Skip to main content
Top
Published in: Knee Surgery, Sports Traumatology, Arthroscopy 4/2009

01-04-2009 | Knee

Intraoperative evaluation of total knee replacement: kinematic assessment with a navigation system

Authors: Daniela Casino, Stefano Zaffagnini, Sandra Martelli, Nicola Lopomo, Simone Bignozzi, Francesco Iacono, Alessandro Russo, Maurilio Marcacci

Published in: Knee Surgery, Sports Traumatology, Arthroscopy | Issue 4/2009

Login to get access

Abstract

Interest in the kinematics of reconstructed knees has increased since it was shown that the alteration of knee motion could lead to abnormal wear and damage to soft tissues. We performed intraoperative kinematic measurements using a navigation system to study knee kinematics before and after posterior substituting rotating platform total knee arthroplasty (TKA). We verified intraoperatively (1) if varus/valgus (VV) laxity and anterior/posterior (AP) laxity were restored after TKA; (2) if TKA induced abnormal femoral rollback; and (3) how tibial axial rotation was influenced by TKA throughout the range of flexion. We found that TKA improved alignment in preoperative osteoarthritic varus knees which became neutral after surgery and maintained a neutral alignment in neutral knees. The VV stability at 0° was restored while AP laxity at 90° significantly increased after TKA. Following TKA, the femur had an abnormal anterior translation up to 60° of flexion, followed by a small rollback of 12 ± 5 mm. TKA influenced the tibia rotation pattern during flexion, but not the total amount of internal/external rotation throughout whole range of flexion, which was preserved after TKA (6° ± 5°). This study showed that the protocol proposed might be useful to adjust knee stability at time zero and that knee kinematic outcome during total knee replacement can be monitored by a navigation system.
Literature
1.
go back to reference Ahlbäck S (1968) Osteoarthrosis of the knee: a radiographic investigation. Acta Radiol Suppl 277:7–72 Ahlbäck S (1968) Osteoarthrosis of the knee: a radiographic investigation. Acta Radiol Suppl 277:7–72
2.
go back to reference Banks SA, Markovich GD, Hodge WA (1997) In vivo kinematics of cruciate-retaining and -substituting knee arthroplasties. J Arthroplasty 12:297–304PubMedCrossRef Banks SA, Markovich GD, Hodge WA (1997) In vivo kinematics of cruciate-retaining and -substituting knee arthroplasties. J Arthroplasty 12:297–304PubMedCrossRef
3.
go back to reference Boyer P, Djian P, Christel P, Paoletti X, Degeorges R (2004) Reliability of the KT-1000 arthrometer (Medmetric) for measuring anterior knee laxity: comparison with Telos in 147 knees. Rev Chir Orthop Reparatrice Appar Mot 90:757–764PubMed Boyer P, Djian P, Christel P, Paoletti X, Degeorges R (2004) Reliability of the KT-1000 arthrometer (Medmetric) for measuring anterior knee laxity: comparison with Telos in 147 knees. Rev Chir Orthop Reparatrice Appar Mot 90:757–764PubMed
4.
go back to reference D’Lima DD, Hermida JC, Chen PC, Colwell CW Jr (2001) Polyethylene wear and variations in knee kinematics. Clin Orthop Relat Res 392:124–130PubMedCrossRef D’Lima DD, Hermida JC, Chen PC, Colwell CW Jr (2001) Polyethylene wear and variations in knee kinematics. Clin Orthop Relat Res 392:124–130PubMedCrossRef
5.
go back to reference Dennis DA, Komistek RD, Colwell CE Jr, Ranawat CS, Scott RD, Thornhill TS, Lapp MA (1998) In vivo anteroposterior femorotibial translation of total knee arthroplasty: a multicenter analysis. Clin Orthop Relat Res 356:47–57PubMedCrossRef Dennis DA, Komistek RD, Colwell CE Jr, Ranawat CS, Scott RD, Thornhill TS, Lapp MA (1998) In vivo anteroposterior femorotibial translation of total knee arthroplasty: a multicenter analysis. Clin Orthop Relat Res 356:47–57PubMedCrossRef
6.
go back to reference Dennis DA, Komistek RD, Hoff WA, Gabriel SM (1996) In vivo knee kinematics derived using an inverse perspective technique. Clin Orthop Relat Res 331:107–117PubMedCrossRef Dennis DA, Komistek RD, Hoff WA, Gabriel SM (1996) In vivo knee kinematics derived using an inverse perspective technique. Clin Orthop Relat Res 331:107–117PubMedCrossRef
7.
go back to reference Dennis DA, Komistek RD, Mahfouz MR, Haas BD, Stiehl JB (2003) Multicenter determination of in vivo kinematics after total knee arthroplasty. Clin Orthop Relat Res 416:37–57PubMedCrossRef Dennis DA, Komistek RD, Mahfouz MR, Haas BD, Stiehl JB (2003) Multicenter determination of in vivo kinematics after total knee arthroplasty. Clin Orthop Relat Res 416:37–57PubMedCrossRef
8.
go back to reference Delport HP, Banks SA, De Schepper J, Bellemans J (2006) A kinematic comparison of fixed- and mobile-bearing knee replacements. J Bone Joint Surg Br 88:1016–1021PubMedCrossRef Delport HP, Banks SA, De Schepper J, Bellemans J (2006) A kinematic comparison of fixed- and mobile-bearing knee replacements. J Bone Joint Surg Br 88:1016–1021PubMedCrossRef
9.
go back to reference Ho FY, Ma HM, Liau JJ, Yeh CR, Huang CH (2007) Mobile-bearing knees reduce rotational asymmetric wear. Clin Orthop Relat Res 462:143–149PubMedCrossRef Ho FY, Ma HM, Liau JJ, Yeh CR, Huang CH (2007) Mobile-bearing knees reduce rotational asymmetric wear. Clin Orthop Relat Res 462:143–149PubMedCrossRef
10.
go back to reference Fornalski S, McGarry MH, Csintalan RP, Fithian DC, Lee TQ (2008) Biomechanical and anatomical assessment after knee hyperextension injury. Am J Sports Med 36:80–84PubMedCrossRef Fornalski S, McGarry MH, Csintalan RP, Fithian DC, Lee TQ (2008) Biomechanical and anatomical assessment after knee hyperextension injury. Am J Sports Med 36:80–84PubMedCrossRef
11.
go back to reference Ganko L, Engebretsen L, Ozer H (2000) The rolimeter: a new arthrometer compared with the KT-1000. Knee Surg Sports Traumatol Arthrosc 8:36–39PubMedCrossRef Ganko L, Engebretsen L, Ozer H (2000) The rolimeter: a new arthrometer compared with the KT-1000. Knee Surg Sports Traumatol Arthrosc 8:36–39PubMedCrossRef
12.
go back to reference Grood ES, Suntay WJ (1983) A joint coordinate system for the clinical description of three-dimensional motions: application to the knee. J Biomech Eng 105:136–144PubMedCrossRef Grood ES, Suntay WJ (1983) A joint coordinate system for the clinical description of three-dimensional motions: application to the knee. J Biomech Eng 105:136–144PubMedCrossRef
13.
go back to reference Li G, Most E, Otterberg E, Sabbag K, Zayontz S, Johnson T, Rubash H (2002) Biomechanics of posterior-substituting total knee arthroplasty: an in vitro study. Clin Orthop Relat Res 404:214–225PubMedCrossRef Li G, Most E, Otterberg E, Sabbag K, Zayontz S, Johnson T, Rubash H (2002) Biomechanics of posterior-substituting total knee arthroplasty: an in vitro study. Clin Orthop Relat Res 404:214–225PubMedCrossRef
14.
go back to reference Lizaur A, Marco L, Cebrian R (1997) Preoperative factors influencing the range of movement after total knee arthroplasty for severe osteoarthritis. J Bone Joint Surg Br 79:626–629PubMedCrossRef Lizaur A, Marco L, Cebrian R (1997) Preoperative factors influencing the range of movement after total knee arthroplasty for severe osteoarthritis. J Bone Joint Surg Br 79:626–629PubMedCrossRef
15.
go back to reference Martelli S, Zaffagnini S, Bignozzi S, Lopomo NF, Iacono F, Marcacci M (2007) KIN-Nav navigation system for kinematic assessment in anterior cruciate ligament reconstruction: features, use, and perspectives. Proc Inst Mech Eng [H] 221:725–737 Martelli S, Zaffagnini S, Bignozzi S, Lopomo NF, Iacono F, Marcacci M (2007) KIN-Nav navigation system for kinematic assessment in anterior cruciate ligament reconstruction: features, use, and perspectives. Proc Inst Mech Eng [H] 221:725–737
16.
go back to reference Martelli S, Zaffagnini S, Bignozzi S, Bontempi M, Marcacci M (2006) Validation of a new protocol for computer-assisted evaluation of kinematics of double-bundle ACL reconstruction. Clin Biomech 21:279–287CrossRef Martelli S, Zaffagnini S, Bignozzi S, Bontempi M, Marcacci M (2006) Validation of a new protocol for computer-assisted evaluation of kinematics of double-bundle ACL reconstruction. Clin Biomech 21:279–287CrossRef
17.
go back to reference Matziolis G, Krocker D, Weiss U, Tohtz S, Perka C (2007) A prospective, randomized study of computer-assisted and conventional total knee arthroplasty. Three-dimensional evaluation of implant alignment and rotation. J Bone Joint Surg Am 89:236–243PubMedCrossRef Matziolis G, Krocker D, Weiss U, Tohtz S, Perka C (2007) A prospective, randomized study of computer-assisted and conventional total knee arthroplasty. Three-dimensional evaluation of implant alignment and rotation. J Bone Joint Surg Am 89:236–243PubMedCrossRef
18.
go back to reference Mihalko WM, Ali M, Phillips MJ, Bayers-Thering M, Krackow KA (2008) Passive knee kinematics before and after total knee arthroplasty: are we correcting pathologic motion? J Arthroplasty 23:57–60PubMedCrossRef Mihalko WM, Ali M, Phillips MJ, Bayers-Thering M, Krackow KA (2008) Passive knee kinematics before and after total knee arthroplasty: are we correcting pathologic motion? J Arthroplasty 23:57–60PubMedCrossRef
19.
go back to reference Moschella D, Blasi A, Leardini A, Ensini A, Catani F (2006) Wear patterns on tibial plateau from varus osteoarthritic knees. Clin Biomech 21:152–158CrossRef Moschella D, Blasi A, Leardini A, Ensini A, Catani F (2006) Wear patterns on tibial plateau from varus osteoarthritic knees. Clin Biomech 21:152–158CrossRef
20.
go back to reference Patel VV, Hall K, Ries M, Lotz J, Ozhinsky E, Lindsey C, Lu Y, Majumdar S (2004) A three-dimensional MRI analysis of knee kinematics. J Orthop Res 22:283–292PubMedCrossRef Patel VV, Hall K, Ries M, Lotz J, Ozhinsky E, Lindsey C, Lu Y, Majumdar S (2004) A three-dimensional MRI analysis of knee kinematics. J Orthop Res 22:283–292PubMedCrossRef
21.
go back to reference Patil S, Colwell CW Jr, Ezzet KA, D’Lima DD (2005) Can normal knee kinematics be restored with unicompartmental knee replacement? J Bone Joint Surg Am 87:332–338PubMedCrossRef Patil S, Colwell CW Jr, Ezzet KA, D’Lima DD (2005) Can normal knee kinematics be restored with unicompartmental knee replacement? J Bone Joint Surg Am 87:332–338PubMedCrossRef
22.
go back to reference Ranawat CS, Komistek RD, Rodriguez JA, Dennis DA, Anderle M (2004) In vivo kinematics for fixed and mobile-bearing posterior stabilized knee prostheses. Clin Orthop Relat Res 418:184–190PubMedCrossRef Ranawat CS, Komistek RD, Rodriguez JA, Dennis DA, Anderle M (2004) In vivo kinematics for fixed and mobile-bearing posterior stabilized knee prostheses. Clin Orthop Relat Res 418:184–190PubMedCrossRef
23.
go back to reference Siston RA, Giori NJ, Goodman SB, Delp SL (2006) Intra-operative passive kinematics of osteoarthritic knees before and after total knee arthroplasty. J Orthop Res 24:1607–1614PubMedCrossRef Siston RA, Giori NJ, Goodman SB, Delp SL (2006) Intra-operative passive kinematics of osteoarthritic knees before and after total knee arthroplasty. J Orthop Res 24:1607–1614PubMedCrossRef
24.
go back to reference Stiehl JB, Dennis DA, Komistek RD, Keblish PA (1997) Kinematic analysis of a mobile bearing total knee arthroplasty. Clin Orthop Relat Res 345:60–65PubMedCrossRef Stiehl JB, Dennis DA, Komistek RD, Keblish PA (1997) Kinematic analysis of a mobile bearing total knee arthroplasty. Clin Orthop Relat Res 345:60–65PubMedCrossRef
25.
go back to reference Suggs JF, Hanson GR, Park SE, Moynihan AL, Li G (2008) Patient function after a posterior stabilizing total knee arthroplasty: cam-post engagement and knee kinematics. Knee Surg Sports Traumatol Arthrosc 16:290–296PubMedCrossRef Suggs JF, Hanson GR, Park SE, Moynihan AL, Li G (2008) Patient function after a posterior stabilizing total knee arthroplasty: cam-post engagement and knee kinematics. Knee Surg Sports Traumatol Arthrosc 16:290–296PubMedCrossRef
26.
go back to reference Suggs JF, Li G, Park SE, Sultan PG, Rubash HE, Freiberg AA (2006) Knee biomechanics after UKA and its relation to the ACL—a robotic investigation. J Orthop Res 24:588–594PubMedCrossRef Suggs JF, Li G, Park SE, Sultan PG, Rubash HE, Freiberg AA (2006) Knee biomechanics after UKA and its relation to the ACL—a robotic investigation. J Orthop Res 24:588–594PubMedCrossRef
27.
go back to reference Zaffagnini S, Bignozzi S, Martelli S, Imakiire N, Lopomo N, Marcacci M (2006) New intra-operative protocol for kinematic evaluation of ACL reconstruction: preliminary results. Knee Surg Sports Traumatol Arthrosc 14:811–816PubMedCrossRef Zaffagnini S, Bignozzi S, Martelli S, Imakiire N, Lopomo N, Marcacci M (2006) New intra-operative protocol for kinematic evaluation of ACL reconstruction: preliminary results. Knee Surg Sports Traumatol Arthrosc 14:811–816PubMedCrossRef
Metadata
Title
Intraoperative evaluation of total knee replacement: kinematic assessment with a navigation system
Authors
Daniela Casino
Stefano Zaffagnini
Sandra Martelli
Nicola Lopomo
Simone Bignozzi
Francesco Iacono
Alessandro Russo
Maurilio Marcacci
Publication date
01-04-2009
Publisher
Springer-Verlag
Published in
Knee Surgery, Sports Traumatology, Arthroscopy / Issue 4/2009
Print ISSN: 0942-2056
Electronic ISSN: 1433-7347
DOI
https://doi.org/10.1007/s00167-008-0699-3

Other articles of this Issue 4/2009

Knee Surgery, Sports Traumatology, Arthroscopy 4/2009 Go to the issue