Skip to main content
Top
Published in: Knee Surgery, Sports Traumatology, Arthroscopy 11/2016

01-11-2016 | Knee

Superior alignment but no difference in clinical outcome after minimally invasive computer-assisted unicompartmental knee arthroplasty (MICA-UKA)

Authors: Zhenxiang Zhang, Wei Zhu, Lixian Zhu, Yaqing Du

Published in: Knee Surgery, Sports Traumatology, Arthroscopy | Issue 11/2016

Login to get access

Abstract

Purpose

Variety of clinical trials have been published comparing the alignment of MICA-UKA with MI-UKA. However, to the best of our knowledge, no published study has showed whether radiological alignment by MICA-UKA has influence on the clinical results. The present study was conducted to compare the short-term results of MICA-UKA with MI-UKA. It was hypothesized that better alignment as well as clinical results was achieved by MICA-UKA as compared to MI-UKA.

Methods

The clinical and radiological results of 87 subjects who underwent primary UKA using either minimally invasive and computer-assisted technique (45 patients Group A) or minimally invasive technique (42 patients, Group B) were reported. Knee Society scores (KSSs), Knee Society functional scores (KSFSs), range of motion (ROM), and radiographic results were assessed and reported preoperatively and at 24-month follow-up. Total blood loss, operative time, and length of skin incision were compared.

Results

The accuracy of the implantations in relation to the coronal mechanical axis in Group A was significantly superior to that of Group B (P = 0.033). The femoral rotational profile revealed the prosthesis in Group A that was implanted with significantly less internal rotation than Group B (P = 0.025). Clinical results, with regard to ROMs and KSSs, as well as KSFSs were equally good in both the groups. The average blood loss in patients of Group A was significantly reduced as compared to patients of Group B. No significant difference was detected in terms of operative time or length of skin incision.

Conclusions

It is suggested that MICA-UKA improves the implant alignment without increasing clinical results versus MI-UKA. We advocate that computer navigation should be considered when minimally invasive unicompartmental knee arthroplasty is performed.

Level of evidence

Therapeutic study, Level II.
Literature
1.
go back to reference Confalonieri N, Manzotti A (2005) Mini-invasive computer assisted bi-unicompartimental knee replacement. Int J Med Robot 1:45–50CrossRefPubMed Confalonieri N, Manzotti A (2005) Mini-invasive computer assisted bi-unicompartimental knee replacement. Int J Med Robot 1:45–50CrossRefPubMed
2.
go back to reference Fisher D, Almand J, Dalury D, Gonzales R, Watts M (2007) Minimally invasive unicompartmental knee arthroplasty: a comparison of all-polyethylene and metal-backed tibial components. J Arthroplasty 22:310–311CrossRef Fisher D, Almand J, Dalury D, Gonzales R, Watts M (2007) Minimally invasive unicompartmental knee arthroplasty: a comparison of all-polyethylene and metal-backed tibial components. J Arthroplasty 22:310–311CrossRef
3.
go back to reference Fisher DA, Dalury DF, Adams MJ, Shipps MR, Davis K (2010) Unicompartmental and total knee arthroplasty in the over 70 population. Orthopedics 33:668PubMed Fisher DA, Dalury DF, Adams MJ, Shipps MR, Davis K (2010) Unicompartmental and total knee arthroplasty in the over 70 population. Orthopedics 33:668PubMed
4.
go back to reference Jenny JY, Müller PE, Weyer R, John M, Weber P, Ciobanu E, Schmitz A, Bacher T, Neumann W, Jansson V (2006) Navigated minimally invasive unicompartmental knee arthroplasty. Orthopedics 29:117–121 Jenny JY, Müller PE, Weyer R, John M, Weber P, Ciobanu E, Schmitz A, Bacher T, Neumann W, Jansson V (2006) Navigated minimally invasive unicompartmental knee arthroplasty. Orthopedics 29:117–121
5.
go back to reference Jung KA, Kim SJ, Lee SC, Hwang SH, Ahn NK (2010) Accuracy of implantation during computer- assisted minimally invasive Oxford unicompartmental knee arthroplasty: a comparison with a conventional instrumented technique. Knee 17:387–391CrossRefPubMed Jung KA, Kim SJ, Lee SC, Hwang SH, Ahn NK (2010) Accuracy of implantation during computer- assisted minimally invasive Oxford unicompartmental knee arthroplasty: a comparison with a conventional instrumented technique. Knee 17:387–391CrossRefPubMed
6.
go back to reference Keene G, Simpson D, Kalairajah Y (2006) Limb alignment in computer-assisted minimally-invasive unicompartmental knee replacement. J Bone Joint Surg Br 88:44–48CrossRefPubMed Keene G, Simpson D, Kalairajah Y (2006) Limb alignment in computer-assisted minimally-invasive unicompartmental knee replacement. J Bone Joint Surg Br 88:44–48CrossRefPubMed
7.
go back to reference Lim MH, Tallay A, Bartlett J (2009) Comparative study of the use of computer assisted navigation system for axial correction in medial unicompartmental knee arthroplasty. Knee Surg Sports Traumatol Arthrosc 17:341–346CrossRefPubMed Lim MH, Tallay A, Bartlett J (2009) Comparative study of the use of computer assisted navigation system for axial correction in medial unicompartmental knee arthroplasty. Knee Surg Sports Traumatol Arthrosc 17:341–346CrossRefPubMed
8.
go back to reference Morris MJ, Frye BM, Ekpo TE, Berend KR (2012) Unicompartmental knee replacement with new Oxford instruments. Oper Tech Orthop 22:189–195CrossRef Morris MJ, Frye BM, Ekpo TE, Berend KR (2012) Unicompartmental knee replacement with new Oxford instruments. Oper Tech Orthop 22:189–195CrossRef
9.
go back to reference Mullaji AB, Sharma A, Marawar S (2007) Unicompartmental knee arthroplasty: functional recovery and radiographic results with a minimally invasive technique. J Arthroplasty 22:7–11CrossRefPubMed Mullaji AB, Sharma A, Marawar S (2007) Unicompartmental knee arthroplasty: functional recovery and radiographic results with a minimally invasive technique. J Arthroplasty 22:7–11CrossRefPubMed
10.
go back to reference Mullaji AB, Shetty GM, Kanna R (2011) Postoperative limb alignment and its determinants after minimally invasive Oxford medial unicompartmental knee arthroplasty. J Arthroplasty 26:919–925CrossRefPubMed Mullaji AB, Shetty GM, Kanna R (2011) Postoperative limb alignment and its determinants after minimally invasive Oxford medial unicompartmental knee arthroplasty. J Arthroplasty 26:919–925CrossRefPubMed
11.
go back to reference Munk S, Dalsgaard J, Bjerggaard K, Andersen I, Hansen TB, Kehlet H (2012) Early recovery after fast-track Oxford unicompartmental knee arthroplasty. 35 patients with minimal invasive surgery. Acta Orthop 83:41–45CrossRefPubMedPubMedCentral Munk S, Dalsgaard J, Bjerggaard K, Andersen I, Hansen TB, Kehlet H (2012) Early recovery after fast-track Oxford unicompartmental knee arthroplasty. 35 patients with minimal invasive surgery. Acta Orthop 83:41–45CrossRefPubMedPubMedCentral
12.
go back to reference Murphy TP, Brubaker SM, Mihalko WM, Saleh KJ, Mulhall KJ (2007) Review of unicompartmental knee arthroplasty in younger patients. Semin Arthroplasty 18:162–167CrossRef Murphy TP, Brubaker SM, Mihalko WM, Saleh KJ, Mulhall KJ (2007) Review of unicompartmental knee arthroplasty in younger patients. Semin Arthroplasty 18:162–167CrossRef
13.
go back to reference Nair R, Tripathy G, Deysine GR (2014) Computer navigation systems in unicompartmental knee arthroplasty: a systematic review. Am J Orthop 6:256–261 Nair R, Tripathy G, Deysine GR (2014) Computer navigation systems in unicompartmental knee arthroplasty: a systematic review. Am J Orthop 6:256–261
14.
go back to reference Noticewala MS, Geller JA, Lee JH, Macaulay W (2012) Unicompartmental knee arthroplasty relieves pain and improves function more than total knee arthroplasty. J Arthroplasty 27:99–105CrossRefPubMed Noticewala MS, Geller JA, Lee JH, Macaulay W (2012) Unicompartmental knee arthroplasty relieves pain and improves function more than total knee arthroplasty. J Arthroplasty 27:99–105CrossRefPubMed
15.
go back to reference Pandit H, Jenkins C, Gill HS, Barker K, Dodd CA, Murray DW (2011) Minimally invasive Oxford phase 3 unicompartmental knee replacement: results of 1,000 cases. J Bone Joint Surg Br 93:198–204CrossRefPubMed Pandit H, Jenkins C, Gill HS, Barker K, Dodd CA, Murray DW (2011) Minimally invasive Oxford phase 3 unicompartmental knee replacement: results of 1,000 cases. J Bone Joint Surg Br 93:198–204CrossRefPubMed
16.
go back to reference Pietsch M, Djahani O, Zweiger Ch, Plattner F, Radl R, Tschauner Ch, Hofmann S (2013) Custom-fit minimally invasive total knee arthroplasty: effect on blood loss and early clinical outcomes. Knee Surg Sports Traumatol Arthrosc 21(10):2234–2240CrossRefPubMed Pietsch M, Djahani O, Zweiger Ch, Plattner F, Radl R, Tschauner Ch, Hofmann S (2013) Custom-fit minimally invasive total knee arthroplasty: effect on blood loss and early clinical outcomes. Knee Surg Sports Traumatol Arthrosc 21(10):2234–2240CrossRefPubMed
17.
go back to reference Rosenberger RE, Fink C, Quirbach S, Attal R, Tecklenburg K, Hoser C (2008) The immediate effect of navigation on implant accuracy in primary mini-invasive unicompartmental knee arthroplasty. Knee Surg Sports Traumatol Arthrosc 16:1133–1140CrossRefPubMed Rosenberger RE, Fink C, Quirbach S, Attal R, Tecklenburg K, Hoser C (2008) The immediate effect of navigation on implant accuracy in primary mini-invasive unicompartmental knee arthroplasty. Knee Surg Sports Traumatol Arthrosc 16:1133–1140CrossRefPubMed
18.
go back to reference Schindler OS (2007) Minimally invasive surgery of the knee. J Perioper Pract 17:535–542PubMed Schindler OS (2007) Minimally invasive surgery of the knee. J Perioper Pract 17:535–542PubMed
19.
go back to reference Seon JK, Song EK, Park SJ, Yoon TR, Lee KB, Jung ST (2009) Comparison of minimally invasive unicompartmental knee arthroplasty with or without a navigation system. J Arthroplasty 24:351–357CrossRefPubMed Seon JK, Song EK, Park SJ, Yoon TR, Lee KB, Jung ST (2009) Comparison of minimally invasive unicompartmental knee arthroplasty with or without a navigation system. J Arthroplasty 24:351–357CrossRefPubMed
20.
go back to reference Sgaglione NA, Chen E, Bert JM, Amendola A, Bugbee WD (2010) Current strategies for nonsurgical, arthroscopic, and minimally invasive surgical treatment of knee cartilage pathology. Instr Course Lect 59:157–180PubMed Sgaglione NA, Chen E, Bert JM, Amendola A, Bugbee WD (2010) Current strategies for nonsurgical, arthroscopic, and minimally invasive surgical treatment of knee cartilage pathology. Instr Course Lect 59:157–180PubMed
21.
go back to reference van der Linden-van der Zwaag HM, Bos J, van der Heide HJ, Nelissen RG (2011) A computed tomography based study on rotational alignment accuracy of the femoral component in total knee arthroplasty using computer-assisted orthopaedic surgery. Int Orthop 35:845–850CrossRefPubMed van der Linden-van der Zwaag HM, Bos J, van der Heide HJ, Nelissen RG (2011) A computed tomography based study on rotational alignment accuracy of the femoral component in total knee arthroplasty using computer-assisted orthopaedic surgery. Int Orthop 35:845–850CrossRefPubMed
22.
go back to reference Weber P, Crispin A, Schmidutz F, Utzschneider S, Pietschmann MF, Jansson V, Müller PE (2013) Improved accuracy in computer-assisted unicondylar knee arthroplasty: a meta-analysis. Knee Surg Sports Traumatol Arthrosc 21(11):2453–2461CrossRefPubMed Weber P, Crispin A, Schmidutz F, Utzschneider S, Pietschmann MF, Jansson V, Müller PE (2013) Improved accuracy in computer-assisted unicondylar knee arthroplasty: a meta-analysis. Knee Surg Sports Traumatol Arthrosc 21(11):2453–2461CrossRefPubMed
23.
go back to reference Yang KY, Wang MC, Yeo SJ, Lo NN (2003) Minimally invasive unicondylar versus total condylar knee arthroplasty-early results of a matched-pair comparison. Singapore Med J 44:559–562PubMed Yang KY, Wang MC, Yeo SJ, Lo NN (2003) Minimally invasive unicondylar versus total condylar knee arthroplasty-early results of a matched-pair comparison. Singapore Med J 44:559–562PubMed
24.
go back to reference Zhang Z, Gu B, Zhu W, Zhu L, Li Q, Du Y (2014) Minimal invasive and computer-assisted total knee replacement compared with the minimal invasive technique: a prospective, randomized trial with short-term outcomes. Arch Orthop Trauma Surg 134(1):65–71CrossRefPubMed Zhang Z, Gu B, Zhu W, Zhu L, Li Q, Du Y (2014) Minimal invasive and computer-assisted total knee replacement compared with the minimal invasive technique: a prospective, randomized trial with short-term outcomes. Arch Orthop Trauma Surg 134(1):65–71CrossRefPubMed
Metadata
Title
Superior alignment but no difference in clinical outcome after minimally invasive computer-assisted unicompartmental knee arthroplasty (MICA-UKA)
Authors
Zhenxiang Zhang
Wei Zhu
Lixian Zhu
Yaqing Du
Publication date
01-11-2016
Publisher
Springer Berlin Heidelberg
Published in
Knee Surgery, Sports Traumatology, Arthroscopy / Issue 11/2016
Print ISSN: 0942-2056
Electronic ISSN: 1433-7347
DOI
https://doi.org/10.1007/s00167-014-3456-9

Other articles of this Issue 11/2016

Knee Surgery, Sports Traumatology, Arthroscopy 11/2016 Go to the issue