Skip to main content
Top
Published in: Intensive Care Medicine 10/2005

01-10-2005 | Original

Stroke output variations calculated by esophageal Doppler is a reliable predictor of fluid response

Authors: Fabrice Vallée, Olivier Fourcade, Olivier De Soyres, Olivier Angles, Pascale Sanchez-Verlaan, Fabien Pillard, Nadia Smail, Michel Olivier, Michèle Genestal, Kamran Samii

Published in: Intensive Care Medicine | Issue 10/2005

Login to get access

Abstract

Objective

Esophageal Doppler allows continuous monitoring of stroke volume index (SVI) and corrected flow time (FTc). We hypothesized that variations in stroke output index SOI (SVI/FTc) during volume expansion can predict the hemodynamic response to subsequent fluid loading better than the static values.

Design and setting

Prospective study in the intensive care unit of a university hospital.

Patients

Fifty-one patients with circulatory failure were monitored by esophageal Doppler.

Interventions

Patients who responded to a first fluid challenge received a second one. Patients who responded to both were classified as responders-responders, and those who did not respond to the second as responders-nonresponders. In these two groups we compared ΔSVI, ΔFTc, and ΔSOI during each fluid challenge and also static values at the end of each fluid challenge.

Measurements and results

After the first fluid challenge ΔSOI and ΔSVI were significantly higher in patients who responded to subsequent volume expansion than in patients who no longer responded. ROC curves showed that ΔSOI was a better predictor of fluid responsiveness than ΔSVI. During volume expansion a ΔSOI value of 11% discriminated between responders and nonresponders to subsequent volume expansion with a sensitivity of 91% and a specificity of 97%. There was no significant difference between the two groups for FTc value at the end of first fluid challenge.

Conclusions

Analysis of ΔSOI during fluid challenge predicts response to subsequent fluid challenge and FTc is not a reliable indicator of cardiac preload.
Literature
1.
go back to reference Dellinger RP, Carlet JM, Gerlach H, Ramsey G, Levy M (2004) Surviving sepsis campaign guidelines for management of severe sepsis and septic shock. Crit Care Med 32:858–873CrossRefPubMed Dellinger RP, Carlet JM, Gerlach H, Ramsey G, Levy M (2004) Surviving sepsis campaign guidelines for management of severe sepsis and septic shock. Crit Care Med 32:858–873CrossRefPubMed
2.
go back to reference Arieff AI (1999) Fatal postoperative pulmonary edema: pathogenesis and literature review. Chest 115:1371–1377CrossRefPubMed Arieff AI (1999) Fatal postoperative pulmonary edema: pathogenesis and literature review. Chest 115:1371–1377CrossRefPubMed
3.
go back to reference Michard F, Boussat S, Chemla D, Anguel N, Mercat A, Lecarpentier Y, Richard C, Pinsky MR, Teboul JL (2000) Relation between respiratory changes in arterial pulse pressure and fluid responsiveness in septic patients with acute circulatory failure. Am J Respir Crit Care Med 162:134–138PubMed Michard F, Boussat S, Chemla D, Anguel N, Mercat A, Lecarpentier Y, Richard C, Pinsky MR, Teboul JL (2000) Relation between respiratory changes in arterial pulse pressure and fluid responsiveness in septic patients with acute circulatory failure. Am J Respir Crit Care Med 162:134–138PubMed
4.
go back to reference Slama M, Masson H, Teboul JL, Arnould ML, Nait-Kaoudjt R, Colas B, Peltier M, Tribouilloy C, Susic D, Frohlich E, Andrejak M (2004) Monitoring of respiratory variations of aortic blood flow velocity using esophageal Doppler. Intensive Care Med 30:1182–1187PubMed Slama M, Masson H, Teboul JL, Arnould ML, Nait-Kaoudjt R, Colas B, Peltier M, Tribouilloy C, Susic D, Frohlich E, Andrejak M (2004) Monitoring of respiratory variations of aortic blood flow velocity using esophageal Doppler. Intensive Care Med 30:1182–1187PubMed
5.
go back to reference Slama M, Masson H, Teboul JL, Arnout ML, Susic D, Frohlich E, Andrejak M (2002) Respiratory variations of aortic VTI: a new index of hypovolemia and fluid responsiveness. Am J Physiol Heart Circ Physiol 283:1729–1733 Slama M, Masson H, Teboul JL, Arnout ML, Susic D, Frohlich E, Andrejak M (2002) Respiratory variations of aortic VTI: a new index of hypovolemia and fluid responsiveness. Am J Physiol Heart Circ Physiol 283:1729–1733
6.
go back to reference Feissel M, Michard F, Mangin I, Ruyer O, Faller JP, Teboul JL (2001) Respiratory changes in aortic blood velocity as an indicator of fluid responsiveness in ventilated patients with septic shock. Chest 119:867–873CrossRefPubMed Feissel M, Michard F, Mangin I, Ruyer O, Faller JP, Teboul JL (2001) Respiratory changes in aortic blood velocity as an indicator of fluid responsiveness in ventilated patients with septic shock. Chest 119:867–873CrossRefPubMed
7.
go back to reference Reuter DA, Kirchner A, Felbinger TW, Weis FC, Kilger E, Lamm P, Goetz AE (2003) Usefulness of left ventricular stroke volume variation to assess fluid responsiveness in patients with reduced cardiac function. Crit Care Med 31:1399–1404CrossRefPubMed Reuter DA, Kirchner A, Felbinger TW, Weis FC, Kilger E, Lamm P, Goetz AE (2003) Usefulness of left ventricular stroke volume variation to assess fluid responsiveness in patients with reduced cardiac function. Crit Care Med 31:1399–1404CrossRefPubMed
8.
go back to reference Reuter DA, Felbinger TW, Schmidt C, Kilger E, Goedje O, Lamm P, Goetz AE (2002) Volume variations for assessment of cardiac responsiveness to volume loading in mechanically ventilated patients after cardiac surgery. Intensive Care Med 28:392–398CrossRefPubMed Reuter DA, Felbinger TW, Schmidt C, Kilger E, Goedje O, Lamm P, Goetz AE (2002) Volume variations for assessment of cardiac responsiveness to volume loading in mechanically ventilated patients after cardiac surgery. Intensive Care Med 28:392–398CrossRefPubMed
9.
go back to reference Krishnamurthy B, McMurray TJ, McClean E (1997) The peri-operative use of the oesophageal Doppler monitor in patients undergoing coronary artery revascularisation. A comparison with the continuous cardiac output monitor. Anaesthesia 52:624–629CrossRefPubMed Krishnamurthy B, McMurray TJ, McClean E (1997) The peri-operative use of the oesophageal Doppler monitor in patients undergoing coronary artery revascularisation. A comparison with the continuous cardiac output monitor. Anaesthesia 52:624–629CrossRefPubMed
10.
go back to reference Leone D, Servillo G, De Robertis E, Rossano F, Tufano R (1998) Monitoring cardiac output: esophageal doppler vs thermodilution. Minerva Anestesiol 64:351–356PubMed Leone D, Servillo G, De Robertis E, Rossano F, Tufano R (1998) Monitoring cardiac output: esophageal doppler vs thermodilution. Minerva Anestesiol 64:351–356PubMed
11.
go back to reference Baillard C, Cohen Y, Fosse JP, Karoubi P, Hoang P, Cupa M (1999) Haemodynamic measurements (continuous cardiac output and systemic vascular resistance) in critically ill patients: transoesophageal Doppler versus continuous thermodilution. Anaesth Intensive Care 27:33–37PubMed Baillard C, Cohen Y, Fosse JP, Karoubi P, Hoang P, Cupa M (1999) Haemodynamic measurements (continuous cardiac output and systemic vascular resistance) in critically ill patients: transoesophageal Doppler versus continuous thermodilution. Anaesth Intensive Care 27:33–37PubMed
12.
go back to reference Keyl C, Rodig G, Lemberger P, Hobbhahn J (1996) A comparison of the use of transoesophageal Doppler and thermodilution techniques for cardiac output determination. Eur J Anaesthesiol 13:136–142CrossRefPubMed Keyl C, Rodig G, Lemberger P, Hobbhahn J (1996) A comparison of the use of transoesophageal Doppler and thermodilution techniques for cardiac output determination. Eur J Anaesthesiol 13:136–142CrossRefPubMed
13.
go back to reference Sinclair S, James S, Singer M (1997) Intraoperative intravascular volume optimisation and length of hospital stay after repair of proximal femoral fracture: randomised controlled trial. BMJ 315:909–912PubMed Sinclair S, James S, Singer M (1997) Intraoperative intravascular volume optimisation and length of hospital stay after repair of proximal femoral fracture: randomised controlled trial. BMJ 315:909–912PubMed
14.
go back to reference Conway DH, Mayall R, Abdul-Latif MS, Gilligan S, Tackaberry C (2002) Randomised controlled trial investigating the influence of intravenous fluid titration using oesophageal Doppler monitoring during bowel surgery. Anaesthesia 57:845–849CrossRefPubMed Conway DH, Mayall R, Abdul-Latif MS, Gilligan S, Tackaberry C (2002) Randomised controlled trial investigating the influence of intravenous fluid titration using oesophageal Doppler monitoring during bowel surgery. Anaesthesia 57:845–849CrossRefPubMed
15.
go back to reference Venn R, Steele A, Richardson P, Poloniecki J, Grounds M, Newman P (2002) Randomized controlled trial to investigate influence of the fluid challenge on duration of hospital stay and perioperative morbidity in patients with hip fractures. Br J Anaesth 88:65–71CrossRefPubMed Venn R, Steele A, Richardson P, Poloniecki J, Grounds M, Newman P (2002) Randomized controlled trial to investigate influence of the fluid challenge on duration of hospital stay and perioperative morbidity in patients with hip fractures. Br J Anaesth 88:65–71CrossRefPubMed
16.
go back to reference Gan TJ, Soppitt A, Maroof M, El Moalem H, Robertson KM, Moretti E, Dwane P, Glass PS (2002) Goal-directed intraoperative fluid administration reduces length of hospital stay after major surgery. Anesthesiology 97:820–826CrossRefPubMed Gan TJ, Soppitt A, Maroof M, El Moalem H, Robertson KM, Moretti E, Dwane P, Glass PS (2002) Goal-directed intraoperative fluid administration reduces length of hospital stay after major surgery. Anesthesiology 97:820–826CrossRefPubMed
17.
go back to reference American College of Chest Physicians/Society of Critical Care Medicine Consensus Conference (1992) Definitions for sepsis and organ failure and guidelines for the use of innovative therapies in sepsis. Crit Care Med 20:864–874PubMed American College of Chest Physicians/Society of Critical Care Medicine Consensus Conference (1992) Definitions for sepsis and organ failure and guidelines for the use of innovative therapies in sepsis. Crit Care Med 20:864–874PubMed
18.
go back to reference Legall J, Lemeshow S, Saulnier F (1993) New Simplified Acute Physiology Score (SAPS II) based on a European/North American Multicenter Study. JAMA 270:2957–2963PubMed Legall J, Lemeshow S, Saulnier F (1993) New Simplified Acute Physiology Score (SAPS II) based on a European/North American Multicenter Study. JAMA 270:2957–2963PubMed
19.
go back to reference Hanley JA, McNeil BJ (1983) A method of comparing the areas under receiver operating characteristic curves derived from the same cases. Radiology 148:839–843PubMed Hanley JA, McNeil BJ (1983) A method of comparing the areas under receiver operating characteristic curves derived from the same cases. Radiology 148:839–843PubMed
20.
go back to reference Madan AK, UyBarreta VV, Aliabadi-Wahle S, Jesperson R, Hartz RS, Flint LM, Steinberg SM (1999) Esophageal Doppler ultrasound monitor versus pulmonary artery catheter in the hemodynamic management of critically ill surgical patients. J Trauma 46:607–611PubMed Madan AK, UyBarreta VV, Aliabadi-Wahle S, Jesperson R, Hartz RS, Flint LM, Steinberg SM (1999) Esophageal Doppler ultrasound monitor versus pulmonary artery catheter in the hemodynamic management of critically ill surgical patients. J Trauma 46:607–611PubMed
21.
go back to reference DiCorte CJ, Latham P, Greilich PE, Cooley MV, Grayburn PA, Jessen ME (2000) Esophageal Doppler monitor determinations of cardiac output and preload during cardiac operations. Ann Thorac Surg 69:1782–1786CrossRefPubMed DiCorte CJ, Latham P, Greilich PE, Cooley MV, Grayburn PA, Jessen ME (2000) Esophageal Doppler monitor determinations of cardiac output and preload during cardiac operations. Ann Thorac Surg 69:1782–1786CrossRefPubMed
22.
go back to reference Michard F, Teboul JL (2002) Predicting fluid responsiveness in ICU patients: a critical analysis of the evidence. Chest 121:2000–2008CrossRefPubMed Michard F, Teboul JL (2002) Predicting fluid responsiveness in ICU patients: a critical analysis of the evidence. Chest 121:2000–2008CrossRefPubMed
23.
go back to reference Lefrant JY, Bruelle P, Aya AG, Saissi G, Dauzat M, de La Coussaye JE, Eledjam JJ (1998) Training is required to improve the reliability of esophageal Doppler to measure cardiac output in critically ill patients. Intensive Care Med 24:347–352CrossRefPubMed Lefrant JY, Bruelle P, Aya AG, Saissi G, Dauzat M, de La Coussaye JE, Eledjam JJ (1998) Training is required to improve the reliability of esophageal Doppler to measure cardiac output in critically ill patients. Intensive Care Med 24:347–352CrossRefPubMed
Metadata
Title
Stroke output variations calculated by esophageal Doppler is a reliable predictor of fluid response
Authors
Fabrice Vallée
Olivier Fourcade
Olivier De Soyres
Olivier Angles
Pascale Sanchez-Verlaan
Fabien Pillard
Nadia Smail
Michel Olivier
Michèle Genestal
Kamran Samii
Publication date
01-10-2005
Publisher
Springer-Verlag
Published in
Intensive Care Medicine / Issue 10/2005
Print ISSN: 0342-4642
Electronic ISSN: 1432-1238
DOI
https://doi.org/10.1007/s00134-005-2768-0

Other articles of this Issue 10/2005

Intensive Care Medicine 10/2005 Go to the issue