Skip to main content
Top
Published in: Pediatric Cardiology 5/2004

01-09-2004

High Energy External Cardioversion for Refractory Atrial Fibrillation in Postoperative Tetralogy of Fallot

Authors: N. Madan, B. W. Robinson, J. W. Moore, M. C. Sokoloski

Published in: Pediatric Cardiology | Issue 5/2004

Login to get access

Abstract

Long-term complications of surgical repair of Tetralogy of Fallot include atrial arrhythmias. These can be difficult to treat, and loss of sinus rhythm can lead to profound hemodynamic consequences in the presence of residual structural abnormalities. We describe the first report of high-energy external cardioversion in a 46-year-old man with repaired tetralogy of Fallot with atrial fibrillation refractory to conversion with normal energy. This represents an alternative to internal cardioversion or rate control for these patients.
Literature
1.
go back to reference Botto, GL, Politi, A, Bonini, W, et al. 1999External cardioversion of atrial fibrillation: role of paddle position on technical efficacy and energy requirements.Heart82726730PubMed Botto, GL, Politi, A, Bonini, W,  et al. 1999External cardioversion of atrial fibrillation: role of paddle position on technical efficacy and energy requirements.Heart82726730PubMed
2.
go back to reference Connell, PN, Ewy, GA, Dahl, CF, Ewy, MD 1973Transthoracic impedance to defibrillator discharge: effect of electrode size and chest wall interface.J Electrocardr6313M Connell, PN, Ewy, GA, Dahl, CF, Ewy, MD 1973Transthoracic impedance to defibrillator discharge: effect of electrode size and chest wall interface.J Electrocardr6313M
3.
go back to reference Ewy, GA 1977Effectiveness of direct current defibrillation: role of paddle electrode size (letter)Am Heart J93674675PubMed Ewy, GA 1977Effectiveness of direct current defibrillation: role of paddle electrode size (letter)Am Heart J93674675PubMed
4.
go back to reference Garson Jr, A, Randall, DC, Gillette, PC, et al. 1985Prevention of sudden death after Tetralogy of Fallot: treatment of ventricular arrhythmias.J Am Coll Cardiol6221227PubMed Garson Jr, A, Randall, DC, Gillette, PC,  et al. 1985Prevention of sudden death after Tetralogy of Fallot: treatment of ventricular arrhythmias.J Am Coll Cardiol6221227PubMed
5.
go back to reference Gatzoulis, MA, Till, JA, Sommerville, J, Redington, A 1995Mechanoelectrical interaction in Tetralogy of Fallot: QRS prolongation relates to right ventricular size and predicts malignant ventricular arrhythmia and sudden death.Circulation92231237PubMed Gatzoulis, MA, Till, JA, Sommerville, J, Redington, A 1995Mechanoelectrical interaction in Tetralogy of Fallot: QRS prolongation relates to right ventricular size and predicts malignant ventricular arrhythmia and sudden death.Circulation92231237PubMed
6.
go back to reference Harrison, DA, Siu, SC, Hussain, F, et al. 2001Sustained atrial arrhythmias in adults late after repair of Tetralogy of Fallot.Circulation87584588CrossRef Harrison, DA, Siu, SC, Hussain, F,  et al. 2001Sustained atrial arrhythmias in adults late after repair of Tetralogy of Fallot.Circulation87584588CrossRef
7.
go back to reference Kerber, RE, Jensen, SR, Crayzel, J, et al. 1981Elective cardioversion: influence of paddle-electrode location and size on success rate and energy requirements.N Engl J Med.305658 Kerber, RE, Jensen, SR, Crayzel, J,  et al. 1981Elective cardioversion: influence of paddle-electrode location and size on success rate and energy requirements.N Engl J Med.305658
8.
go back to reference Levy, S, Lauribe, P, Dolla, E, et al. 1992Randomized comparison of external and internal cardioversion of chronic atrial fibrillation.Circulation8614151420PubMed Levy, S, Lauribe, P, Dolla, E,  et al. 1992Randomized comparison of external and internal cardioversion of chronic atrial fibrillation.Circulation8614151420PubMed
9.
go back to reference Lown, B 1967Electrical reversion of cardiac arrhythmias.Br Heart J29469489PubMed Lown, B 1967Electrical reversion of cardiac arrhythmias.Br Heart J29469489PubMed
10.
go back to reference Nadkarni, V, Hazinski, MF, Zideman, D, et al. 1997Emergency cardiac care: an advisory statement from the Pediatric Working Group of the International Liason Committee on Resuscitation of the American Heart Association.Circulation9521852195PubMed Nadkarni, V, Hazinski, MF, Zideman, D,  et al. 1997Emergency cardiac care: an advisory statement from the Pediatric Working Group of the International Liason Committee on Resuscitation of the American Heart Association.Circulation9521852195PubMed
11.
go back to reference Ricard, P, Levy, S, Trigano, J, et al. 1997Prospective assessment of the minimum energy needed for external electrical cardioversion of atrial fibrillation.Am J Cardiol79815816CrossRefPubMed Ricard, P, Levy, S, Trigano, J,  et al. 1997Prospective assessment of the minimum energy needed for external electrical cardioversion of atrial fibrillation.Am J Cardiol79815816CrossRefPubMed
12.
go back to reference Roos-Hesslienk, J, Perloth, MG, McGhie, J, Spitaels, S 1995Atrial arrhythmias in adults after repair of Tetralogy of Fallot: correlation with clinical, exercise and echocardiographic findings.Circulation9122142219PubMed Roos-Hesslienk, J, Perloth, MG, McGhie, J, Spitaels, S 1995Atrial arrhythmias in adults after repair of Tetralogy of Fallot: correlation with clinical, exercise and echocardiographic findings.Circulation9122142219PubMed
13.
go back to reference Sahiba, W, Juratli, N, Chung, MK, et al. 1999High energy synchronized external direct current cardioversion for refractory atrial fibrillation.J Am Coll Cardiol3420312034CrossRefPubMed Sahiba, W, Juratli, N, Chung, MK,  et al. 1999High energy synchronized external direct current cardioversion for refractory atrial fibrillation.J Am Coll Cardiol3420312034CrossRefPubMed
14.
go back to reference Theodoro, DA, Danielson, GK, Porter, CJ, Warnes, CA 1998Right-sided maze procedure for right-atrial arrythmias in congenital heart disease.Ann Thorac Surg65149154CrossRefPubMed Theodoro, DA, Danielson, GK, Porter, CJ, Warnes, CA 1998Right-sided maze procedure for right-atrial arrythmias in congenital heart disease.Ann Thorac Surg65149154CrossRefPubMed
15.
go back to reference Thomas, ED, Ewy, GA, Dahl, CF, Ewy, MD 1977Effectiveness of direct current defibrillation: role of paddle electrode size.Am Heart J93463467PubMed Thomas, ED, Ewy, GA, Dahl, CF, Ewy, MD 1977Effectiveness of direct current defibrillation: role of paddle electrode size.Am Heart J93463467PubMed
16.
go back to reference Tuinenberg, AE, Van Gelder, IC, Tieleman, RG, et al. 1997No differences in efficacy in atrial fibrillation of the anterolateral versus anteroposterior paddle position during external DC countershock for atrial arrhythmia (abstract)Eur Heart J18540PubMed Tuinenberg, AE, Van Gelder, IC, Tieleman, RG,  et al. 1997No differences in efficacy in atrial fibrillation of the anterolateral versus anteroposterior paddle position during external DC countershock for atrial arrhythmia (abstract)Eur Heart J18540PubMed
Metadata
Title
High Energy External Cardioversion for Refractory Atrial Fibrillation in Postoperative Tetralogy of Fallot
Authors
N. Madan
B. W. Robinson
J. W. Moore
M. C. Sokoloski
Publication date
01-09-2004
Publisher
Springer-Verlag
Published in
Pediatric Cardiology / Issue 5/2004
Print ISSN: 0172-0643
Electronic ISSN: 1432-1971
DOI
https://doi.org/10.1007/s00246-002-0250-0

Other articles of this Issue 5/2004

Pediatric Cardiology 5/2004 Go to the issue