Abstract

Introduction

The purpose of the study is to describe our experience in eight cases of horizontal stenting across the circle of Willis in patients with terminal aneurysms.

Methods

Eight patients were treated with horizontal stent placement and aneurysm coiling. All aneurysms had highly unfavourable dome to neck ratios. All patients were followed up with digital subtraction angiography at 3–12 months following treatment.

Results

The Enterprise stent was successfully deployed horizontally in vessels of less than 2-mm diameter with no stent occlusion. Neurological complications occurred in one patient. Immediate and follow-up angiographic results were encouraging with six stable occlusions at 6 months. There was one asymptomatic case of in-stent stenosis and one case of late organised in-stent thrombus.

Conclusions

Horizontal deployment of the Enterprise stent to assist coil embolisation of wide-necked terminal aneurysms is feasible. This device can be navigated via relatively small communicating arteries, in cases with favourable anatomy. Early angiographic results were favourable; however, longer-term follow-up will be required.
Literature
1.
go back to reference Thorell WE, Chow MM, Woo HH et al (2005) Y-configured dual intracranial stent-assisted coil embolisation for the treatment of wide-necked basilar tip aneurysms. Neurosurgery 56(5):1035–1040PubMed Thorell WE, Chow MM, Woo HH et al (2005) Y-configured dual intracranial stent-assisted coil embolisation for the treatment of wide-necked basilar tip aneurysms. Neurosurgery 56(5):1035–1040PubMed
2.
go back to reference Cross DT, Moran CJ, Derdeyn CP et al (2005) Neuroform Stent Deployment for Treatment of a Basilar Tip Aneurysm via a Posterior Communicating Artery Route. AJNR Am J Neuroradiol 26:2578–2581PubMed Cross DT, Moran CJ, Derdeyn CP et al (2005) Neuroform Stent Deployment for Treatment of a Basilar Tip Aneurysm via a Posterior Communicating Artery Route. AJNR Am J Neuroradiol 26:2578–2581PubMed
3.
go back to reference Benndorf G, Klucznik RP, Meyer D et al (2006) ‘Cross-over’ technique for horizontal stenting of an internal carotid bifurcation aneurysm using a new self-expandable stent: technical case report. Neurosurgery 58(1 Suppl):ONS-E172PubMed Benndorf G, Klucznik RP, Meyer D et al (2006) ‘Cross-over’ technique for horizontal stenting of an internal carotid bifurcation aneurysm using a new self-expandable stent: technical case report. Neurosurgery 58(1 Suppl):ONS-E172PubMed
4.
go back to reference Kelly ME, Turner R, Gonugunta V (2007) Stent reconstruction of wide-necked aneurysms across the circle of Willis. Neurosurgery 61(5(Suppl 2)):249–254PubMedCrossRef Kelly ME, Turner R, Gonugunta V (2007) Stent reconstruction of wide-necked aneurysms across the circle of Willis. Neurosurgery 61(5(Suppl 2)):249–254PubMedCrossRef
8.
go back to reference Moret J, Ross IB, Weill A et al (2000) The retrograde approach: a consideration for the endovascular treatment of aneurysms. AJNR Am J Neuroradiol 21(2):262–268PubMed Moret J, Ross IB, Weill A et al (2000) The retrograde approach: a consideration for the endovascular treatment of aneurysms. AJNR Am J Neuroradiol 21(2):262–268PubMed
9.
go back to reference Higashida RT, Halbach VV, Dowd CF et al (2005) Initial clinical experience with a new self-expanding nitinol stent for the treatment of intracranial cerebral aneurysms: the Cordis Enterprise stent. AJNR Am J Neuroradiol 26:1751–1756PubMed Higashida RT, Halbach VV, Dowd CF et al (2005) Initial clinical experience with a new self-expanding nitinol stent for the treatment of intracranial cerebral aneurysms: the Cordis Enterprise stent. AJNR Am J Neuroradiol 26:1751–1756PubMed
Metadata
Title
Horizontal stent-assisted coil embolisation of wide-necked intracranial aneurysms with the Enterprise stent—a case series with early angiographic follow-up
Authors
Mohammed Aslam Siddiqui
Joti J. Bhattacharya
Kenneth W. Lindsay
Sarah Jenkins
Publication date
01-06-2009
Publisher
Springer-Verlag
Published in
Neuroradiology / Issue 6/2009
Print ISSN: 0028-3940
Electronic ISSN: 1432-1920
DOI
https://doi.org/10.1007/s00234-009-0517-8

Other articles of this Issue 6/2009

Neuroradiology 6/2009 Go to the issue