Skip to main content
Top
Published in: Knee Surgery, Sports Traumatology, Arthroscopy 9/2016

01-09-2016 | Knee

Different intraoperative kinematics with comparable clinical outcomes of ultracongruent and posterior stabilized mobile-bearing total knee arthroplasty

Authors: Tae Woo Kim, Sang Min Lee, Sang Cheol Seong, Sahnghoon Lee, Jak Jang, Myung Chul Lee

Published in: Knee Surgery, Sports Traumatology, Arthroscopy | Issue 9/2016

Login to get access

Abstract

Purpose

There remains no consensus as to whether mobile total knee arthroplasty (TKA) should use a posterior cruciate ligament-sacrificing ultracongruent (UC) or a posterior cruciate ligament-substituting posterior stabilized (PS) prosthesis. The purpose of this study was to assess intraoperative kinematics and clinical outcomes of UC and PS rotating platform mobile-bearing TKA.

Methods

In this randomized controlled study, mobile UC TKA prostheses (n = 45) were compared with mobile PS TKA prostheses (n = 45) with regard to intraoperative kinematics and clinical outcomes. The passive kinematic study using intraoperative navigation system included anterior/posterior translation, varus/valgus alignment and rotation of femur during flexion. The patients were clinically and radiographically evaluated over a 3-year follow-up.

Results

Paradoxical anterior translation of the femur was 10.8 ± 5.2 mm in the UC knee from 0° to 82° of knee flexion and 8.7 ± 3.0 mm in the PS knee from 0° to 70° of knee flexion (p = 0.027). Paradoxical internal rotation of the femur was 5.8° in the UC knees and 9.9° in the PS knees (p = 0.003). But, there was no significant difference between the groups in regard to the coronal alignment. There was no significant difference in the range of motion, KS knee scores, KS function scores, and WOMAC index scores.

Conclusions

Despite different intraoperative kinematics between mobile UC and mobile PS TKA, neither design reproduced physiologic knee kinematics and there was no difference in clinical outcomes between the two groups. The clinical relevance of the study is that despite different intraoperative kinematics, UC design can be a considerable alternative to PS design in mobile-bearing TKA in respect of clinical outcomes.

Level of evidence

II.
Literature
1.
go back to reference Argenson JN, Scuderi GR, Komistek RD, Scott WN, Kelly MA, Aubaniac JM (2005) In vivo kinematic evaluation and design considerations related to high flexion in total knee arthroplasty. J Biomech 38(2):277–284CrossRefPubMed Argenson JN, Scuderi GR, Komistek RD, Scott WN, Kelly MA, Aubaniac JM (2005) In vivo kinematic evaluation and design considerations related to high flexion in total knee arthroplasty. J Biomech 38(2):277–284CrossRefPubMed
2.
go back to reference Bellemans J, Banks S, Victor J, Vandenneucker H, Moemans A (2002) Fluoroscopic analysis of the kinematics of deep flexion in total knee arthroplasty. Influence of posterior condylar offset. J Bone Joint Surg Br 84(1):50–53CrossRefPubMed Bellemans J, Banks S, Victor J, Vandenneucker H, Moemans A (2002) Fluoroscopic analysis of the kinematics of deep flexion in total knee arthroplasty. Influence of posterior condylar offset. J Bone Joint Surg Br 84(1):50–53CrossRefPubMed
3.
go back to reference Bignozzi S, Zaffagnini S, Akkawi I, Marko T, Bruni D, Neri MP, Colle F, Marcacci M (2014) Three different cruciate-sacrificing TKA designs: minor intraoperative kinematic differences and negligible clinical differences. Knee Surg Sports Traumatol Arthrosc 22(12):3113–3120CrossRefPubMed Bignozzi S, Zaffagnini S, Akkawi I, Marko T, Bruni D, Neri MP, Colle F, Marcacci M (2014) Three different cruciate-sacrificing TKA designs: minor intraoperative kinematic differences and negligible clinical differences. Knee Surg Sports Traumatol Arthrosc 22(12):3113–3120CrossRefPubMed
4.
go back to reference Blunn GW, Joshi AB, Minns RJ, Lidgren L, Lilley P, Ryd L, Engelbrecht E, Walker PS (1997) Wear in retrieved condylar knee arthroplasties. A comparison of wear in different designs of 280 retrieved condylar knee prostheses. J Arthroplasty 12(3):281–290CrossRefPubMed Blunn GW, Joshi AB, Minns RJ, Lidgren L, Lilley P, Ryd L, Engelbrecht E, Walker PS (1997) Wear in retrieved condylar knee arthroplasties. A comparison of wear in different designs of 280 retrieved condylar knee prostheses. J Arthroplasty 12(3):281–290CrossRefPubMed
5.
go back to reference Casino D, Zaffagnini S, Martelli S, Lopomo N, Bignozzi S, Iacono F, Russo A, Marcacci M (2009) Intraoperative evaluation of total knee replacement: kinematic assessment with a navigation system. Knee Surg Sports Traumatol Arthrosc 17(4):369–373CrossRefPubMed Casino D, Zaffagnini S, Martelli S, Lopomo N, Bignozzi S, Iacono F, Russo A, Marcacci M (2009) Intraoperative evaluation of total knee replacement: kinematic assessment with a navigation system. Knee Surg Sports Traumatol Arthrosc 17(4):369–373CrossRefPubMed
6.
go back to reference Daniilidis K, Skwara A, Vieth V, Fuchs-Winkelmann S, Heindel W, Stuckmann V, Tibesku CO (2012) Highly conforming polyethylene inlays reduce the in vivo variability of knee joint kinematics after total knee arthroplasty. Knee 19(4):260–265CrossRefPubMed Daniilidis K, Skwara A, Vieth V, Fuchs-Winkelmann S, Heindel W, Stuckmann V, Tibesku CO (2012) Highly conforming polyethylene inlays reduce the in vivo variability of knee joint kinematics after total knee arthroplasty. Knee 19(4):260–265CrossRefPubMed
7.
go back to reference Dennis DA, Komistek RD, Mahfouz MR, Haas BD, Stiehl JB (2003) Multicenter determination of in vivo kinematics after total knee arthroplasty. Clin Orthop Relat Res 416:37–57CrossRefPubMed Dennis DA, Komistek RD, Mahfouz MR, Haas BD, Stiehl JB (2003) Multicenter determination of in vivo kinematics after total knee arthroplasty. Clin Orthop Relat Res 416:37–57CrossRefPubMed
8.
go back to reference Dennis DA, Komistek RD, Mahfouz MR, Outten JT, Sharma A (2005) Mobile-bearing total knee arthroplasty: do the polyethylene bearings rotate? Clin Orthop Relat Res 440:88–95CrossRefPubMed Dennis DA, Komistek RD, Mahfouz MR, Outten JT, Sharma A (2005) Mobile-bearing total knee arthroplasty: do the polyethylene bearings rotate? Clin Orthop Relat Res 440:88–95CrossRefPubMed
9.
go back to reference Dennis DA, Komistek RD, Mahfouz MR, Walker SA, Tucker A (2004) A multicenter analysis of axial femorotibial rotation after total knee arthroplasty. Clin Orthop Relat Res 428:180–189CrossRefPubMed Dennis DA, Komistek RD, Mahfouz MR, Walker SA, Tucker A (2004) A multicenter analysis of axial femorotibial rotation after total knee arthroplasty. Clin Orthop Relat Res 428:180–189CrossRefPubMed
10.
go back to reference Fantozzi S, Catani F, Ensini A, Leardini A, Giannini S (2006) Femoral rollback of cruciate-retaining and posterior-stabilized total knee replacements: in vivo fluoroscopic analysis during activities of daily living. J Orthop Res 24(12):2222–2229CrossRefPubMed Fantozzi S, Catani F, Ensini A, Leardini A, Giannini S (2006) Femoral rollback of cruciate-retaining and posterior-stabilized total knee replacements: in vivo fluoroscopic analysis during activities of daily living. J Orthop Res 24(12):2222–2229CrossRefPubMed
11.
go back to reference Fitzpatrick CK, Clary CW, Cyr AJ, Maletsky LP, Rullkoetter PJ (2013) Mechanics of post-cam engagement during simulated dynamic activity. J Orthop Res 31(9):1438–1446CrossRefPubMedPubMedCentral Fitzpatrick CK, Clary CW, Cyr AJ, Maletsky LP, Rullkoetter PJ (2013) Mechanics of post-cam engagement during simulated dynamic activity. J Orthop Res 31(9):1438–1446CrossRefPubMedPubMedCentral
12.
go back to reference Hamai S, Miura H, Higaki H, Shimoto T, Nakanishi Y, Iwamoto Y (2008) Kinematic analysis of mobile-bearing total knee arthroplasty using a 6-DOF knee simulator. J Orthop Sci 13(6):543–549CrossRefPubMed Hamai S, Miura H, Higaki H, Shimoto T, Nakanishi Y, Iwamoto Y (2008) Kinematic analysis of mobile-bearing total knee arthroplasty using a 6-DOF knee simulator. J Orthop Sci 13(6):543–549CrossRefPubMed
13.
go back to reference Hauschild O, Konstantinidis L, Strohm PC, Niemeyer P, Suedkamp NP, Helwig P (2009) Reliability of leg alignment using the OrthoPilot system depends on knee position: a cadaveric study. Knee Surg Sports Traumatol Arthrosc 17(10):1143–1151CrossRefPubMed Hauschild O, Konstantinidis L, Strohm PC, Niemeyer P, Suedkamp NP, Helwig P (2009) Reliability of leg alignment using the OrthoPilot system depends on knee position: a cadaveric study. Knee Surg Sports Traumatol Arthrosc 17(10):1143–1151CrossRefPubMed
14.
go back to reference Heyse TJ, Becher C, Kron N, Ostermeier S, Hurschler C, Schofer MD, Tibesku CO, Fuchs-Winkelmann S (2010) Patellofemoral pressure after TKA in vitro: highly conforming vs. posterior stabilized inlays. Arch Orthop Trauma Surg 130(2):191–196CrossRefPubMed Heyse TJ, Becher C, Kron N, Ostermeier S, Hurschler C, Schofer MD, Tibesku CO, Fuchs-Winkelmann S (2010) Patellofemoral pressure after TKA in vitro: highly conforming vs. posterior stabilized inlays. Arch Orthop Trauma Surg 130(2):191–196CrossRefPubMed
15.
go back to reference Hilding MB, Lanshammar H, Ryd L (1996) Knee joint loading and tibial component loosening. RSA and gait analysis in 45 osteoarthritic patients before and after TKA. J Bone Joint Surg Br 78(1):66–73PubMed Hilding MB, Lanshammar H, Ryd L (1996) Knee joint loading and tibial component loosening. RSA and gait analysis in 45 osteoarthritic patients before and after TKA. J Bone Joint Surg Br 78(1):66–73PubMed
16.
go back to reference Hofmann AA, Tkach TK, Evanich CJ, Camargo MP (2000) Posterior stabilization in total knee arthroplasty with use of an ultracongruent polyethylene insert. J Arthroplasty 15(5):576–583CrossRefPubMed Hofmann AA, Tkach TK, Evanich CJ, Camargo MP (2000) Posterior stabilization in total knee arthroplasty with use of an ultracongruent polyethylene insert. J Arthroplasty 15(5):576–583CrossRefPubMed
17.
go back to reference Hozack WJ, Rothman RH, Booth RE Jr, Balderston RA (1989) The patellar clunk syndrome. A complication of posterior stabilized total knee arthroplasty. Clin Orthop Relat Res 241:203–208PubMed Hozack WJ, Rothman RH, Booth RE Jr, Balderston RA (1989) The patellar clunk syndrome. A complication of posterior stabilized total knee arthroplasty. Clin Orthop Relat Res 241:203–208PubMed
18.
go back to reference Kim JIOK, Jeon SH, Choi HW (2011) Short-term results of posterior cruciate sacrificing and substitution total knee arthroplasty. Knee Surg Relat Res 23:79–87 Kim JIOK, Jeon SH, Choi HW (2011) Short-term results of posterior cruciate sacrificing and substitution total knee arthroplasty. Knee Surg Relat Res 23:79–87
19.
go back to reference Kim YH, Kim JS, Park JW, Joo JH (2011) Comparison of the low contact stress and press fit condylar rotating-platform mobile-bearing prostheses in total knee arthroplasty: a prospective randomized study. J Bone Joint Surg Am 93(11):1001–1007PubMed Kim YH, Kim JS, Park JW, Joo JH (2011) Comparison of the low contact stress and press fit condylar rotating-platform mobile-bearing prostheses in total knee arthroplasty: a prospective randomized study. J Bone Joint Surg Am 93(11):1001–1007PubMed
20.
go back to reference Lachiewicz PF, Soileau ES (2009) Fifteen-year survival and osteolysis associated with a modular posterior stabilized knee replacement. A concise follow-up of a previous report. J Bone Joint Surg Am 91(6):1419–1423CrossRefPubMed Lachiewicz PF, Soileau ES (2009) Fifteen-year survival and osteolysis associated with a modular posterior stabilized knee replacement. A concise follow-up of a previous report. J Bone Joint Surg Am 91(6):1419–1423CrossRefPubMed
21.
go back to reference Laskin RS, Maruyama Y, Villaneuva M, Bourne R (2000) Deep-dish congruent tibial component use in total knee arthroplasty: a randomized prospective study. Clin Orthop Relat Res 380:36–44CrossRefPubMed Laskin RS, Maruyama Y, Villaneuva M, Bourne R (2000) Deep-dish congruent tibial component use in total knee arthroplasty: a randomized prospective study. Clin Orthop Relat Res 380:36–44CrossRefPubMed
22.
go back to reference Lombardi AV Jr, Mallory TH, Waterman RA, Eberle RW (1995) Intercondylar distal femoral fracture. An unreported complication of posterior-stabilized total knee arthroplasty. J Arthroplasty 10(5):643–650CrossRefPubMed Lombardi AV Jr, Mallory TH, Waterman RA, Eberle RW (1995) Intercondylar distal femoral fracture. An unreported complication of posterior-stabilized total knee arthroplasty. J Arthroplasty 10(5):643–650CrossRefPubMed
23.
go back to reference Maruyama S, Yoshiya S, Matsui N, Kuroda R, Kurosaka M (2004) Functional comparison of posterior cruciate-retaining versus posterior stabilized total knee arthroplasty. J Arthroplasty 19(3):349–353CrossRefPubMed Maruyama S, Yoshiya S, Matsui N, Kuroda R, Kurosaka M (2004) Functional comparison of posterior cruciate-retaining versus posterior stabilized total knee arthroplasty. J Arthroplasty 19(3):349–353CrossRefPubMed
24.
go back to reference Matsuzaki T, Matsumoto T, Kubo S, Muratsu H, Matsushita T, Kawakami Y, Ishida K, Oka S, Kuroda R, Kurosaka M (2014) Tibial internal rotation is affected by lateral laxity in cruciate-retaining total knee arthroplasty: an intraoperative kinematic study using a navigation system and offset-type tensor. Knee Surg Sports Traumatol Arthrosc 22(3):615–620CrossRefPubMed Matsuzaki T, Matsumoto T, Kubo S, Muratsu H, Matsushita T, Kawakami Y, Ishida K, Oka S, Kuroda R, Kurosaka M (2014) Tibial internal rotation is affected by lateral laxity in cruciate-retaining total knee arthroplasty: an intraoperative kinematic study using a navigation system and offset-type tensor. Knee Surg Sports Traumatol Arthrosc 22(3):615–620CrossRefPubMed
25.
go back to reference Mikulak SA, Mahoney OM, dela Rosa MA, Schmalzried TP (2001) Loosening and osteolysis with the press-fit condylar posterior-cruciate-substituting total knee replacement. J Bone Joint Surg Am 83-A(3):398–403PubMed Mikulak SA, Mahoney OM, dela Rosa MA, Schmalzried TP (2001) Loosening and osteolysis with the press-fit condylar posterior-cruciate-substituting total knee replacement. J Bone Joint Surg Am 83-A(3):398–403PubMed
26.
go back to reference Ploegmakers MJ, Ginsel B, Meijerink HJ, de Rooy JW, de Waal Malefijt MC, Verdonschot N, Banks SA (2010) Physical examination and in vivo kinematics in two posterior cruciate ligament retaining total knee arthroplasty designs. Knee 17(3):204–209CrossRefPubMed Ploegmakers MJ, Ginsel B, Meijerink HJ, de Rooy JW, de Waal Malefijt MC, Verdonschot N, Banks SA (2010) Physical examination and in vivo kinematics in two posterior cruciate ligament retaining total knee arthroplasty designs. Knee 17(3):204–209CrossRefPubMed
27.
go back to reference Puloski SK, McCalden RW, MacDonald SJ, Rorabeck CH, Bourne RB (2001) Tibial post wear in posterior stabilized total knee arthroplasty. An unrecognized source of polyethylene debris. J Bone Joint Surg Am 83-A(3):390–397PubMed Puloski SK, McCalden RW, MacDonald SJ, Rorabeck CH, Bourne RB (2001) Tibial post wear in posterior stabilized total knee arthroplasty. An unrecognized source of polyethylene debris. J Bone Joint Surg Am 83-A(3):390–397PubMed
28.
go back to reference Roh YW, Jang J, Choi WC, Lee JK, Chun SH, Lee S, Seong SC, Lee MC (2013) Preservation of the posterior cruciate ligament is not helpful in highly conforming mobile-bearing total knee arthroplasty: a randomized controlled study. Knee Surg Sports Traumatol Arthrosc 21(12):2850–2859CrossRefPubMed Roh YW, Jang J, Choi WC, Lee JK, Chun SH, Lee S, Seong SC, Lee MC (2013) Preservation of the posterior cruciate ligament is not helpful in highly conforming mobile-bearing total knee arthroplasty: a randomized controlled study. Knee Surg Sports Traumatol Arthrosc 21(12):2850–2859CrossRefPubMed
29.
go back to reference Siston RA, Daub AC, Giori NJ, Goodman SB, Delp SL (2005) Evaluation of methods that locate the center of the ankle for computer-assisted total knee arthroplasty. Clin Orthop Relat Res 439:129–135CrossRefPubMed Siston RA, Daub AC, Giori NJ, Goodman SB, Delp SL (2005) Evaluation of methods that locate the center of the ankle for computer-assisted total knee arthroplasty. Clin Orthop Relat Res 439:129–135CrossRefPubMed
30.
go back to reference Siston RA, Delp SL (2006) Evaluation of a new algorithm to determine the hip joint center. J Biomech 39(1):125–130CrossRefPubMed Siston RA, Delp SL (2006) Evaluation of a new algorithm to determine the hip joint center. J Biomech 39(1):125–130CrossRefPubMed
31.
go back to reference Siston RA, Giori NJ, Goodman SB, Delp SL (2006) Intraoperative passive kinematics of osteoarthritic knees before and after total knee arthroplasty. J Orthop Res 24(8):1607–1614CrossRefPubMed Siston RA, Giori NJ, Goodman SB, Delp SL (2006) Intraoperative passive kinematics of osteoarthritic knees before and after total knee arthroplasty. J Orthop Res 24(8):1607–1614CrossRefPubMed
32.
go back to reference Suggs JF, Hanson GR, Park SE, Moynihan AL, Li G (2008) Patient function after a posterior stabilizing total knee arthroplasty: cam-post engagement and knee kinematics. Knee Surg Sports Traumatol Arthrosc 16(3):290–296CrossRefPubMed Suggs JF, Hanson GR, Park SE, Moynihan AL, Li G (2008) Patient function after a posterior stabilizing total knee arthroplasty: cam-post engagement and knee kinematics. Knee Surg Sports Traumatol Arthrosc 16(3):290–296CrossRefPubMed
33.
go back to reference Uvehammer J, Karrholm J, Regner L, Carlsson L, Herberts P (2001) Concave versus posterior-stabilized tibial joint surface in total knee arthroplasty: randomized evaluation of 47 knees. J Arthroplasty 16(1):25–32CrossRefPubMed Uvehammer J, Karrholm J, Regner L, Carlsson L, Herberts P (2001) Concave versus posterior-stabilized tibial joint surface in total knee arthroplasty: randomized evaluation of 47 knees. J Arthroplasty 16(1):25–32CrossRefPubMed
34.
go back to reference Wasielewski RC, Komistek RD, Zingde SM, Sheridan KC, Mahfouz MR (2008) Lack of axial rotation in mobile-bearing knee designs. Clin Orthop Relat Res 466(11):2662–2668CrossRefPubMedPubMedCentral Wasielewski RC, Komistek RD, Zingde SM, Sheridan KC, Mahfouz MR (2008) Lack of axial rotation in mobile-bearing knee designs. Clin Orthop Relat Res 466(11):2662–2668CrossRefPubMedPubMedCentral
35.
go back to reference Wolterbeek N, Garling EH, Mertens BJ, van der Linden HM, Nelissen RG, Valstar ER (2012) Kinematics of a highly congruent mobile-bearing total knee prosthesis. Knee Surg Sports Traumatol Arthrosc 20(12):2487–2493CrossRefPubMed Wolterbeek N, Garling EH, Mertens BJ, van der Linden HM, Nelissen RG, Valstar ER (2012) Kinematics of a highly congruent mobile-bearing total knee prosthesis. Knee Surg Sports Traumatol Arthrosc 20(12):2487–2493CrossRefPubMed
36.
go back to reference Yoshiya S, Matsui N, Komistek RD, Dennis DA, Mahfouz M, Kurosaka M (2005) In vivo kinematic comparison of posterior cruciate-retaining and posterior stabilized total knee arthroplasties under passive and weight-bearing conditions. J Arthroplasty 20(6):777–783CrossRefPubMed Yoshiya S, Matsui N, Komistek RD, Dennis DA, Mahfouz M, Kurosaka M (2005) In vivo kinematic comparison of posterior cruciate-retaining and posterior stabilized total knee arthroplasties under passive and weight-bearing conditions. J Arthroplasty 20(6):777–783CrossRefPubMed
37.
go back to reference Zingde SM, Leszko F, Sharma A, Mahfouz MR, Komistek RD, Dennis DA (2014) In vivo determination of cam-post engagement in fixed and mobile-bearing TKA. Clin Orthop Relat Res 472(1):254–262CrossRefPubMed Zingde SM, Leszko F, Sharma A, Mahfouz MR, Komistek RD, Dennis DA (2014) In vivo determination of cam-post engagement in fixed and mobile-bearing TKA. Clin Orthop Relat Res 472(1):254–262CrossRefPubMed
Metadata
Title
Different intraoperative kinematics with comparable clinical outcomes of ultracongruent and posterior stabilized mobile-bearing total knee arthroplasty
Authors
Tae Woo Kim
Sang Min Lee
Sang Cheol Seong
Sahnghoon Lee
Jak Jang
Myung Chul Lee
Publication date
01-09-2016
Publisher
Springer Berlin Heidelberg
Published in
Knee Surgery, Sports Traumatology, Arthroscopy / Issue 9/2016
Print ISSN: 0942-2056
Electronic ISSN: 1433-7347
DOI
https://doi.org/10.1007/s00167-014-3489-0

Other articles of this Issue 9/2016

Knee Surgery, Sports Traumatology, Arthroscopy 9/2016 Go to the issue