Skip to main content
Top
Published in: Clinical Orthopaedics and Related Research® 11/2008

01-11-2008 | Symposium: Papers Presented at the Annual Meetings of the Knee Society

Less Invasive TKA

Extramedullary Femoral Reference Without Navigation

Authors: Andrea Baldini, MD, Paolo Adravanti, MD

Published in: Clinical Orthopaedics and Related Research® | Issue 11/2008

Login to get access

Abstract

Femoral intramedullary canal referencing is used by most knee arthroplasty systems. Fat embolism, activation of coagulation, and bleeding may occur from the reamed canal. The purpose of our study was to evaluate a new extramedullary device that relies on templated data. We randomized 100 consecutive patients undergoing primary total knee arthroplasty through a limited parapatellar approach to use of either standard intramedullary femoral instruments (IM group) or a new extramedullary device (EM group). The extramedullary instrument was calibrated using templated data obtained from a preoperative full-limb weightbearing anteroposterior view of the knee. In both groups, an intraoperative double check was performed using an extramedullary rod referring to the anterosuperior iliac spine. Femoral component coronal alignment was within 0° ± 2° of the mechanical axis in 84% of the IM group and 86% of the EM group. Sagittal alignment of the femoral component was 0° ± 2° in 78% of the IM group and 90% of the EM group. We observed no difference in the average operative time between the two groups. The two groups showed similar postoperative blood loss. Extramedullary reference with careful preoperative templating can be safely used during TKA.
Level of Evidence: Level II, therapeutic study. See the Guidelines for Authors for a complete description of levels of evidence.
Literature
1.
go back to reference Aglietti P, Baldini A, Sensi L. Quadriceps-sparing versus mini-subvastus approach in total knee arthroplasty. Clin Orthop Relat Res. 2006;452:106–111.PubMedCrossRef Aglietti P, Baldini A, Sensi L. Quadriceps-sparing versus mini-subvastus approach in total knee arthroplasty. Clin Orthop Relat Res. 2006;452:106–111.PubMedCrossRef
2.
go back to reference Aglietti P, Buzzi R, De Felice R, Giron F. The Insall-Burstein total knee replacement in osteoarthritis: a 10-year minimum follow-up. J Arthroplasty. 1999;14:560–565.PubMedCrossRef Aglietti P, Buzzi R, De Felice R, Giron F. The Insall-Burstein total knee replacement in osteoarthritis: a 10-year minimum follow-up. J Arthroplasty. 1999;14:560–565.PubMedCrossRef
3.
go back to reference Berend ME, Ritter MA, Meding JB, Faris PM, Keating EM, Redelman R, Faris GW, Davis KE. Tibial component failure mechanisms in total knee arthroplasty. Clin Orthop Relat Res. 2004;428:26–34.PubMedCrossRef Berend ME, Ritter MA, Meding JB, Faris PM, Keating EM, Redelman R, Faris GW, Davis KE. Tibial component failure mechanisms in total knee arthroplasty. Clin Orthop Relat Res. 2004;428:26–34.PubMedCrossRef
4.
go back to reference Byrick RJ. Fat embolism and postoperative coagulopathy [Editorial]. Can J Anesth. 2001;48:618–621.PubMed Byrick RJ. Fat embolism and postoperative coagulopathy [Editorial]. Can J Anesth. 2001;48:618–621.PubMed
5.
go back to reference Byrick RJ, Forbes D, Waddell JP. A monitored cardiovascular collapse during cemented total knee replacement. Anesthesiology. 1986;65:213–216.PubMedCrossRef Byrick RJ, Forbes D, Waddell JP. A monitored cardiovascular collapse during cemented total knee replacement. Anesthesiology. 1986;65:213–216.PubMedCrossRef
6.
go back to reference Caillouette JT, Anzel SH. Fat embolism syndrome following the intramedullary alignment guide in total knee arthroplasty. Clin Orthop Relat Res. 1990;251:198–199.PubMed Caillouette JT, Anzel SH. Fat embolism syndrome following the intramedullary alignment guide in total knee arthroplasty. Clin Orthop Relat Res. 1990;251:198–199.PubMed
7.
go back to reference Callaghan JJ, Liu SS, Warth LC. Computer-assisted surgery: a wine before its time: in the affirmative. J Arthroplasty. 2006;21(Suppl 1):27–28.PubMedCrossRef Callaghan JJ, Liu SS, Warth LC. Computer-assisted surgery: a wine before its time: in the affirmative. J Arthroplasty. 2006;21(Suppl 1):27–28.PubMedCrossRef
8.
go back to reference Cates HE, Ritter MA, Keating EM, Faris PM. Intramedullary versus extramedullary femoral alignment systems in total knee replacement. Clin Orthop Relat Res. 1993;286:32–39.PubMed Cates HE, Ritter MA, Keating EM, Faris PM. Intramedullary versus extramedullary femoral alignment systems in total knee replacement. Clin Orthop Relat Res. 1993;286:32–39.PubMed
9.
go back to reference Chauhan SK, Scott RG, Breidahl W, Beaver RJ. Computer-assisted knee arthroplasty versus a conventional jig-based technique. A randomised, prospective trial. J Bone Joint Surg Br. 2004;86:372–377.PubMedCrossRef Chauhan SK, Scott RG, Breidahl W, Beaver RJ. Computer-assisted knee arthroplasty versus a conventional jig-based technique. A randomised, prospective trial. J Bone Joint Surg Br. 2004;86:372–377.PubMedCrossRef
10.
go back to reference Church JS, Scadden JE, Gupta RR, Cokis C, Williams KA, Janes GC. Embolic phenomena during computer-assisted and conventional total knee replacement. J Bone Joint Surg Br. 2007;89:481–485.PubMedCrossRef Church JS, Scadden JE, Gupta RR, Cokis C, Williams KA, Janes GC. Embolic phenomena during computer-assisted and conventional total knee replacement. J Bone Joint Surg Br. 2007;89:481–485.PubMedCrossRef
11.
go back to reference Collier MB, Engh CA Jr, McAuley JP, Engh GA. Factors associated with the loss of thickness of polyethylene tibial bearings after knee arthroplasty. J Bone Joint Surg Am. 2007;89:1306–1314.PubMedCrossRef Collier MB, Engh CA Jr, McAuley JP, Engh GA. Factors associated with the loss of thickness of polyethylene tibial bearings after knee arthroplasty. J Bone Joint Surg Am. 2007;89:1306–1314.PubMedCrossRef
12.
go back to reference Dorr LD, Merkel C, Mellman MF, Klein I. Fat emboli in bilateral total knee arthroplasty. Clin Orthop Relat Res. 1989;248:112–119.PubMed Dorr LD, Merkel C, Mellman MF, Klein I. Fat emboli in bilateral total knee arthroplasty. Clin Orthop Relat Res. 1989;248:112–119.PubMed
13.
go back to reference Dutton AQ, Yeo SJ, Yang KY, Lo NN, Chia KU, Chong HC. Computer-assisted minimally invasive total knee arthroplasty compared with standard total knee arthroplasty. A prospective, randomized study. J Bone Joint Surg Am. 2008;90:2–9.PubMedCrossRef Dutton AQ, Yeo SJ, Yang KY, Lo NN, Chia KU, Chong HC. Computer-assisted minimally invasive total knee arthroplasty compared with standard total knee arthroplasty. A prospective, randomized study. J Bone Joint Surg Am. 2008;90:2–9.PubMedCrossRef
14.
go back to reference Engh GA, Petersen TL. Comparative experience with intramedullary and extramedullary alignment in total knee arthroplasty. J Arthroplasty. 1990;5:1–8.PubMedCrossRef Engh GA, Petersen TL. Comparative experience with intramedullary and extramedullary alignment in total knee arthroplasty. J Arthroplasty. 1990;5:1–8.PubMedCrossRef
15.
go back to reference Enneking FK. Cardiac arrest during total knee replacement using a long-stem prosthesis. J Clin Anesth. 1995;7:253–263.PubMedCrossRef Enneking FK. Cardiac arrest during total knee replacement using a long-stem prosthesis. J Clin Anesth. 1995;7:253–263.PubMedCrossRef
16.
go back to reference Ewald FC. The Knee Society total knee arthroplasty roentgenographic evaluation and scoring system. Clin Orthop Relat Res. 1988;248:9–12. Ewald FC. The Knee Society total knee arthroplasty roentgenographic evaluation and scoring system. Clin Orthop Relat Res. 1988;248:9–12.
17.
go back to reference Fahmy NR, Chandler HP, Danylchuk K, Matta EB, Sunder N, Siliski JM. Blood gas and circulatory changes during total knee replacement. J Bone Joint Surg Am. 1990;72:19–26.PubMed Fahmy NR, Chandler HP, Danylchuk K, Matta EB, Sunder N, Siliski JM. Blood gas and circulatory changes during total knee replacement. J Bone Joint Surg Am. 1990;72:19–26.PubMed
18.
go back to reference Gurd AR, Wilson RI. The fat embolism syndrome. J Bone Joint Surg Br. 1974;56:408–416. Gurd AR, Wilson RI. The fat embolism syndrome. J Bone Joint Surg Br. 1974;56:408–416.
19.
go back to reference Hall TM, Callaghan JJ. Fat embolism precipitated by reaming of the femoral canal during revision of a total knee replacement. A case report. J Bone Joint Surg Am. 1994;76:899–903.PubMed Hall TM, Callaghan JJ. Fat embolism precipitated by reaming of the femoral canal during revision of a total knee replacement. A case report. J Bone Joint Surg Am. 1994;76:899–903.PubMed
20.
go back to reference Hofmann S, Frank R, Kratochwill C, Salzer M. Femoral intramedullary pressure and pulmonary fat embolism during uncemented total knee replacement: comparison of different surgical techniques. Orthop Trans. 1996;20:145. Hofmann S, Frank R, Kratochwill C, Salzer M. Femoral intramedullary pressure and pulmonary fat embolism during uncemented total knee replacement: comparison of different surgical techniques. Orthop Trans. 1996;20:145.
21.
go back to reference Ishii Y, Ohmori G, Bechtold JE, Gustilo RB. Extramedullary versus intramedullary alignment guides in total knee arthroplasty. Clin Orthop Relat Res. 1995;318:167–175.PubMed Ishii Y, Ohmori G, Bechtold JE, Gustilo RB. Extramedullary versus intramedullary alignment guides in total knee arthroplasty. Clin Orthop Relat Res. 1995;318:167–175.PubMed
22.
go back to reference Jenkins K, Chung F, Wennberg R, Etchells EE, Davey R. Fat embolism syndrome and elective knee arthroplasty. Can J Anaesth. 2002;49:19–24.PubMedCrossRef Jenkins K, Chung F, Wennberg R, Etchells EE, Davey R. Fat embolism syndrome and elective knee arthroplasty. Can J Anaesth. 2002;49:19–24.PubMedCrossRef
23.
go back to reference Jenny JY, Clemens U, Kohler S, Kiefer H, Konermann W, Miehlke RK. Consistency of implantation of a total knee arthroplasty with a non-image-based navigation system: a case-control study of 235 cases compared with 235 conventionally implanted prostheses. J Arthroplasty. 2005;20:832–839.PubMedCrossRef Jenny JY, Clemens U, Kohler S, Kiefer H, Konermann W, Miehlke RK. Consistency of implantation of a total knee arthroplasty with a non-image-based navigation system: a case-control study of 235 cases compared with 235 conventionally implanted prostheses. J Arthroplasty. 2005;20:832–839.PubMedCrossRef
24.
go back to reference Jiang CC, Insall JN. Effect of rotation on the axial alignment of the femur. Pitfalls in the use of femoral intramedullary guides in total knee arthroplasty. Clin Orthop Relat Res. 1989;248:50–56.PubMed Jiang CC, Insall JN. Effect of rotation on the axial alignment of the femur. Pitfalls in the use of femoral intramedullary guides in total knee arthroplasty. Clin Orthop Relat Res. 1989;248:50–56.PubMed
25.
go back to reference Kalairajah Y, Cossey AJ, Verrall GM, Ludbrook G, Spriggins AJ. Are systemic emboli reduced in computer-assisted knee surgery? A prospective, randomised, clinical trial. J Bone Joint Surg Br. 2006;88:198–202.PubMed Kalairajah Y, Cossey AJ, Verrall GM, Ludbrook G, Spriggins AJ. Are systemic emboli reduced in computer-assisted knee surgery? A prospective, randomised, clinical trial. J Bone Joint Surg Br. 2006;88:198–202.PubMed
26.
go back to reference Kalairajah Y, Simpson D, Cossey AJ, Verrall GM, Spriggins AJ. Blood loss after total knee replacement: effects of computer-assisted surgery. J Bone Joint Surg Br. 2005;87:1480–1482.PubMedCrossRef Kalairajah Y, Simpson D, Cossey AJ, Verrall GM, Spriggins AJ. Blood loss after total knee replacement: effects of computer-assisted surgery. J Bone Joint Surg Br. 2005;87:1480–1482.PubMedCrossRef
27.
go back to reference Kandel L, Vasili C, Kirsh G. Extramedullary femoral alignment instrumentation reduces blood loss after uncemented total knee arthroplasty. J Knee Surg. 2006;19:256–258.PubMed Kandel L, Vasili C, Kirsh G. Extramedullary femoral alignment instrumentation reduces blood loss after uncemented total knee arthroplasty. J Knee Surg. 2006;19:256–258.PubMed
28.
go back to reference Kato N, Nakanishi K, Yoshino S, Ogawa R. Abnormal echogenic findings detected by transesophageal echocardiography and cardiorespiratory impairment during total knee arthroplasty with tourniquet. Anesthesiology. 2002;97:1123–1128.PubMedCrossRef Kato N, Nakanishi K, Yoshino S, Ogawa R. Abnormal echogenic findings detected by transesophageal echocardiography and cardiorespiratory impairment during total knee arthroplasty with tourniquet. Anesthesiology. 2002;97:1123–1128.PubMedCrossRef
29.
go back to reference Kim YH. Incidence of fat embolism syndrome after cemented or cementless bilateral simultaneous and unilateral total knee arthroplasty. J Arthroplasty. 2001;16:730–739.PubMedCrossRef Kim YH. Incidence of fat embolism syndrome after cemented or cementless bilateral simultaneous and unilateral total knee arthroplasty. J Arthroplasty. 2001;16:730–739.PubMedCrossRef
30.
go back to reference Kim YH, Kim JS, Hong KS, Kim YJ, Kim JH. Prevalence of fat embolism after total knee arthroplasty performed with or without computer navigation. J Bone Joint Surg Am. 2008;90:123–128.PubMedCrossRef Kim YH, Kim JS, Hong KS, Kim YJ, Kim JH. Prevalence of fat embolism after total knee arthroplasty performed with or without computer navigation. J Bone Joint Surg Am. 2008;90:123–128.PubMedCrossRef
31.
go back to reference Ko PS, Tio MK, Tang YK, Tsang WL, Lam JJ. Sealing the intramedullary femoral canal with autologous bone plug in total knee arthroplasty. J Arthroplasty. 2003;18:6–9.PubMedCrossRef Ko PS, Tio MK, Tang YK, Tsang WL, Lam JJ. Sealing the intramedullary femoral canal with autologous bone plug in total knee arthroplasty. J Arthroplasty. 2003;18:6–9.PubMedCrossRef
32.
go back to reference Kolettis GT, Wixson RL, Peruzzi WT, Blake MJ, Wardell S, Stulberg SD. Safety of 1-stage bilateral total knee arthroplasty. Clin Orthop Relat Res. 1994;309:102–109.PubMed Kolettis GT, Wixson RL, Peruzzi WT, Blake MJ, Wardell S, Stulberg SD. Safety of 1-stage bilateral total knee arthroplasty. Clin Orthop Relat Res. 1994;309:102–109.PubMed
33.
go back to reference Kumar N, Saleh J, Gardiner E, Devadoss VG, Howell FR. Plugging the intramedullary canal of the femur in total knee arthroplasty: reduction in postoperative blood loss. J Arthroplasty. 2000;15:947–949.PubMedCrossRef Kumar N, Saleh J, Gardiner E, Devadoss VG, Howell FR. Plugging the intramedullary canal of the femur in total knee arthroplasty: reduction in postoperative blood loss. J Arthroplasty. 2000;15:947–949.PubMedCrossRef
34.
go back to reference Lachiewicz PF, Ranawat CS. Fat embolism syndrome following bilateral total knee replacement with total condylar prosthesis: report of two cases. Clin Orthop Relat Res. 1981;160:106–108.PubMed Lachiewicz PF, Ranawat CS. Fat embolism syndrome following bilateral total knee replacement with total condylar prosthesis: report of two cases. Clin Orthop Relat Res. 1981;160:106–108.PubMed
35.
go back to reference Laskin RS. Alignment of total knee components. Orthopedics. 1984;7:62–65. Laskin RS. Alignment of total knee components. Orthopedics. 1984;7:62–65.
36.
go back to reference Laskin RS. Minimally invasive total knee arthroplasty: the results justify its use. Clin Orthop Relat Res. 2005;440:54–59.PubMedCrossRef Laskin RS. Minimally invasive total knee arthroplasty: the results justify its use. Clin Orthop Relat Res. 2005;440:54–59.PubMedCrossRef
37.
go back to reference Lu CC, Chang YT, Hwang CC, Liaw WJ, Shieh JP, Wong CS, Ho ST. Fat embolism syndrome following bilateral total knee replacement with total condylar prosthesis—a case report. Acta Anaesthesiol Sin. 1995;33:69–77.PubMed Lu CC, Chang YT, Hwang CC, Liaw WJ, Shieh JP, Wong CS, Ho ST. Fat embolism syndrome following bilateral total knee replacement with total condylar prosthesis—a case report. Acta Anaesthesiol Sin. 1995;33:69–77.PubMed
38.
go back to reference Ma B, Long W, Rudan JF, Ellis RE. Three-dimensional analysis of alignment error in using femoral intramedullary guides in unicompartmental knee arthroplasty. J Arthroplasty. 2006;21:271–278.PubMedCrossRef Ma B, Long W, Rudan JF, Ellis RE. Three-dimensional analysis of alignment error in using femoral intramedullary guides in unicompartmental knee arthroplasty. J Arthroplasty. 2006;21:271–278.PubMedCrossRef
39.
go back to reference Markel DC, Femino JE, Farkas P, Markel SF. Analysis of lower extremity embolic material after total knee arthroplasty in a canine model. J Arthroplasty. 1999;14:227–232.PubMedCrossRef Markel DC, Femino JE, Farkas P, Markel SF. Analysis of lower extremity embolic material after total knee arthroplasty in a canine model. J Arthroplasty. 1999;14:227–232.PubMedCrossRef
40.
go back to reference Mihalko WM, Boyle J, Clark LD, Krackow KA. The variability of intramedullary alignment of the femoral component during total knee arthroplasty. J Arthroplasty. 2005;20:25–28.PubMedCrossRef Mihalko WM, Boyle J, Clark LD, Krackow KA. The variability of intramedullary alignment of the femoral component during total knee arthroplasty. J Arthroplasty. 2005;20:25–28.PubMedCrossRef
41.
go back to reference Monto RR, Garcia J, Callaghan JJ. Fatal fat embolism following total condylar knee arthroplasty. J Arthroplasty. 1990;5:291–299.PubMedCrossRef Monto RR, Garcia J, Callaghan JJ. Fatal fat embolism following total condylar knee arthroplasty. J Arthroplasty. 1990;5:291–299.PubMedCrossRef
42.
go back to reference Morawa LG, Manley MT, Edidin AA, Reilly DT. Transesophageal echocardiographic monitored events during total knee arthroplasty. Clin Orthop Relat Res. 1996;331:192–198.PubMedCrossRef Morawa LG, Manley MT, Edidin AA, Reilly DT. Transesophageal echocardiographic monitored events during total knee arthroplasty. Clin Orthop Relat Res. 1996;331:192–198.PubMedCrossRef
43.
go back to reference Nuño-Siebrecht N, Tanzer M, Bobyn JD. Potential errors in axial alignment using intramedullary instrumentation for total knee arthroplasty. J Arthroplasty. 2000;15:228–230.PubMedCrossRef Nuño-Siebrecht N, Tanzer M, Bobyn JD. Potential errors in axial alignment using intramedullary instrumentation for total knee arthroplasty. J Arthroplasty. 2000;15:228–230.PubMedCrossRef
44.
go back to reference Orsini EC, Richards RR, Mullen JMB. Fatal fat embolism during cemented total knee arthroplasty: a case report. Can J Surg. 1986;29:385–386.PubMed Orsini EC, Richards RR, Mullen JMB. Fatal fat embolism during cemented total knee arthroplasty: a case report. Can J Surg. 1986;29:385–386.PubMed
45.
go back to reference Pagnano MW, Meneghini RM, Trousdale RT. Anatomy of the extensor mechanism in reference to quadriceps-sparing TKA. Clin Orthop Relat Res. 2006;452:102–105.PubMedCrossRef Pagnano MW, Meneghini RM, Trousdale RT. Anatomy of the extensor mechanism in reference to quadriceps-sparing TKA. Clin Orthop Relat Res. 2006;452:102–105.PubMedCrossRef
46.
go back to reference Raut VV, Stone MH, Wroblewski BM. Reduction of postoperative blood loss after press-fit condylar knee arthroplasty with use of a femoral intramedullary plug. J Bone Joint Surg Am. 1993;75:1356–1357.PubMed Raut VV, Stone MH, Wroblewski BM. Reduction of postoperative blood loss after press-fit condylar knee arthroplasty with use of a femoral intramedullary plug. J Bone Joint Surg Am. 1993;75:1356–1357.PubMed
47.
go back to reference Reed SC, Gollish J. The accuracy of femoral intramedullary guides in total knee arthroplasty. J Arthroplasty. 1997;12:677–682.PubMedCrossRef Reed SC, Gollish J. The accuracy of femoral intramedullary guides in total knee arthroplasty. J Arthroplasty. 1997;12:677–682.PubMedCrossRef
48.
go back to reference Samii K, Elmelik E, Mourtada MB, Debeyre J, Rapin M. Intraoperative hemodynamic changes during total knee replacement. Anesthesiology. 1979;50:239–242.PubMedCrossRef Samii K, Elmelik E, Mourtada MB, Debeyre J, Rapin M. Intraoperative hemodynamic changes during total knee replacement. Anesthesiology. 1979;50:239–242.PubMedCrossRef
49.
go back to reference Stern SH, Sharrock N, Kahn R, lnsall JN. Hematologic and circulatory changes associated with total knee arthroplasty surgical instrumentation. Clin Orthop Relat Res. 1994;299:179–189.PubMed Stern SH, Sharrock N, Kahn R, lnsall JN. Hematologic and circulatory changes associated with total knee arthroplasty surgical instrumentation. Clin Orthop Relat Res. 1994;299:179–189.PubMed
50.
go back to reference Sulek CA, Davies LK, Enneking FK, Gearen PA, Lobato EB. Cerebral microembolism diagnosed by transcranial Doppler during total knee arthroplasty: correlation with transesophageal echocardiography. Anesthesiology. 1999;91:672–676.PubMedCrossRef Sulek CA, Davies LK, Enneking FK, Gearen PA, Lobato EB. Cerebral microembolism diagnosed by transcranial Doppler during total knee arthroplasty: correlation with transesophageal echocardiography. Anesthesiology. 1999;91:672–676.PubMedCrossRef
51.
go back to reference Teter KE, Bregman D, Colwell CW Jr. The efficacy of intramedullary femoral alignment in total knee replacement. Clin Orthop Relat Res. 1995;321:117–121.PubMed Teter KE, Bregman D, Colwell CW Jr. The efficacy of intramedullary femoral alignment in total knee replacement. Clin Orthop Relat Res. 1995;321:117–121.PubMed
52.
go back to reference Tillett ED, Engh GA, Peterson T. A comparative study of extramedullary and intramedullary alignment systems in total knee arthroplasty. Clin Orthop Relat Res. 1988;230:176–181.PubMed Tillett ED, Engh GA, Peterson T. A comparative study of extramedullary and intramedullary alignment systems in total knee arthroplasty. Clin Orthop Relat Res. 1988;230:176–181.PubMed
53.
go back to reference Tria AJ Jr, Coon TM. Minimally incision total knee arthroplasty: early experience. Clin Orthop Relat Res. 2003;416:185–190.PubMedCrossRef Tria AJ Jr, Coon TM. Minimally incision total knee arthroplasty: early experience. Clin Orthop Relat Res. 2003;416:185–190.PubMedCrossRef
54.
go back to reference Vince KG. Fat embolism and total knee arthroplasty. Can J Surg. 1987;30:227.PubMed Vince KG. Fat embolism and total knee arthroplasty. Can J Surg. 1987;30:227.PubMed
55.
go back to reference Weiss SJ, Cheung AT, Stecker MM, Garino JP, Hughes JE, Murphy FL Jr. Fatal paradoxical cerebral embolization during bilateral knee arthroplasty. Anesthesiology. 1996;84:721–723.PubMedCrossRef Weiss SJ, Cheung AT, Stecker MM, Garino JP, Hughes JE, Murphy FL Jr. Fatal paradoxical cerebral embolization during bilateral knee arthroplasty. Anesthesiology. 1996;84:721–723.PubMedCrossRef
56.
go back to reference Windsor RE, Scuderi GR, Moran MC, Insall JN. Mechanisms of failure of the femoral and tibial components in total knee arthroplasty. Clin Orthop Relat Res. 1989;248:15–19; discussion 19–20.PubMed Windsor RE, Scuderi GR, Moran MC, Insall JN. Mechanisms of failure of the femoral and tibial components in total knee arthroplasty. Clin Orthop Relat Res. 1989;248:15–19; discussion 19–20.PubMed
57.
go back to reference Wolf LD, Hozack WJ, Rothman RH. Pulmonary embolism in total joint arthroplasty. Clin Orthop Relat Res. 1993;288:219–223.PubMed Wolf LD, Hozack WJ, Rothman RH. Pulmonary embolism in total joint arthroplasty. Clin Orthop Relat Res. 1993;288:219–223.PubMed
58.
go back to reference Zimmerman RL, Kroner LF III, Blomberg DJ, Nollet DJ. Fatal fat embolism following total knee arthroplasty. Minn Med. 1983;66:213–216.PubMed Zimmerman RL, Kroner LF III, Blomberg DJ, Nollet DJ. Fatal fat embolism following total knee arthroplasty. Minn Med. 1983;66:213–216.PubMed
Metadata
Title
Less Invasive TKA
Extramedullary Femoral Reference Without Navigation
Authors
Andrea Baldini, MD
Paolo Adravanti, MD
Publication date
01-11-2008
Publisher
Springer-Verlag
Published in
Clinical Orthopaedics and Related Research® / Issue 11/2008
Print ISSN: 0009-921X
Electronic ISSN: 1528-1132
DOI
https://doi.org/10.1007/s11999-008-0435-9

Other articles of this Issue 11/2008

Clinical Orthopaedics and Related Research® 11/2008 Go to the issue

Symposium: Papers Presented at the Annual Meetings of the Knee Society

Management of the Deficient Patella in Revision Total Knee Arthroplasty

Symposium: Papers Presented at the Annual Meetings of the Knee Society

Polyethylene Wear Is Influenced by Manufacturing Technique in Modular TKA

Symposium: Papers Presented at the Annual Meetings of the Knee Society

Navigation Did Not Improve the Precision of Minimally Invasive Knee Arthroplasty

Symposium: Papers Presented at the Annual Meetings of the Knee Society

Tribute to Richard S. Laskin, MD, 1940–2008

Symposium: Papers Presented at the Annual Meetings of the Knee Society

Diagnosis of Infected Total Knee: Findings of a Multicenter Database