Skip to main content
Top
Published in: Neuroradiology 6/2009

01-06-2009 | Interventional Neuroradiology

Stenting is improving and stabilizing anatomical results of coiled intracranial aneurysms

Authors: Boris Lubicz, Alexandra Bandeira, Michaël Bruneau, Aloys Dewindt, Danielle Balériaux, Olivier De Witte

Published in: Neuroradiology | Issue 6/2009

Login to get access

Abstract

Introduction

Stent-assisted coiling (SAC) is an alternative to surgical clipping for the treatment of wide-necked intracranial aneurysms (IA). However, little information is available concerning the long-term results of this treatment. The aim of this study was to report the long-term clinical and anatomical findings in 32 patients with 34 wide-necked IA treated by SAC.

Methods

A retrospective review of our prospectively maintained database identified all patients followed up for wide-necked IA treated by SAC. The clinical charts, procedural data, and angiographic results were reviewed.

Results

Thirty-two patients with 34 IA were identified including 25 asymptomatic patients, four with cranial nerve palsies, two with a subarachnoid hemorrhage, and one with transient ischemic attacks. Mean aneurysm size was 10.2 mm (range 3.5 to 26 mm). Embolization was successful in all patients and no procedure-related neurological morbidity or mortality was observed. Immediate anatomical results included nine complete occlusions (26.5%), two neck remnants (6%), and 23 incomplete occlusions (67.5%). Mean imaging follow-up of 20 months showed 18 further thrombosis (53%) and 16 stable results (47%). Finally, 27 aneurysms were completely occluded (79%), three had a neck remnant (9%), and four were incompletely occluded (12%). Asymptomatic and nonsignificant in-stent stenosis occurred in seven patients (22%).

Conclusions

SAC is safe and effective for the treatment of wide-necked IA. Despite unsatisfying immediate aneurysm occlusion, the adjunctive effect of the stent is stabilizing or significantly improving long-term anatomical results.
Literature
1.
go back to reference International Subarachnoid Aneurysm Trial (ISAT) Collaborative Group (2002) ISAT of neurosurgical clipping versus endovascular coiling in 2143 patients with ruptured intracranial aneurysms: a randomized trial. Lancet 360:1267–1274. doi:10.1016/S0140-6736(02)11314-6 CrossRef International Subarachnoid Aneurysm Trial (ISAT) Collaborative Group (2002) ISAT of neurosurgical clipping versus endovascular coiling in 2143 patients with ruptured intracranial aneurysms: a randomized trial. Lancet 360:1267–1274. doi:10.​1016/​S0140-6736(02)11314-6 CrossRef
2.
go back to reference Lubicz B, Balériaux D, Lefranc F, Brotchi J, Bruneau M, Levivier M (2007) Endovascular treatment of intracranial aneurysms as the first therapeutic option: a prospective study over 30 months in a single-centre. J Neuroradiol 34:250–259PubMed Lubicz B, Balériaux D, Lefranc F, Brotchi J, Bruneau M, Levivier M (2007) Endovascular treatment of intracranial aneurysms as the first therapeutic option: a prospective study over 30 months in a single-centre. J Neuroradiol 34:250–259PubMed
3.
go back to reference Fernandez Zubillaga A, Guglielmi G, Vinuela F, Duckwiler GR (1994) Endovascular occlusion of intracranial aneurysms with electrically detachable coils: correlation of aneurysm neck size and treatment results. AJNR Am J Neuroradiol 15:815–820PubMed Fernandez Zubillaga A, Guglielmi G, Vinuela F, Duckwiler GR (1994) Endovascular occlusion of intracranial aneurysms with electrically detachable coils: correlation of aneurysm neck size and treatment results. AJNR Am J Neuroradiol 15:815–820PubMed
4.
go back to reference Mericle RA, Wakhloo AK, Lopes DK, Lanzino G, Guterman LR, Hopkins LN (1998) Delayed aneurysm regrowth and recanalization after Guglielmi detachable coil treatment. J Neurosurg 89:142–145PubMed Mericle RA, Wakhloo AK, Lopes DK, Lanzino G, Guterman LR, Hopkins LN (1998) Delayed aneurysm regrowth and recanalization after Guglielmi detachable coil treatment. J Neurosurg 89:142–145PubMed
5.
go back to reference Cognard C, Weill A, Spelle L, Piotin M, Castaings L, Rey A, Moret J (1999) Long-term angiographic follow-up of 169 intracranial berry aneurysms occluded with detachable coils. Radiology 212:348–356PubMed Cognard C, Weill A, Spelle L, Piotin M, Castaings L, Rey A, Moret J (1999) Long-term angiographic follow-up of 169 intracranial berry aneurysms occluded with detachable coils. Radiology 212:348–356PubMed
7.
go back to reference Murayama Y, Nien YL, Duckwiller G, Gobin YP, Jahan R, Frazee J, Martin N, Vinuela F (2003) Guglielmi detachable coils embolization of cerebral aneurysms: 11 years experience. J Neurosurg 98:959–966PubMedCrossRef Murayama Y, Nien YL, Duckwiller G, Gobin YP, Jahan R, Frazee J, Martin N, Vinuela F (2003) Guglielmi detachable coils embolization of cerebral aneurysms: 11 years experience. J Neurosurg 98:959–966PubMedCrossRef
9.
go back to reference Gaba RC, Ansari SA, Roy SS, Marden FA, Viana MA, Malisch TW (2006) Embolization of intracranial aneurysms with hydrogel-coated coils versus inert platinum coils: effects on packing density, coil length and quantity, procedure performance, cost, length of hospital stay, and durability of therapy. Stroke 37:1443–1450. doi:10.1161/01.STR.0000221314.55144.0b PubMedCrossRef Gaba RC, Ansari SA, Roy SS, Marden FA, Viana MA, Malisch TW (2006) Embolization of intracranial aneurysms with hydrogel-coated coils versus inert platinum coils: effects on packing density, coil length and quantity, procedure performance, cost, length of hospital stay, and durability of therapy. Stroke 37:1443–1450. doi:10.​1161/​01.​STR.​0000221314.​55144.​0b PubMedCrossRef
10.
go back to reference Molyneux AJ, Cekirge S, Saatci I, Gal G (2004) Cerebral Aneurysm Multicenter European Onyx (CAMEO) trial: results of a prospective observational study in 20 European centers. AJNR Am J Neuroradiol 25:39–51PubMed Molyneux AJ, Cekirge S, Saatci I, Gal G (2004) Cerebral Aneurysm Multicenter European Onyx (CAMEO) trial: results of a prospective observational study in 20 European centers. AJNR Am J Neuroradiol 25:39–51PubMed
11.
go back to reference Biondi A, Janardhan V, Katz JM, Salvaggio K, Riina HA, Gobin YP (2007) Neuroform stent-assisted coil embolization of wide-neck intracranial aneurysms: strategies in stent deployment and midterm follow-up. Neurosurgery 61:460–468PubMedCrossRef Biondi A, Janardhan V, Katz JM, Salvaggio K, Riina HA, Gobin YP (2007) Neuroform stent-assisted coil embolization of wide-neck intracranial aneurysms: strategies in stent deployment and midterm follow-up. Neurosurgery 61:460–468PubMedCrossRef
12.
go back to reference Lubicz B, Leclerc X, Levivier M, Brotchi J, Pruvo JP, Lejeune JP, Balériaux D (2006) Retractable self-expandable stent for endovascular treatment of wide-necked intracranial aneurysms: preliminary experience. Neurosurgery 58:451–457PubMed Lubicz B, Leclerc X, Levivier M, Brotchi J, Pruvo JP, Lejeune JP, Balériaux D (2006) Retractable self-expandable stent for endovascular treatment of wide-necked intracranial aneurysms: preliminary experience. Neurosurgery 58:451–457PubMed
13.
go back to reference Lubicz B, François O, Levivier M, Brotchi J, Balériaux D (2008) Preliminary experience with the Enterprise stent for endovascular treatment of complex intracranial aneurysms: potential advantages and limiting characteristics. Neurosurgery 62:1063–1069PubMedCrossRef Lubicz B, François O, Levivier M, Brotchi J, Balériaux D (2008) Preliminary experience with the Enterprise stent for endovascular treatment of complex intracranial aneurysms: potential advantages and limiting characteristics. Neurosurgery 62:1063–1069PubMedCrossRef
15.
go back to reference Yavuz K, Geyik S, Pamuk AG, Koc O, Saatci I, Cekirge S (2007) Immediate and midterm follow-up results of using an electrodetachable, fully retrievable SOLO stent system in the endovascular coil occlusion of wide-necked cerebral aneurysms. J Neurosurg 107:49–55. doi:10.3171/JNS-07/07/0049 PubMedCrossRef Yavuz K, Geyik S, Pamuk AG, Koc O, Saatci I, Cekirge S (2007) Immediate and midterm follow-up results of using an electrodetachable, fully retrievable SOLO stent system in the endovascular coil occlusion of wide-necked cerebral aneurysms. J Neurosurg 107:49–55. doi:10.​3171/​JNS-07/​07/​0049 PubMedCrossRef
16.
go back to reference Hunt W, Hess R (1968) Surgical risk as related to time of intervention in the repair of intracranial aneurysms. J Neurosurg 28:14–20PubMedCrossRef Hunt W, Hess R (1968) Surgical risk as related to time of intervention in the repair of intracranial aneurysms. J Neurosurg 28:14–20PubMedCrossRef
18.
go back to reference Lubicz B, Collignon L, Lefranc F, Bruneau M, Brotchi J, Balériaux D, De Witte O (2008) Circumferential and fusiform intracranial aneurysms: reconstructive endovascular treatment with self-expandable stents. Neuroradiology 50:499–507. doi:10.1007/s00234-008-0366-x PubMedCrossRef Lubicz B, Collignon L, Lefranc F, Bruneau M, Brotchi J, Balériaux D, De Witte O (2008) Circumferential and fusiform intracranial aneurysms: reconstructive endovascular treatment with self-expandable stents. Neuroradiology 50:499–507. doi:10.​1007/​s00234-008-0366-x PubMedCrossRef
19.
go back to reference Hirabayashi M, Ohta M, Rüfenacht DA, Chopard B (2003) Characterization of flow reduction properties in an aneurysm due to a stent. Phys Rev E Stat Nonlin Soft Matter Phys 68(2 Pt 1):021918. doi:10.1103/PhysRevE.68.021918 PubMed Hirabayashi M, Ohta M, Rüfenacht DA, Chopard B (2003) Characterization of flow reduction properties in an aneurysm due to a stent. Phys Rev E Stat Nonlin Soft Matter Phys 68(2 Pt 1):021918. doi:10.​1103/​PhysRevE.​68.​021918 PubMed
21.
go back to reference Barath K, Cassot F, Fasel JH, Ohta M, Rüfenacht DA (2005) Influence of stent properties on the alteration of cerebral intra-aneurysmal haemodynamics: flow quantification in elastic sidewall aneurysm models. Neurol Res 27:S120–S128. doi:10.1179/016164105X35477 PubMedCrossRef Barath K, Cassot F, Fasel JH, Ohta M, Rüfenacht DA (2005) Influence of stent properties on the alteration of cerebral intra-aneurysmal haemodynamics: flow quantification in elastic sidewall aneurysm models. Neurol Res 27:S120–S128. doi:10.​1179/​016164105X35477 PubMedCrossRef
Metadata
Title
Stenting is improving and stabilizing anatomical results of coiled intracranial aneurysms
Authors
Boris Lubicz
Alexandra Bandeira
Michaël Bruneau
Aloys Dewindt
Danielle Balériaux
Olivier De Witte
Publication date
01-06-2009
Publisher
Springer-Verlag
Published in
Neuroradiology / Issue 6/2009
Print ISSN: 0028-3940
Electronic ISSN: 1432-1920
DOI
https://doi.org/10.1007/s00234-009-0519-6

Other articles of this Issue 6/2009

Neuroradiology 6/2009 Go to the issue