Skip to main content
Top
Published in: Knee Surgery, Sports Traumatology, Arthroscopy 2/2012

01-02-2012 | Knee

The fixation strength of tibial PCL press-fit reconstructions

Authors: M. Ettinger, T. Wehrhahn, M. Petri, E. Liodakis, G. Olender, U.-V. Albrecht, C. Hurschler, C. Krettek, M. Jagodzinski

Published in: Knee Surgery, Sports Traumatology, Arthroscopy | Issue 2/2012

Login to get access

Abstract

Purpose

A secure tibial press-fit technique in posterior cruciate ligament reconstructions is an interesting technique because no hardware is necessary. For anterior cruciate ligament (ACL) reconstruction, a few press-fit procedures have been published. Up to the present point, no biomechanical data exist for a tibial press-fit posterior cruciate ligament (PCL) reconstruction. The purpose of this study was to characterize a press-fit procedure for PCL reconstruction that is biomechanically equivalent to an interference screw fixation.

Methods

Quadriceps and hamstring tendons of 20 human cadavers (age: 49.2 ± 18.5 years) were used. A press-fit fixation with a knot in the semitendinosus tendon (K) and a quadriceps tendon bone block graft (Q) were compared to an interference screw fixation (I) in 30 porcine femora. In each group, nine constructs were cyclically stretched and then loaded until failure. Maximum load to failure, stiffness, and elongation during failure testing and cyclical loading were investigated.

Results

The maximum load to failure was 518 ± 157 N (387–650 N) for the (K) group, 558 ± 119 N (466–650 N) for the (I) group, and 620 ± 102 N (541–699 N) for the (Q) group. The stiffness was 55 ± 27 N/mm (18–89 N/mm) for the (K) group, 117 ± 62 N/mm (69–165 N/mm) for the (I) group, and 65 ± 21 N/mm (49–82 N/mm) for the (Q) group. The stiffness of the (I) group was significantly larger (P = 0.01). The elongation during cyclical loading was significantly larger for all groups from the 1st to the 5th cycle compared to the elongation in between the 5th to the 20th cycle (P < 0.03).

Conclusion

All techniques exhibited larger elongation during initial loading. Load to failure and stiffness was significantly different between the fixations. The Q fixation showed equal biomechanical properties compared to a pure tendon fixation (I) with an interference screw.
All three fixation techniques that were investigated exhibit comparable biomechanical properties. Preconditioning of the constructs is critical. Clinical trials have to investigate the biological effectiveness of these fixation techniques.
Literature
1.
go back to reference Amis AA, Gupte CM, Bull AMJ, Edwards A (2006) Anatomy of the posterior cruciate ligament and the meniscofemoral ligaments. Knee Surg Sports Traumatol Arthrosc 14(3):257–263PubMedCrossRef Amis AA, Gupte CM, Bull AMJ, Edwards A (2006) Anatomy of the posterior cruciate ligament and the meniscofemoral ligaments. Knee Surg Sports Traumatol Arthrosc 14(3):257–263PubMedCrossRef
2.
go back to reference Aune AK, Ekeland A, Cawley PW (1998) Interference screw fixation of hamstring vs. patellar tendon grafts for anterior cruciate ligament reconstruction. Knee Surg Sports Traumatol Arthrosc 6(2):99–102PubMedCrossRef Aune AK, Ekeland A, Cawley PW (1998) Interference screw fixation of hamstring vs. patellar tendon grafts for anterior cruciate ligament reconstruction. Knee Surg Sports Traumatol Arthrosc 6(2):99–102PubMedCrossRef
3.
go back to reference Bergfeld JA, Graham SM, Parker RD, Valdevit ADC, Kambic HE (2005) A biomechanical comparison of posterior cruciate ligament reconstructions using single-and double-bundle tibial inlay techniques. Am J Sports Med 33(7):976–983PubMedCrossRef Bergfeld JA, Graham SM, Parker RD, Valdevit ADC, Kambic HE (2005) A biomechanical comparison of posterior cruciate ligament reconstructions using single-and double-bundle tibial inlay techniques. Am J Sports Med 33(7):976–983PubMedCrossRef
4.
go back to reference Bergfeld JA, McAllister DR, Parker RD, Valdevit ADC, Kambic HE (2001) A biomechanical comparison of posterior cruciate ligament reconstruction techniques. Am J Sports Med 29(2):129–136PubMed Bergfeld JA, McAllister DR, Parker RD, Valdevit ADC, Kambic HE (2001) A biomechanical comparison of posterior cruciate ligament reconstruction techniques. Am J Sports Med 29(2):129–136PubMed
5.
go back to reference Brand J (2000) Biomechanical comparison of quadriceps tendon fixation with patellar tendon bone plug interference fixation in cruciate ligament reconstruction. Arthroscopy 16(8):805–812PubMedCrossRef Brand J (2000) Biomechanical comparison of quadriceps tendon fixation with patellar tendon bone plug interference fixation in cruciate ligament reconstruction. Arthroscopy 16(8):805–812PubMedCrossRef
6.
go back to reference Brown CH Jr, Steiner ME, Carson EW (1993) The use of hamstring tendons for anterior cruciate ligament reconstruction. Technique and results. Clin Sports Med 12(4):723–756PubMed Brown CH Jr, Steiner ME, Carson EW (1993) The use of hamstring tendons for anterior cruciate ligament reconstruction. Technique and results. Clin Sports Med 12(4):723–756PubMed
7.
go back to reference Caborn DNM, Urban WP (1997) Biomechanical comparison between BioScrew and titanium alloy interference screws for bone-patellar tendon–bone graft fixation in anterior cruciate ligament reconstruction. Arthroscopy 13(2):229–232PubMedCrossRef Caborn DNM, Urban WP (1997) Biomechanical comparison between BioScrew and titanium alloy interference screws for bone-patellar tendon–bone graft fixation in anterior cruciate ligament reconstruction. Arthroscopy 13(2):229–232PubMedCrossRef
8.
go back to reference Campbell RB, Torrie A, Hecker A, Sekiya JK (2007) Comparison of tibial graft fixation between simulated arthroscopic and open inlay techniques for posterior cruciate ligament reconstruction. Am J Sports Med 35(10):1731–1738PubMedCrossRef Campbell RB, Torrie A, Hecker A, Sekiya JK (2007) Comparison of tibial graft fixation between simulated arthroscopic and open inlay techniques for posterior cruciate ligament reconstruction. Am J Sports Med 35(10):1731–1738PubMedCrossRef
9.
go back to reference Chen CH, Chen WJ, Shih CH, Chou SW (2004) Arthroscopic posterior cruciate ligament reconstruction with quadriceps tendon autograft: minimal 3 years follow-up. Am J Sports Med 32(2):361–368PubMedCrossRef Chen CH, Chen WJ, Shih CH, Chou SW (2004) Arthroscopic posterior cruciate ligament reconstruction with quadriceps tendon autograft: minimal 3 years follow-up. Am J Sports Med 32(2):361–368PubMedCrossRef
10.
go back to reference Chen CH, Chou SW, Chen WJ, Shih CH (2004) Fixation strength of three different graft types used in posterior cruciate ligament reconstruction. Knee Surg Sports Traumatol Arthrosc 12(5):371–375PubMed Chen CH, Chou SW, Chen WJ, Shih CH (2004) Fixation strength of three different graft types used in posterior cruciate ligament reconstruction. Knee Surg Sports Traumatol Arthrosc 12(5):371–375PubMed
11.
go back to reference Drogset JO, Grøntvedt T, Myhr G (2006) Magnetic resonance imaging analysis of bioabsorbable interference screws used for fixation of boneñpatellar tendonñbone autografts in endoscopic reconstruction of the anterior cruciate ligament. Am J Sports Med 34(7):1164–1169PubMedCrossRef Drogset JO, Grøntvedt T, Myhr G (2006) Magnetic resonance imaging analysis of bioabsorbable interference screws used for fixation of boneñpatellar tendonñbone autografts in endoscopic reconstruction of the anterior cruciate ligament. Am J Sports Med 34(7):1164–1169PubMedCrossRef
12.
go back to reference Ettinger M, Haasper C, Hankemeier S, Hurschler C, Breitmeier D, Krettek C, Jagodzinski M (2011) Biomechanical characterization of double-bundle femoral press-fit fixation techniques. Knee Surg Sports Traumatol Arthrosc 19(3):363–371PubMedCrossRef Ettinger M, Haasper C, Hankemeier S, Hurschler C, Breitmeier D, Krettek C, Jagodzinski M (2011) Biomechanical characterization of double-bundle femoral press-fit fixation techniques. Knee Surg Sports Traumatol Arthrosc 19(3):363–371PubMedCrossRef
13.
go back to reference Frank CB, Jackson DW (1997) Current concepts review-the science of reconstruction of the anterior cruciate ligament. J Bone Joint Surg 79(10):1556PubMed Frank CB, Jackson DW (1997) Current concepts review-the science of reconstruction of the anterior cruciate ligament. J Bone Joint Surg 79(10):1556PubMed
14.
go back to reference Gupta A, Lattermann C, Busam M, Riff A, Bach BR, Wang VM (2009) Biomechanical evaluation of bioabsorbable versus metallic screws for posterior cruciate ligament inlay graft fixation. Am J Sports Med 37(4):748–753PubMedCrossRef Gupta A, Lattermann C, Busam M, Riff A, Bach BR, Wang VM (2009) Biomechanical evaluation of bioabsorbable versus metallic screws for posterior cruciate ligament inlay graft fixation. Am J Sports Med 37(4):748–753PubMedCrossRef
15.
go back to reference Hiraga Y, Ishibashi Y, Tsuda E, Toh HTS (2006) Biomechanical comparison of posterior cruciate ligament reconstruction techniques using cyclic loading tests. Knee Surg Sports Traumatol Arthrosc 14(1):13–19PubMedCrossRef Hiraga Y, Ishibashi Y, Tsuda E, Toh HTS (2006) Biomechanical comparison of posterior cruciate ligament reconstruction techniques using cyclic loading tests. Knee Surg Sports Traumatol Arthrosc 14(1):13–19PubMedCrossRef
16.
go back to reference Höher J, Scheffler S, Weiler A (2003) Graft choice and graft fixation in PCL reconstruction. Knee Surg Sports Traumatol Arthrosc 11(5):297–306PubMedCrossRef Höher J, Scheffler S, Weiler A (2003) Graft choice and graft fixation in PCL reconstruction. Knee Surg Sports Traumatol Arthrosc 11(5):297–306PubMedCrossRef
17.
go back to reference Jagodzinski M, Behfar V, Hurschler C, Albrecht K, Krettek C, Bosch U (2004) Femoral press-fit fixation of the hamstring tendons for anterior cruciate ligament reconstruction. Am J Sports Med 32(7):1723–1730PubMedCrossRef Jagodzinski M, Behfar V, Hurschler C, Albrecht K, Krettek C, Bosch U (2004) Femoral press-fit fixation of the hamstring tendons for anterior cruciate ligament reconstruction. Am J Sports Med 32(7):1723–1730PubMedCrossRef
18.
go back to reference Jagodzinski M, Scheunemann K, Knobloch K, Albrecht K, Krettek C, Hurschler C, Zeichen J (2006) Tibial press-fit fixation of the hamstring tendons for ACL-reconstruction. Knee Surg Sports Traumatol Arthrosc 14(12):1281–1287PubMedCrossRef Jagodzinski M, Scheunemann K, Knobloch K, Albrecht K, Krettek C, Hurschler C, Zeichen J (2006) Tibial press-fit fixation of the hamstring tendons for ACL-reconstruction. Knee Surg Sports Traumatol Arthrosc 14(12):1281–1287PubMedCrossRef
19.
go back to reference Kocabey Y, Klein S, Nyland J, Caborn D (2004) Tibial fixation comparison of semitendinosus-bone composite allografts fixed with bioabsorbable screws and bone-patella tendon-bone grafts fixed with titanium screws. Knee Surg Sports Traumatol Arthrosc 12(2):88–93PubMedCrossRef Kocabey Y, Klein S, Nyland J, Caborn D (2004) Tibial fixation comparison of semitendinosus-bone composite allografts fixed with bioabsorbable screws and bone-patella tendon-bone grafts fixed with titanium screws. Knee Surg Sports Traumatol Arthrosc 12(2):88–93PubMedCrossRef
20.
go back to reference Kousa P, Järvinen TLN, Vihavainen M, Kannus P, Järvinen M (2003) The fixation strength of six hamstring tendon graft fixation devices in anterior cruciate ligament reconstruction part 1: femoral site. Am J Sports Med 31(2):174–181PubMed Kousa P, Järvinen TLN, Vihavainen M, Kannus P, Järvinen M (2003) The fixation strength of six hamstring tendon graft fixation devices in anterior cruciate ligament reconstruction part 1: femoral site. Am J Sports Med 31(2):174–181PubMed
21.
go back to reference Krudwig WK (1996) Functional anatomy of the posterior cruciate ligament. Unfallchirurgie 22(2):49–56PubMed Krudwig WK (1996) Functional anatomy of the posterior cruciate ligament. Unfallchirurgie 22(2):49–56PubMed
22.
go back to reference Kurosaka M, Yoshiya S, Andrish JT (1987) A biomechanical comparison of different surgical techniques of graft fixation in anterior cruciate ligament reconstruction. Am J Sports Med 15(3):225–229PubMedCrossRef Kurosaka M, Yoshiya S, Andrish JT (1987) A biomechanical comparison of different surgical techniques of graft fixation in anterior cruciate ligament reconstruction. Am J Sports Med 15(3):225–229PubMedCrossRef
23.
go back to reference Lee YS, Wang JH, Bae JH, Lim HC, Park JH, Ahn JH, Bae TS, Lim BO (2009) Biomechanical evaluation of cross-pin versus interference screw tibial fixation using a soft-tissue graft during transtibial posterior cruciate ligament reconstruction. Arthroscopy 25(9):989–995PubMedCrossRef Lee YS, Wang JH, Bae JH, Lim HC, Park JH, Ahn JH, Bae TS, Lim BO (2009) Biomechanical evaluation of cross-pin versus interference screw tibial fixation using a soft-tissue graft during transtibial posterior cruciate ligament reconstruction. Arthroscopy 25(9):989–995PubMedCrossRef
24.
go back to reference Lehmann AK, Osada N, Zantop T, Raschke MJ, Petersen W (2009) Femoral bridge stability in double-bundle ACL reconstruction: impact of bridge width and different fixation techniques on the structural properties of the graft/femur complex. Arch Orthop Trauma Surg 129(8):1127–1132PubMedCrossRef Lehmann AK, Osada N, Zantop T, Raschke MJ, Petersen W (2009) Femoral bridge stability in double-bundle ACL reconstruction: impact of bridge width and different fixation techniques on the structural properties of the graft/femur complex. Arch Orthop Trauma Surg 129(8):1127–1132PubMedCrossRef
25.
go back to reference Lim HC, Bae JH, Wang JH, Bae TS, Kim CW, Hwang JH, Yoon JY (2009) The biomechanical performance of bone block and soft-tissue posterior cruciate ligament graft fixation with interference screw and cross-pin techniques. Arthroscopy 25(3):250–256PubMedCrossRef Lim HC, Bae JH, Wang JH, Bae TS, Kim CW, Hwang JH, Yoon JY (2009) The biomechanical performance of bone block and soft-tissue posterior cruciate ligament graft fixation with interference screw and cross-pin techniques. Arthroscopy 25(3):250–256PubMedCrossRef
26.
go back to reference Lobenhoffer P (1999) Chronic instability after posterior cruciate ligament injury. Tactics, techniques, and results. Unfallchirurg 102(11):824–838PubMedCrossRef Lobenhoffer P (1999) Chronic instability after posterior cruciate ligament injury. Tactics, techniques, and results. Unfallchirurg 102(11):824–838PubMedCrossRef
27.
go back to reference Margheritini F, Mauro CS, Rihn JA, Stabile KJ, Woo SLY, Harner CD (2004) Biomechanical comparison of tibial inlay versus transtibial techniques for posterior cruciate ligament reconstruction. Am J Sports Med 32(3):587–593PubMedCrossRef Margheritini F, Mauro CS, Rihn JA, Stabile KJ, Woo SLY, Harner CD (2004) Biomechanical comparison of tibial inlay versus transtibial techniques for posterior cruciate ligament reconstruction. Am J Sports Med 32(3):587–593PubMedCrossRef
28.
go back to reference Monaco E, Labianca L, Speranza A, AgrÚ AM, Camillieri G, DíArrigo C, Ferretti A (2010) Biomechanical evaluation of different anterior cruciate ligament fixation techniques for hamstring graft. J Orthop sci 15(1):125–131PubMedCrossRef Monaco E, Labianca L, Speranza A, AgrÚ AM, Camillieri G, DíArrigo C, Ferretti A (2010) Biomechanical evaluation of different anterior cruciate ligament fixation techniques for hamstring graft. J Orthop sci 15(1):125–131PubMedCrossRef
29.
go back to reference Morrison JB (1970) The mechanics of the knee joint in relation to normal walking. J Biomechanic 3(1):51–61CrossRef Morrison JB (1970) The mechanics of the knee joint in relation to normal walking. J Biomechanic 3(1):51–61CrossRef
30.
go back to reference Nagano M, Yoshiya S, Kuroda R, Kurosaka M, Mizuno K (1997) Remodelling and healing process of bone-patellar tendon-bone graft in a bone tunnel: A histological study in dogs. Trans Orthop Res Soc 22:78 Nagano M, Yoshiya S, Kuroda R, Kurosaka M, Mizuno K (1997) Remodelling and healing process of bone-patellar tendon-bone graft in a bone tunnel: A histological study in dogs. Trans Orthop Res Soc 22:78
31.
go back to reference Noyes FR, Barber-Westin SD (2001) Revision anterior cruciate surgery with use of bone-patellar tendon-bone autogenous grafts. J Bone Joint Surg 83(8):1131–1143PubMed Noyes FR, Barber-Westin SD (2001) Revision anterior cruciate surgery with use of bone-patellar tendon-bone autogenous grafts. J Bone Joint Surg 83(8):1131–1143PubMed
32.
go back to reference Nurmi JT, Sievänen H, Kannus P, Järvinen M, Järvinen TLN (2004) Porcine tibia is a poor substitute for human cadaver tibia for evaluating interference screw fixation. Am J Sports Med 32(3):765–771PubMedCrossRef Nurmi JT, Sievänen H, Kannus P, Järvinen M, Järvinen TLN (2004) Porcine tibia is a poor substitute for human cadaver tibia for evaluating interference screw fixation. Am J Sports Med 32(3):765–771PubMedCrossRef
33.
go back to reference Prodromos CC, Hecker A, Joyce B, Finkle S, Shi K (2009) Elongation of simulated whipstitch post anterior cruciate ligament reconstruction tibial fixation after cyclic loading. Knee Surg Sports Traumatol Arthrosc 17(8):914–919PubMedCrossRef Prodromos CC, Hecker A, Joyce B, Finkle S, Shi K (2009) Elongation of simulated whipstitch post anterior cruciate ligament reconstruction tibial fixation after cyclic loading. Knee Surg Sports Traumatol Arthrosc 17(8):914–919PubMedCrossRef
34.
go back to reference Ruberte Thiele RA, Campbell RB, Amendola A, Sekiya JK (2010) Biomechanical comparison of figure-of-8 versus cylindrical tibial inlay constructs for arthroscopic posterior cruciate ligament reconstruction. Arthroscopy 26(7):977–983PubMedCrossRef Ruberte Thiele RA, Campbell RB, Amendola A, Sekiya JK (2010) Biomechanical comparison of figure-of-8 versus cylindrical tibial inlay constructs for arthroscopic posterior cruciate ligament reconstruction. Arthroscopy 26(7):977–983PubMedCrossRef
35.
go back to reference Seil R, Rupp S, Krauss PW, Benz A, Kohn DM (1998) Comparison of initial fixation strength between biodegradable and metallic interference screws and a press-fit fixation technique in a porcine model. Am J Sports Med 26(6):815PubMed Seil R, Rupp S, Krauss PW, Benz A, Kohn DM (1998) Comparison of initial fixation strength between biodegradable and metallic interference screws and a press-fit fixation technique in a porcine model. Am J Sports Med 26(6):815PubMed
36.
go back to reference Seon JK, Song EK (2006) Reconstruction of isolated posterior cruciate ligament injuries: a clinical comparison of the transtibial and tibial inlay techniques. Arthroscopy 22(1):27–32PubMedCrossRef Seon JK, Song EK (2006) Reconstruction of isolated posterior cruciate ligament injuries: a clinical comparison of the transtibial and tibial inlay techniques. Arthroscopy 22(1):27–32PubMedCrossRef
37.
go back to reference Shearn JT, Grood ES, Noyes FR, Levy MS (2006) One-and two-strand posterior cruciate ligament reconstructions: cyclic fatigue testing. J Orthop Res 23(4):958–963CrossRef Shearn JT, Grood ES, Noyes FR, Levy MS (2006) One-and two-strand posterior cruciate ligament reconstructions: cyclic fatigue testing. J Orthop Res 23(4):958–963CrossRef
38.
go back to reference Steiner ME, Hecker AT, Brown CH, Hayes WC (1994) Anterior cruciate ligament graft fixation. Am J Sports Med 22(2):240–246PubMedCrossRef Steiner ME, Hecker AT, Brown CH, Hayes WC (1994) Anterior cruciate ligament graft fixation. Am J Sports Med 22(2):240–246PubMedCrossRef
39.
go back to reference Strobel MJ, Weiler A, Eichhorn HJ (2000) Diagnosis and therapy of fresh and chronic posterior cruciate ligament lesions. Chirurg 71(9):1066PubMedCrossRef Strobel MJ, Weiler A, Eichhorn HJ (2000) Diagnosis and therapy of fresh and chronic posterior cruciate ligament lesions. Chirurg 71(9):1066PubMedCrossRef
40.
go back to reference Weiler A, Hoffmann RF, Stähelin AC, Bail HJ, Siepe CJ, Südkamp NP (1998) Hamstring tendon fixation using interference screws: a biomechanical study in calf tibial bone. Arthroscopy 14(1):29–37PubMedCrossRef Weiler A, Hoffmann RF, Stähelin AC, Bail HJ, Siepe CJ, Südkamp NP (1998) Hamstring tendon fixation using interference screws: a biomechanical study in calf tibial bone. Arthroscopy 14(1):29–37PubMedCrossRef
41.
go back to reference Weiler A, Hoffmann RFG, Stähelin AC, Helling HJ, Südkamp NP (2000) Biodegradable implants in sports medicine: the biological base. Arthroscopy 16(3):305–321PubMedCrossRef Weiler A, Hoffmann RFG, Stähelin AC, Helling HJ, Südkamp NP (2000) Biodegradable implants in sports medicine: the biological base. Arthroscopy 16(3):305–321PubMedCrossRef
Metadata
Title
The fixation strength of tibial PCL press-fit reconstructions
Authors
M. Ettinger
T. Wehrhahn
M. Petri
E. Liodakis
G. Olender
U.-V. Albrecht
C. Hurschler
C. Krettek
M. Jagodzinski
Publication date
01-02-2012
Publisher
Springer-Verlag
Published in
Knee Surgery, Sports Traumatology, Arthroscopy / Issue 2/2012
Print ISSN: 0942-2056
Electronic ISSN: 1433-7347
DOI
https://doi.org/10.1007/s00167-011-1584-z

Other articles of this Issue 2/2012

Knee Surgery, Sports Traumatology, Arthroscopy 2/2012 Go to the issue