Skip to main content
Top
Published in: Knee Surgery, Sports Traumatology, Arthroscopy 5/2018

01-05-2018 | Knee

Case-related factors affecting cutting errors of the proximal tibia in total knee arthroplasty assessed by computer navigation

Authors: Tadashi Tsukeoka, Yoshikazu Tsuneizumi, Kensuke Yoshino, Mashiko Suzuki

Published in: Knee Surgery, Sports Traumatology, Arthroscopy | Issue 5/2018

Login to get access

Abstract

Purpose

The aim of this study was to determine factors that contribute to bone cutting errors of conventional instrumentation for tibial resection in total knee arthroplasty (TKA) as assessed by an image-free navigation system. The hypothesis is that preoperative varus alignment is a significant contributory factor to tibial bone cutting errors.

Methods

This was a prospective study of a consecutive series of 72 TKAs. The amount of the tibial first-cut errors with reference to the planned cutting plane in both coronal and sagittal planes was measured by an image-free computer navigation system. Multiple regression models were developed with the amount of tibial cutting error in the coronal and sagittal planes as dependent variables and sex, age, disease, height, body mass index, preoperative alignment, patellar height (Insall-Salvati ratio) and preoperative flexion angle as independent variables.

Results

Multiple regression analysis showed that sex (male gender) (R = 0.25 p = 0.047) and preoperative varus alignment (R = 0.42, p = 0.001) were positively associated with varus tibial cutting errors in the coronal plane. In the sagittal plane, none of the independent variables was significant.

Conclusion

When performing TKA in varus deformity, careful confirmation of the bone cutting surface should be performed to avoid varus alignment. The results of this study suggest technical considerations that can help a surgeon achieve more accurate component placement.

Level of evidence

IV.
Literature
1.
go back to reference Bae DK, Song SJ, Heo DB et al (2013) Does the severity of preoperative varus deformity influence postoperative alignment in both conventional and computer-assisted total knee arthroplasty? Knee Surg Sports Traumatol Arthrosc 21(10):2248–2254CrossRefPubMed Bae DK, Song SJ, Heo DB et al (2013) Does the severity of preoperative varus deformity influence postoperative alignment in both conventional and computer-assisted total knee arthroplasty? Knee Surg Sports Traumatol Arthrosc 21(10):2248–2254CrossRefPubMed
2.
go back to reference Bargren JH, Blaha JD, Freeman MA (1983) Alignment in total knee arthroplasty. Correlated biomechanical and clinical observations. Clin Orthop Relat Res 173:178–183 Bargren JH, Blaha JD, Freeman MA (1983) Alignment in total knee arthroplasty. Correlated biomechanical and clinical observations. Clin Orthop Relat Res 173:178–183
3.
go back to reference Berend ME, Ritter MA, Meding JB et al (2004) Tibial component failure mechanisms in total knee arthroplasty. Clin Orthop Relat Res 428:26–34CrossRef Berend ME, Ritter MA, Meding JB et al (2004) Tibial component failure mechanisms in total knee arthroplasty. Clin Orthop Relat Res 428:26–34CrossRef
4.
go back to reference Berger RA, Crossett LS, Jacobs JJ et al (1998) Malrotation causing patellofemoral complications after total knee arthroplasty. Clin Orthop Relat Res 356:144–153CrossRef Berger RA, Crossett LS, Jacobs JJ et al (1998) Malrotation causing patellofemoral complications after total knee arthroplasty. Clin Orthop Relat Res 356:144–153CrossRef
5.
go back to reference Bäthis H, Perlick L, Tingart M et al (2005) Intraoperative cutting errors in total knee arthroplasty. Arch Orthop Trauma Surg 125(1):16–20CrossRefPubMed Bäthis H, Perlick L, Tingart M et al (2005) Intraoperative cutting errors in total knee arthroplasty. Arch Orthop Trauma Surg 125(1):16–20CrossRefPubMed
6.
go back to reference Chen JY, Chin PL, Tay DK et al (2014) Less outliers in pinless navigation compared with conventional surgery in total knee arthroplasty. Knee Surg Sports Traumatol Arthrosc 22(8):1827–1832CrossRefPubMed Chen JY, Chin PL, Tay DK et al (2014) Less outliers in pinless navigation compared with conventional surgery in total knee arthroplasty. Knee Surg Sports Traumatol Arthrosc 22(8):1827–1832CrossRefPubMed
7.
go back to reference Chua KH, Chen Y, Lingaraj K (2014) Navigated total knee arthroplasty: is it error-free? Knee Surg Sports Traumatol Arthrosc 22(3):643–649CrossRefPubMed Chua KH, Chen Y, Lingaraj K (2014) Navigated total knee arthroplasty: is it error-free? Knee Surg Sports Traumatol Arthrosc 22(3):643–649CrossRefPubMed
8.
go back to reference Ensini A, Timoncini A, Cenni F et al (2014) Intra- and post-operative accuracy assessments of two different patient-specific instrumentation systems for total knee replacement. Knee Surg Sports Traumatol Arthrosc 22(3):621–629CrossRefPubMed Ensini A, Timoncini A, Cenni F et al (2014) Intra- and post-operative accuracy assessments of two different patient-specific instrumentation systems for total knee replacement. Knee Surg Sports Traumatol Arthrosc 22(3):621–629CrossRefPubMed
9.
go back to reference Hasegawa M, Yoshida K, Wakabayashi H et al (2013) Cutting and implanting errors in minimally invasive total knee arthroplasty using a navigation system. Int Orthop 37(1):27–30CrossRefPubMed Hasegawa M, Yoshida K, Wakabayashi H et al (2013) Cutting and implanting errors in minimally invasive total knee arthroplasty using a navigation system. Int Orthop 37(1):27–30CrossRefPubMed
11.
go back to reference Inui H, Taketomi S, Yamagami R et al (2016) Twice cutting method reduces tibial cutting error in unicompartmental knee arthroplasty. Knee 23(1):173–176CrossRefPubMed Inui H, Taketomi S, Yamagami R et al (2016) Twice cutting method reduces tibial cutting error in unicompartmental knee arthroplasty. Knee 23(1):173–176CrossRefPubMed
12.
go back to reference Iorio R, Bolle G, Conteduca F et al (2013) Accuracy of manual instrumentation of tibial cutting guide in total knee arthroplasty. Knee Surg Sports Traumatol Arthrosc 21(10):2296–2300CrossRefPubMed Iorio R, Bolle G, Conteduca F et al (2013) Accuracy of manual instrumentation of tibial cutting guide in total knee arthroplasty. Knee Surg Sports Traumatol Arthrosc 21(10):2296–2300CrossRefPubMed
13.
go back to reference Iorio R, Mazza D, Bolle G et al (2013) Computer-assisted surgery: a teacher of TKAs. Knee 20(4):232–235CrossRefPubMed Iorio R, Mazza D, Bolle G et al (2013) Computer-assisted surgery: a teacher of TKAs. Knee 20(4):232–235CrossRefPubMed
14.
go back to reference Jeffery RS, Morris RW, Denham RA (1991) Coronal alignment after total knee replacement. J Bone Joint Surg Br 73(5):709–714CrossRefPubMed Jeffery RS, Morris RW, Denham RA (1991) Coronal alignment after total knee replacement. J Bone Joint Surg Br 73(5):709–714CrossRefPubMed
15.
go back to reference Khodadadyan-Klostermann C, von Seebach M, Seebach M, Taylor WR, Duda GN, Haas NP (2004) Distribution of bone mineral density with age and gender in the proximal tibia. Clin Biomech (Bristol, Avon) 19(4):370–376CrossRef Khodadadyan-Klostermann C, von Seebach M, Seebach M, Taylor WR, Duda GN, Haas NP (2004) Distribution of bone mineral density with age and gender in the proximal tibia. Clin Biomech (Bristol, Avon) 19(4):370–376CrossRef
16.
go back to reference Kim TK, Chang CB, Kang YG et al (2010) Execution accuracy of bone resection and implant fixation in computer assisted minimally invasive total knee arthroplasty. Knee 17(1):23–28CrossRefPubMed Kim TK, Chang CB, Kang YG et al (2010) Execution accuracy of bone resection and implant fixation in computer assisted minimally invasive total knee arthroplasty. Knee 17(1):23–28CrossRefPubMed
17.
go back to reference Lotke PA, Ecker ML (1977) Influence of positioning of prosthesis in total knee replacement. J Bone Joint Surg Am 59(1):77–79CrossRefPubMed Lotke PA, Ecker ML (1977) Influence of positioning of prosthesis in total knee replacement. J Bone Joint Surg Am 59(1):77–79CrossRefPubMed
18.
go back to reference Love GJ, Kinninmonth AW (2013) Training benefits of computer navigated total knee arthroplasty. Knee 20(4):236–241CrossRefPubMed Love GJ, Kinninmonth AW (2013) Training benefits of computer navigated total knee arthroplasty. Knee 20(4):236–241CrossRefPubMed
19.
go back to reference Lustig S, Fleury C, Goy D et al (2011) The accuracy of acquisition of an imageless computer-assisted system and its implication for knee arthroplasty. Knee 18(1):15–20CrossRefPubMed Lustig S, Fleury C, Goy D et al (2011) The accuracy of acquisition of an imageless computer-assisted system and its implication for knee arthroplasty. Knee 18(1):15–20CrossRefPubMed
20.
go back to reference Minns RJ (1992) Surgical instrument design for the accurate cutting of bone for implant fixation. Clin Mater 10(4):207–212CrossRefPubMed Minns RJ (1992) Surgical instrument design for the accurate cutting of bone for implant fixation. Clin Mater 10(4):207–212CrossRefPubMed
21.
go back to reference Ohmori T, Maeda T, Kabata T, Kajino Y, Iwai S, Tsuchiya H (2015) The Accuracy of initial bone cutting in total knee arthroplasty. Open J Orthop 5:297–304CrossRef Ohmori T, Maeda T, Kabata T, Kajino Y, Iwai S, Tsuchiya H (2015) The Accuracy of initial bone cutting in total knee arthroplasty. Open J Orthop 5:297–304CrossRef
22.
go back to reference Otani T, Whiteside LA, White SE (1993) Cutting errors in preparation of femoral components in total knee arthroplasty. J Arthroplasty 8(5):503–510CrossRefPubMed Otani T, Whiteside LA, White SE (1993) Cutting errors in preparation of femoral components in total knee arthroplasty. J Arthroplasty 8(5):503–510CrossRefPubMed
23.
go back to reference Plaskos C, Hodgson AJ, Inkpen K et al (2002) Bone cutting errors in total knee arthroplasty. J Arthroplasty 17(6):698–705CrossRefPubMed Plaskos C, Hodgson AJ, Inkpen K et al (2002) Bone cutting errors in total knee arthroplasty. J Arthroplasty 17(6):698–705CrossRefPubMed
24.
go back to reference Ritter MA, Davis KE, Meding JB et al (2011) The effect of alignment and BMI on failure of total knee replacement. J Bone Joint Surg Am 93(17):1588–1596CrossRefPubMed Ritter MA, Davis KE, Meding JB et al (2011) The effect of alignment and BMI on failure of total knee replacement. J Bone Joint Surg Am 93(17):1588–1596CrossRefPubMed
25.
go back to reference Scholes C, Sahni V, Lustig S et al (2014) Patient-specific instrumentation for total knee arthroplasty does not match the pre-operative plan as assessed by intra-operative computer-assisted navigation. Knee Surg Sports Traumatol Arthrosc 22(3):660–665CrossRefPubMed Scholes C, Sahni V, Lustig S et al (2014) Patient-specific instrumentation for total knee arthroplasty does not match the pre-operative plan as assessed by intra-operative computer-assisted navigation. Knee Surg Sports Traumatol Arthrosc 22(3):660–665CrossRefPubMed
26.
go back to reference Teeny SM, Krackow KA, Hungerford DS et al (1991) Primary total knee arthroplasty in patients with severe varus deformity. A comparative study. Clin Orthop Relat Res 273:19–31 Teeny SM, Krackow KA, Hungerford DS et al (1991) Primary total knee arthroplasty in patients with severe varus deformity. A comparative study. Clin Orthop Relat Res 273:19–31
27.
go back to reference Terauchi M, Shirakura K, Katayama M, Higuchi H, Takagishi K (1998) The influence of osteoporosis on varus osteoarthritis of the knee. J Bone Joint Surg Br 80(3):432–436CrossRefPubMed Terauchi M, Shirakura K, Katayama M, Higuchi H, Takagishi K (1998) The influence of osteoporosis on varus osteoarthritis of the knee. J Bone Joint Surg Br 80(3):432–436CrossRefPubMed
28.
go back to reference Yau WP, Chiu KY (2008) Cutting errors in total knee replacement: assessment by computer assisted surgery. Knee Surg Sports Traumatol Arthrosc 16(7):670–673CrossRefPubMed Yau WP, Chiu KY (2008) Cutting errors in total knee replacement: assessment by computer assisted surgery. Knee Surg Sports Traumatol Arthrosc 16(7):670–673CrossRefPubMed
Metadata
Title
Case-related factors affecting cutting errors of the proximal tibia in total knee arthroplasty assessed by computer navigation
Authors
Tadashi Tsukeoka
Yoshikazu Tsuneizumi
Kensuke Yoshino
Mashiko Suzuki
Publication date
01-05-2018
Publisher
Springer Berlin Heidelberg
Published in
Knee Surgery, Sports Traumatology, Arthroscopy / Issue 5/2018
Print ISSN: 0942-2056
Electronic ISSN: 1433-7347
DOI
https://doi.org/10.1007/s00167-016-4397-2

Other articles of this Issue 5/2018

Knee Surgery, Sports Traumatology, Arthroscopy 5/2018 Go to the issue