Bilevel positive airway pressure ventilation: factors influencing carbon dioxide rebreathing

Authors: Zbigniew Szkulmowski, Kheirallah Belkhouja, Quoc-Hung Le, Dominique Robert, Laurent Argaud

Published in: Intensive Care Medicine | Issue 4/2010

Login to get access

Abstract

Purpose

Use of bilevel positive airway pressure (BLPAP) ventilators for noninvasive ventilation (NIV) is an established treatment for both acute and chronic ventilatory failure. Although BLPAP ventilator circuits are simpler than those of conventional ventilators, one drawback to their use is that they allow variable amounts of rebreathing to occur. The aim of this work is to measure the amount of CO2 reinsufflated in relation to the BLPAP ventilator circuit in patients, and to determine predictive factors for rebreathing.

Methods

Eighteen adult patients were ventilated on pressure support, either by intubation or with mask ventilation, during a weaning period. The mean inspiratory fraction of CO2 (tidal FiCO2) reinsufflated from the circuit between the intentional leak and the ventilator was measured for each breath. The influence of end-tidal CO2 concentration (ETCO2), respiratory rate (RR), percentage of inspiratory time (T i/T TOT), application of expiratory positive airway pressure (EPAP), and inspiratory tidal volume on magnitude of tidal FiCO2, as well as the influence of intubation versus NIV, were studied by univariate comparisons and logistic regression analysis.

Results

In a total of 11,107 cycles, tidal FiCO2 was 0.072 ± 0.173%. Of fractions measured, 8,976 (81%) were under 0.10% and 2,131 (19%) were over 0.10%, with mean values of 0.026 ± 0.027% and 0.239 ± 0.326%, respectively. ETCO2, EPAP, NIV versus intubation, and RR had significant predictive value for tidal FiCO2 >0.10%.

Conclusions

BLPAP ventilators present a specific rebreathing risk to patients. However, that risk remains modest, even in intubated patients, provided that EPAP is applied.
Literature
1.
go back to reference Sanders MH, Kern N (1990) Obstructive sleep apnea treated by independently adjusted inspiratory and expiratory positive airway pressures via nasal mask. Physiologic and clinical implications. Chest 98:317–324CrossRefPubMed Sanders MH, Kern N (1990) Obstructive sleep apnea treated by independently adjusted inspiratory and expiratory positive airway pressures via nasal mask. Physiologic and clinical implications. Chest 98:317–324CrossRefPubMed
2.
go back to reference Strumpf DA, Millman RP, Carlisle CC, Grattan LM, Ryan SM, Erickson AD, Hill NS (1990) An evaluation of the Respironics BiPAP bi-level CPAP device for delivery of assisted ventilation. Respir Care 35:415–422 Strumpf DA, Millman RP, Carlisle CC, Grattan LM, Ryan SM, Erickson AD, Hill NS (1990) An evaluation of the Respironics BiPAP bi-level CPAP device for delivery of assisted ventilation. Respir Care 35:415–422
3.
go back to reference Lofaso F, Brochard L, Hang T, Lorino H, Harf A, Isabey D (1996) Home versus intensive care pressure support devices. Experimental and clinical comparison. Am J Respir Crit Care Med 153:1591–1599PubMed Lofaso F, Brochard L, Hang T, Lorino H, Harf A, Isabey D (1996) Home versus intensive care pressure support devices. Experimental and clinical comparison. Am J Respir Crit Care Med 153:1591–1599PubMed
4.
go back to reference Pennock BE, Crawshaw L, Kaplan PD (1994) Noninvasive nasal mask ventilation for acute respiratory failure. Institution of a new therapeutic technology for routine use. Chest 105:441–444CrossRefPubMed Pennock BE, Crawshaw L, Kaplan PD (1994) Noninvasive nasal mask ventilation for acute respiratory failure. Institution of a new therapeutic technology for routine use. Chest 105:441–444CrossRefPubMed
5.
go back to reference Pollack C Jr, Torres MT, Alexander L (1996) Feasibility study of the use of bilevel positive airway pressure for respiratory support in the emergency department. Ann Emerg Med 27:189–192CrossRefPubMed Pollack C Jr, Torres MT, Alexander L (1996) Feasibility study of the use of bilevel positive airway pressure for respiratory support in the emergency department. Ann Emerg Med 27:189–192CrossRefPubMed
6.
go back to reference Auriant I, Jallot A, Herve P, Cerrina J, Le Roy Ladurie F, Fournier JL, Lescot B, Parquin F (2001) Noninvasive ventilation reduces mortality in acute respiratory failure following lung resection. Am J Respir Crit Care Med 164:1231–1235PubMed Auriant I, Jallot A, Herve P, Cerrina J, Le Roy Ladurie F, Fournier JL, Lescot B, Parquin F (2001) Noninvasive ventilation reduces mortality in acute respiratory failure following lung resection. Am J Respir Crit Care Med 164:1231–1235PubMed
7.
go back to reference Cross AM, Cameron P, Kierce M, Ragg M, Kelly AM (2003) Non-invasive ventilation in acute respiratory failure: a randomised comparison of continuous positive airway pressure and bi-level positive airway pressure. Emerg Med J 20:531–534CrossRefPubMed Cross AM, Cameron P, Kierce M, Ragg M, Kelly AM (2003) Non-invasive ventilation in acute respiratory failure: a randomised comparison of continuous positive airway pressure and bi-level positive airway pressure. Emerg Med J 20:531–534CrossRefPubMed
8.
go back to reference Lloyd-Owen SJ, Donaldson GC, Ambrosino N, Escarabill J, Farre R, Fauroux B, Robert D, Schoenhofer B, Simonds AK, Wedzicha JA (2005) Patterns of home mechanical ventilation use in Europe: results from the Eurovent survey. Eur Respir J 25:1025–1031CrossRefPubMed Lloyd-Owen SJ, Donaldson GC, Ambrosino N, Escarabill J, Farre R, Fauroux B, Robert D, Schoenhofer B, Simonds AK, Wedzicha JA (2005) Patterns of home mechanical ventilation use in Europe: results from the Eurovent survey. Eur Respir J 25:1025–1031CrossRefPubMed
9.
go back to reference Caples SM, Gay PC (2005) Noninvasive positive pressure ventilation in the intensive care unit: a concise review. Crit Care Med 33:2651–2658CrossRefPubMed Caples SM, Gay PC (2005) Noninvasive positive pressure ventilation in the intensive care unit: a concise review. Crit Care Med 33:2651–2658CrossRefPubMed
10.
go back to reference Patel RG, Petrini MF (1998) Respiratory muscle performance, pulmonary mechanics, and gas exchange between the BiPAP S/T-D system and the Servo Ventilator 900C with bilevel positive airway pressure ventilation following gradual pressure support weaning. Chest 114:1390–1396CrossRefPubMed Patel RG, Petrini MF (1998) Respiratory muscle performance, pulmonary mechanics, and gas exchange between the BiPAP S/T-D system and the Servo Ventilator 900C with bilevel positive airway pressure ventilation following gradual pressure support weaning. Chest 114:1390–1396CrossRefPubMed
11.
go back to reference Schettino GP, Chatmongkolchart S, Hess DR, Kacmarek RM (2003) Position of exhalation port and mask design affect CO2 rebreathing during noninvasive positive pressure ventilation. Crit Care Med 31:2178–2182CrossRefPubMed Schettino GP, Chatmongkolchart S, Hess DR, Kacmarek RM (2003) Position of exhalation port and mask design affect CO2 rebreathing during noninvasive positive pressure ventilation. Crit Care Med 31:2178–2182CrossRefPubMed
12.
go back to reference Lofaso F, Brochard L, Touchard D, Hang T, Harf A, Isabey D (1995) Evaluation of carbon dioxide rebreathing during pressure support ventilation with airway management system (BiPAP) devices. Chest 108:772–778CrossRefPubMed Lofaso F, Brochard L, Touchard D, Hang T, Harf A, Isabey D (1995) Evaluation of carbon dioxide rebreathing during pressure support ventilation with airway management system (BiPAP) devices. Chest 108:772–778CrossRefPubMed
13.
go back to reference Ferguson GT, Gilmartin M (1995) CO2 rebreathing during BiPAP ventilatory assistance. Am J Respir Crit Care Med 151:1126–1135PubMed Ferguson GT, Gilmartin M (1995) CO2 rebreathing during BiPAP ventilatory assistance. Am J Respir Crit Care Med 151:1126–1135PubMed
14.
go back to reference Hill NS, Carlisle C, Kramer NR (2002) Effect of a nonrebreathing exhalation valve on long-term nasal ventilation using a bilevel device. Chest 122:84–91CrossRefPubMed Hill NS, Carlisle C, Kramer NR (2002) Effect of a nonrebreathing exhalation valve on long-term nasal ventilation using a bilevel device. Chest 122:84–91CrossRefPubMed
15.
go back to reference Scheid P, Lofaso F, Isabey D, Harf A (1994) Respiratory response to inhaled CO2 during positive inspiratory pressure in humans. J Appl Physiol 77:876–882PubMed Scheid P, Lofaso F, Isabey D, Harf A (1994) Respiratory response to inhaled CO2 during positive inspiratory pressure in humans. J Appl Physiol 77:876–882PubMed
16.
go back to reference Georgopoulos D, Mitrouska I, Bshouty Z, Webster K, Patakas D, Younes M (1997) Respiratory response to CO2 during pressure-support ventilation in conscious normal humans. Am J Respir Crit Care Med 156:146–154PubMed Georgopoulos D, Mitrouska I, Bshouty Z, Webster K, Patakas D, Younes M (1997) Respiratory response to CO2 during pressure-support ventilation in conscious normal humans. Am J Respir Crit Care Med 156:146–154PubMed
Metadata
Title
Bilevel positive airway pressure ventilation: factors influencing carbon dioxide rebreathing
Authors
Zbigniew Szkulmowski
Kheirallah Belkhouja
Quoc-Hung Le
Dominique Robert
Laurent Argaud
Publication date
01-04-2010
Publisher
Springer-Verlag
Published in
Intensive Care Medicine / Issue 4/2010
Print ISSN: 0342-4642
Electronic ISSN: 1432-1238
DOI
https://doi.org/10.1007/s00134-010-1774-z

Other articles of this Issue 4/2010

Intensive Care Medicine 4/2010 Go to the issue