Skip to main content
Top
Literature
1.
go back to reference Dillman JR, Serai SD, Miethke AG et al (2020) Comparison of liver T1 relaxation times without and with iron correction in pediatric autoimmune liver disease. Pediatr Radiol 50:935–942CrossRef Dillman JR, Serai SD, Miethke AG et al (2020) Comparison of liver T1 relaxation times without and with iron correction in pediatric autoimmune liver disease. Pediatr Radiol 50:935–942CrossRef
2.
go back to reference Schwimmer JB, Deutsch R, Kahen T et al (2006) Prevalence of fatty liver in children and adolescents. Pediatrics 118:1388CrossRef Schwimmer JB, Deutsch R, Kahen T et al (2006) Prevalence of fatty liver in children and adolescents. Pediatrics 118:1388CrossRef
3.
go back to reference Kelly DA (2017) Paediatric liver disease: lessons for adult practice. Lancet Gastroenterol Hepatol 2:390–392CrossRef Kelly DA (2017) Paediatric liver disease: lessons for adult practice. Lancet Gastroenterol Hepatol 2:390–392CrossRef
4.
go back to reference Tunnicliffe EM, Banerjee R, Pavlides M et al (2017) A model for hepatic fibrosis: the competing effects of cell loss and iron on shortened modified Look-Locker inversion recovery T1 (shMOLLI-T1) in the liver. J Magn Reson Imaging 45:450–462 Tunnicliffe EM, Banerjee R, Pavlides M et al (2017) A model for hepatic fibrosis: the competing effects of cell loss and iron on shortened modified Look-Locker inversion recovery T1 (shMOLLI-T1) in the liver. J Magn Reson Imaging 45:450–462
5.
go back to reference Mozes FE, Tunnicliffe EM, Pavlides M, Robson MD (2016) Influence of fat on liver T1 measurements using modified Look-Locker inversion recovery (MOLLI) methods at 3 T. J Magn Reson Imaging 44:105–111 Mozes FE, Tunnicliffe EM, Pavlides M, Robson MD (2016) Influence of fat on liver T1 measurements using modified Look-Locker inversion recovery (MOLLI) methods at 3 T. J Magn Reson Imaging 44:105–111
6.
go back to reference Hoad CL, Palaniyappan N, Kaye P et al (2015) A study of T1 relaxation time as a measure of liver fibrosis and the influence of confounding histological factors. NMR Biomed 28:706–714CrossRef Hoad CL, Palaniyappan N, Kaye P et al (2015) A study of T1 relaxation time as a measure of liver fibrosis and the influence of confounding histological factors. NMR Biomed 28:706–714CrossRef
7.
go back to reference Stanisz GJ, Odrobina EE, Pun J et al (2005) T1, T2 relaxation and magnetization transfer in tissue at 3T. Magn Reson Med 54:507–512CrossRef Stanisz GJ, Odrobina EE, Pun J et al (2005) T1, T2 relaxation and magnetization transfer in tissue at 3T. Magn Reson Med 54:507–512CrossRef
8.
go back to reference Bachtiar V, Kelly MD, Wilman HR et al (2019) Repeatability and reproducibility of multiparametric magnetic resonance imaging of the liver. PLoS One 14:e0214921CrossRef Bachtiar V, Kelly MD, Wilman HR et al (2019) Repeatability and reproducibility of multiparametric magnetic resonance imaging of the liver. PLoS One 14:e0214921CrossRef
10.
go back to reference Jayaswal ANA, Levick C, Selvaraj EA et al (2020) Prognostic value of multiparametric magnetic resonance imaging, transient elastography and blood-based fibrosis markers in patients with chronic liver disease. Liver Int. https://doi.org/10.1111/liv.14625 Jayaswal ANA, Levick C, Selvaraj EA et al (2020) Prognostic value of multiparametric magnetic resonance imaging, transient elastography and blood-based fibrosis markers in patients with chronic liver disease. Liver Int. https://​doi.​org/​10.​1111/​liv.​14625
11.
go back to reference Dennis A, Mouchti S, Kelly M et al (2020) A composite biomarker using multiparametric magnetic resonance imaging and blood analytes accurately identifies patients with non-alcoholic steatohepatitis and significant fibrosis. Sci Rep 10:15308CrossRef Dennis A, Mouchti S, Kelly M et al (2020) A composite biomarker using multiparametric magnetic resonance imaging and blood analytes accurately identifies patients with non-alcoholic steatohepatitis and significant fibrosis. Sci Rep 10:15308CrossRef
Metadata
Title
Differences between T1 and corrected T1 cannot be attributed to iron-correction only
Authors
Ferenc E. Mózes
Elizabeth M. Tunnicliffe
Publication date
01-03-2021
Publisher
Springer Berlin Heidelberg
Published in
Pediatric Radiology / Issue 3/2021
Print ISSN: 0301-0449
Electronic ISSN: 1432-1998
DOI
https://doi.org/10.1007/s00247-020-04956-y

Other articles of this Issue 3/2021

Pediatric Radiology 3/2021 Go to the issue

Hermes

Hermes