Skip to main content
Top
Published in: Osteoporosis International 2/2005

01-03-2005 | Review

Fixation principles in metaphyseal bone—a patent based review

Authors: R. Curtis, J. Goldhahn, R. Schwyn, P. Regazzoni, N. Suhm

Published in: Osteoporosis International | Special Issue 2/2005

Login to get access

Abstract

Osteoporotic changes start in cancellous bone due to the underlying pathophysiology. Consequently, the metaphyses are at a higher risk of “osteoporotic” fracture than the diaphysis. Furthermore, implant purchase to fix these fractures is also affected by the poor bone quality. In general, researchers and developers have worked on three different approaches to address the problem of fractures to osteoporotic bone: adapted anchoring techniques, improved load distribution as well as transfer with angular stable screws, and augmentation techniques using bone substitutes. A patent-based review was performed to evaluate which ideas were utilized to improve fixation in osteoporotic, metaphyseal bone, especially in the proximal femur, and to analyze whether the concept had entered clinical use. Anchoring devices that are either extramedullary or intramedullary have a long clinical history. However, demanding surgical techniques and complications, especially in poor quality bone, are justification that such implants and their corresponding surgical techniques need to be improved upon. Expanding elements have been evaluated in the laboratory. The results are promising and the potential of this approach has yet to be fully exploited in the clinics. Internal fixators with angular stable screws open the door for many new anchorage ideas and have great potential for further optimization of load distribution and transfer. Augmentation techniques may improve anchorage in osteoporotic bone. However, the properties of bone substitute materials will need to be modified and improved upon in order to meet the demanding requirements. If we summarise the development process and the clinical use of implants to date, we have to clearly state that more factors than simply biomechanical advantage will determine the clinical success of a new fixation principle or a new implant. Instead, fracture treatment of patients with osteoporosis really needs an interdisciplinary approach!
Literature
2.
go back to reference McCalden RW, McGeough JA, Court-Brown CM (1997) Age-related changes in the compressive strength of cancellous bone. The relative importance of changes in density and trabecular architecture. J Bone Joint Surg [Am] 79:421–427 McCalden RW, McGeough JA, Court-Brown CM (1997) Age-related changes in the compressive strength of cancellous bone. The relative importance of changes in density and trabecular architecture. J Bone Joint Surg [Am] 79:421–427
3.
go back to reference van der Linden JC, Homminga J, Verhaar JA, Weinans H. 2001) Mechanical consequences of bone loss in cancellous bone. J Bone Miner Res 16:457–465 van der Linden JC, Homminga J, Verhaar JA, Weinans H. 2001) Mechanical consequences of bone loss in cancellous bone. J Bone Miner Res 16:457–465
4.
go back to reference Dennison E, Cooper C (2000) Epidemiology of osteoporotic fractures. Horm Res 54:58–63PubMed Dennison E, Cooper C (2000) Epidemiology of osteoporotic fractures. Horm Res 54:58–63PubMed
6.
go back to reference Müller M (1964) Mechanism to repair the proximal femur joint. Swiss patent 373517 Müller M (1964) Mechanism to repair the proximal femur joint. Swiss patent 373517
7.
go back to reference Mize RD, Bucholz RW, Grogan DP (1982) Surgical treatment of displaced, comminuted fractures of the distal end of the femur. J Bone Joint Surg [Am] 64:871–879 Mize RD, Bucholz RW, Grogan DP (1982) Surgical treatment of displaced, comminuted fractures of the distal end of the femur. J Bone Joint Surg [Am] 64:871–879
8.
go back to reference Jupiter JB, Mullaji AB (1994) Blade plate fixation of proximal humeral non-unions. Injury 25:301–303CrossRefPubMed Jupiter JB, Mullaji AB (1994) Blade plate fixation of proximal humeral non-unions. Injury 25:301–303CrossRefPubMed
9.
go back to reference Kohler A, Simmen HP, Duff C, Kach K, Trentz O (1995) Osteosynthese subkapitaler Humerusfrakturen mit unkonventionell applizierten Implantaten. Swiss Surg:114–117 Kohler A, Simmen HP, Duff C, Kach K, Trentz O (1995) Osteosynthese subkapitaler Humerusfrakturen mit unkonventionell applizierten Implantaten. Swiss Surg:114–117
10.
go back to reference Rehman S, Damron TA, Geel C (2000) Humeral blade plate fixation of intercalary allografts and segmentally comminuted proximal humeral fractures: a preliminary report. Injury 31:783–788CrossRefPubMed Rehman S, Damron TA, Geel C (2000) Humeral blade plate fixation of intercalary allografts and segmentally comminuted proximal humeral fractures: a preliminary report. Injury 31:783–788CrossRefPubMed
11.
go back to reference Ring D, McKee MD, Perey BH, Jupiter JB (2001) The use of a blade plate and autogenous cancellous bone graft in the treatment of ununited fractures of the proximal humerus. J Shoulder Elbow Surg 10:501–507CrossRefPubMed Ring D, McKee MD, Perey BH, Jupiter JB (2001) The use of a blade plate and autogenous cancellous bone graft in the treatment of ununited fractures of the proximal humerus. J Shoulder Elbow Surg 10:501–507CrossRefPubMed
12.
go back to reference An YH (2002) Internal fixation in osteoporotic bone. Thieme Verlag, New York An YH (2002) Internal fixation in osteoporotic bone. Thieme Verlag, New York
13.
go back to reference Instrum K, Fennell C, Shrive N, Damson E, Sonnabend D, Hollinshead R (1998) Semitubular blade plate fixation in proximal humeral fractures: a biomechanical study in a cadaveric model. J Shoulder Elbow Surg 7:462–466CrossRefPubMed Instrum K, Fennell C, Shrive N, Damson E, Sonnabend D, Hollinshead R (1998) Semitubular blade plate fixation in proximal humeral fractures: a biomechanical study in a cadaveric model. J Shoulder Elbow Surg 7:462–466CrossRefPubMed
14.
go back to reference Koval KJ, Hoehl JJ, Kummer FJ, Simon JA (1997) Distal femoral fixation: a biomechanical comparison of the standard condylar buttress plate, a locked buttress plate, and the 95-degree blade plate. J Orthop Trauma 11:521–524CrossRefPubMed Koval KJ, Hoehl JJ, Kummer FJ, Simon JA (1997) Distal femoral fixation: a biomechanical comparison of the standard condylar buttress plate, a locked buttress plate, and the 95-degree blade plate. J Orthop Trauma 11:521–524CrossRefPubMed
15.
go back to reference Nungu KS, Olerud C, Rehnberg L (1993) Treatment of subtrochanteric fractures with the AO dynamic condylar screw. Injury 24:90–92CrossRefPubMed Nungu KS, Olerud C, Rehnberg L (1993) Treatment of subtrochanteric fractures with the AO dynamic condylar screw. Injury 24:90–92CrossRefPubMed
16.
go back to reference Sanders R, Regazzoni P, Ruedi TP (1989) Treatment of supracondylar-intracondylar fractures of the femur using the dynamic condylar screw. J Orthop Trauma 3:214–222PubMed Sanders R, Regazzoni P, Ruedi TP (1989) Treatment of supracondylar-intracondylar fractures of the femur using the dynamic condylar screw. J Orthop Trauma 3:214–222PubMed
17.
go back to reference Osterwalder A, Dietschi C, Martinoli S (1985) Erste Erfahrungen mit der dynamischen Huftschraube (DHS) der AO. Z Orthop Ihre Grenzgeb 123:193–200PubMed Osterwalder A, Dietschi C, Martinoli S (1985) Erste Erfahrungen mit der dynamischen Huftschraube (DHS) der AO. Z Orthop Ihre Grenzgeb 123:193–200PubMed
18.
go back to reference Poigenfurst J, Hertz H, Hofer S (1983) Erste Erfahrungen mit der dynamischen Huftschraube im Vergleich zu anderen Osteosyntheseverfahren. Unfallchirurgie 9:98–103PubMed Poigenfurst J, Hertz H, Hofer S (1983) Erste Erfahrungen mit der dynamischen Huftschraube im Vergleich zu anderen Osteosyntheseverfahren. Unfallchirurgie 9:98–103PubMed
19.
go back to reference Schatzker J, Mahomed N, Schiffman K, Kellam J (1989) Dynamic condylar screw: a new device. A preliminary report. J Orthop Trauma 3:124–132PubMed Schatzker J, Mahomed N, Schiffman K, Kellam J (1989) Dynamic condylar screw: a new device. A preliminary report. J Orthop Trauma 3:124–132PubMed
20.
go back to reference Bolhofner BR, Russo PR, Carmen B (1999) Results of intertrochanteric femur fractures treated with a 135-degree sliding screw with a two-hole side plate. J Orthop Trauma 13:5–8CrossRefPubMed Bolhofner BR, Russo PR, Carmen B (1999) Results of intertrochanteric femur fractures treated with a 135-degree sliding screw with a two-hole side plate. J Orthop Trauma 13:5–8CrossRefPubMed
21.
go back to reference Haynes RC, Poll RG, Miles AW, Weston RB (1997) Failure of femoral head fixation: a cadaveric analysis of lag screw cut-out with the gamma locking nail and AO dynamic hip screw. Injury 28:337–341CrossRefPubMed Haynes RC, Poll RG, Miles AW, Weston RB (1997) Failure of femoral head fixation: a cadaveric analysis of lag screw cut-out with the gamma locking nail and AO dynamic hip screw. Injury 28:337–341CrossRefPubMed
22.
go back to reference Barrios C, Brostrom LA, Stark A, Walheim G (1993) Healing complications after internal fixation of trochanteric hip fractures: the prognostic value of osteoporosis. J Orthop Trauma 7:438–442PubMed Barrios C, Brostrom LA, Stark A, Walheim G (1993) Healing complications after internal fixation of trochanteric hip fractures: the prognostic value of osteoporosis. J Orthop Trauma 7:438–442PubMed
23.
go back to reference Baumgaertner MR, Solberg BD (1997) Awareness of tip-apex distance reduces failure of fixation of trochanteric fractures of the hip. J Bone Joint Surg [Br] 79:969–971 Baumgaertner MR, Solberg BD (1997) Awareness of tip-apex distance reduces failure of fixation of trochanteric fractures of the hip. J Bone Joint Surg [Br] 79:969–971
24.
go back to reference Frigg R (1991) Osteosynthesis anchoring screw. Disclosure Document, DE 4106876 A1 Frigg R (1991) Osteosynthesis anchoring screw. Disclosure Document, DE 4106876 A1
25.
go back to reference Frigg R, Schwyn R (1998) Device for attaching fractured hip joint heads. World patent WO 98/05263 Frigg R, Schwyn R (1998) Device for attaching fractured hip joint heads. World patent WO 98/05263
26.
go back to reference Babst R, Renner N, Biedermann M, Rosso R, Heberer M, Harder F, Regazzoni P (1998) Clinical results using the trochanter stabilizing plate (TSP): the modular extension of the dynamic hip screw (DHS) for internal fixation of selected unstable intertrochanteric fractures. J Orthop Trauma 12:392–399CrossRefPubMed Babst R, Renner N, Biedermann M, Rosso R, Heberer M, Harder F, Regazzoni P (1998) Clinical results using the trochanter stabilizing plate (TSP): the modular extension of the dynamic hip screw (DHS) for internal fixation of selected unstable intertrochanteric fractures. J Orthop Trauma 12:392–399CrossRefPubMed
27.
go back to reference Ito K, Hungerbuhler R, Wahl D, Grass R (2001) Improved intramedullary nail interlocking in osteoporotic bone. J Orthop Trauma 15:192–196CrossRefPubMed Ito K, Hungerbuhler R, Wahl D, Grass R (2001) Improved intramedullary nail interlocking in osteoporotic bone. J Orthop Trauma 15:192–196CrossRefPubMed
28.
go back to reference Zickel RE, inventor (1969) Intramedullary rod and cross nail assembly for treating femur fractures. USA patent 3’433’220 Zickel RE, inventor (1969) Intramedullary rod and cross nail assembly for treating femur fractures. USA patent 3’433’220
29.
go back to reference Grosse A, Harder HE, inventors (1990) Osteosynthesis aid to supply subtrochanteric fractures. European patent 0257118 Grosse A, Harder HE, inventors (1990) Osteosynthesis aid to supply subtrochanteric fractures. European patent 0257118
30.
go back to reference Zifko B, Poigenfurst J, Pezzei C, Stockley I (1991) Flexible intramedullary pins in the treatment of unstable proximal humeral fractures. Injury 22:60–62CrossRefPubMed Zifko B, Poigenfurst J, Pezzei C, Stockley I (1991) Flexible intramedullary pins in the treatment of unstable proximal humeral fractures. Injury 22:60–62CrossRefPubMed
31.
go back to reference Manson C (1962) Fixation device for fractured femur. USA patent 3’025’853 Manson C (1962) Fixation device for fractured femur. USA patent 3’025’853
32.
go back to reference Frigg R (1991) Osteosynthetic assembly with twist fixation plate. European patent 0411273 A1 Frigg R (1991) Osteosynthetic assembly with twist fixation plate. European patent 0411273 A1
33.
go back to reference Frigg (1996) Device for holding broken bones in fixed position. European patent EP 0491138 B1 Frigg (1996) Device for holding broken bones in fixed position. European patent EP 0491138 B1
34.
go back to reference Ito K, Hungerbuhler R, Wahl D, Grass R (2001) Improved intramedullary nail interlocking in osteoporotic bone. J Orthop Trauma 15:192–196CrossRefPubMed Ito K, Hungerbuhler R, Wahl D, Grass R (2001) Improved intramedullary nail interlocking in osteoporotic bone. J Orthop Trauma 15:192–196CrossRefPubMed
35.
go back to reference Broos PL, Reynders P (2002) The use of the unreamed AO femoral intramedullary nail with spiral blade in nonpathologic fractures of the femur: experiences with eighty consecutive cases. J Orthop Trauma 16:150–154CrossRefPubMed Broos PL, Reynders P (2002) The use of the unreamed AO femoral intramedullary nail with spiral blade in nonpathologic fractures of the femur: experiences with eighty consecutive cases. J Orthop Trauma 16:150–154CrossRefPubMed
36.
go back to reference Qureshi F, Gliatis J, Hahn DM (1999) Early failure of spiral blade using with an unreamed femoral nail: a case report. Injury 30:219–220CrossRefPubMed Qureshi F, Gliatis J, Hahn DM (1999) Early failure of spiral blade using with an unreamed femoral nail: a case report. Injury 30:219–220CrossRefPubMed
37.
go back to reference Sochart DH, Bamford DJ, Paul AS (1998) Failure of the spiral blade module of the AO unreamed femoral nail. Arch Orthop Trauma Surg 117:415–417CrossRefPubMed Sochart DH, Bamford DJ, Paul AS (1998) Failure of the spiral blade module of the AO unreamed femoral nail. Arch Orthop Trauma Surg 117:415–417CrossRefPubMed
38.
go back to reference Syed AA, Kennedy JG, Mullet H, O’Flanagan J, Taylor D. (2000) Fatigue failure of an AO spiral blade. Arch Orthop Trauma Surg 120:366–368CrossRefPubMed Syed AA, Kennedy JG, Mullet H, O’Flanagan J, Taylor D. (2000) Fatigue failure of an AO spiral blade. Arch Orthop Trauma Surg 120:366–368CrossRefPubMed
39.
go back to reference Friedl W (1993) Relevance of osteotomy and implant characteristics in inter- and subtrochanteric osteotomies. Experimental examination under alternating and static load after stabilisation with different devices including gamma nail osteosynthesis. Arch Orthop Trauma Surg 113:5–11PubMed Friedl W (1993) Relevance of osteotomy and implant characteristics in inter- and subtrochanteric osteotomies. Experimental examination under alternating and static load after stabilisation with different devices including gamma nail osteosynthesis. Arch Orthop Trauma Surg 113:5–11PubMed
40.
go back to reference Friedl W, Anthoni C, Fritz T, Schmotzer H, Wipf M (1998) Die Bedeutung der Klingengeometrie fur die Verankerungsstabilitat bei kurzem Verriegelungsnagelsystem des proximalen Femurendes (Gleitnagel). Langenbecks Arch Chir Suppl Kongressbd 115:1224–1226PubMed Friedl W, Anthoni C, Fritz T, Schmotzer H, Wipf M (1998) Die Bedeutung der Klingengeometrie fur die Verankerungsstabilitat bei kurzem Verriegelungsnagelsystem des proximalen Femurendes (Gleitnagel). Langenbecks Arch Chir Suppl Kongressbd 115:1224–1226PubMed
41.
go back to reference Schwammle K, Kelsch G, Ulrich C (1996) Stellenwert einer belastungsstabilen Osteosynthese pertrochanterer Frakturen in der Gerontotraumatologie. Langenbecks Arch Chir Suppl Kongressbd 113:967–969PubMed Schwammle K, Kelsch G, Ulrich C (1996) Stellenwert einer belastungsstabilen Osteosynthese pertrochanterer Frakturen in der Gerontotraumatologie. Langenbecks Arch Chir Suppl Kongressbd 113:967–969PubMed
42.
go back to reference Drew T, Allcock P (2002) A new method of fixation in osteoporotic bone. A preliminary report. Injury 33:685–689CrossRefPubMed Drew T, Allcock P (2002) A new method of fixation in osteoporotic bone. A preliminary report. Injury 33:685–689CrossRefPubMed
43.
go back to reference Steiger P, Frigg R, Eschbach L (2003) Device for fixing surgical implants. US patent 2003/0199877 Steiger P, Frigg R, Eschbach L (2003) Device for fixing surgical implants. US patent 2003/0199877
44.
go back to reference Zeiter S, Montavon P, Schneider E, Ito K (2004) Plate stabilization with bone rivets: an alternative method for internal fixation of fractures. J Orthop Trauma 18:279–285CrossRefPubMed Zeiter S, Montavon P, Schneider E, Ito K (2004) Plate stabilization with bone rivets: an alternative method for internal fixation of fractures. J Orthop Trauma 18:279–285CrossRefPubMed
45.
go back to reference Frei R, Hehli M (2001) Osteosynthetic anchoring element. World patent WO 01/76493 A1 Frei R, Hehli M (2001) Osteosynthetic anchoring element. World patent WO 01/76493 A1
46.
go back to reference Mennen U (1982) Internal fixation device for bone fractures. USA patent 4364382 Mennen U (1982) Internal fixation device for bone fractures. USA patent 4364382
47.
go back to reference Ahuja S, Chatterji S (2002) The Mennen femoral plate for fixation of periprosthetic femoral fractures following hip arthroplasty. Injury 33:47–50CrossRefPubMed Ahuja S, Chatterji S (2002) The Mennen femoral plate for fixation of periprosthetic femoral fractures following hip arthroplasty. Injury 33:47–50CrossRefPubMed
48.
go back to reference Kamineni S, Ware HE (1999) The Mennen plate: unsuitable for elderly femoral peri-prosthetic fractures. Injury 30:257–60CrossRefPubMed Kamineni S, Ware HE (1999) The Mennen plate: unsuitable for elderly femoral peri-prosthetic fractures. Injury 30:257–60CrossRefPubMed
49.
go back to reference Noorda RJ, Wuisman PI (2002) Mennen plate fixation for the treatment of periprosthetic femoral fractures: a multicenter study of thirty-six fractures. J Bone Joint Surg [Am] 84-A:2211–2215 Noorda RJ, Wuisman PI (2002) Mennen plate fixation for the treatment of periprosthetic femoral fractures: a multicenter study of thirty-six fractures. J Bone Joint Surg [Am] 84-A:2211–2215
50.
go back to reference Otremski I, Nusam I, Glickman M, Newman RJ (1998) Mennen paraskeletal plate fixation for fracture of the femoral shaft in association with ipsilateral hip arthroplasty. Injury 29:421–423CrossRefPubMed Otremski I, Nusam I, Glickman M, Newman RJ (1998) Mennen paraskeletal plate fixation for fracture of the femoral shaft in association with ipsilateral hip arthroplasty. Injury 29:421–423CrossRefPubMed
51.
go back to reference Petersen VS (1998) Problems with the Mennen plate when used for femoral fractures associated with implants. A report of 5 patients. Int Orthop 22:169–170CrossRefPubMed Petersen VS (1998) Problems with the Mennen plate when used for femoral fractures associated with implants. A report of 5 patients. Int Orthop 22:169–170CrossRefPubMed
52.
go back to reference Uchio Y, Shu N, Nishikawa U, Takata K, Ochi M (1997) Mennen plate fixation for fractures of the femoral shaft after ipsilateral hip arthroplasty. J Trauma 42:1157–1160PubMed Uchio Y, Shu N, Nishikawa U, Takata K, Ochi M (1997) Mennen plate fixation for fractures of the femoral shaft after ipsilateral hip arthroplasty. J Trauma 42:1157–1160PubMed
53.
go back to reference Perren SM (2002) Evolution of the internal fixation of long bone fractures. The scientific basis of biological internal fixation: choosing a new balance between stability and biology. J Bone Joint Surg [Br] 84:1093–1110 Perren SM (2002) Evolution of the internal fixation of long bone fractures. The scientific basis of biological internal fixation: choosing a new balance between stability and biology. J Bone Joint Surg [Br] 84:1093–1110
54.
go back to reference Mast G (1993) Screw nut for plate osteosynthesis. USA patent 5’269’784 Mast G (1993) Screw nut for plate osteosynthesis. USA patent 5’269’784
55.
go back to reference Kolodziej P, Lee FS, Patel A, Kassab SS, Shen KL, Yang KH, Mast JW (1998) Biomechanical evaluation of the Schuhli nut. Clin Orthop 347:79–85CrossRefPubMed Kolodziej P, Lee FS, Patel A, Kassab SS, Shen KL, Yang KH, Mast JW (1998) Biomechanical evaluation of the Schuhli nut. Clin Orthop 347:79–85CrossRefPubMed
56.
go back to reference Tepic S, Perren SM, Sutter F, Straumann F, inventors (1994) Bone plate with conical holes. European patent 0355035 B1 Tepic S, Perren SM, Sutter F, Straumann F, inventors (1994) Bone plate with conical holes. European patent 0355035 B1
57.
go back to reference Frigg R, Schavan R, Hehli M (2001) Bone plate. European patent EP 0848600 B1 Frigg R, Schavan R, Hehli M (2001) Bone plate. European patent EP 0848600 B1
58.
go back to reference Farouk O, Krettek C, Miclau T, Schandelmaier P, Guy P, Tscherne H (1997) Minimally invasive plate osteosynthesis and vascularity: preliminary results of a cadaver injection study. Injury 28:A7–12CrossRefPubMed Farouk O, Krettek C, Miclau T, Schandelmaier P, Guy P, Tscherne H (1997) Minimally invasive plate osteosynthesis and vascularity: preliminary results of a cadaver injection study. Injury 28:A7–12CrossRefPubMed
59.
go back to reference Farouk O, Krettek C, Miclau T, Schandelmaier P, Tscherne H (1998) Effects of percutaneous and conventional plating techniques on the blood supply to the femur. Arch Orthop Trauma Surg 117:438–441CrossRefPubMed Farouk O, Krettek C, Miclau T, Schandelmaier P, Tscherne H (1998) Effects of percutaneous and conventional plating techniques on the blood supply to the femur. Arch Orthop Trauma Surg 117:438–441CrossRefPubMed
60.
go back to reference Anonymous (1999) Prospective clinical trial of the less invasive stabilization system for supracondylar femur fractures Anonymous (1999) Prospective clinical trial of the less invasive stabilization system for supracondylar femur fractures
61.
go back to reference Schandelmaier P, Krettek C, Miclau T, Stephan C (1999) Stabilization of distal femoral fractures using the LISS. Tech Orthop:230–246 Schandelmaier P, Krettek C, Miclau T, Stephan C (1999) Stabilization of distal femoral fractures using the LISS. Tech Orthop:230–246
62.
go back to reference Wagner M, Frigg R, Schavan R (2000) Bone plate. World patent WO 00/53110 Wagner M, Frigg R, Schavan R (2000) Bone plate. World patent WO 00/53110
63.
go back to reference Wolter D (1999) Fixation system for bone. German patent DE 43117 C2 Wolter D (1999) Fixation system for bone. German patent DE 43117 C2
64.
go back to reference Wolter D, Schümann U, Seide K (1999) Universaller Titanfixateur interne—Entwicklungsgeschichte, Prinzip, Mechanik, Implantatgestaltung und operativer Einsatz. Trauma Berufskrankh 1:307–319CrossRef Wolter D, Schümann U, Seide K (1999) Universaller Titanfixateur interne—Entwicklungsgeschichte, Prinzip, Mechanik, Implantatgestaltung und operativer Einsatz. Trauma Berufskrankh 1:307–319CrossRef
65.
go back to reference Mainil-Varlet P, Cordey J, Landolt M, Gogolewski S (1997) The use of a resorbable augmentation device to secure plating of osteoporotic bones. An in vitro study. Int Orthop 21:217–222CrossRefPubMed Mainil-Varlet P, Cordey J, Landolt M, Gogolewski S (1997) The use of a resorbable augmentation device to secure plating of osteoporotic bones. An in vitro study. Int Orthop 21:217–222CrossRefPubMed
66.
go back to reference Constantz BR, Ison IC, Fulmer MT, Poser RD, Smith ST, VanWagoner M, Ross J, Goldstein SA, Jupiter JB, Rosenthal DI (1995) Skeletal repair by in situ formation of the mineral phase of bone. Science 267:1796–1799PubMed Constantz BR, Ison IC, Fulmer MT, Poser RD, Smith ST, VanWagoner M, Ross J, Goldstein SA, Jupiter JB, Rosenthal DI (1995) Skeletal repair by in situ formation of the mineral phase of bone. Science 267:1796–1799PubMed
68.
go back to reference Rehnberg L, Olerud C (1989) Fixation of femoral neck fractures. Comparison of the Uppsala and von Bahr screws. Acta Orthop Scand 60:579–584PubMed Rehnberg L, Olerud C (1989) Fixation of femoral neck fractures. Comparison of the Uppsala and von Bahr screws. Acta Orthop Scand 60:579–584PubMed
69.
go back to reference Stromqvist B, Hansson LI, Nilsson LT, Thorngren KG (1987) Prognostic precision in postoperative99mTc-MDP scintimetry after femoral neck fracture. Acta Orthop Scand 58:494–498PubMed Stromqvist B, Hansson LI, Nilsson LT, Thorngren KG (1987) Prognostic precision in postoperative99mTc-MDP scintimetry after femoral neck fracture. Acta Orthop Scand 58:494–498PubMed
70.
go back to reference Margulies JY, Baroud G, Steffen T, Aebi M (2003) Method and apparatus for augmentation of the femoral neck. USA patent US 2003/0045885 A1 Margulies JY, Baroud G, Steffen T, Aebi M (2003) Method and apparatus for augmentation of the femoral neck. USA patent US 2003/0045885 A1
71.
go back to reference Augat P, Rapp S, Claes L (2002) A modified hip screw incorporating injected cement for the fixation of osteoporotic trochanteric fractures. J Orthop Trauma 16:311–316CrossRefPubMed Augat P, Rapp S, Claes L (2002) A modified hip screw incorporating injected cement for the fixation of osteoporotic trochanteric fractures. J Orthop Trauma 16:311–316CrossRefPubMed
72.
go back to reference Tronzo R (1987) Fenestrated hip screw and method of augmented fixation. USA patent US 4’653’489 Tronzo R (1987) Fenestrated hip screw and method of augmented fixation. USA patent US 4’653’489
73.
go back to reference Reynders P, Berger R (2001) Bone screw. World patent WO 01/17447 Reynders P, Berger R (2001) Bone screw. World patent WO 01/17447
74.
go back to reference Draenert K (1995) Suction drainage bone screw. European patent 0305417 B1 Draenert K (1995) Suction drainage bone screw. European patent 0305417 B1
Metadata
Title
Fixation principles in metaphyseal bone—a patent based review
Authors
R. Curtis
J. Goldhahn
R. Schwyn
P. Regazzoni
N. Suhm
Publication date
01-03-2005
Publisher
Springer-Verlag
Published in
Osteoporosis International / Issue Special Issue 2/2005
Print ISSN: 0937-941X
Electronic ISSN: 1433-2965
DOI
https://doi.org/10.1007/s00198-004-1763-6

Other articles of this Special Issue 2/2005

Osteoporosis International 2/2005 Go to the issue