Skip to main content
Top
Published in: European Journal of Plastic Surgery 5/2015

01-10-2015 | Original Paper

Injection complications and change in keloid height following intralesional injection of lesions: a novel injection system compared with the traditional method

Authors: Bayo Aluko-Olokun, Ademola Abayomi Olaitan, Oluseun Abidemi Aluko-Olokun

Published in: European Journal of Plastic Surgery | Issue 5/2015

Login to get access

Abstract

Background

Injection complications can compromise the accuracy of the dosage of a medication, which is critical to keloid treatment success. This study aims to compare the incidence of injection complications of a metal dental syringe injection system with that of the traditional plastic hypodermic syringe, and the change in keloid height associated with their use in intralesional keloid injection of triamcinolone.

Methods

Complications of the injection systems such as inability to inject due to toughness of the tissue, spillage of the drug following separation of a friction-gripped needle from the syringe, backflow of the drug through the space between the plunger and barrel, bending of the plunger and outright breakage of the injected skin were documented. A visual analogue scale (VAS) was administered to measure pain experienced by patients. Change in height of lesions was documented.

Results

Eighty-eight lesions were injected: 44 were injected using the metal dental syringe system while another 44 were injected using a plastic hypodermic syringe. The metal dental syringe system was involved in fewer incidents of skin breakage and backflow of liquid medication than the traditional. The traditional system was involved in three other complications.
The mean (VAS) pain score of 78 mm was derived for patients injected using the metal dental syringe system, while 71 mm was the corresponding value for the traditional. The keloid flattening rate was greater in the group injected using the metal dental syringe system.

Conclusions

The metal dental syringe delivery system recorded fewer complications during intralesional injection of triamcinolone than the traditional plastic syringe system.
Level of Evidence: Level III, risk/prognostic study.
Literature
1.
go back to reference Oluwasanmi JO (1974) Keloids in the African. Clin Plast Surg 1:179–185PubMed Oluwasanmi JO (1974) Keloids in the African. Clin Plast Surg 1:179–185PubMed
2.
go back to reference Aluko-Olokun B, Olaitan AA, Ladeinde AL, Oginni FO (2014) The facial keloid: a comparison of treatment outcome between intralesional steroid injection and excision combined with radiotherapy. Eur J Plast Surg 37:361–366CrossRef Aluko-Olokun B, Olaitan AA, Ladeinde AL, Oginni FO (2014) The facial keloid: a comparison of treatment outcome between intralesional steroid injection and excision combined with radiotherapy. Eur J Plast Surg 37:361–366CrossRef
3.
go back to reference Shejbal D, Bedekovic V, Ivkic M, Kalogjera L, Aleric Z, Divis P (2004) Strategies in the treatment of keloid and hypertrophic scar. Acta Clin Croat 43:417–422 Shejbal D, Bedekovic V, Ivkic M, Kalogjera L, Aleric Z, Divis P (2004) Strategies in the treatment of keloid and hypertrophic scar. Acta Clin Croat 43:417–422
4.
go back to reference Aluko-Olokun B, Olaitan AA, Ladeinde AL (2014) Sessile and pedunculated facial keloid scar: a comparison of response to intralesional triamcinolone injection. Eur J Plast Surg 37:255–258CrossRef Aluko-Olokun B, Olaitan AA, Ladeinde AL (2014) Sessile and pedunculated facial keloid scar: a comparison of response to intralesional triamcinolone injection. Eur J Plast Surg 37:255–258CrossRef
5.
go back to reference Fitzpatrick RE (1999) Treatment of inflamed hypertrophic scars using intralesional 5-FU. Dermatol Surg 25:224–232CrossRefPubMed Fitzpatrick RE (1999) Treatment of inflamed hypertrophic scars using intralesional 5-FU. Dermatol Surg 25:224–232CrossRefPubMed
6.
go back to reference van de Veire S, Germonpre P, Renier C, Stalmans I, Zeyen T (2008) Influences of atmospheric pressure and temperature on intraocular pressure. Invest Ophthalmol Vis Sci 49:5392–5396CrossRefPubMed van de Veire S, Germonpre P, Renier C, Stalmans I, Zeyen T (2008) Influences of atmospheric pressure and temperature on intraocular pressure. Invest Ophthalmol Vis Sci 49:5392–5396CrossRefPubMed
7.
go back to reference Mendez JVM (2010) Mechanical properties of single keloid and normal skin fibroblast measured using an atomic force microscope. Thesis submitted to The University of Manchester for the degree of Doctor of Philosophy in the Faculty of Engineering and Physical Science, School of Mechanical, Aerospace and Civil Engineering. Manchester Mendez JVM (2010) Mechanical properties of single keloid and normal skin fibroblast measured using an atomic force microscope. Thesis submitted to The University of Manchester for the degree of Doctor of Philosophy in the Faculty of Engineering and Physical Science, School of Mechanical, Aerospace and Civil Engineering. Manchester
9.
go back to reference Kim MS, Yan J, Kang KM, Joo KH, Kang YJ, Ahn SS (2013) Soundproofing ability and mechanical properties of polypropylene/exfoliated graphite nanoplatelet/carbon nanotube (PP/xGnP/CNT) composite. Int J Precis Eng Manuf 14:1087–1092CrossRef Kim MS, Yan J, Kang KM, Joo KH, Kang YJ, Ahn SS (2013) Soundproofing ability and mechanical properties of polypropylene/exfoliated graphite nanoplatelet/carbon nanotube (PP/xGnP/CNT) composite. Int J Precis Eng Manuf 14:1087–1092CrossRef
10.
go back to reference Jam JE, Noorabadi M, Namdaran N, Taghavian H, Mohammadi M, Namdaran N (2013) Effect of fiber volume fraction on stress distribution in polypropylene matrix composites. J Sci Today’s World 2:214–225 Jam JE, Noorabadi M, Namdaran N, Taghavian H, Mohammadi M, Namdaran N (2013) Effect of fiber volume fraction on stress distribution in polypropylene matrix composites. J Sci Today’s World 2:214–225
11.
go back to reference Muneuchi G, Suzuki S, Onodera Y, Ito O, Hata Y, Igawa HH (2006) Long-term outcome of intralesional injection of triamcinolone acetonide for the treatment of keloid scars in Asian patients. Scand J Plast Reconstr Surg Hand Surg 40:111–116CrossRefPubMed Muneuchi G, Suzuki S, Onodera Y, Ito O, Hata Y, Igawa HH (2006) Long-term outcome of intralesional injection of triamcinolone acetonide for the treatment of keloid scars in Asian patients. Scand J Plast Reconstr Surg Hand Surg 40:111–116CrossRefPubMed
12.
go back to reference Sagher U (1989) The intraligamental dental syringe facilitates steroid injection into hypertrophic scars and keloids. Plast Reconstr Surg 84:542CrossRefPubMed Sagher U (1989) The intraligamental dental syringe facilitates steroid injection into hypertrophic scars and keloids. Plast Reconstr Surg 84:542CrossRefPubMed
13.
go back to reference Bijur PE, Silver W, Gallagher EJ (2001) Reliability of the visual analog scale for measurement of acute pain. Acad Emerg Med 8:1153–1157CrossRefPubMed Bijur PE, Silver W, Gallagher EJ (2001) Reliability of the visual analog scale for measurement of acute pain. Acad Emerg Med 8:1153–1157CrossRefPubMed
Metadata
Title
Injection complications and change in keloid height following intralesional injection of lesions: a novel injection system compared with the traditional method
Authors
Bayo Aluko-Olokun
Ademola Abayomi Olaitan
Oluseun Abidemi Aluko-Olokun
Publication date
01-10-2015
Publisher
Springer Berlin Heidelberg
Published in
European Journal of Plastic Surgery / Issue 5/2015
Print ISSN: 0930-343X
Electronic ISSN: 1435-0130
DOI
https://doi.org/10.1007/s00238-015-1105-2

Other articles of this Issue 5/2015

European Journal of Plastic Surgery 5/2015 Go to the issue