Skip to main content
Top
Published in: European Journal of Plastic Surgery 5/2010

01-10-2010 | Original Paper

Combining muscle-splitting biplane with multilayer capsulorrhaphy for the correction of bottoming down following subglandular augmentation

Author: Umar Daraz Khan

Published in: European Journal of Plastic Surgery | Issue 5/2010

Login to get access

Abstract

Implant malplacement is the second most common reason for revision and bottoming down is the most common presentation of implant malplacement. Submuscular biplane relocation was combined with capsulotomies and multilayer capsulorrhaphy when bottoming down was seen following subglandular breast augmentation. Between 2005 and 2009, bottoming down following subglandular mammoplasty was seen in 41 breasts (19 bilateral and three unilateral). Of the 19 patients, 12 had downward transgression of inframammary crease (IMC) alone; this also included a patient with vertical scar mastopexy. Two patients had multiplane malplacements where bottoming down was associated with lateral displacement (telemastia) in one and medial displacement (symmastia) in the other. Two had simultaneous downward transgression of the IMC and nipple areolar complex (NAC) and three had bottoming down with capsular contracture independent of NAC descent. Follow-up of up to 3 1/2 years showed stable IMC and NAC relationship with acceptable results. Dog ear revision was required in one patient when IMC relocation was accompanied with vertical scar mastopexy and one patient needed revision for further relocation and improvement of symmastia. No wound breakdown or periprosthetic infection was seen in their series. Multilayer capsulorrhaphy with submuscular biplane repositioning of implants is a suitable option to correct bottoming down following subglandular augmentation.
Literature
1.
go back to reference Biggs TM, Yarish RS (1990) Augmentation mammoplasty: a comparative analysis. Plast Reconstr Surg 85:368CrossRefPubMed Biggs TM, Yarish RS (1990) Augmentation mammoplasty: a comparative analysis. Plast Reconstr Surg 85:368CrossRefPubMed
2.
go back to reference Spears SL, Little JW III (1988) Breast capsulorraphy. Plast Reconstr Surg 81:274–279CrossRef Spears SL, Little JW III (1988) Breast capsulorraphy. Plast Reconstr Surg 81:274–279CrossRef
3.
go back to reference Millan Mateo J, Vaquero P (2001) Innovative new concepts in augmentative breast surgery. Part II: systematic and drawing. Aesth Plast Surg 25:436–442CrossRef Millan Mateo J, Vaquero P (2001) Innovative new concepts in augmentative breast surgery. Part II: systematic and drawing. Aesth Plast Surg 25:436–442CrossRef
4.
go back to reference Troilius C (1996) Correction of implant ptosis after a transaxillary subpectoral breast augmentation. Plast Reconstr Surg 98:889–895CrossRefPubMed Troilius C (1996) Correction of implant ptosis after a transaxillary subpectoral breast augmentation. Plast Reconstr Surg 98:889–895CrossRefPubMed
5.
go back to reference Tebbetts JB (2001) Dual-plane breast augmentation: optimizing implant–soft tissue relationship in a wide range of breast types. Plast Reconstr Surg 107:1255CrossRefPubMed Tebbetts JB (2001) Dual-plane breast augmentation: optimizing implant–soft tissue relationship in a wide range of breast types. Plast Reconstr Surg 107:1255CrossRefPubMed
6.
go back to reference Khan UD (2006) Lower pole enhancement in breast augmentation. Proceedings of the 6th Croatian Congress of Plastic, Reconstructive and Aesthetic Surgery, Opatja-Rijeka, Croatia Khan UD (2006) Lower pole enhancement in breast augmentation. Proceedings of the 6th Croatian Congress of Plastic, Reconstructive and Aesthetic Surgery, Opatja-Rijeka, Croatia
7.
go back to reference Rowe NM, Freund R (2005) The autologous internal breast splint: a novel technique for the treatment of postaugmentation ptosis. Aesthet Surg J 25:545–664CrossRef Rowe NM, Freund R (2005) The autologous internal breast splint: a novel technique for the treatment of postaugmentation ptosis. Aesthet Surg J 25:545–664CrossRef
8.
go back to reference Clarendon CCD (1988) Implant descent: a complication of augmentation mammoplasty and its correction. Ann Plast Surg 21:452–457CrossRefPubMed Clarendon CCD (1988) Implant descent: a complication of augmentation mammoplasty and its correction. Ann Plast Surg 21:452–457CrossRefPubMed
9.
go back to reference Muntan CD, Sundine MJ, Rink RD, Acland RD (2000) Inframammary fold: a histologic reappraisal. Plast Reconstr Surg 105:549–556CrossRefPubMed Muntan CD, Sundine MJ, Rink RD, Acland RD (2000) Inframammary fold: a histologic reappraisal. Plast Reconstr Surg 105:549–556CrossRefPubMed
10.
go back to reference Last RJ (1978) Anatomy regional and applied, 6th edn. Churchill Livingstone, Edinburgh, pp 65–66 Last RJ (1978) Anatomy regional and applied, 6th edn. Churchill Livingstone, Edinburgh, pp 65–66
11.
go back to reference Barnett A (1990) Transaxillary subpectoral augmentation in the ptotic breast: augmentation by disruption of the extended pectoral fascia and parenchymal sweep. Plast Reconstr Surg 86:76–83CrossRefPubMed Barnett A (1990) Transaxillary subpectoral augmentation in the ptotic breast: augmentation by disruption of the extended pectoral fascia and parenchymal sweep. Plast Reconstr Surg 86:76–83CrossRefPubMed
12.
go back to reference Tebbetts JB (1984) Transaxillary subpectoral augmentation mammoplasty: long-term follow-up and refinements. Plast Reconstr Surg 74:636–647CrossRefPubMed Tebbetts JB (1984) Transaxillary subpectoral augmentation mammoplasty: long-term follow-up and refinements. Plast Reconstr Surg 74:636–647CrossRefPubMed
13.
go back to reference Regnault P (1976) Breast ptosis: definition and treatment. Clin Plast Surg 91:657–662 Regnault P (1976) Breast ptosis: definition and treatment. Clin Plast Surg 91:657–662
14.
go back to reference Khan UD (2007) Muscle splitting biplane breast augmentation. Aesth Plast Surg 31:353–358 Khan UD (2007) Muscle splitting biplane breast augmentation. Aesth Plast Surg 31:353–358
15.
go back to reference Keramidas E, Khan UD (2005) The ballooning manoeuvre in breast augmentation. Plast Reconstr Surg 115:1795–1796CrossRefPubMed Keramidas E, Khan UD (2005) The ballooning manoeuvre in breast augmentation. Plast Reconstr Surg 115:1795–1796CrossRefPubMed
16.
go back to reference Kjoller K, Holmich LR, Jacobsen PH, Friis S, Fryzek J, McLaughlin JK, Lipworth L, Henrikson TF, Jorgensen S, Bittmann S, Olsen JH (2002) Epidemiological investigation of local complications after cosmetic breast implant surgery in Denmark. Ann Plast Surg 48:229–237CrossRefPubMed Kjoller K, Holmich LR, Jacobsen PH, Friis S, Fryzek J, McLaughlin JK, Lipworth L, Henrikson TF, Jorgensen S, Bittmann S, Olsen JH (2002) Epidemiological investigation of local complications after cosmetic breast implant surgery in Denmark. Ann Plast Surg 48:229–237CrossRefPubMed
17.
go back to reference Wechselberger G, Del Frari B, Pulzl P, Schoeller T (2003) Inframammary fold reconstruction with a deepithelializd skin flap. Ann Plast Surg 50:433–436CrossRefPubMed Wechselberger G, Del Frari B, Pulzl P, Schoeller T (2003) Inframammary fold reconstruction with a deepithelializd skin flap. Ann Plast Surg 50:433–436CrossRefPubMed
18.
go back to reference Parsa FD (1990) Breast capsulopexy for capsular ptosis after augmentation mammoplasty. Plast Reconstr Surg 85:809–812CrossRefPubMed Parsa FD (1990) Breast capsulopexy for capsular ptosis after augmentation mammoplasty. Plast Reconstr Surg 85:809–812CrossRefPubMed
19.
go back to reference Baxter RA (2003) Intracapsular allogenic dermal grafts for breast implant-related problems. Plast Reconstr Surg 112:1692–1696CrossRefPubMed Baxter RA (2003) Intracapsular allogenic dermal grafts for breast implant-related problems. Plast Reconstr Surg 112:1692–1696CrossRefPubMed
20.
go back to reference Khan UD (2009) Selection of breast pocket using pinch test in augmentation mammoplasty: can it be relied in long term? Aesth Plast Surg 33:780–781CrossRef Khan UD (2009) Selection of breast pocket using pinch test in augmentation mammoplasty: can it be relied in long term? Aesth Plast Surg 33:780–781CrossRef
21.
go back to reference Sallbian MS, DiGregorio VR (2000) A simple technique to correct “bottoming-out” of the breast after augmentation mammoplasty. Aesthet Surg J 20:301–303CrossRef Sallbian MS, DiGregorio VR (2000) A simple technique to correct “bottoming-out” of the breast after augmentation mammoplasty. Aesthet Surg J 20:301–303CrossRef
22.
go back to reference Chasen PE, Francis CS (2008) Capsuloraphy for revisionary breast surgery. Aesthet Surg J 28:63–69CrossRef Chasen PE, Francis CS (2008) Capsuloraphy for revisionary breast surgery. Aesthet Surg J 28:63–69CrossRef
23.
go back to reference Spear SL, Carter ME, Ganz JC (2006) The correction of capsular contracture by conversion to “dual-plane” positioning: technique and outcomes. Plast Reconstr Surg 118(Suppl 7):103S–113SPubMed Spear SL, Carter ME, Ganz JC (2006) The correction of capsular contracture by conversion to “dual-plane” positioning: technique and outcomes. Plast Reconstr Surg 118(Suppl 7):103S–113SPubMed
24.
25.
go back to reference Khan UD (2009) Dynamic breasts: a common complication following partial submuscular augmentation and its correction using muscle splitting biplane technique. Aesth Plast Surg 33:353–360CrossRef Khan UD (2009) Dynamic breasts: a common complication following partial submuscular augmentation and its correction using muscle splitting biplane technique. Aesth Plast Surg 33:353–360CrossRef
26.
go back to reference Spear SL, Schwartz J, Dayan JH, Clemens MW (2009) Outcome assessment of breast distortion following submuscular breast augmentation. Aesth Plast Surg 33:44–48CrossRef Spear SL, Schwartz J, Dayan JH, Clemens MW (2009) Outcome assessment of breast distortion following submuscular breast augmentation. Aesth Plast Surg 33:44–48CrossRef
27.
go back to reference Khan UD (2009) Correction of acquired synmastia with muscle-splitting biplane implant replacement. Aesth Plast Surg 33:605–610CrossRef Khan UD (2009) Correction of acquired synmastia with muscle-splitting biplane implant replacement. Aesth Plast Surg 33:605–610CrossRef
Metadata
Title
Combining muscle-splitting biplane with multilayer capsulorrhaphy for the correction of bottoming down following subglandular augmentation
Author
Umar Daraz Khan
Publication date
01-10-2010
Publisher
Springer-Verlag
Published in
European Journal of Plastic Surgery / Issue 5/2010
Print ISSN: 0930-343X
Electronic ISSN: 1435-0130
DOI
https://doi.org/10.1007/s00238-010-0414-8

Other articles of this Issue 5/2010

European Journal of Plastic Surgery 5/2010 Go to the issue