Abstract

Purpose

Inaccurate implantation rates of up to 30 % have been reported in cases using the conventional technique for implantation of a unicompartmental knee arthroplasty. Navigation should permit a more precise implantation, and several studies have investigated its role, albeit with a limited number of patients and inconsistent results. The aim of this meta-analysis was to compare risks of unsatisfactory outcomes in patients with navigated and conventional technique.

Methods

An electronic search was performed, and ten studies were eligible and included in the meta-analysis, with a total of 258 prostheses implanted with the navigated technique and 295 with the conventional one. The following items were analysed: radiological positioning of the femoral and the tibial component in the AP and lateral view, radiological analysis of the tibiofemoral mechanical axis and the difference in operating time between the two groups. Relative risks (RR) were calculated from the reported percentages of implants outside the optimal ranges defined by the manufacturers or the study groups. Natural logarithms of the relative risks were pooled by means of random effects models.

Results

For all the analysed radiological parameters, the RR of measurements outside the optimal ranges were less than 1 in the navigation group suggesting a reduction in the risk of outliers with navigation. The average operating time in the navigated group was 15.4 min (95 % CI: 10.2–20.6) longer than in the conventional group.

Conclusion

The meta-analysis shows that the use of navigation systems in UKA leads to a more precise component position. Whether the more accurate position in UKA results in a better clinical outcome or long-term survival is yet unknown. Nevertheless, as a precise implant position appears to be beneficial, the use of navigation should be recommended for UKA. The limits defined by the manufacturers for an optimal positioning are not consistent.

Level of evidence

Therapeutic study (Systematic review of Level II/III studies), Level III.
Literature
1.
go back to reference The Swedish Knee Arthroplasty Register (2010) Annual Report 2010. Wallin & Dalholm, Lund The Swedish Knee Arthroplasty Register (2010) Annual Report 2010. Wallin & Dalholm, Lund
2.
go back to reference Aldinger PR, Clarius M, Murray DW, Goodfellow JW, Breusch SJ (2004) Medial unicompartmental knee replacement using the “Oxford Uni” meniscal bearing knee. Orthopade 33:1277–1283PubMedCrossRef Aldinger PR, Clarius M, Murray DW, Goodfellow JW, Breusch SJ (2004) Medial unicompartmental knee replacement using the “Oxford Uni” meniscal bearing knee. Orthopade 33:1277–1283PubMedCrossRef
3.
go back to reference Bauwens K, Matthes G, Wich M, Gebhard F, Hanson B, Ekkernkamp A, Stengel D (2007) Navigated total knee replacement. A meta-analysis. J Bone Jt Surg Am 89:261–269CrossRef Bauwens K, Matthes G, Wich M, Gebhard F, Hanson B, Ekkernkamp A, Stengel D (2007) Navigated total knee replacement. A meta-analysis. J Bone Jt Surg Am 89:261–269CrossRef
4.
go back to reference Brin YS, Nikolaou VS, Joseph L, Zukor DJ, Antoniou J (2011) Imageless computer assisted versus conventional total knee replacement. A Bayesian meta-analysis of 23 comparative studies. Int Orthop 35:331–339PubMedCrossRef Brin YS, Nikolaou VS, Joseph L, Zukor DJ, Antoniou J (2011) Imageless computer assisted versus conventional total knee replacement. A Bayesian meta-analysis of 23 comparative studies. Int Orthop 35:331–339PubMedCrossRef
5.
go back to reference Browne JA, Cook C, Hofmann AA, Bolognesi MP (2010) Postoperative morbidity and mortality following total knee arthroplasty with computer navigation. Knee 17:152–156PubMedCrossRef Browne JA, Cook C, Hofmann AA, Bolognesi MP (2010) Postoperative morbidity and mortality following total knee arthroplasty with computer navigation. Knee 17:152–156PubMedCrossRef
6.
go back to reference Buckup K, Linke LC, Hahne V (2007) Minimally invasive implantation and computer navigation for a unicondylar knee system. Orthopedics 30:66–69PubMed Buckup K, Linke LC, Hahne V (2007) Minimally invasive implantation and computer navigation for a unicondylar knee system. Orthopedics 30:66–69PubMed
7.
go back to reference Cheng T, Zhao S, Peng X, Zhang X (2012) Does computer-assisted surgery improve postoperative leg alignment and implant positioning following total knee arthroplasty? A meta-analysis of randomized controlled trials? Knee Surg Sports Traumatol Arthrosc 20:1307–1322PubMedCrossRef Cheng T, Zhao S, Peng X, Zhang X (2012) Does computer-assisted surgery improve postoperative leg alignment and implant positioning following total knee arthroplasty? A meta-analysis of randomized controlled trials? Knee Surg Sports Traumatol Arthrosc 20:1307–1322PubMedCrossRef
8.
go back to reference Cossey AJ, Spriggins AJ (2005) The use of computer-assisted surgical navigation to prevent malalignment in unicompartmental knee arthroplasty. J Arthroplasty 20:29–34PubMedCrossRef Cossey AJ, Spriggins AJ (2005) The use of computer-assisted surgical navigation to prevent malalignment in unicompartmental knee arthroplasty. J Arthroplasty 20:29–34PubMedCrossRef
9.
go back to reference Czurda T, Fennema P, Baumgartner M, Ritschl P (2010) The association between component malalignment and post-operative pain following navigation-assisted total knee arthroplasty: results of a cohort/nested case-control study. Knee Surg Sports Traumatol Arthrosc 18:863–869PubMedCrossRef Czurda T, Fennema P, Baumgartner M, Ritschl P (2010) The association between component malalignment and post-operative pain following navigation-assisted total knee arthroplasty: results of a cohort/nested case-control study. Knee Surg Sports Traumatol Arthrosc 18:863–869PubMedCrossRef
11.
go back to reference Fu Y, Wang M, Liu Y, Fu Q (2012) Alignment outcomes in navigated total knee arthroplasty: a meta-analysis. Knee Surg Sports Traumatol Arthrosc 20:1075–1082PubMedCrossRef Fu Y, Wang M, Liu Y, Fu Q (2012) Alignment outcomes in navigated total knee arthroplasty: a meta-analysis. Knee Surg Sports Traumatol Arthrosc 20:1075–1082PubMedCrossRef
12.
go back to reference Gulati A, Pandit H, Jenkins C, Chau R, Dodd CA, Murray DW (2009) The effect of leg alignment on the outcome of unicompartmental knee replacement. J Bone Jt Surg Br 91:469–474 Gulati A, Pandit H, Jenkins C, Chau R, Dodd CA, Murray DW (2009) The effect of leg alignment on the outcome of unicompartmental knee replacement. J Bone Jt Surg Br 91:469–474
13.
go back to reference Haaker RG, Wojciechowski M, Patzer P, Willburger RE, Senkal M, Engelhardt M (2006) Minimally invasive unicondylar knee replacement with computer navigation. Orthopade 35:1073–1079PubMedCrossRef Haaker RG, Wojciechowski M, Patzer P, Willburger RE, Senkal M, Engelhardt M (2006) Minimally invasive unicondylar knee replacement with computer navigation. Orthopade 35:1073–1079PubMedCrossRef
14.
go back to reference Hernigou P, Deschamps G (2004) Alignment influences wear in the knee after medial unicompartmental arthroplasty. Clin Orthop Relat Res 423:161–165PubMedCrossRef Hernigou P, Deschamps G (2004) Alignment influences wear in the knee after medial unicompartmental arthroplasty. Clin Orthop Relat Res 423:161–165PubMedCrossRef
15.
go back to reference Hernigou P, Deschamps G (2004) Posterior slope of the tibial implant and the outcome of unicompartmental knee arthroplasty. J Bone Jt Surg Am 86-A:506–511 Hernigou P, Deschamps G (2004) Posterior slope of the tibial implant and the outcome of unicompartmental knee arthroplasty. J Bone Jt Surg Am 86-A:506–511
16.
go back to reference Jadad AR, Moore RA, Carroll D, Jenkinson C, Reynolds DJ, Gavaghan DJ, McQuay HJ (1996) Assessing the quality of reports of randomized clinical trials: is blinding necessary? Control Clin Trials 17:1–12PubMedCrossRef Jadad AR, Moore RA, Carroll D, Jenkinson C, Reynolds DJ, Gavaghan DJ, McQuay HJ (1996) Assessing the quality of reports of randomized clinical trials: is blinding necessary? Control Clin Trials 17:1–12PubMedCrossRef
18.
go back to reference Jenny JY, Boeri C (2003) Unicompartmental knee prosthesis implantation with a non-image-based navigation system: rationale, technique, case-control comparative study with a conventional instrumented implantation. Knee Surg Sports Traumatol Arthrosc 11:40–45PubMed Jenny JY, Boeri C (2003) Unicompartmental knee prosthesis implantation with a non-image-based navigation system: rationale, technique, case-control comparative study with a conventional instrumented implantation. Knee Surg Sports Traumatol Arthrosc 11:40–45PubMed
19.
go back to reference Jenny JY, Ciobanu E, Boeri C (2007) The rationale for navigated minimally invasive unicompartmental knee replacement. Clin Orthop Relat Res 463:58–62PubMed Jenny JY, Ciobanu E, Boeri C (2007) The rationale for navigated minimally invasive unicompartmental knee replacement. Clin Orthop Relat Res 463:58–62PubMed
20.
go back to reference Jenny JY, Muller PE, Weyer R, John M, Weber P, Ciobanu E, Schmitz A, Bacher T, Neumann W, Jansson V (2006) Navigated minimally invasive unicompartmental knee arthroplasty. Orthopedics 29:S117–S121PubMed Jenny JY, Muller PE, Weyer R, John M, Weber P, Ciobanu E, Schmitz A, Bacher T, Neumann W, Jansson V (2006) Navigated minimally invasive unicompartmental knee arthroplasty. Orthopedics 29:S117–S121PubMed
21.
go back to reference Jung KA, Kim SJ, Lee SC, Hwang SH, Ahn NK (2010) Accuracy of implantation during computer-assisted minimally invasive Oxford unicompartmental knee arthroplasty: a comparison with a conventional instrumented technique. Knee 17:387–391PubMedCrossRef Jung KA, Kim SJ, Lee SC, Hwang SH, Ahn NK (2010) Accuracy of implantation during computer-assisted minimally invasive Oxford unicompartmental knee arthroplasty: a comparison with a conventional instrumented technique. Knee 17:387–391PubMedCrossRef
22.
go back to reference Keene G, Simpson D, Kalairajah Y (2006) Limb alignment in computer-assisted minimally-invasive unicompartmental knee replacement. J Bone Jt Surg Br 88:44–48 Keene G, Simpson D, Kalairajah Y (2006) Limb alignment in computer-assisted minimally-invasive unicompartmental knee replacement. J Bone Jt Surg Br 88:44–48
23.
go back to reference Kennedy WR, White RP (1987) Unicompartmental arthroplasty of the knee. Postoperative alignment and its influence on overall results. Clin Orthop Relat Res 221:278–285PubMed Kennedy WR, White RP (1987) Unicompartmental arthroplasty of the knee. Postoperative alignment and its influence on overall results. Clin Orthop Relat Res 221:278–285PubMed
24.
go back to reference Konyves A, Willis-Owen CA, Spriggins AJ (2010) The long-term benefit of computer-assisted surgical navigation in unicompartmental knee arthroplasty. J Orthop Surg Res 5:94PubMedCrossRef Konyves A, Willis-Owen CA, Spriggins AJ (2010) The long-term benefit of computer-assisted surgical navigation in unicompartmental knee arthroplasty. J Orthop Surg Res 5:94PubMedCrossRef
25.
go back to reference Labek G, Sekyra K, Pawelka W, Janda W, Stockl B (2011) Outcome and reproducibility of data concerning the Oxford unicompartmental knee arthroplasty: a structured literature review including arthroplasty registry data. Acta Orthop 82:131–135PubMedCrossRef Labek G, Sekyra K, Pawelka W, Janda W, Stockl B (2011) Outcome and reproducibility of data concerning the Oxford unicompartmental knee arthroplasty: a structured literature review including arthroplasty registry data. Acta Orthop 82:131–135PubMedCrossRef
26.
go back to reference Lim MH, Tallay A, Bartlett J (2009) Comparative study of the use of computer assisted navigation system for axial correction in medial unicompartmental knee arthroplasty. Knee Surg Sports Traumatol Arthrosc 17:341–346PubMedCrossRef Lim MH, Tallay A, Bartlett J (2009) Comparative study of the use of computer assisted navigation system for axial correction in medial unicompartmental knee arthroplasty. Knee Surg Sports Traumatol Arthrosc 17:341–346PubMedCrossRef
27.
go back to reference Lyons MC, Macdonald SJ, Somerville LE, Naudie DD, McCalden RW (2012) Unicompartmental versus total knee arthroplasty database analysis: is there a winner? Clin Orthop Relat Res 470:84–90PubMedCrossRef Lyons MC, Macdonald SJ, Somerville LE, Naudie DD, McCalden RW (2012) Unicompartmental versus total knee arthroplasty database analysis: is there a winner? Clin Orthop Relat Res 470:84–90PubMedCrossRef
28.
go back to reference Ma B, Rudan J, Chakravertty R, Grant H (2009) Computer-assisted FluoroGuide navigation of unicompartmental knee arthroplasty. Can J Surg 52:379–385PubMed Ma B, Rudan J, Chakravertty R, Grant H (2009) Computer-assisted FluoroGuide navigation of unicompartmental knee arthroplasty. Can J Surg 52:379–385PubMed
29.
go back to reference Mayman DJ, Rudan J, Watson D, Ellis R (2004) Computer-enhanced insertion of the Oxford unicompartmental arthroplasty: a fluoroguide technique. Comput Aided Surg 9:81–85PubMed Mayman DJ, Rudan J, Watson D, Ellis R (2004) Computer-enhanced insertion of the Oxford unicompartmental arthroplasty: a fluoroguide technique. Comput Aided Surg 9:81–85PubMed
30.
go back to reference Mullaji AB, Shetty GM, Kanna R (2011) Postoperative limb alignment and its determinants after minimally invasive Oxford medial unicompartmental knee arthroplasty. J Arthroplasty 26:919–925PubMedCrossRef Mullaji AB, Shetty GM, Kanna R (2011) Postoperative limb alignment and its determinants after minimally invasive Oxford medial unicompartmental knee arthroplasty. J Arthroplasty 26:919–925PubMedCrossRef
31.
go back to reference Muller PE, Pellengahr C, Witt M, Kircher J, Refior HJ, Jansson V (2004) Influence of minimally invasive surgery on implant positioning and the functional outcome for medial unicompartmental knee arthroplasty. J Arthroplasty 19:296–301PubMedCrossRef Muller PE, Pellengahr C, Witt M, Kircher J, Refior HJ, Jansson V (2004) Influence of minimally invasive surgery on implant positioning and the functional outcome for medial unicompartmental knee arthroplasty. J Arthroplasty 19:296–301PubMedCrossRef
32.
go back to reference Pandit H, Jenkins C, Barker K, Dodd CA, Murray DW (2006) The Oxford medial unicompartmental knee replacement using a minimally-invasive approach. J Bone Jt Surg Br 88:54–60 Pandit H, Jenkins C, Barker K, Dodd CA, Murray DW (2006) The Oxford medial unicompartmental knee replacement using a minimally-invasive approach. J Bone Jt Surg Br 88:54–60
33.
go back to reference Perlick L, Bathis H, Tingart M, Perlick C, Luring C, Grifka J (2004) Minimally invasive unicompartmental knee replacement with a nonimage-based navigation system. Int Orthop 28:193–197PubMedCrossRef Perlick L, Bathis H, Tingart M, Perlick C, Luring C, Grifka J (2004) Minimally invasive unicompartmental knee replacement with a nonimage-based navigation system. Int Orthop 28:193–197PubMedCrossRef
34.
go back to reference Price AJ, Svard U (2011) A second decade lifetable survival analysis of the Oxford unicompartmental knee arthroplasty. Clin Orthop Relat Res 469:174–179PubMedCrossRef Price AJ, Svard U (2011) A second decade lifetable survival analysis of the Oxford unicompartmental knee arthroplasty. Clin Orthop Relat Res 469:174–179PubMedCrossRef
35.
go back to reference Rosenberger RE, Fink C, Quirbach S, Attal R, Tecklenburg K, Hoser C (2008) The immediate effect of navigation on implant accuracy in primary mini-invasive unicompartmental knee arthroplasty. Knee Surg Sports Traumatol Arthrosc 16:1133–1140PubMedCrossRef Rosenberger RE, Fink C, Quirbach S, Attal R, Tecklenburg K, Hoser C (2008) The immediate effect of navigation on implant accuracy in primary mini-invasive unicompartmental knee arthroplasty. Knee Surg Sports Traumatol Arthrosc 16:1133–1140PubMedCrossRef
36.
go back to reference Seon JK, Song EK, Park SJ, Yoon TR, Lee KB, Jung ST (2009) Comparison of minimally invasive unicompartmental knee arthroplasty with or without a navigation system. J Arthroplasty 24:351–357PubMedCrossRef Seon JK, Song EK, Park SJ, Yoon TR, Lee KB, Jung ST (2009) Comparison of minimally invasive unicompartmental knee arthroplasty with or without a navigation system. J Arthroplasty 24:351–357PubMedCrossRef
37.
go back to reference Voss F, Sheinkop MB, Galante JO, Barden RM, Rosenberg AG (1995) Miller-Galante unicompartmental knee arthroplasty at 2- to 5-year follow-up evaluations. J Arthroplasty 10:764–771PubMedCrossRef Voss F, Sheinkop MB, Galante JO, Barden RM, Rosenberg AG (1995) Miller-Galante unicompartmental knee arthroplasty at 2- to 5-year follow-up evaluations. J Arthroplasty 10:764–771PubMedCrossRef
38.
go back to reference Weber P, Schroder C, Utzschneider S, Schmidutz F, Jansson V, Muller PE (2012) Does increased tibial slope reduce the wear rate of unicompartmental knee prostheses? An in vitro investigation. Orthopade 41:298–302PubMedCrossRef Weber P, Schroder C, Utzschneider S, Schmidutz F, Jansson V, Muller PE (2012) Does increased tibial slope reduce the wear rate of unicompartmental knee prostheses? An in vitro investigation. Orthopade 41:298–302PubMedCrossRef
39.
go back to reference Weber P, Utzschneider S, Sadoghi P, Pietschmann MF, Ficklscherer A, Jansson V, Muller PE (2012) Navigation in minimally invasive unicompartmental knee arthroplasty has no advantage in comparison to a conventional minimally invasive implantation. Arch Orthop Trauma Surg 132:281–288PubMedCrossRef Weber P, Utzschneider S, Sadoghi P, Pietschmann MF, Ficklscherer A, Jansson V, Muller PE (2012) Navigation in minimally invasive unicompartmental knee arthroplasty has no advantage in comparison to a conventional minimally invasive implantation. Arch Orthop Trauma Surg 132:281–288PubMedCrossRef
40.
go back to reference Xie C, Liu K, Xiao L, Tang R (2012) Clinical outcomes after computer-assisted versus conventional total knee arthroplasty. Orthopedics 35:e647–e653PubMedCrossRef Xie C, Liu K, Xiao L, Tang R (2012) Clinical outcomes after computer-assisted versus conventional total knee arthroplasty. Orthopedics 35:e647–e653PubMedCrossRef
Metadata
Title
Improved accuracy in computer-assisted unicondylar knee arthroplasty: a meta-analysis
Authors
Patrick Weber
Alexander Crispin
Florian Schmidutz
Sandra Utzschneider
Matthias F. Pietschmann
Volkmar Jansson
Peter E. Müller
Publication date
01-11-2013
Publisher
Springer Berlin Heidelberg
Published in
Knee Surgery, Sports Traumatology, Arthroscopy / Issue 11/2013
Print ISSN: 0942-2056
Electronic ISSN: 1433-7347
DOI
https://doi.org/10.1007/s00167-013-2370-x

Other articles of this Issue 11/2013

Knee Surgery, Sports Traumatology, Arthroscopy 11/2013 Go to the issue