Skip to main content
Top
Published in: Pediatric Cardiology 6/2008

01-11-2008 | Review

Echocardiography and the Neonatologist

Authors: M. Kluckow, I. Seri, N. Evans

Published in: Pediatric Cardiology | Issue 6/2008

Login to get access

Abstract

Pediatric echocardiography as performed and interpreted by pediatric cardiologists provides details of cardiac structure and function as well as hemodynamic data. Functional echocardiography, in contrast to echocardiography as performed by the cardiologist, is the bedside use of cardiac ultrasound to follow functional and hemodynamic changes longitudinally. Data reflecting cardiac function and systemic and pulmonary blood flow in critically ill preterm and term neonates can be monitored using this method. Functional echocardiography is being developed and driven by neonatologists as an extension of their clinical skills. A wealth of hemodynamic information can be derived from functional echocardiography used for the sick neonate, which provides clinical information different from the assumed underlying physiology. Lack of access to appropriate training programs and interdisciplinary politics is limiting the use of this potentially valuable clinical information. Without the use of functional echocardiography, clinicians are left to speculate as to the underlying pathophysiology of circulatory compromise, and the assumptions they make often are incorrect. For functional echocardiography to fulfill its clinical potential, it needs to be available at any time and at short notice in the neonatal intensive care unit (NICU). Because most NICUs do not have external diagnostic services to provide longitudinal hemodynamic follow-up assessment at the bedside, neonatologists should be able to develop appropriate echocardiographic skills in close collaboration with their cardiologist colleagues.
Literature
1.
go back to reference Althouse LA, Stockman JAIII (2006) Pediatric workforce: a look at pediatric cardiology data from the American Board of Pediatrics. J Pediatr 148:384–385PubMedCrossRef Althouse LA, Stockman JAIII (2006) Pediatric workforce: a look at pediatric cardiology data from the American Board of Pediatrics. J Pediatr 148:384–385PubMedCrossRef
3.
go back to reference Beaulieu Y (2007) Bedside echocardiography in the assessment of the critically ill. Crit Care Med 35:S235–S249PubMedCrossRef Beaulieu Y (2007) Bedside echocardiography in the assessment of the critically ill. Crit Care Med 35:S235–S249PubMedCrossRef
4.
go back to reference Beaulieu Y (2007) Specific skill set and goals of focused echocardiography for critical care clinicians. Crit Care Med 35:S144–S149PubMedCrossRef Beaulieu Y (2007) Specific skill set and goals of focused echocardiography for critical care clinicians. Crit Care Med 35:S144–S149PubMedCrossRef
5.
go back to reference Dorfman AL, Levine JC, Colan SD, Geva T (2005) Accuracy of echocardiography in low-birth-weight infants with congenital heart disease. Pediatrics 115:102–107PubMed Dorfman AL, Levine JC, Colan SD, Geva T (2005) Accuracy of echocardiography in low-birth-weight infants with congenital heart disease. Pediatrics 115:102–107PubMed
6.
go back to reference Evans N (2000) Echocardiography on neonatal intensive care units in Australia and New Zealand. J Paediatr Child Health 36:169–171PubMedCrossRef Evans N (2000) Echocardiography on neonatal intensive care units in Australia and New Zealand. J Paediatr Child Health 36:169–171PubMedCrossRef
7.
go back to reference Evans N, Kluckow M, Currie A (1998) Range of echocardiographic findings in term neonates with high oxygen requirements. Arch Dis Child Fetal Neonatal Ed 78:F105–F111PubMed Evans N, Kluckow M, Currie A (1998) Range of echocardiographic findings in term neonates with high oxygen requirements. Arch Dis Child Fetal Neonatal Ed 78:F105–F111PubMed
8.
go back to reference Evans N, Malcolm G (2006) Practical echocardiography for the neonatologist: Part 1. Normal 2D imaging and Doppler: an interactive multimedia CD-ROM. Royal Prince Alfred Hospital, Sydney, Australia Evans N, Malcolm G (2006) Practical echocardiography for the neonatologist: Part 1. Normal 2D imaging and Doppler: an interactive multimedia CD-ROM. Royal Prince Alfred Hospital, Sydney, Australia
9.
go back to reference Katumba-Lunyenya JL (2002) Neonatal/infant echocardiography by the noncardiologist: a personal practice, past, present, and future. Arch Dis Child Fetal Neonatal Ed 86:F55–F57PubMedCrossRef Katumba-Lunyenya JL (2002) Neonatal/infant echocardiography by the noncardiologist: a personal practice, past, present, and future. Arch Dis Child Fetal Neonatal Ed 86:F55–F57PubMedCrossRef
10.
go back to reference Kluckow M (2005) Low systemic blood flow and pathophysiology of the preterm transitional circulation. Early Hum Dev 81:429–437PubMedCrossRef Kluckow M (2005) Low systemic blood flow and pathophysiology of the preterm transitional circulation. Early Hum Dev 81:429–437PubMedCrossRef
11.
go back to reference Kluckow M, Evans N (1995) Early echocardiographic prediction of symptomatic patent ductus arteriosus in preterm infants undergoing mechanical ventilation. J Pediatr 127:774–779PubMedCrossRef Kluckow M, Evans N (1995) Early echocardiographic prediction of symptomatic patent ductus arteriosus in preterm infants undergoing mechanical ventilation. J Pediatr 127:774–779PubMedCrossRef
12.
go back to reference Kluckow M, Evans N (1996) Relationship between blood pressure and cardiac output in preterm infants requiring mechanical ventilation. J Pediatr 129:506–512PubMedCrossRef Kluckow M, Evans N (1996) Relationship between blood pressure and cardiac output in preterm infants requiring mechanical ventilation. J Pediatr 129:506–512PubMedCrossRef
13.
go back to reference Kluckow M, Seri I, Evans N (2007) Functional echocardiography: an emerging clinical tool for the neonatologist. J Pediatr 150:125–130PubMedCrossRef Kluckow M, Seri I, Evans N (2007) Functional echocardiography: an emerging clinical tool for the neonatologist. J Pediatr 150:125–130PubMedCrossRef
14.
go back to reference Levene MI, Fawer CL, Lamont RF (1982) Risk factors in the development of intraventricular haemorrhage in the preterm neonate. Arch Dis Child 57:410–417PubMed Levene MI, Fawer CL, Lamont RF (1982) Risk factors in the development of intraventricular haemorrhage in the preterm neonate. Arch Dis Child 57:410–417PubMed
15.
go back to reference Moss S, Kitchiner DJ, Yoxall CW, Subhedar NV (2003) Evaluation of echocardiography on the neonatal unit. Arch Dis Child Fetal Neonatal Ed 88:F287–F289PubMedCrossRef Moss S, Kitchiner DJ, Yoxall CW, Subhedar NV (2003) Evaluation of echocardiography on the neonatal unit. Arch Dis Child Fetal Neonatal Ed 88:F287–F289PubMedCrossRef
16.
go back to reference Osborn DA, Evans N, Kluckow M (2004) Clinical detection of low upper body blood flow in very premature infants using blood pressure, capillary refill time, and central-peripheral temperature difference. Arch Dis Child Fetal Neonatal Ed 89:F168–F173PubMedCrossRef Osborn DA, Evans N, Kluckow M (2004) Clinical detection of low upper body blood flow in very premature infants using blood pressure, capillary refill time, and central-peripheral temperature difference. Arch Dis Child Fetal Neonatal Ed 89:F168–F173PubMedCrossRef
17.
go back to reference Seri I (2004) Hemodynamics during the first two postnatal days and neurodevelopment in preterm neonates. J Pediatr 145:573–575PubMedCrossRef Seri I (2004) Hemodynamics during the first two postnatal days and neurodevelopment in preterm neonates. J Pediatr 145:573–575PubMedCrossRef
18.
go back to reference Sholler G (2001) Echocardiography in congenital heart disease: diagnosis, misdiagnosis, and ownership. J Paediatr Child Health 37:321–322PubMedCrossRef Sholler G (2001) Echocardiography in congenital heart disease: diagnosis, misdiagnosis, and ownership. J Paediatr Child Health 37:321–322PubMedCrossRef
19.
go back to reference Skinner JR (1998) Echocardiography on the neonatal unit: a job for the neonatologist or the cardiologist? Arch Dis Child 78:401–402PubMed Skinner JR (1998) Echocardiography on the neonatal unit: a job for the neonatologist or the cardiologist? Arch Dis Child 78:401–402PubMed
20.
go back to reference Skinner JR, Alverson DC, Hunter S (2000) Echocardiography for the neonatologist. Churchill Livingstone, Oxford, London Skinner JR, Alverson DC, Hunter S (2000) Echocardiography for the neonatologist. Churchill Livingstone, Oxford, London
21.
go back to reference Ward CJ, Purdie J (2001) Diagnostic accuracy of paediatric echocardiograms interpreted by individuals other than paediatric cardiologists. J Paediatr Child Health 37:331–336PubMedCrossRef Ward CJ, Purdie J (2001) Diagnostic accuracy of paediatric echocardiograms interpreted by individuals other than paediatric cardiologists. J Paediatr Child Health 37:331–336PubMedCrossRef
Metadata
Title
Echocardiography and the Neonatologist
Authors
M. Kluckow
I. Seri
N. Evans
Publication date
01-11-2008
Publisher
Springer-Verlag
Published in
Pediatric Cardiology / Issue 6/2008
Print ISSN: 0172-0643
Electronic ISSN: 1432-1971
DOI
https://doi.org/10.1007/s00246-008-9275-3

Other articles of this Issue 6/2008

Pediatric Cardiology 6/2008 Go to the issue