Abstract

Introduction and hypothesis

Polypropylene meshes are frequently used in abdominal and vaginal reconstructive surgery. Recently, several authors have claimed that mesh-associated complications may be linked to mesh shrinkage. We have performed a prospective study with postoperative follow-up by ultrasound examination at two time points after Prolift anterior implantation to assess changes in the ultrasound appearance of mesh implants over time.

Methods

We assessed 36 patients who had undergone mesh implantation with Prolift anterior mesh for the correction of symptomatic anterior vaginal wall prolapse. During the surgery, we measured the actual midline length of the mesh (initial length). On the fourth postoperative day, we performed a vaginal ultrasound examination (US) to measure mesh length in the midsagittal plane. A second US was performed 3–5 months after surgery to repeat this measurement.

Results

There was a significant difference in mesh length determined before and 4 days after surgery (90.3 vs. 57.1 mm, P = <0.0001) indicating intraoperative folding. On comparing early and late postoperative ultrasound measurements, there was a reduction in length from 57.1 to 48.3 mm (P < 0.0001), indicating possible shrinkage or retraction.

Conclusions

Intraoperative folding seems to be responsible for a large part of the difference between preoperative (in vitro) and postoperative (US) measurements of mesh dimensions, suggesting that surgical techniques may require adjustment.
Literature
1.
go back to reference Maher C, Baessler K, Glazener CM, Adams EJ, Hagen S (2008) Surgical management of pelvic organ prolapse in women: a short version Cochrane review. Neurourol Urodyn 27:3–12PubMedCrossRef Maher C, Baessler K, Glazener CM, Adams EJ, Hagen S (2008) Surgical management of pelvic organ prolapse in women: a short version Cochrane review. Neurourol Urodyn 27:3–12PubMedCrossRef
2.
go back to reference Feiner B, Maher C (2010) Vaginal mesh contraction: definition, clinical presentation, and management. Obstet Gynecol 115:325–330PubMedCrossRef Feiner B, Maher C (2010) Vaginal mesh contraction: definition, clinical presentation, and management. Obstet Gynecol 115:325–330PubMedCrossRef
3.
go back to reference Letouzey V, De Tayrac R, Deffieux X, Fernandez H (2008) Long-term anatomical and functional results after trans-vaginal cystocele repair using a tension-free polypropylene mesh. Int Urogynecol J Pelvic Floor Dysfunct 19:S82–S83 Letouzey V, De Tayrac R, Deffieux X, Fernandez H (2008) Long-term anatomical and functional results after trans-vaginal cystocele repair using a tension-free polypropylene mesh. Int Urogynecol J Pelvic Floor Dysfunct 19:S82–S83
4.
go back to reference Velemir L, Amblard J, Fatton B, Savary D, Jacquetin B (2010) Transvaginal mesh repair of anterior and posterior vaginal wall prolapse: a clinical and ultrasonographic study. Ultrasound Obstet Gynecol 35(4):474–480PubMedCrossRef Velemir L, Amblard J, Fatton B, Savary D, Jacquetin B (2010) Transvaginal mesh repair of anterior and posterior vaginal wall prolapse: a clinical and ultrasonographic study. Ultrasound Obstet Gynecol 35(4):474–480PubMedCrossRef
5.
go back to reference Sergent F, Desilles N, Lacoume Y, Bunel C, Marie JP, Marpeau L (2009) Experimental biomechanical evaluation of polypropylene prostheses used in pelvic organ prolapse surgery. Int Urogynecol J Pelvic Floor Dysfunct 20:597–604CrossRef Sergent F, Desilles N, Lacoume Y, Bunel C, Marie JP, Marpeau L (2009) Experimental biomechanical evaluation of polypropylene prostheses used in pelvic organ prolapse surgery. Int Urogynecol J Pelvic Floor Dysfunct 20:597–604CrossRef
6.
go back to reference Mamy L, Letouzey J, Lavigne J, Garric X, Mares P, De Tayrac R (2009) Correlation between contraction and infection of implanted synthetic meshes, using an animal model of mesh infection. Int Urogynecol J Pelvic Floor Dysfunct 20:S167 Mamy L, Letouzey J, Lavigne J, Garric X, Mares P, De Tayrac R (2009) Correlation between contraction and infection of implanted synthetic meshes, using an animal model of mesh infection. Int Urogynecol J Pelvic Floor Dysfunct 20:S167
7.
go back to reference Cobb WS, Burns JM, Peindl RD, Carbonell AM, Matthews BD, Kercher KW, Heniford BT (2006) Textile analysis of heavy weight, mid-weight, and light weight polypropylene mesh in a porcine ventral hernia model. J Surg Res 136:1–7PubMedCrossRef Cobb WS, Burns JM, Peindl RD, Carbonell AM, Matthews BD, Kercher KW, Heniford BT (2006) Textile analysis of heavy weight, mid-weight, and light weight polypropylene mesh in a porcine ventral hernia model. J Surg Res 136:1–7PubMedCrossRef
8.
go back to reference Klinge U, Klosterhalfen B, Birkenhauer V, Junge K, Conze J, Schumpelick V (2002) Impact of polymer pore size on the interface scar formation in a rat model. J Surg Res 103:208–214PubMedCrossRef Klinge U, Klosterhalfen B, Birkenhauer V, Junge K, Conze J, Schumpelick V (2002) Impact of polymer pore size on the interface scar formation in a rat model. J Surg Res 103:208–214PubMedCrossRef
9.
go back to reference Konstantinovic ML, Pille E, Malinowska M, Verbeken E, De Ridder D, Deprest J (2007) Tensile strength and host response towards different polypropylene implant materials used for augmentation of fascial repair in a rat model. Int Urogynecol J Pelvic Floor Dysfunct 18:619–626PubMedCrossRef Konstantinovic ML, Pille E, Malinowska M, Verbeken E, De Ridder D, Deprest J (2007) Tensile strength and host response towards different polypropylene implant materials used for augmentation of fascial repair in a rat model. Int Urogynecol J Pelvic Floor Dysfunct 18:619–626PubMedCrossRef
10.
go back to reference Tunn R, Picot A, Marschke J, Gauruder-Burmester A (2007) Sonomorphological evaluation of polypropylene mesh implants after vaginal mesh repair in women with cystocele or rectocele. Ultrasound Obstet Gynecol 29:449–452PubMedCrossRef Tunn R, Picot A, Marschke J, Gauruder-Burmester A (2007) Sonomorphological evaluation of polypropylene mesh implants after vaginal mesh repair in women with cystocele or rectocele. Ultrasound Obstet Gynecol 29:449–452PubMedCrossRef
11.
go back to reference Dietz HP, Barry C, Lim YN, Rane A (2005) Two-dimensional and three-dimensional ultrasound imaging of suburethral slings. Ultrasound Obstet Gynecol 26:175–179PubMedCrossRef Dietz HP, Barry C, Lim YN, Rane A (2005) Two-dimensional and three-dimensional ultrasound imaging of suburethral slings. Ultrasound Obstet Gynecol 26:175–179PubMedCrossRef
12.
go back to reference Masata J, Martan A, Svabik K, Drahoradova P, Pavlikova M, Hlasenska J (2005) Changes in urethra mobility after TVT operation. Ceska Gynekol 70:220–225PubMed Masata J, Martan A, Svabik K, Drahoradova P, Pavlikova M, Hlasenska J (2005) Changes in urethra mobility after TVT operation. Ceska Gynekol 70:220–225PubMed
13.
go back to reference Debodinance P, Berrocal J, Clave H, Cosson M, Garbin O, Jacquetin B, Rosenthal C, Salet-Lizee D, Villet R (2004) Changing attitudes on the surgical treatment of urogenital prolapse: birth of the tension-free vaginal mesh. J Gynecol Obstet Biol Reprod (Paris) 33:577–588 Debodinance P, Berrocal J, Clave H, Cosson M, Garbin O, Jacquetin B, Rosenthal C, Salet-Lizee D, Villet R (2004) Changing attitudes on the surgical treatment of urogenital prolapse: birth of the tension-free vaginal mesh. J Gynecol Obstet Biol Reprod (Paris) 33:577–588
14.
go back to reference Svabik K, Martan A, Masata J, El Haddad J (2009) Vaginal mesh shrinking—ultrasound assessment and quantification. Int Urogynecol J Pelvic Floor Dysfunct 20:S166 Svabik K, Martan A, Masata J, El Haddad J (2009) Vaginal mesh shrinking—ultrasound assessment and quantification. Int Urogynecol J Pelvic Floor Dysfunct 20:S166
15.
go back to reference Fischer T, Ladurner R, Gangkofer A, Mussack T, Reiser M, Lienemann A (2007) Functional cine MRI of the abdomen for the assessment of implanted synthetic mesh in patients after incisional hernia repair: initial results. European Radiology 17:3123–3129PubMedCrossRef Fischer T, Ladurner R, Gangkofer A, Mussack T, Reiser M, Lienemann A (2007) Functional cine MRI of the abdomen for the assessment of implanted synthetic mesh in patients after incisional hernia repair: initial results. European Radiology 17:3123–3129PubMedCrossRef
16.
go back to reference Boukerrou M, Boulanger L, Rubod C, Lambaudie E, Dubois P, Cosson M (2007) Study of the biomechanical properties of synthetic mesh implanted in vivo. Eur J Obstet Gynecol Reprod Biol 134:262–267PubMedCrossRef Boukerrou M, Boulanger L, Rubod C, Lambaudie E, Dubois P, Cosson M (2007) Study of the biomechanical properties of synthetic mesh implanted in vivo. Eur J Obstet Gynecol Reprod Biol 134:262–267PubMedCrossRef
Metadata
Title
Ultrasound appearances after mesh implantation—evidence of mesh contraction or folding?
Authors
Kamil Svabík
Alois Martan
Jaromir Masata
Rachid El-Haddad
Petr Hubka
Marketa Pavlikova
Publication date
01-05-2011
Publisher
Springer-Verlag
Published in
International Urogynecology Journal / Issue 5/2011
Print ISSN: 0937-3462
Electronic ISSN: 1433-3023
DOI
https://doi.org/10.1007/s00192-010-1308-9

Other articles of this Issue 5/2011

International Urogynecology Journal 5/2011 Go to the issue