for non-spinal osteoid osteomas in 557 patients. Eur Radiol. 2012;22:181–8.CrossRefPubMed Rimondi E, Mavrogenis AF, Rossi G, et al. Radiofrequency ablation for non-spinal osteoid osteomas in 557 patients. Eur Radiol. 2012;22:181–8.CrossRefPubMed
4.
go back to reference Vanderschueren GM, Taminiau AHM, Obermann WR, van den Berg-Huysmans AA, Bloem JL. Osteoid osteoma: factors for increased risk of unsuccessful thermal coagulation. Radiology. 2004;233:757–62.CrossRefPubMed Vanderschueren GM, Taminiau AHM, Obermann WR, van den Berg-Huysmans AA, Bloem JL. Osteoid osteoma: factors for increased risk of unsuccessful thermal coagulation. Radiology. 2004;233:757–62.CrossRefPubMed
5.
go back to reference Sung K-S, Seo J-G, Shim JS, Lee YS. Computed-tomography-guided percutaneous radiofrequency thermoablation for the treatment of osteoid osteoma: 2 to 5 years follow-up. Int Orthop. 2009;33:215–8.CrossRefPubMedPubMedCentral Sung K-S, Seo J-G, Shim JS, Lee YS. Computed-tomography-guided percutaneous radiofrequency thermoablation for the treatment of osteoid osteoma: 2 to 5 years follow-up. Int Orthop. 2009;33:215–8.CrossRefPubMedPubMedCentral
6.
go back to reference Kjar RA, Powell GJ, Schilcht SM, Smith PJ, Slavin J, Choong PFM. Percutaneous radiofrequency ablation for osteoid osteoma: experience with a new treatment. Med J Aust. 2006;184:563–5.PubMed Kjar RA, Powell GJ, Schilcht SM, Smith PJ, Slavin J, Choong PFM. Percutaneous radiofrequency ablation for osteoid osteoma: experience with a new treatment. Med J Aust. 2006;184:563–5.PubMed
7.
go back to reference Barei DP, Moreau G, Scarborough MT, Neel MD. Percutaneous radiofrequency ablation of osteoid osteoma. Clin Orthop. 2000;115–124. Barei DP, Moreau G, Scarborough MT, Neel MD. Percutaneous radiofrequency ablation of osteoid osteoma. Clin Orthop. 2000;115–124.
8.
go back to reference Rosenthal DI, Hornicek FJ, Torriani M, Gebhardt MC, Mankin HJ. Osteoid osteoma: percutaneous treatment with radiofrequency energy. Radiology. 2003;229:171–5.CrossRefPubMed Rosenthal DI, Hornicek FJ, Torriani M, Gebhardt MC, Mankin HJ. Osteoid osteoma: percutaneous treatment with radiofrequency energy. Radiology. 2003;229:171–5.CrossRefPubMed
9.
go back to reference Torriani M, Rosenthal DI. Percutaneous radiofrequency treatment of osteoid osteoma. Pediatr Radiol. 2002;32:615–8.CrossRefPubMed Torriani M, Rosenthal DI. Percutaneous radiofrequency treatment of osteoid osteoma. Pediatr Radiol. 2002;32:615–8.CrossRefPubMed
10.
go back to reference Lindner NJ, Ozaki T, Roedl R, Gosheger G, Winkelmann W, Wörtler K. Percutaneous radiofrequency ablation in osteoid osteoma. J Bone Joint Surg (Br). 2001;83:391–6.CrossRef Lindner NJ, Ozaki T, Roedl R, Gosheger G, Winkelmann W, Wörtler K. Percutaneous radiofrequency ablation in osteoid osteoma. J Bone Joint Surg (Br). 2001;83:391–6.CrossRef
11.
go back to reference Pinto CH, Taminiau AHM, Vanderschueren GM, Hogendoorn PCW, Bloem JL, Obermann WR. Technical considerations in CT-guided radiofrequency thermal ablation of osteoid osteoma: tricks of the trade. AJR Am J Roentgenol. 2002;179:1633–42.CrossRefPubMed Pinto CH, Taminiau AHM, Vanderschueren GM, Hogendoorn PCW, Bloem JL, Obermann WR. Technical considerations in CT-guided radiofrequency thermal ablation of osteoid osteoma: tricks of the trade. AJR Am J Roentgenol. 2002;179:1633–42.CrossRefPubMed
12.
go back to reference Neumann D, Berka H, Dorn U, Neureiter D, Thaler C. Follow-up of thirty-three computed-tomography-guided percutaneous radiofrequency thermoablations of osteoid osteoma. Int Orthop. 2012;36:811–5.CrossRefPubMedPubMedCentral Neumann D, Berka H, Dorn U, Neureiter D, Thaler C. Follow-up of thirty-three computed-tomography-guided percutaneous radiofrequency thermoablations of osteoid osteoma. Int Orthop. 2012;36:811–5.CrossRefPubMedPubMedCentral
13.
go back to reference Daniilidis K, Martinelli N, Gosheger G, et al. Percutaneous CT-guided radio-frequency ablation of osteoid osteoma of the foot and ankle. Arch Orthop Trauma Surg. 2012;132:1707–10.CrossRefPubMed Daniilidis K, Martinelli N, Gosheger G, et al. Percutaneous CT-guided radio-frequency ablation of osteoid osteoma of the foot and ankle. Arch Orthop Trauma Surg. 2012;132:1707–10.CrossRefPubMed
14.
go back to reference Callstrom MR, York JD, Gaba RC, et al. Research reporting standards for image-guided ablation of bone and soft tissue tumors. J Vasc Interv Radiol JVIR. 2009;20:1527–40.CrossRefPubMed Callstrom MR, York JD, Gaba RC, et al. Research reporting standards for image-guided ablation of bone and soft tissue tumors. J Vasc Interv Radiol JVIR. 2009;20:1527–40.CrossRefPubMed
15.
go back to reference Williamson A, Hoggart B. Pain: a review of three commonly used pain rating scales. J Clin Nurs. 2005;14:798–804.CrossRefPubMed Williamson A, Hoggart B. Pain: a review of three commonly used pain rating scales. J Clin Nurs. 2005;14:798–804.CrossRefPubMed
16.
go back to reference Conover W. Practical nonparametric statistics, 2nd edn. New York: Wiley; 1980. Conover W. Practical nonparametric statistics, 2nd edn. New York: Wiley; 1980.
18.
go back to reference Rehnitz C, Sprengel SD, Lehner B, et al. CT-guided radiofrequency ablation of osteoid osteoma: correlation of clinical outcome and imaging features. Diagn Interv Radiol Ank Turk. 2013;19:330–9. Rehnitz C, Sprengel SD, Lehner B, et al. CT-guided radiofrequency ablation of osteoid osteoma: correlation of clinical outcome and imaging features. Diagn Interv Radiol Ank Turk. 2013;19:330–9.
19.
20.
go back to reference Rosenthal DI, Hornicek FJ, Wolfe MW, Jennings LC, Gebhardt MC, Mankin HJ. Percutaneous radiofrequency coagulation of osteoid osteoma compared with operative treatment. J Bone Joint Surg Am. 1998;80:815–21.PubMed Rosenthal DI, Hornicek FJ, Wolfe MW, Jennings LC, Gebhardt MC, Mankin HJ. Percutaneous radiofrequency coagulation of osteoid osteoma compared with operative treatment. J Bone Joint Surg Am. 1998;80:815–21.PubMed
21.
go back to reference Earhart J, Wellman D, Donaldson J, Chesterton J, King E, Janicki JA. Radiofrequency ablation in the treatment of osteoid osteoma: results and complications. Pediatr Radiol. 2013;43:814–9.CrossRefPubMed Earhart J, Wellman D, Donaldson J, Chesterton J, King E, Janicki JA. Radiofrequency ablation in the treatment of osteoid osteoma: results and complications. Pediatr Radiol. 2013;43:814–9.CrossRefPubMed
22.
go back to reference Bourgault C, Vervoort T, Szymanski C, Chastanet P, Maynou C. Percutaneous CT-guided radiofrequency thermocoagulation in the treatment of osteoid osteoma: a 87 patient series. Orthop Traumatol Surg Res OTSR. 2014;100:323–7.CrossRefPubMed Bourgault C, Vervoort T, Szymanski C, Chastanet P, Maynou C. Percutaneous CT-guided radiofrequency thermocoagulation in the treatment of osteoid osteoma: a 87 patient series. Orthop Traumatol Surg Res OTSR. 2014;100:323–7.CrossRefPubMed
Metadata
Title
Long-term clinical outcomes of dual-cycle radiofrequency ablation technique for treatment of osteoid osteoma
Authors
Salim Abboud
Christos Kosmas
Ronald Novak
Mark Robbin
Publication date
01-05-2016
Publisher
Springer Berlin Heidelberg
Published in
Skeletal Radiology / Issue 5/2016
Print ISSN: 0364-2348
Electronic ISSN: 1432-2161
DOI
https://doi.org/10.1007/s00256-015-2321-3

Other articles of this Issue 5/2016

Skeletal Radiology 5/2016 Go to the issue