Skip to main content
Top
Published in: Intensive Care Medicine 7/2007

01-07-2007 | Original

Can dynamic indicators help the prediction of fluid responsiveness in spontaneously breathing critically ill patients?

Authors: Stéphane Soubrier, Fabienne Saulnier, Hervé Hubert, Pierre Delour, Hélène Lenci, Thierry Onimus, Saad Nseir, Alain Durocher

Published in: Intensive Care Medicine | Issue 7/2007

Login to get access

Abstract

Objective

To investigate whether the respiratory changes in arterial pulse (ΔPP) and in systolic pressure (ΔSP) could predict fluid responsiveness in spontaneously breathing (SB) patients. Because changes in intrathoracic pressure during spontaneous breathing (SB) might be insufficient to modify loading conditions of the ventricles, performances of indicators were also assessed during a forced respiratory maneuver.

Design

Prospective interventional study.

Setting

A 34-bed university hospital medico-surgical ICU.

Patients and participants

Thirty-two SB patients with clinical signs of hemodynamic instability.

Intervention

A 500-ml volume expansion (VE).

Measurements and results

Cardiac index, assessed using transthoracic echocardiography, increased by at least 15% after VE in 19 patients (responders). At baseline, only dynamic indicators were higher in responders than in nonresponders (13 ± 5% vs. 7 ± 3%, p = 0.003 for ΔPP and 10 ± 4% vs. 6 ± 2%, p = 0.002 for ΔSP). Moreover, they significantly decreased after VE (11 ± 5% to 6 ± 4%, p < 0.001 for ΔPP and 8 ± 4% to 6 ± 3%, p < 0.001 for ΔSP). ΔPP and ΔSP areas under the ROC curve were high (0.81 ± 0.08 and 0.82 ± 0.08; p = 0.888, respectively). A ΔPP ≥ 12% predicted fluid responsiveness with high specificity (92%) but poor sensitivity (63%). The forced respiratory maneuver reproducing a dyspneic state decreased the predictive power.

Conclusions

Due to their lack of sensitivity and their dependence to respiratory status, ΔPP and ΔSP are clearly less reliable to predict fluid responsiveness during SB than in mechanically ventilated patients. However, when their baseline value is high without acute right ventricular dysfunction in a participating patient, a positive response to fluid is likely.
Literature
1.
go back to reference Michard F, Teboul JL (2002) Predicting fluid responsiveness in ICU patients: a critical analysis of the evidence. Chest 121:2000–2008CrossRefPubMed Michard F, Teboul JL (2002) Predicting fluid responsiveness in ICU patients: a critical analysis of the evidence. Chest 121:2000–2008CrossRefPubMed
2.
go back to reference Michard F, Boussat S, Chemla D, Anguel N, Mercat A, Lecarpentier Y, Richard C, Pinsky MR, Teboul JL (2000) Relation between respiratory changes in arterial pulse pressure and fluid responsiveness in septic patients with acute circulatory failure. Am J Respir Crit Care Med 162:134–138CrossRefPubMed Michard F, Boussat S, Chemla D, Anguel N, Mercat A, Lecarpentier Y, Richard C, Pinsky MR, Teboul JL (2000) Relation between respiratory changes in arterial pulse pressure and fluid responsiveness in septic patients with acute circulatory failure. Am J Respir Crit Care Med 162:134–138CrossRefPubMed
3.
go back to reference Tavernier B, Makhotine O, Lebuffe G, Dupont J, Scherpereel P (1998) Systolic pressure variation as a guide to fluid therapy in patients with sepsis-induced hypotension. Anesthesiology 89:1313–1321CrossRefPubMed Tavernier B, Makhotine O, Lebuffe G, Dupont J, Scherpereel P (1998) Systolic pressure variation as a guide to fluid therapy in patients with sepsis-induced hypotension. Anesthesiology 89:1313–1321CrossRefPubMed
4.
go back to reference Berkenstadt H, Margalit N, Hadani M, Friedman Z, Segal E, Villa Y, Perel A (2001) Stroke volume variation as a predictor of fluid responsiveness in patients undergoing brain surgery. Anesth Analg 92:984–989CrossRefPubMed Berkenstadt H, Margalit N, Hadani M, Friedman Z, Segal E, Villa Y, Perel A (2001) Stroke volume variation as a predictor of fluid responsiveness in patients undergoing brain surgery. Anesth Analg 92:984–989CrossRefPubMed
5.
go back to reference Feissel M, Michard F, Mangin I, Ruyer O, Faller JP, Teboul JL (2001) Respiratory changes in aortic blood velocity as an indicator of fluid responsiveness in ventilated patients with septic shock. Chest 119:867–873CrossRefPubMed Feissel M, Michard F, Mangin I, Ruyer O, Faller JP, Teboul JL (2001) Respiratory changes in aortic blood velocity as an indicator of fluid responsiveness in ventilated patients with septic shock. Chest 119:867–873CrossRefPubMed
6.
go back to reference Barbier C, Loubieres Y, Schmit C, Hayon J, Ricome JL, Jardin F, Vieillard-Baron A (2004) Respiratory changes in inferior vena cava diameter are helpful in predicting fluid responsiveness in ventilated septic patients. Intensive Care Med 30:1740–1746PubMed Barbier C, Loubieres Y, Schmit C, Hayon J, Ricome JL, Jardin F, Vieillard-Baron A (2004) Respiratory changes in inferior vena cava diameter are helpful in predicting fluid responsiveness in ventilated septic patients. Intensive Care Med 30:1740–1746PubMed
7.
go back to reference Vieillard-Baron A, Augarde R, Prin S, Page B, Beauchet A, Jardin F (2001) Influence of superior vena caval zone condition on cyclic changes in right ventricular outflow during respiratory support. Anesthesiology 95:1083–1088CrossRefPubMed Vieillard-Baron A, Augarde R, Prin S, Page B, Beauchet A, Jardin F (2001) Influence of superior vena caval zone condition on cyclic changes in right ventricular outflow during respiratory support. Anesthesiology 95:1083–1088CrossRefPubMed
8.
go back to reference Feissel M, Michard F, Faller JP, Teboul JL (2004) The respiratory variation in inferior vena cava diameter as a guide to fluid therapy. Intensive Care Med 30:1834–1837CrossRefPubMed Feissel M, Michard F, Faller JP, Teboul JL (2004) The respiratory variation in inferior vena cava diameter as a guide to fluid therapy. Intensive Care Med 30:1834–1837CrossRefPubMed
9.
go back to reference Monnet X, Rienzo M, Osman D, Anguel N, Richard C, Pinsky MR, Teboul JL (2005) Esophageal Doppler monitoring predicts fluid responsiveness in critically ill ventilated patients. Intensive Care Med 31:1195–1201CrossRefPubMed Monnet X, Rienzo M, Osman D, Anguel N, Richard C, Pinsky MR, Teboul JL (2005) Esophageal Doppler monitoring predicts fluid responsiveness in critically ill ventilated patients. Intensive Care Med 31:1195–1201CrossRefPubMed
10.
go back to reference Vallee F, Fourcade O, De SO, Angles O, Sanchez-Verlaan P, Pillard F, Smail N, Olivier M, Genestal M, Samii K (2005) Stroke output variations calculated by esophageal Doppler is a reliable predictor of fluid response. Intensive Care Med 31:1388–1393CrossRefPubMed Vallee F, Fourcade O, De SO, Angles O, Sanchez-Verlaan P, Pillard F, Smail N, Olivier M, Genestal M, Samii K (2005) Stroke output variations calculated by esophageal Doppler is a reliable predictor of fluid response. Intensive Care Med 31:1388–1393CrossRefPubMed
11.
go back to reference Permutt S (1989) How changes in pleural and alveolar pressure cause changes in afterload and preload. In: Sharf SM, Cassidy SS (eds) Heart–lung interactions in health and disease. Dekker, New York, pp 243–250 Permutt S (1989) How changes in pleural and alveolar pressure cause changes in afterload and preload. In: Sharf SM, Cassidy SS (eds) Heart–lung interactions in health and disease. Dekker, New York, pp 243–250
12.
go back to reference Jardin F, Delorme G, Hardy A, Auvert B, Beauchet A, Bourdarias JP (1990) Reevaluation of hemodynamic consequences of positive pressure ventilation: emphasis on cyclic right ventricular afterloading by mechanical lung inflation. Anesthesiology 72:966–970CrossRefPubMed Jardin F, Delorme G, Hardy A, Auvert B, Beauchet A, Bourdarias JP (1990) Reevaluation of hemodynamic consequences of positive pressure ventilation: emphasis on cyclic right ventricular afterloading by mechanical lung inflation. Anesthesiology 72:966–970CrossRefPubMed
13.
go back to reference Jardin F, Farcot JC, Gueret P, Prost JF, Ozier Y, Bourdarias JP (1983) Cyclic changes in arterial pulse during respiratory support. Circulation 68:266–274CrossRefPubMed Jardin F, Farcot JC, Gueret P, Prost JF, Ozier Y, Bourdarias JP (1983) Cyclic changes in arterial pulse during respiratory support. Circulation 68:266–274CrossRefPubMed
14.
go back to reference Brower R, Wise RA, Hassapoyannes C, Bromberger-Barnea B, Permutt S (1985) Effect of lung inflation on lung blood volume and pulmonary venous flow. J Appl Physiol 58:954–963CrossRefPubMed Brower R, Wise RA, Hassapoyannes C, Bromberger-Barnea B, Permutt S (1985) Effect of lung inflation on lung blood volume and pulmonary venous flow. J Appl Physiol 58:954–963CrossRefPubMed
15.
go back to reference Fessler HE, Brower RG, Wise RA, Permutt S (1988) Mechanism of reduced LV afterload by systolic and diastolic positive pleural pressure. J Appl Physiol 65:1244–1250CrossRefPubMed Fessler HE, Brower RG, Wise RA, Permutt S (1988) Mechanism of reduced LV afterload by systolic and diastolic positive pleural pressure. J Appl Physiol 65:1244–1250CrossRefPubMed
16.
18.
go back to reference Société de Réanimation de Langue Française (2004) Indicateurs du remplissage vasculaire au cours de l'insuffisance circulatoire. Recommandations d'experts. Réanimation 13:253–320CrossRef Société de Réanimation de Langue Française (2004) Indicateurs du remplissage vasculaire au cours de l'insuffisance circulatoire. Recommandations d'experts. Réanimation 13:253–320CrossRef
19.
go back to reference Coudray A, Romand JA, Treggiari M, Bendjelid K (2005) Fluid responsiveness in spontaneously breathing patients: a review of indexes used in intensive care. Crit Care Med 33:2757–2762CrossRefPubMed Coudray A, Romand JA, Treggiari M, Bendjelid K (2005) Fluid responsiveness in spontaneously breathing patients: a review of indexes used in intensive care. Crit Care Med 33:2757–2762CrossRefPubMed
20.
go back to reference De Backer D, Heenen S, Piagnerelli M, Koch M, Vincent JL (2005) Pulse pressure variations to predict fluid responsiveness: influence of tidal volume. Intensive Care Med 31:517–523CrossRefPubMed De Backer D, Heenen S, Piagnerelli M, Koch M, Vincent JL (2005) Pulse pressure variations to predict fluid responsiveness: influence of tidal volume. Intensive Care Med 31:517–523CrossRefPubMed
21.
go back to reference Reuter DA, Bayerlein J, Goepfert MS, Weis FC, Kilger E, Lamm P, Goetz AE (2003) Influence of tidal volume on left ventricular stroke volume variation measured by pulse contour analysis in mechanically ventilated patients. Intensive Care Med 29:476–480CrossRefPubMed Reuter DA, Bayerlein J, Goepfert MS, Weis FC, Kilger E, Lamm P, Goetz AE (2003) Influence of tidal volume on left ventricular stroke volume variation measured by pulse contour analysis in mechanically ventilated patients. Intensive Care Med 29:476–480CrossRefPubMed
22.
go back to reference Szold A, Pizov R, Segal E, Perel A (1989) The effect of tidal volume and intravascular volume state on systolic pressure variation in ventilated dogs. Intensive Care Med 15:368–371CrossRefPubMed Szold A, Pizov R, Segal E, Perel A (1989) The effect of tidal volume and intravascular volume state on systolic pressure variation in ventilated dogs. Intensive Care Med 15:368–371CrossRefPubMed
24.
go back to reference Dericbourg C, Tribouilloy C, Kugener H, Avinee P, Rey JL, Lesbre JP (1990) Noninvasive measurement of cardiac output by pulsed Doppler echocardiography. Correlation with thermodilution. Arch Mal Coeur Vaiss 83:237–244PubMed Dericbourg C, Tribouilloy C, Kugener H, Avinee P, Rey JL, Lesbre JP (1990) Noninvasive measurement of cardiac output by pulsed Doppler echocardiography. Correlation with thermodilution. Arch Mal Coeur Vaiss 83:237–244PubMed
25.
go back to reference Ihlen H, Amlie JP, Dale J, Forfang K, Nitter-Hauge S, Otterstad JE, Simonsen S, Myhre E (1984) Determination of cardiac output by Doppler echocardiography. Br Heart J 51:54–60CrossRefPubMedPubMedCentral Ihlen H, Amlie JP, Dale J, Forfang K, Nitter-Hauge S, Otterstad JE, Simonsen S, Myhre E (1984) Determination of cardiac output by Doppler echocardiography. Br Heart J 51:54–60CrossRefPubMedPubMedCentral
26.
go back to reference Hanley JA, McNeil BJ (1983) A method of comparing the areas under receiver operating characteristic curves derived from the same cases. Radiology 148:839–843CrossRefPubMed Hanley JA, McNeil BJ (1983) A method of comparing the areas under receiver operating characteristic curves derived from the same cases. Radiology 148:839–843CrossRefPubMed
27.
go back to reference Saulnier F (2004) Indices dynamiques prédictifs de la réponse au remplissage vasculaire. Recommandation d'experts. Réanimation 13:299–305CrossRef Saulnier F (2004) Indices dynamiques prédictifs de la réponse au remplissage vasculaire. Recommandation d'experts. Réanimation 13:299–305CrossRef
28.
go back to reference Monnet X, Rienzo M, Osman D, Anguel N, Richard C, Pinsky MR, Teboul JL (2006) Passive leg raising predicts fluid responsiveness in the critically ill. Crit Care Med 34:1402–1407CrossRefPubMed Monnet X, Rienzo M, Osman D, Anguel N, Richard C, Pinsky MR, Teboul JL (2006) Passive leg raising predicts fluid responsiveness in the critically ill. Crit Care Med 34:1402–1407CrossRefPubMed
29.
go back to reference Heenen S, De Backer D, Vincent JL (2006) How can the response to volume expansion in patients with spontaneous respiratory movements be predicted? Crit Care 10:R102CrossRefPubMedPubMedCentral Heenen S, De Backer D, Vincent JL (2006) How can the response to volume expansion in patients with spontaneous respiratory movements be predicted? Crit Care 10:R102CrossRefPubMedPubMedCentral
30.
31.
33.
go back to reference Magder S, Georgiadis G, Cheong T (1992) Respiratory variations in right atrial pressure predict the response to fluid challenge. J Crit Care 7:76–85CrossRef Magder S, Georgiadis G, Cheong T (1992) Respiratory variations in right atrial pressure predict the response to fluid challenge. J Crit Care 7:76–85CrossRef
34.
go back to reference Magder S, Lagonidis D (1999) Effectiveness of albumin versus normal saline as a test of volume responsiveness in post-cardiac surgery patients. J Crit Care 14:164–171CrossRefPubMed Magder S, Lagonidis D (1999) Effectiveness of albumin versus normal saline as a test of volume responsiveness in post-cardiac surgery patients. J Crit Care 14:164–171CrossRefPubMed
35.
go back to reference Teboul JL, Vieillard-Baron A (2005) Clinical value of pulse pressure variations in ARDS. Still an unresolved issue? Intensive Care Med 31:499–500CrossRefPubMed Teboul JL, Vieillard-Baron A (2005) Clinical value of pulse pressure variations in ARDS. Still an unresolved issue? Intensive Care Med 31:499–500CrossRefPubMed
36.
go back to reference McLean AS, Needham A, Stewart D, Parkin R (1997) Estimation of cardiac output by noninvasive echocardiographic techniques in the critically ill subject. Anaesth Intensive Care 25:250–254PubMed McLean AS, Needham A, Stewart D, Parkin R (1997) Estimation of cardiac output by noninvasive echocardiographic techniques in the critically ill subject. Anaesth Intensive Care 25:250–254PubMed
Metadata
Title
Can dynamic indicators help the prediction of fluid responsiveness in spontaneously breathing critically ill patients?
Authors
Stéphane Soubrier
Fabienne Saulnier
Hervé Hubert
Pierre Delour
Hélène Lenci
Thierry Onimus
Saad Nseir
Alain Durocher
Publication date
01-07-2007
Publisher
Springer Berlin Heidelberg
Published in
Intensive Care Medicine / Issue 7/2007
Print ISSN: 0342-4642
Electronic ISSN: 1432-1238
DOI
https://doi.org/10.1007/s00134-007-0644-9

Other articles of this Issue 7/2007

Intensive Care Medicine 7/2007 Go to the issue

Mini-series: basic research-related topics in ICM

Alveolar epithelium and Na,K-ATPase in acute lung injury

Announcements

Announcements