Published in: Pediatric Cardiology 8/2016

01-12-2016 | Original Article

The Use and Outcomes of Small, Medium and Large Premounted Stents in Pediatric and Congenital Heart Disease

Authors: Brian A. Boe, Jeffrey D. Zampi, Kurt R. Schumacher, Sunkyung Yu, Aimee K. Armstrong

Published in: Pediatric Cardiology | Issue 8/2016

Login to get access

Abstract

We sought to describe the use and outcomes of small, medium and large premounted stents in patients with congenital heart disease, including incidence of and risk factors for re-intervention and development of in-stent stenosis. Premounted stents offer several advantages over traditional manually crimped bare-metal stents, especially in small patients. There are no data describing the medium-term effectiveness and outcomes of premounted stents in congenital heart disease. We performed a single-center retrospective review of all small, medium and large premounted stents implanted over an 8-year period. Premounted stents were implanted in 71 vessels within 59 patients with a 97 % success rate. Regardless of implantation site, premounted stent implantation resulted in significant improvements in vessel size and pressure gradient (p < 0.0001). Over a median follow-up duration of 3.1 years [interquartile range (IQR) 1.3–5.2], 25 patients (43 %) required re-intervention (18 catheter based, 3 surgical and 4 hybrid) at a median time of 1.4 years (IQR 0.9–3.0) from implant. Factors associated with re-intervention included age ≤1.9 years [hazard ratio (HR) 2.4, p = 0.03], weight ≤11.5 kg (HR 2.5, p = 0.03) and bare-metal premounted stents compared to covered premounted stents (HR 4.2, p = 0.001). In-stent stenosis was diagnosed in 42 % of premounted stents which underwent follow-up angiography. No identified characteristics were associated with in-stent stenosis, including “oversizing” the premounted stent. Small, medium and large premounted stents are effective in treating vascular stenosis in congenital heart disease. Frequent follow-up is required, especially in smaller patients with expected somatic growth, and to evaluate for in-stent stenosis which occurs in nearly half of premounted stents.
Literature
1.
go back to reference O’Laughlin MP, Perry SB, Lock JE, Mullins CE (1991) Use of endovascular stents in congenital heart disease. Circulation 83(6):1923–1939CrossRefPubMed O’Laughlin MP, Perry SB, Lock JE, Mullins CE (1991) Use of endovascular stents in congenital heart disease. Circulation 83(6):1923–1939CrossRefPubMed
3.
go back to reference O’Laughlin MP, Slack MC, Grifka RG, Perry SB, Lock JE, Mullins CE (1993) Implantation and intermediate-term follow-up of stents in congenital heart disease. Circulation 88(2):605–614CrossRefPubMed O’Laughlin MP, Slack MC, Grifka RG, Perry SB, Lock JE, Mullins CE (1993) Implantation and intermediate-term follow-up of stents in congenital heart disease. Circulation 88(2):605–614CrossRefPubMed
4.
go back to reference O’Laughlin MP (1995) Balloon-expandable stenting in pediatric cardiology. J Interv Cardiol 8(5):463–475CrossRefPubMed O’Laughlin MP (1995) Balloon-expandable stenting in pediatric cardiology. J Interv Cardiol 8(5):463–475CrossRefPubMed
5.
go back to reference Shaffer KM, Mullins CE, Grifka RG, O’Laughlin MP, McMahon W, Ing FF, Nihill MR (1998) Intravascular stents in congenital heart disease: short- and long-term results from a large single-center experience. J Am Coll Cardiol 31(3):661–667CrossRefPubMed Shaffer KM, Mullins CE, Grifka RG, O’Laughlin MP, McMahon W, Ing FF, Nihill MR (1998) Intravascular stents in congenital heart disease: short- and long-term results from a large single-center experience. J Am Coll Cardiol 31(3):661–667CrossRefPubMed
6.
go back to reference Okubo M, Benson LN (2001) Intravascular and intracardiac stents used in congenital heart disease. Curr Opin Cardiol 16(2):84–91CrossRefPubMed Okubo M, Benson LN (2001) Intravascular and intracardiac stents used in congenital heart disease. Curr Opin Cardiol 16(2):84–91CrossRefPubMed
8.
go back to reference Stanfill R, Nykanen DG, Osorio S, Whalen R, Burke RP, Zahn EM (2008) Stent implantation is effective treatment of vascular stenosis in young infants with congenital heart disease: acute implantation and long-term follow-up results. Catheter Cardiovasc Interv 71(6):831–841. doi:10.1002/ccd.21526 CrossRefPubMed Stanfill R, Nykanen DG, Osorio S, Whalen R, Burke RP, Zahn EM (2008) Stent implantation is effective treatment of vascular stenosis in young infants with congenital heart disease: acute implantation and long-term follow-up results. Catheter Cardiovasc Interv 71(6):831–841. doi:10.​1002/​ccd.​21526 CrossRefPubMed
11.
go back to reference Hascoet S, Jalal Z, Baruteau A, Mauri L, Chalard A, Bouzguenda I, Piechaud JF, Thambo JB, Lefort B, Guerin P, Le Gloan L, Acar P, Houeijeh A, Godart F, Fraisse A (2015) Stenting in paediatric and adult congenital heart diseases: a French multicentre study in the current era. Arch Cardiovasc Dis. doi:10.1016/j.acvd.2015.07.002 Hascoet S, Jalal Z, Baruteau A, Mauri L, Chalard A, Bouzguenda I, Piechaud JF, Thambo JB, Lefort B, Guerin P, Le Gloan L, Acar P, Houeijeh A, Godart F, Fraisse A (2015) Stenting in paediatric and adult congenital heart diseases: a French multicentre study in the current era. Arch Cardiovasc Dis. doi:10.​1016/​j.​acvd.​2015.​07.​002
13.
go back to reference Quandt D, Ramchandani B, Bhole V, Penford G, Mehta C, Dhillon R, Stumper O (2015) Initial experience with the cook formula balloon expandable stent in congenital heart disease. Catheter Cardiovasc Interv 85(2):259–266. doi:10.1002/ccd.25543 CrossRefPubMed Quandt D, Ramchandani B, Bhole V, Penford G, Mehta C, Dhillon R, Stumper O (2015) Initial experience with the cook formula balloon expandable stent in congenital heart disease. Catheter Cardiovasc Interv 85(2):259–266. doi:10.​1002/​ccd.​25543 CrossRefPubMed
14.
go back to reference Stern HJ, Baird CW (2009) A premounted stent that can be implanted in infants and re-dilated to 20 mm: introducing the Edwards Valeo Lifestent. Catheter Cardiovasc Interv 74(6):905–912. doi:10.1002/ccd.22096 CrossRefPubMed Stern HJ, Baird CW (2009) A premounted stent that can be implanted in infants and re-dilated to 20 mm: introducing the Edwards Valeo Lifestent. Catheter Cardiovasc Interv 74(6):905–912. doi:10.​1002/​ccd.​22096 CrossRefPubMed
15.
go back to reference Butera G, Giugno L, Basile D, Piazza L, Chessa M, Carminati M (2015) The Edwards Valeo lifestents in the treatment and palliation of congenital heart disease in infants and small children. Catheter Cardiovasc Interv 86(3):432–437. doi:10.1002/ccd.25872 CrossRefPubMed Butera G, Giugno L, Basile D, Piazza L, Chessa M, Carminati M (2015) The Edwards Valeo lifestents in the treatment and palliation of congenital heart disease in infants and small children. Catheter Cardiovasc Interv 86(3):432–437. doi:10.​1002/​ccd.​25872 CrossRefPubMed
16.
go back to reference van Gameren M, Witsenburg M, Takkenberg JJ, Boshoff D, Mertens L, van Oort AM, de Wolf D, Freund M, Sreeram N, Bokenkamp R, Talsma MD, Gewillig M (2006) Early complications of stenting in patients with congenital heart disease: a multicentre study. Eur Heart J 27(22):2709–2715. doi:10.1093/eurheartj/ehl328 CrossRefPubMed van Gameren M, Witsenburg M, Takkenberg JJ, Boshoff D, Mertens L, van Oort AM, de Wolf D, Freund M, Sreeram N, Bokenkamp R, Talsma MD, Gewillig M (2006) Early complications of stenting in patients with congenital heart disease: a multicentre study. Eur Heart J 27(22):2709–2715. doi:10.​1093/​eurheartj/​ehl328 CrossRefPubMed
17.
go back to reference Meadows J, Teitel D, Moore P (2010) Anatomic and technical predictors of stent malposition during implantation for vascular obstruction in patients with congenital and acquired heart disease. JACC Cardiovasc Interv 3(10):1080–1086. doi:10.1016/j.jcin.2010.07.010 CrossRefPubMed Meadows J, Teitel D, Moore P (2010) Anatomic and technical predictors of stent malposition during implantation for vascular obstruction in patients with congenital and acquired heart disease. JACC Cardiovasc Interv 3(10):1080–1086. doi:10.​1016/​j.​jcin.​2010.​07.​010 CrossRefPubMed
19.
go back to reference Ing FF, Grifka RG, Nihill MR, Mullins CE (1995) Repeat dilation of intravascular stents in congenital heart defects. Circulation 92(4):893–897CrossRefPubMed Ing FF, Grifka RG, Nihill MR, Mullins CE (1995) Repeat dilation of intravascular stents in congenital heart defects. Circulation 92(4):893–897CrossRefPubMed
20.
go back to reference Fogelman R, Nykanen D, Smallhorn JF, McCrindle BW, Freedom RM, Benson LN (1995) Endovascular stents in the pulmonary circulation. Clinical impact on management and medium-term follow-up. Circulation 92(4):881–885CrossRefPubMed Fogelman R, Nykanen D, Smallhorn JF, McCrindle BW, Freedom RM, Benson LN (1995) Endovascular stents in the pulmonary circulation. Clinical impact on management and medium-term follow-up. Circulation 92(4):881–885CrossRefPubMed
21.
go back to reference McMahon CJ, El-Said HG, Grifka RG, Fraley JK, Nihill MR, Mullins CE (2001) Redilation of endovascular stents in congenital heart disease: factors implicated in the development of restenosis and neointimal proliferation. J Am Coll Cardiol 38(2):521–526CrossRefPubMed McMahon CJ, El-Said HG, Grifka RG, Fraley JK, Nihill MR, Mullins CE (2001) Redilation of endovascular stents in congenital heart disease: factors implicated in the development of restenosis and neointimal proliferation. J Am Coll Cardiol 38(2):521–526CrossRefPubMed
23.
24.
go back to reference Holzer RJ, Gauvreau K, Kreutzer J, Leahy R, Murphy J, Lock JE, Cheatham JP, Bergersen L (2011) Balloon angioplasty and stenting of branch pulmonary arteries: adverse events and procedural characteristics: results of a multi-institutional registry. Circ Cardiovasc Interv 4(3):287–296. doi:10.1161/CIRCINTERVENTIONS.110.961029 CrossRefPubMed Holzer RJ, Gauvreau K, Kreutzer J, Leahy R, Murphy J, Lock JE, Cheatham JP, Bergersen L (2011) Balloon angioplasty and stenting of branch pulmonary arteries: adverse events and procedural characteristics: results of a multi-institutional registry. Circ Cardiovasc Interv 4(3):287–296. doi:10.​1161/​CIRCINTERVENTION​S.​110.​961029 CrossRefPubMed
25.
go back to reference Kudumula V, Noonan P, Taliotis D, Duke C (2014) Implantation and preliminary follow-up of the Bard Valeo stent in pulmonary artery stenosis. Catheter Cardiovasc Interv 84(2):197–203. doi:10.1002/ccd.25443 CrossRefPubMed Kudumula V, Noonan P, Taliotis D, Duke C (2014) Implantation and preliminary follow-up of the Bard Valeo stent in pulmonary artery stenosis. Catheter Cardiovasc Interv 84(2):197–203. doi:10.​1002/​ccd.​25443 CrossRefPubMed
26.
go back to reference Jacobs JP, Mavroudis C, Quintessenza JA, Chai PJ, Pasquali SK, Hill KD, Vricella LA, Jacobs ML, Dearani JA, Cameron D (2014) Reoperations for pediatric and congenital heart disease: an analysis of the Society of Thoracic Surgeons (STS) congenital heart surgery database. Semin Thorac Cardiovasc Surg Pediatr Card Surg Annu 17(1):2–8. doi:10.1053/j.pcsu.2014.01.006 CrossRefPubMedPubMedCentral Jacobs JP, Mavroudis C, Quintessenza JA, Chai PJ, Pasquali SK, Hill KD, Vricella LA, Jacobs ML, Dearani JA, Cameron D (2014) Reoperations for pediatric and congenital heart disease: an analysis of the Society of Thoracic Surgeons (STS) congenital heart surgery database. Semin Thorac Cardiovasc Surg Pediatr Card Surg Annu 17(1):2–8. doi:10.​1053/​j.​pcsu.​2014.​01.​006 CrossRefPubMedPubMedCentral
27.
go back to reference Dearani JA, Connolly HM, Martinez R, Fontanet H, Webb GD (2007) Caring for adults with congenital cardiac disease: successes and challenges for 2007 and beyond. Cardiol Young 17(Suppl 2):87–96. doi:10.1017/S1047951107001199 PubMed Dearani JA, Connolly HM, Martinez R, Fontanet H, Webb GD (2007) Caring for adults with congenital cardiac disease: successes and challenges for 2007 and beyond. Cardiol Young 17(Suppl 2):87–96. doi:10.​1017/​S104795110700119​9 PubMed
28.
29.
go back to reference Cunningham JW, McElhinney DB, Gauvreau K, Bergersen L, Lacro RV, Marshall AC, Smoot L, Lock JE (2013) Outcomes after primary transcatheter therapy in infants and young children with severe bilateral peripheral pulmonary artery stenosis. Circ Cardiovasc Interv 6(4):460–467. doi:10.1161/CIRCINTERVENTIONS.112.000061 CrossRefPubMed Cunningham JW, McElhinney DB, Gauvreau K, Bergersen L, Lacro RV, Marshall AC, Smoot L, Lock JE (2013) Outcomes after primary transcatheter therapy in infants and young children with severe bilateral peripheral pulmonary artery stenosis. Circ Cardiovasc Interv 6(4):460–467. doi:10.​1161/​CIRCINTERVENTION​S.​112.​000061 CrossRefPubMed
31.
32.
go back to reference Butera G, Manica JL, Marini D, Piazza L, Chessa M, Filho RI, Sarmento Leite RE, Carminati M (2014) From bare to covered: 15-year single center experience and follow-up in trans-catheter stent implantation for aortic coarctation. Catheter Cardiovasc Interv 83(6):953–963. doi:10.1002/ccd.25404 CrossRefPubMed Butera G, Manica JL, Marini D, Piazza L, Chessa M, Filho RI, Sarmento Leite RE, Carminati M (2014) From bare to covered: 15-year single center experience and follow-up in trans-catheter stent implantation for aortic coarctation. Catheter Cardiovasc Interv 83(6):953–963. doi:10.​1002/​ccd.​25404 CrossRefPubMed
Metadata
Title
The Use and Outcomes of Small, Medium and Large Premounted Stents in Pediatric and Congenital Heart Disease
Authors
Brian A. Boe
Jeffrey D. Zampi
Kurt R. Schumacher
Sunkyung Yu
Aimee K. Armstrong
Publication date
01-12-2016
Publisher
Springer US
Published in
Pediatric Cardiology / Issue 8/2016
Print ISSN: 0172-0643
Electronic ISSN: 1432-1971
DOI
https://doi.org/10.1007/s00246-016-1466-8

Other articles of this Issue 8/2016

Pediatric Cardiology 8/2016 Go to the issue