01-01-2020 | Magnetic Resonance Imaging | Original Article

Placement of Reveal LINQ Device in the Left Anterior Axillary Position

Authors: Heather Anderson, Joseph Dearani, M. Yasir Qureshi, Kimberly Holst, Patrick O’Leary, Bryan Cannon, Philip Wackel

Published in: Pediatric Cardiology | Issue 1/2020

Login to get access

Abstract

Implantable loop recorders (ILR) are utilized for long-term rhythm monitoring. Typical placement of the Medtronic Reveal LINQ along the left parasternal border may compromise the quality and/or feasibility of future imaging studies. We sought to evaluate the utility of placing an ILR in the left anterior axillary position and the impact on the quality of cardiac imaging. We reviewed patients from May 2017 to June 2018 who had placement of a Reveal LINQ device in the left anterior axillary position. Demographic, procedural, and clinical data were collected via retrospective review. Cardiac magnetic resonance imaging (MRI) studies were reviewed for image quality after ILR placement. Eight patients met inclusion criteria for this study (median age 6 years, 50% female). Six patients (75%) had an ILR placed in the operating room, while all others were placed in the electrophysiology lab. All patients demonstrated acceptable R waves for diagnostic evaluation (median = 0.85 mV, range 0.24–1.7 mV). Cardiac MRI was obtained in 7 patients following ILR placement with diagnostic image quality and no adverse events. One device was explanted 28 days after placement due to concern for possible infection. No other devices required removal or revision (median follow up duration 11 months, IQR 8–13.5). ILR placement in the left anterior axillary position can record adequate signals in pediatric patients. In addition, axillary ILR device position may allow for completion of cardiac imaging, particularly cardiac MRI, without significant artifacts which is critical for patients with congenital heart disease.
Literature
1.
go back to reference Task Force m, Brignole M, Vardas P, Hoffman E, Huikuri H, Moya A et al (2009) Indications for the use of diagnostic implantable and external ECG loop recorders. Europace 11(5):671–687CrossRef Task Force m, Brignole M, Vardas P, Hoffman E, Huikuri H, Moya A et al (2009) Indications for the use of diagnostic implantable and external ECG loop recorders. Europace 11(5):671–687CrossRef
2.
go back to reference Brignole M, Bellardine Black CL, Thomsen PE, Sutton R, Moya A, Stadler RW et al (2008) Improved arrhythmia detection in implantable loop recorders. J Cardiovasc Electrophysiol 19(9):928–934CrossRef Brignole M, Bellardine Black CL, Thomsen PE, Sutton R, Moya A, Stadler RW et al (2008) Improved arrhythmia detection in implantable loop recorders. J Cardiovasc Electrophysiol 19(9):928–934CrossRef
3.
go back to reference Al Dhahri KN, Potts JE, Chiu CC, Hamilton RM, Sanatani S (2009) Are implantable loop recorders useful in detecting arrhythmias in children with unexplained syncope? Pacing Clin Electrophysiol 32(11):1422–1427CrossRef Al Dhahri KN, Potts JE, Chiu CC, Hamilton RM, Sanatani S (2009) Are implantable loop recorders useful in detecting arrhythmias in children with unexplained syncope? Pacing Clin Electrophysiol 32(11):1422–1427CrossRef
4.
go back to reference Ergul Y, Tanidir IC, Ozyilmaz I, Akdeniz C, Tuzcu V (2015) Evaluation rhythm problems in unexplained syncope etiology with implantable loop recorder. Pediatr Int 57(3):359–366CrossRef Ergul Y, Tanidir IC, Ozyilmaz I, Akdeniz C, Tuzcu V (2015) Evaluation rhythm problems in unexplained syncope etiology with implantable loop recorder. Pediatr Int 57(3):359–366CrossRef
5.
go back to reference Frangini PA, Cecchin F, Jordao L, Martuscello M, Alexander ME, Triedman JK et al (2008) How revealing are insertable loop recorders in pediatrics? Pacing Clin Electrophysiol 31(3):338–343CrossRef Frangini PA, Cecchin F, Jordao L, Martuscello M, Alexander ME, Triedman JK et al (2008) How revealing are insertable loop recorders in pediatrics? Pacing Clin Electrophysiol 31(3):338–343CrossRef
6.
go back to reference Nguyen HH, Law IH, Rudokas MW, Lampe J, Bowman TM, Van Hare GF et al (2017) Reveal LINQ versus Reveal XT implantable loop recorders: intra- and post-procedural comparison. J Pediatr 187:290–294CrossRef Nguyen HH, Law IH, Rudokas MW, Lampe J, Bowman TM, Van Hare GF et al (2017) Reveal LINQ versus Reveal XT implantable loop recorders: intra- and post-procedural comparison. J Pediatr 187:290–294CrossRef
7.
go back to reference Hutchinson LJ, Stuart G, Walsh MA (2015) Implantation of the new Medtronic LINQ loop recorder in an infant with ventricular tachycardia. Cardiol Young 25(6):1221–1223CrossRef Hutchinson LJ, Stuart G, Walsh MA (2015) Implantation of the new Medtronic LINQ loop recorder in an infant with ventricular tachycardia. Cardiol Young 25(6):1221–1223CrossRef
8.
go back to reference Purerfellner H, Sanders P, Pokushalov E, Di Bacco M, Bergemann T, Dekker LR et al (2015) Miniaturized Reveal LINQ insertable cardiac monitoring system: first-in-human experience. Heart Rhythm 12(6):1113–1119CrossRef Purerfellner H, Sanders P, Pokushalov E, Di Bacco M, Bergemann T, Dekker LR et al (2015) Miniaturized Reveal LINQ insertable cardiac monitoring system: first-in-human experience. Heart Rhythm 12(6):1113–1119CrossRef
9.
go back to reference Wiles BM, Illingworth CA, Couzins ML, Roberts PR, Harden SP (2018) A tertiary centre experience of thoracic CT and cardiac MRI scanning in the presence of a Reveal LINQ insertable cardiac monitoring system: a case series review of artefact, patient safety and data preservation. Br J Radiol 91(1086):20170615PubMedPubMedCentral Wiles BM, Illingworth CA, Couzins ML, Roberts PR, Harden SP (2018) A tertiary centre experience of thoracic CT and cardiac MRI scanning in the presence of a Reveal LINQ insertable cardiac monitoring system: a case series review of artefact, patient safety and data preservation. Br J Radiol 91(1086):20170615PubMedPubMedCentral
10.
go back to reference Shen WK, Sheldon RS, Benditt DG, Cohen MI, Forman DE, Goldberger ZD et al (2017) 2017 ACC/AHA/HRS guideline for the evaluation and management of patients with syncope: a report of the American College of Cardiology/American Heart Association Task Force on Clinical Practice Guidelines and the Heart Rhythm Society. Circulation 136(5):e60–e122PubMed Shen WK, Sheldon RS, Benditt DG, Cohen MI, Forman DE, Goldberger ZD et al (2017) 2017 ACC/AHA/HRS guideline for the evaluation and management of patients with syncope: a report of the American College of Cardiology/American Heart Association Task Force on Clinical Practice Guidelines and the Heart Rhythm Society. Circulation 136(5):e60–e122PubMed
11.
go back to reference D’Souza R, Thomas E, Macicek S, Aziz P, Shivapour J, Synder CS (2017) P- and R-wave amplitude sensed by Reveal LINQ loop recorder in pediatric patients. J Innovation Cardiac Rhythm Management 8:2584–2588CrossRef D’Souza R, Thomas E, Macicek S, Aziz P, Shivapour J, Synder CS (2017) P- and R-wave amplitude sensed by Reveal LINQ loop recorder in pediatric patients. J Innovation Cardiac Rhythm Management 8:2584–2588CrossRef
12.
go back to reference Wong GR, Lau DH, Middeldorp ME, Harrington JA, Stolcman S, Wilson L et al (2016) Feasibility and safety of Reveal LINQ insertion in a sterile procedure room versus electrophysiology laboratory. Int J Cardiol 223:13–17CrossRef Wong GR, Lau DH, Middeldorp ME, Harrington JA, Stolcman S, Wilson L et al (2016) Feasibility and safety of Reveal LINQ insertion in a sterile procedure room versus electrophysiology laboratory. Int J Cardiol 223:13–17CrossRef
13.
go back to reference Gunda S, Reddy YM, Pillarisetti J, Koripalli S, Jeffery C, Swope J et al (2015) Initial real world experience with a novel insertable (Reveal LinQ(@Medtronic)) compared to the conventional (Reveal XT(@Medtronic)) implantable loop recorder at a tertiary care center—Points to ponder! Int J Cardiol 191:58–63CrossRef Gunda S, Reddy YM, Pillarisetti J, Koripalli S, Jeffery C, Swope J et al (2015) Initial real world experience with a novel insertable (Reveal LinQ(@Medtronic)) compared to the conventional (Reveal XT(@Medtronic)) implantable loop recorder at a tertiary care center—Points to ponder! Int J Cardiol 191:58–63CrossRef
14.
go back to reference Chaouki AS, Czosek RJ, Spar DS (2016) Missing LINQ: extrusion of a new-generation implantable loop recorder in a child. Cardiol Young 26(7):1445–1447CrossRef Chaouki AS, Czosek RJ, Spar DS (2016) Missing LINQ: extrusion of a new-generation implantable loop recorder in a child. Cardiol Young 26(7):1445–1447CrossRef
15.
go back to reference Krahn AD, Pickett RA, Sakaguchi S, Shaik N, Cao J, Norman HS et al (2014) R-wave sensing in an implantable cardiac monitor without ECG-based preimplant mapping: results from a multicenter clinical trial. Pacing Clin Electrophysiol 37(4):505–511CrossRef Krahn AD, Pickett RA, Sakaguchi S, Shaik N, Cao J, Norman HS et al (2014) R-wave sensing in an implantable cardiac monitor without ECG-based preimplant mapping: results from a multicenter clinical trial. Pacing Clin Electrophysiol 37(4):505–511CrossRef
16.
go back to reference Miracapillo G, Costoli A, Addonisio L, Gemignani L, Manfredini E, Corbucci G et al (2010) Left axillary implantation of loop recorder. Pacing Clin Electrophysiol 33(8):999–1002PubMed Miracapillo G, Costoli A, Addonisio L, Gemignani L, Manfredini E, Corbucci G et al (2010) Left axillary implantation of loop recorder. Pacing Clin Electrophysiol 33(8):999–1002PubMed
17.
go back to reference Kannankeril PJ, Bibeau DA, Fish FA (2004) Feasibility of the inframammary location for insertable loop recorders in young women and girls. Pacing Clin Electrophysiol 27(4):492–494CrossRef Kannankeril PJ, Bibeau DA, Fish FA (2004) Feasibility of the inframammary location for insertable loop recorders in young women and girls. Pacing Clin Electrophysiol 27(4):492–494CrossRef
Metadata
Title
Placement of Reveal LINQ Device in the Left Anterior Axillary Position
Authors
Heather Anderson
Joseph Dearani
M. Yasir Qureshi
Kimberly Holst
Patrick O’Leary
Bryan Cannon
Philip Wackel
Publication date
01-01-2020
Publisher
Springer US
Published in
Pediatric Cardiology / Issue 1/2020
Print ISSN: 0172-0643
Electronic ISSN: 1432-1971
DOI
https://doi.org/10.1007/s00246-019-02242-9

Other articles of this Issue 1/2020

Pediatric Cardiology 1/2020 Go to the issue