Skip to main content
Top
Published in: Knee Surgery, Sports Traumatology, Arthroscopy 4/2009

01-04-2009 | Knee

Computer-assisted surgery can reduce blood loss after total knee arthroplasty

Authors: Pedro Hinarejos, Mónica Corrales, Antonia Matamalas, Elvira Bisbe, Enric Cáceres

Published in: Knee Surgery, Sports Traumatology, Arthroscopy | Issue 4/2009

Login to get access

Abstract

The aim of this study was to compare blood loss and transfusion requirements in patients undergoing computer-assisted total knee arthroplasty (TKA) and patients operated with conventional instrumentation with intra-medullar guides. A prospective randomized study of 87 patients undergoing a TKA assigned to conventional technique (n = 44) or computer-assisted surgery (n = 43) was conducted. All patients were operated by the same surgeon and in all cases a cemented arthroplasty and deep recovery drainage were used. Both groups were comparable in all variables except for duration of ischemia, which was 13.7 min higher in the computer-assisted group. Blood loss due to drainage was higher in the conventional technique group (613 vs. 447 ml), as was the number of patients in which blood from the blood recovery system was reinfused (53 vs. 23%). Those patients undergoing computer-assisted surgery experienced less bleeding than those operated with the conventional technique. However, hemoglobin drop and allogenic transfusion rate were not statistically different in both groups.
Literature
1.
go back to reference Alvarez JC, Santiveri FX, Ramos I, Vela E, Puig L, Escolano F (2008) Tranexamic acid reduces blood transfusión in total knee arthroplasty even when a blood conservation program is applied. Transfusion 48:519–525PubMedCrossRef Alvarez JC, Santiveri FX, Ramos I, Vela E, Puig L, Escolano F (2008) Tranexamic acid reduces blood transfusión in total knee arthroplasty even when a blood conservation program is applied. Transfusion 48:519–525PubMedCrossRef
2.
go back to reference Baldini A, Adravanti P (2008) Less invasive TKA: extramedullary femoral reference without navigation. Clin Orthop Relat Res 466:2694–2700PubMedCrossRef Baldini A, Adravanti P (2008) Less invasive TKA: extramedullary femoral reference without navigation. Clin Orthop Relat Res 466:2694–2700PubMedCrossRef
3.
go back to reference Bathis H, Shafizadeh S, Paffrath T, Simanski C, Grifka J, Luring C (2006) Are computer assisted total knee replacements more accurately placed? A meta-analysis of comparative studies. Orthopade 35:1056–1065PubMedCrossRef Bathis H, Shafizadeh S, Paffrath T, Simanski C, Grifka J, Luring C (2006) Are computer assisted total knee replacements more accurately placed? A meta-analysis of comparative studies. Orthopade 35:1056–1065PubMedCrossRef
4.
go back to reference Bauwens K, Matthes G, Wich M, Gebhard F, Hanson B, Ekkernkamp A, Stengel D (2007) Navigated total knee replacement A meta-analysis. J Bone Joint Surg Am 89:261–269PubMedCrossRef Bauwens K, Matthes G, Wich M, Gebhard F, Hanson B, Ekkernkamp A, Stengel D (2007) Navigated total knee replacement A meta-analysis. J Bone Joint Surg Am 89:261–269PubMedCrossRef
5.
go back to reference Bermejo S, García J, Sánchez S, Vallés J, Ramos I, Escolano F (2005) Is the postoperative drained blood a good monitor for estimating the total blood loss following knee arthroplasty? Eur J Anaesthesiol 22(suppl 34):A294 Bermejo S, García J, Sánchez S, Vallés J, Ramos I, Escolano F (2005) Is the postoperative drained blood a good monitor for estimating the total blood loss following knee arthroplasty? Eur J Anaesthesiol 22(suppl 34):A294
6.
go back to reference Brecher ME, Monk T, Goodnough LT (1997) A standardized method for calculating blood loss. Transfusion 37:1070–1074PubMedCrossRef Brecher ME, Monk T, Goodnough LT (1997) A standardized method for calculating blood loss. Transfusion 37:1070–1074PubMedCrossRef
7.
go back to reference Chauhan SK, Scott RG, Breidahl W, Beaver RJ (2004) Computer-assisted knee arthroplasty versus a conventional jig-based technique. A randomized, prospective trial. J Bone Joint Surg Br 86:372–377PubMedCrossRef Chauhan SK, Scott RG, Breidahl W, Beaver RJ (2004) Computer-assisted knee arthroplasty versus a conventional jig-based technique. A randomized, prospective trial. J Bone Joint Surg Br 86:372–377PubMedCrossRef
8.
go back to reference Dutton AQ, Yeo SJ, Yang KY, Lo NN, Chia KU, Chong HC (2008) Computer-assisted minimally invasive total knee arthroplasty compared with standard total knee arthroplasty. A prospective, randomized study. J Bone Joint Surg Am 90:2–9PubMedCrossRef Dutton AQ, Yeo SJ, Yang KY, Lo NN, Chia KU, Chong HC (2008) Computer-assisted minimally invasive total knee arthroplasty compared with standard total knee arthroplasty. A prospective, randomized study. J Bone Joint Surg Am 90:2–9PubMedCrossRef
9.
go back to reference Fujimoto H, Ozaki T, Asaumi K, Kato H, Nishida K, Takahara Y, Abe N, Inoue H (2003) Blood loss in patients for total knee arthroplasty. Knee Surg Sports Traumatol Arthrosc 11:149–154PubMed Fujimoto H, Ozaki T, Asaumi K, Kato H, Nishida K, Takahara Y, Abe N, Inoue H (2003) Blood loss in patients for total knee arthroplasty. Knee Surg Sports Traumatol Arthrosc 11:149–154PubMed
10.
go back to reference Ishii Y, Matsuda Y (2005) Effect of tourniquet pressure on perioperative blood loss associated with cementless total knee arthroplasty: a prospective, randomized study. J Arthroplasty 20:325–330PubMedCrossRef Ishii Y, Matsuda Y (2005) Effect of tourniquet pressure on perioperative blood loss associated with cementless total knee arthroplasty: a prospective, randomized study. J Arthroplasty 20:325–330PubMedCrossRef
11.
go back to reference Kalairajah Y, Simpson D, Cossey AJ, Verrall GM, Spriggins AJ (2005) Blood loss after total knee replacement: effects of computer-assisted surgery. J Bone Joint Surg Br 87:1480–1482PubMedCrossRef Kalairajah Y, Simpson D, Cossey AJ, Verrall GM, Spriggins AJ (2005) Blood loss after total knee replacement: effects of computer-assisted surgery. J Bone Joint Surg Br 87:1480–1482PubMedCrossRef
12.
go back to reference Kandel L, Vasili C, Kirsh G (2006) Extramedullary femoral alignment in instrumentation reduces blood loss after uncemented total knee arthroplasty. J Knee Surg 19:256–258PubMed Kandel L, Vasili C, Kirsh G (2006) Extramedullary femoral alignment in instrumentation reduces blood loss after uncemented total knee arthroplasty. J Knee Surg 19:256–258PubMed
13.
go back to reference Keating EM, Meding JB, Faris PM, Ritter MA (1998) Predictors of transfusion risk in elective knee surgery. Clin Orthop Relat Res 357:50–59PubMedCrossRef Keating EM, Meding JB, Faris PM, Ritter MA (1998) Predictors of transfusion risk in elective knee surgery. Clin Orthop Relat Res 357:50–59PubMedCrossRef
14.
go back to reference Maculé-Beneyto F, Hernández-Vaquero D, Segur-Vilalta JM, Colomina-Rodríguez R, Hinarejos-Gómez P, García-Forcada I, Seral-García B (2006) Navigation in total knee arthroplasty. A multicenter study. Int Orthop 30:536–540PubMedCrossRef Maculé-Beneyto F, Hernández-Vaquero D, Segur-Vilalta JM, Colomina-Rodríguez R, Hinarejos-Gómez P, García-Forcada I, Seral-García B (2006) Navigation in total knee arthroplasty. A multicenter study. Int Orthop 30:536–540PubMedCrossRef
15.
16.
go back to reference Matziolis G, Krocker D, Weiss U, Tohtz S, Perka C (2007) A prospective, randomized study of computer-assisted and conventional total knee arthroplasty. Three-dimensional evaluation of implant alignment and rotation. J Bone Joint Surg Am 89:236–243PubMedCrossRef Matziolis G, Krocker D, Weiss U, Tohtz S, Perka C (2007) A prospective, randomized study of computer-assisted and conventional total knee arthroplasty. Three-dimensional evaluation of implant alignment and rotation. J Bone Joint Surg Am 89:236–243PubMedCrossRef
17.
go back to reference Mercuriali F, Inghilleri G (1996) Proposal of an algorithm to help the choice of the best transfusion strategy. Curr Med Res Opin 13:465–478PubMedCrossRef Mercuriali F, Inghilleri G (1996) Proposal of an algorithm to help the choice of the best transfusion strategy. Curr Med Res Opin 13:465–478PubMedCrossRef
18.
go back to reference Prasad N, Padmanabhan V, Mullaji A (2007) Blood loss in total knee arthroplasty: an analysis of risk factors. Int Orthop 31:39–44PubMedCrossRef Prasad N, Padmanabhan V, Mullaji A (2007) Blood loss in total knee arthroplasty: an analysis of risk factors. Int Orthop 31:39–44PubMedCrossRef
19.
go back to reference Rosenberger RE, Hoser C, Quirbach S, Attal R, Hennerbichler A, Fink C (2008) Improved accuracy of component alignment with the implementation of image-free navigation in total knee arthroplasty. Knee Surg Sports Traumatol Arthrosc 16:249–257PubMedCrossRef Rosenberger RE, Hoser C, Quirbach S, Attal R, Hennerbichler A, Fink C (2008) Improved accuracy of component alignment with the implementation of image-free navigation in total knee arthroplasty. Knee Surg Sports Traumatol Arthrosc 16:249–257PubMedCrossRef
20.
go back to reference Rosencher N, Kerkkamp HE, Macheras G, Munuera LM, Menichella G, Barton DM, Cremers S, Abraham IL (2003) OSTHEO investigation orthopedic surgery transfusion hemoglobin European overview (OSTHEO) study: blood management in elective knee and hip arthroplasty in Europe. Transfusion 43:459–469PubMedCrossRef Rosencher N, Kerkkamp HE, Macheras G, Munuera LM, Menichella G, Barton DM, Cremers S, Abraham IL (2003) OSTHEO investigation orthopedic surgery transfusion hemoglobin European overview (OSTHEO) study: blood management in elective knee and hip arthroplasty in Europe. Transfusion 43:459–469PubMedCrossRef
21.
go back to reference Sehat KR, Evans R, Newman JH (2000) How much blood is really lost in total knee arthroplasty? Correct blood loss management should take hidden loss into account. Knee 7:151–155PubMedCrossRef Sehat KR, Evans R, Newman JH (2000) How much blood is really lost in total knee arthroplasty? Correct blood loss management should take hidden loss into account. Knee 7:151–155PubMedCrossRef
22.
go back to reference Sehat KR, Evans RL, Newman JH (2004) Hidden blood loss following hip and knee arthroplasty correct management of blood loss should take hidden loss into account. J Bone Joint Surg Br 86:561–565PubMed Sehat KR, Evans RL, Newman JH (2004) Hidden blood loss following hip and knee arthroplasty correct management of blood loss should take hidden loss into account. J Bone Joint Surg Br 86:561–565PubMed
23.
go back to reference Teter KE, Bregman D, Colwell CW Jr (1995) The efficacy of intramedullary femoral alignment in total knee replacement. Clin Orthop Relat Res 321:117–121PubMed Teter KE, Bregman D, Colwell CW Jr (1995) The efficacy of intramedullary femoral alignment in total knee replacement. Clin Orthop Relat Res 321:117–121PubMed
24.
go back to reference Tetro AM, Rudan JF (2001) The effects of a pneumatic tourniquet on blood loss in total knee arthroplasty. Can J Surg 44:33–38PubMed Tetro AM, Rudan JF (2001) The effects of a pneumatic tourniquet on blood loss in total knee arthroplasty. Can J Surg 44:33–38PubMed
25.
go back to reference Tingart M, Lüring C, Bäthis H, Beckmann J, Grifka J, Perlick L (2008) Computer-assisted total knee arthroplasty versus the conventional technique: how precise is navigation in clinical routine? Knee Surg Sports Traumatol Arthrosc 16:44–50PubMedCrossRef Tingart M, Lüring C, Bäthis H, Beckmann J, Grifka J, Perlick L (2008) Computer-assisted total knee arthroplasty versus the conventional technique: how precise is navigation in clinical routine? Knee Surg Sports Traumatol Arthrosc 16:44–50PubMedCrossRef
26.
go back to reference Umlas J, Foster RR, Dalal SA, O’Leary SM, Garcia L, Kruskall MS (1994) Red cell loss following orthopedic surgery. The case against postoperative blood salvage. Transfusion 34:402–406PubMedCrossRef Umlas J, Foster RR, Dalal SA, O’Leary SM, Garcia L, Kruskall MS (1994) Red cell loss following orthopedic surgery. The case against postoperative blood salvage. Transfusion 34:402–406PubMedCrossRef
27.
28.
go back to reference Zufferey P, Merquiol F, Laporte S, Decousus H, Mismetti P, Auboyer C, Samama CM, Molliex S (2006) Anesthesiology 105:873–876CrossRef Zufferey P, Merquiol F, Laporte S, Decousus H, Mismetti P, Auboyer C, Samama CM, Molliex S (2006) Anesthesiology 105:873–876CrossRef
Metadata
Title
Computer-assisted surgery can reduce blood loss after total knee arthroplasty
Authors
Pedro Hinarejos
Mónica Corrales
Antonia Matamalas
Elvira Bisbe
Enric Cáceres
Publication date
01-04-2009
Publisher
Springer-Verlag
Published in
Knee Surgery, Sports Traumatology, Arthroscopy / Issue 4/2009
Print ISSN: 0942-2056
Electronic ISSN: 1433-7347
DOI
https://doi.org/10.1007/s00167-008-0683-y

Other articles of this Issue 4/2009

Knee Surgery, Sports Traumatology, Arthroscopy 4/2009 Go to the issue