Use of local pro-coagulant haemostatic agents for intra-cavity control of haemorrhage after trauma

Authors: A. Navarro, A. Brooks

Published in: European Journal of Trauma and Emergency Surgery | Issue 5/2015

Login to get access

Abstract

Introduction

Uncontrolled haemorrhage as a result of trauma remains a significant surgical challenge, accounting for approximately 25–40 % of trauma-related mortality. A wide range of local internal haemostatic agents have been developed to help achieve intra-cavity control of bleeding, with choice of agent influenced by the circumstances and nature of the haemorrhage. Trauma patients are frequently coagulopathic, so products that incorporate pro-coagulant technology and thereby act independently of the clotting cascade may be more effective in these settings. A range of products that utilise thrombin and fibrinogen to promote local haemostasis at intra-cavity bleeding points are available or in development, including fibrin glues (e.g. Tisseel®/Tissucol® and Evicel®/Crosseal®/Quixil®), fibrin sealant patches (e.g. TachoSil®) and products based on a gelatin-thrombin haemostatic matrix (e.g. FloSeal®).

Materials and methods

This systematic review was performed to assess all peer-reviewed evidence of product efficacy.

Results

Fibrin sealant patches have shown haemostatic efficacy in a variety of surgical procedures and appear to offer practical advantages over liquid fibrin glues. Existing evidence suggests that patch products enable delivery of pro-coagulants to defined areas with less chance of dilution and/or displacement by blood flow, but they require a pressure buttress for a suitable amount of time to achieve good results after trauma.

Conclusions

Our experience, supported by other reports in the literature, suggests the use of such fibrin patches may provide an effective option in helping to control haemorrhage after trauma. However, there is a general paucity of clinical data for intra-cavity haemostatic agent use, with the majority of data being based on animal models and case reports. Further clinical evidence, ideally including comparative studies between different agents, would be beneficial in helping guide surgeon choice to the most appropriate products to use in trauma settings.
Literature
1.
go back to reference Søreide K, Krüger AJ, Vårdal AL, Ellingsen CL, Søreide E, Lossius HM. Epidemiology and contemporary patterns of trauma deaths: changing place, similar pace, older face. World J Surg. 2007;31:2092–103.CrossRefPubMed Søreide K, Krüger AJ, Vårdal AL, Ellingsen CL, Søreide E, Lossius HM. Epidemiology and contemporary patterns of trauma deaths: changing place, similar pace, older face. World J Surg. 2007;31:2092–103.CrossRefPubMed
2.
go back to reference Chalkley D, Cheung G, Walsh M, Tai N. Deaths from trauma in London—a single centre experience. Emerg Med J. 2011;28:305–9.CrossRefPubMed Chalkley D, Cheung G, Walsh M, Tai N. Deaths from trauma in London—a single centre experience. Emerg Med J. 2011;28:305–9.CrossRefPubMed
4.
go back to reference Waibel BH, Rotondo MF. Damage control in trauma and abdominal sepsis. Crit Care Med. 2010;38(Suppl):S421–30.CrossRefPubMed Waibel BH, Rotondo MF. Damage control in trauma and abdominal sepsis. Crit Care Med. 2010;38(Suppl):S421–30.CrossRefPubMed
5.
go back to reference Bowley DM, Barker P, Boffard KD. Damage control surgery—concepts and practice. J R Army Med Corps. 2000;146:176–82.CrossRefPubMed Bowley DM, Barker P, Boffard KD. Damage control surgery—concepts and practice. J R Army Med Corps. 2000;146:176–82.CrossRefPubMed
6.
go back to reference Tapia NM, Suliburk J, Mattox KL. The initial trauma center fluid management of penetrating injury: a systematic review. Clin Orthop Relat Res. 2013;471(12):3961–73.PubMedCentralCrossRefPubMed Tapia NM, Suliburk J, Mattox KL. The initial trauma center fluid management of penetrating injury: a systematic review. Clin Orthop Relat Res. 2013;471(12):3961–73.PubMedCentralCrossRefPubMed
8.
go back to reference Granville-Chapman J, Jacobs N, Midwinter MJ. Pre-hospital haemostatic dressings: a systematic review. Injury. 2011;42:447–59.CrossRefPubMed Granville-Chapman J, Jacobs N, Midwinter MJ. Pre-hospital haemostatic dressings: a systematic review. Injury. 2011;42:447–59.CrossRefPubMed
10.
go back to reference Seyednejad H, Imani M, Jamieson T, Seifalian AM. Topical haemostatic agents. Br J Surg. 2008;95:1197–225.CrossRefPubMed Seyednejad H, Imani M, Jamieson T, Seifalian AM. Topical haemostatic agents. Br J Surg. 2008;95:1197–225.CrossRefPubMed
11.
go back to reference Canonico S, Sciaudone G, Pacifico F, Santoriello A. Inguinal hernia repair in patients with coagulation problems: prevention of postoperative bleeding with human fibrin glue. Surgery. 1999;125:315–7.CrossRefPubMed Canonico S, Sciaudone G, Pacifico F, Santoriello A. Inguinal hernia repair in patients with coagulation problems: prevention of postoperative bleeding with human fibrin glue. Surgery. 1999;125:315–7.CrossRefPubMed
12.
go back to reference Walshe P, Harkin C, Murphy S, Shah C, Curran A, McShane D. The use of fibrin glue in refractory coagulopathic epistaxis. Clin Otolaryngol Allied Sci. 2001;26:284–5.CrossRefPubMed Walshe P, Harkin C, Murphy S, Shah C, Curran A, McShane D. The use of fibrin glue in refractory coagulopathic epistaxis. Clin Otolaryngol Allied Sci. 2001;26:284–5.CrossRefPubMed
13.
go back to reference Codispoti M, Mankad PS. Significant merits of a fibrin sealant in the presence of coagulopathy following paediatric cardiac surgery: randomised controlled trial. Eur J Cardiothorac Surg. 2002;22:200–5.CrossRefPubMed Codispoti M, Mankad PS. Significant merits of a fibrin sealant in the presence of coagulopathy following paediatric cardiac surgery: randomised controlled trial. Eur J Cardiothorac Surg. 2002;22:200–5.CrossRefPubMed
14.
go back to reference Ochsner MG, Maniscalco-Theberge ME, Champion HR. Fibrin glue as a hemostatic agent in hepatic and splenic trauma. J Trauma. 1990;30:884–7.CrossRefPubMed Ochsner MG, Maniscalco-Theberge ME, Champion HR. Fibrin glue as a hemostatic agent in hepatic and splenic trauma. J Trauma. 1990;30:884–7.CrossRefPubMed
15.
go back to reference Kheirabadi BS, Field-Ridley A, Pearson R, MacPhee M, Drohan W, Tuthill D. Comparative study of the efficacy of the common topical hemostatic agents with fibrin sealant in a rabbit aortic anastomosis model. J Surg Res. 2002;106:99–107.CrossRefPubMed Kheirabadi BS, Field-Ridley A, Pearson R, MacPhee M, Drohan W, Tuthill D. Comparative study of the efficacy of the common topical hemostatic agents with fibrin sealant in a rabbit aortic anastomosis model. J Surg Res. 2002;106:99–107.CrossRefPubMed
17.
go back to reference Frilling A, Stavrou GA, Mischinger HJ, de Hemptinne B, Rokkjaer M, Klempnauer J, et al. Effectiveness of a new carrier-bound fibrin sealant versus argon beamer as haemostatic agent during liver resection: a randomised prospective trial. Langenbecks Arch Surg. 2005;390:114–20.CrossRefPubMed Frilling A, Stavrou GA, Mischinger HJ, de Hemptinne B, Rokkjaer M, Klempnauer J, et al. Effectiveness of a new carrier-bound fibrin sealant versus argon beamer as haemostatic agent during liver resection: a randomised prospective trial. Langenbecks Arch Surg. 2005;390:114–20.CrossRefPubMed
18.
go back to reference Siemer S, Lahme S, Altziebler S, Machtens S, Strohmaier W, Wechsel HW, et al. Efficacy and safety of TachoSil as haemostatic treatment versus standard suturing in kidney tumour resection: a randomised prospective study. Eur Urol. 2007;52:1156–63.CrossRefPubMed Siemer S, Lahme S, Altziebler S, Machtens S, Strohmaier W, Wechsel HW, et al. Efficacy and safety of TachoSil as haemostatic treatment versus standard suturing in kidney tumour resection: a randomised prospective study. Eur Urol. 2007;52:1156–63.CrossRefPubMed
19.
go back to reference Maisano F, Kjaergård HK, Bauernschmitt R, Pavie A, Rábago G, Laskar M, et al. TachoSil surgical patch versus conventional haemostatic fleece material for control of bleeding in cardiovascular surgery: a randomised controlled trial. Eur J Cardiothorac Surg. 2009;36(4):708–14.CrossRefPubMed Maisano F, Kjaergård HK, Bauernschmitt R, Pavie A, Rábago G, Laskar M, et al. TachoSil surgical patch versus conventional haemostatic fleece material for control of bleeding in cardiovascular surgery: a randomised controlled trial. Eur J Cardiothorac Surg. 2009;36(4):708–14.CrossRefPubMed
20.
go back to reference Marta GM, Facciolo F, Ladegaard L, Dienemann H, Csekeo A, Rea F, et al. Efficacy and safety of TachoSil® versus standard treatment of air leakage after pulmonary lobectomy. Eur J Cardiothorac Surg. 2010;38:683–9.CrossRefPubMed Marta GM, Facciolo F, Ladegaard L, Dienemann H, Csekeo A, Rea F, et al. Efficacy and safety of TachoSil® versus standard treatment of air leakage after pulmonary lobectomy. Eur J Cardiothorac Surg. 2010;38:683–9.CrossRefPubMed
21.
go back to reference Fischer L, Seiler CM, Broelsch CE, de Hemptinne B, Klempnauer J, Mischinger HJ, et al. Hemostatic efficacy of TachoSil in liver resection compared with argon beam coagulator treatment: an open, randomized, prospective, multicenter, parallel-group trial. Surgery. 2011;149:48–55.CrossRefPubMed Fischer L, Seiler CM, Broelsch CE, de Hemptinne B, Klempnauer J, Mischinger HJ, et al. Hemostatic efficacy of TachoSil in liver resection compared with argon beam coagulator treatment: an open, randomized, prospective, multicenter, parallel-group trial. Surgery. 2011;149:48–55.CrossRefPubMed
22.
go back to reference Rickenbacher A, Breitenstein S, Lesurtel M, Frilling A. Efficacy of TachoSil a fibrin-based haemostat in different fields of surgery—a systematic review. Expert Opin Biol Ther. 2009;9:897–907.CrossRefPubMed Rickenbacher A, Breitenstein S, Lesurtel M, Frilling A. Efficacy of TachoSil a fibrin-based haemostat in different fields of surgery—a systematic review. Expert Opin Biol Ther. 2009;9:897–907.CrossRefPubMed
23.
go back to reference Schiele U, Kuntz G, Riegler A. Haemostyptic preparations on the basis of collagen alone and as fixed combination with fibrin glue. Clin Mater. 1992;9:169–77.CrossRefPubMed Schiele U, Kuntz G, Riegler A. Haemostyptic preparations on the basis of collagen alone and as fixed combination with fibrin glue. Clin Mater. 1992;9:169–77.CrossRefPubMed
24.
go back to reference Carbon RT, Baar S, Kriegelstein S, Huemmer HP, Baar K, Simon SI. Evaluating the in vitro adhesive strength of biomaterials. Biosimulator for selective leak closure. Biomaterials. 2003;24:1469–75.CrossRefPubMed Carbon RT, Baar S, Kriegelstein S, Huemmer HP, Baar K, Simon SI. Evaluating the in vitro adhesive strength of biomaterials. Biosimulator for selective leak closure. Biomaterials. 2003;24:1469–75.CrossRefPubMed
25.
go back to reference Carbon R, Kriegelstein S, Baar S, Schmidt A, Weber P, Huemmer HP. Tissue management with fleece-bound sealing: Materials, material science and clinical implementation. In: Faist E, editor. 6th World Congress on Trauma, Shock, Inflammation and Sepsis: Pathophysiology, immune consequences and therapy. Bologne: Monduzzi Editore-Medimond; 2004. Carbon R, Kriegelstein S, Baar S, Schmidt A, Weber P, Huemmer HP. Tissue management with fleece-bound sealing: Materials, material science and clinical implementation. In: Faist E, editor. 6th World Congress on Trauma, Shock, Inflammation and Sepsis: Pathophysiology, immune consequences and therapy. Bologne: Monduzzi Editore-Medimond; 2004.
26.
go back to reference Grottke O, Braunschweig T, Daheim N, Coburn M, Grieb G, Rossaint R, et al. Effect of TachoSil in a coagulopathic pig model with blunt liver injuries. J Surg Res. 2011;171:234–9.CrossRefPubMed Grottke O, Braunschweig T, Daheim N, Coburn M, Grieb G, Rossaint R, et al. Effect of TachoSil in a coagulopathic pig model with blunt liver injuries. J Surg Res. 2011;171:234–9.CrossRefPubMed
27.
go back to reference Agger P, Langhoff J, Smerup MH, Hasenkam JM. Comparison between TachoComb and TachoSil for surgical hemostasis in arterial bleeding: an animal experimental study. J Trauma. 2010;68:838–42.CrossRefPubMed Agger P, Langhoff J, Smerup MH, Hasenkam JM. Comparison between TachoComb and TachoSil for surgical hemostasis in arterial bleeding: an animal experimental study. J Trauma. 2010;68:838–42.CrossRefPubMed
28.
go back to reference Frena A, Martin F. How to improve bilio-stasis in liver surgery. Chir Ital. 2006;58:793–5.PubMed Frena A, Martin F. How to improve bilio-stasis in liver surgery. Chir Ital. 2006;58:793–5.PubMed
29.
go back to reference Carbon RT, Baar S, Waldschmidt J, Huemmer HP, Simon SI. Innovative minimally invasive pediatric surgery is of therapeutic value for splenic injury. J Pediatr Surg. 2002;37:1146–50.CrossRefPubMed Carbon RT, Baar S, Waldschmidt J, Huemmer HP, Simon SI. Innovative minimally invasive pediatric surgery is of therapeutic value for splenic injury. J Pediatr Surg. 2002;37:1146–50.CrossRefPubMed
30.
go back to reference Brückner B. Biological tissue glues—an outline of personal experience with the preparation TachoComb. Int Rev Armed Forces Med Services. 1995;68(10–12):323–7. Brückner B. Biological tissue glues—an outline of personal experience with the preparation TachoComb. Int Rev Armed Forces Med Services. 1995;68(10–12):323–7.
31.
go back to reference Stannard A, Ramasamy A, Edwards D, Hinsley D, Midwinter M, Brooks A. Tachosil use on operational deployment. Presented at the Association of Military Surgeons, Military Surgery Conference, UK, 2009. Stannard A, Ramasamy A, Edwards D, Hinsley D, Midwinter M, Brooks A. Tachosil use on operational deployment. Presented at the Association of Military Surgeons, Military Surgery Conference, UK, 2009.
32.
go back to reference Larson MJ, Bowersox JC, Lim RC Jr, Hess JR. Efficacy of a fibrin hemostatic bandage in controlling hemorrhage from experimental arterial injuries. Arch Surg. 1995;130:420–2.CrossRefPubMed Larson MJ, Bowersox JC, Lim RC Jr, Hess JR. Efficacy of a fibrin hemostatic bandage in controlling hemorrhage from experimental arterial injuries. Arch Surg. 1995;130:420–2.CrossRefPubMed
33.
go back to reference Jackson MR, Friedman SA, Carter AJ, Bayer V, Burge JR, MacPhee MJ, et al. Hemostatic efficacy of a fibrin sealant-based topical agent in a femoral artery injury model: a randomized, blinded, placebo-controlled study. J Vasc Surg. 1997;26:274–80.CrossRefPubMed Jackson MR, Friedman SA, Carter AJ, Bayer V, Burge JR, MacPhee MJ, et al. Hemostatic efficacy of a fibrin sealant-based topical agent in a femoral artery injury model: a randomized, blinded, placebo-controlled study. J Vasc Surg. 1997;26:274–80.CrossRefPubMed
34.
go back to reference Holcomb JB, Pusateri AE, Hess JR, Hetz SP, Harris RA, Tock BB, et al. Implications of new dry fibrin sealant technology for trauma surgery. Surg Clin North Am. 1997;77:943–52.CrossRefPubMed Holcomb JB, Pusateri AE, Hess JR, Hetz SP, Harris RA, Tock BB, et al. Implications of new dry fibrin sealant technology for trauma surgery. Surg Clin North Am. 1997;77:943–52.CrossRefPubMed
35.
go back to reference Holcomb JB, Pusateri AE, Harris RA, Charles NC, Gomez RR, Cole JP, et al. Effect of dry fibrin sealant dressings versus gauze packing on blood loss in grade V liver injuries in resuscitated swine. J Trauma. 1999;46:49–57.CrossRefPubMed Holcomb JB, Pusateri AE, Harris RA, Charles NC, Gomez RR, Cole JP, et al. Effect of dry fibrin sealant dressings versus gauze packing on blood loss in grade V liver injuries in resuscitated swine. J Trauma. 1999;46:49–57.CrossRefPubMed
36.
go back to reference Pusateri AE, Modrow HE, Harris RA, Holcomb JB, Hess JR, Mosebar RH, et al. Advanced hemostatic dressing development program: animal model selection criteria and results of a study of nine hemostatic dressings in a model of severe large venous hemorrhage and hepatic injury in Swine. J Trauma. 2003;55:518–26.CrossRefPubMed Pusateri AE, Modrow HE, Harris RA, Holcomb JB, Hess JR, Mosebar RH, et al. Advanced hemostatic dressing development program: animal model selection criteria and results of a study of nine hemostatic dressings in a model of severe large venous hemorrhage and hepatic injury in Swine. J Trauma. 2003;55:518–26.CrossRefPubMed
37.
go back to reference Sondeen JL, Pusateri AE, Coppes VG, Gaddy CE, Holcomb JB. Comparison of 10 different hemostatic dressings in an aortic injury. J Trauma. 2003;54:280–5.CrossRefPubMed Sondeen JL, Pusateri AE, Coppes VG, Gaddy CE, Holcomb JB. Comparison of 10 different hemostatic dressings in an aortic injury. J Trauma. 2003;54:280–5.CrossRefPubMed
38.
go back to reference Kheirabadi BS, Acheson EM, Deguzman R, Sondeen JL, Ryan KL, Delgado A, et al. Hemostatic efficacy of two advanced dressings in an aortic hemorrhage model in Swine. J Trauma. 2005;59:25–34.CrossRefPubMed Kheirabadi BS, Acheson EM, Deguzman R, Sondeen JL, Ryan KL, Delgado A, et al. Hemostatic efficacy of two advanced dressings in an aortic hemorrhage model in Swine. J Trauma. 2005;59:25–34.CrossRefPubMed
39.
go back to reference McManus JG, Wedmore I. Modern hemostatic agents for hemorrhage control—a review and discussion of use in current combat operations. Emerg Med Review 2005;1–4. McManus JG, Wedmore I. Modern hemostatic agents for hemorrhage control—a review and discussion of use in current combat operations. Emerg Med Review 2005;1–4.
40.
go back to reference Delgado AV, Kheirabadi BS, Fruchterman TM, Scherer M, Cortez D, Wade CE, et al. A novel biologic hemostatic dressing (fibrin patch) reduces blood loss and resuscitation volume and improves survival in hypothermic, coagulopathic Swine with grade V liver injury. J Trauma. 2008;64:75–80.CrossRefPubMed Delgado AV, Kheirabadi BS, Fruchterman TM, Scherer M, Cortez D, Wade CE, et al. A novel biologic hemostatic dressing (fibrin patch) reduces blood loss and resuscitation volume and improves survival in hypothermic, coagulopathic Swine with grade V liver injury. J Trauma. 2008;64:75–80.CrossRefPubMed
41.
go back to reference Floyd CT, Rothwell SW, Martin R, Risdahl J, Olson CE. A salmon thrombin-fibrinogen dressing controls hemorrhage in a swine model compared to standard kaolin-coated gauze. J Spec Oper Med. 2012;12:49–55.PubMed Floyd CT, Rothwell SW, Martin R, Risdahl J, Olson CE. A salmon thrombin-fibrinogen dressing controls hemorrhage in a swine model compared to standard kaolin-coated gauze. J Spec Oper Med. 2012;12:49–55.PubMed
42.
go back to reference Floyd CT, Rothwell SW, Risdahl J, Martin R, Olson C, Rose N. Salmon thrombin-fibrinogen dressing allows greater survival and preserves distal blood flow compared to standard kaolin gauze in coagulopathic swine with a standardized lethal femoral artery injury. J Spec Oper Med. 2012;12:16–26.PubMed Floyd CT, Rothwell SW, Risdahl J, Martin R, Olson C, Rose N. Salmon thrombin-fibrinogen dressing allows greater survival and preserves distal blood flow compared to standard kaolin gauze in coagulopathic swine with a standardized lethal femoral artery injury. J Spec Oper Med. 2012;12:16–26.PubMed
43.
go back to reference Koea JB, Batiller J, Patel B, Shen J, Hammond J, Hart J, et al. A phase III, randomized, controlled, superiority trial evaluating the fibrin pad versus standard of care in controlling parenchymal bleeding during elective hepatic surgery. HPB (Oxford). 2013;15:61–70.CrossRef Koea JB, Batiller J, Patel B, Shen J, Hammond J, Hart J, et al. A phase III, randomized, controlled, superiority trial evaluating the fibrin pad versus standard of care in controlling parenchymal bleeding during elective hepatic surgery. HPB (Oxford). 2013;15:61–70.CrossRef
44.
go back to reference Fischer CP, Bochicchio G, Shen J, Patel B, Batiller J, Hart JC. A prospective, randomized, controlled trial of the efficacy and safety of fibrin pad as an adjunct to control soft tissue bleeding during abdominal, retroperitoneal, pelvic, and thoracic surgery. J Am Coll Surg. 2013;217:385–93.CrossRefPubMed Fischer CP, Bochicchio G, Shen J, Patel B, Batiller J, Hart JC. A prospective, randomized, controlled trial of the efficacy and safety of fibrin pad as an adjunct to control soft tissue bleeding during abdominal, retroperitoneal, pelvic, and thoracic surgery. J Am Coll Surg. 2013;217:385–93.CrossRefPubMed
45.
go back to reference Ollinger R, Mihaljevic AL, Schuhmacher C, Bektas H, Vondran F, Kleine M, et al. A multicentre, randomized clinical trial comparing the Veriset™ haemostatic patch with fibrin sealant for the management of bleeding during hepatic surgery. HPB (Oxford). 2013;15:548–58.CrossRef Ollinger R, Mihaljevic AL, Schuhmacher C, Bektas H, Vondran F, Kleine M, et al. A multicentre, randomized clinical trial comparing the Veriset™ haemostatic patch with fibrin sealant for the management of bleeding during hepatic surgery. HPB (Oxford). 2013;15:548–58.CrossRef
46.
go back to reference Oz MC, Cosgrove DM 3rd, Badduke BR, Hill JD, Flannery MR, Palumbo R, et al. Controlled clinical trial of a novel hemostatic agent in cardiac surgery. The Fusion Matrix Study Group. Ann Thorac Surg. 2000;69:1376–82.CrossRefPubMed Oz MC, Cosgrove DM 3rd, Badduke BR, Hill JD, Flannery MR, Palumbo R, et al. Controlled clinical trial of a novel hemostatic agent in cardiac surgery. The Fusion Matrix Study Group. Ann Thorac Surg. 2000;69:1376–82.CrossRefPubMed
47.
go back to reference Weaver FA, Hood DB, Zatina M, Messina L, Badduke B. Gelatin-thrombin-based hemostatic sealant for intraoperative bleeding in vascular surgery. Ann Vasc Surg. 2002;16:286–93.CrossRefPubMed Weaver FA, Hood DB, Zatina M, Messina L, Badduke B. Gelatin-thrombin-based hemostatic sealant for intraoperative bleeding in vascular surgery. Ann Vasc Surg. 2002;16:286–93.CrossRefPubMed
48.
go back to reference Renkens KL Jr, Payner TD, Leipzig TJ, Feuer H, Morone MA, Koers JM, et al. A multicenter, prospective, randomized trial evaluating a new hemostatic agent for spinal surgery. Spine. 2001;26:1645–50.CrossRefPubMed Renkens KL Jr, Payner TD, Leipzig TJ, Feuer H, Morone MA, Koers JM, et al. A multicenter, prospective, randomized trial evaluating a new hemostatic agent for spinal surgery. Spine. 2001;26:1645–50.CrossRefPubMed
49.
go back to reference Gall RM, Witterick IJ, Shargill NS, Hawke M. Control of bleeding in endoscopic sinus surgery: use of a novel gelatin-based hemostatic agent. J Otolaryngol. 2002;31:271–4.CrossRefPubMed Gall RM, Witterick IJ, Shargill NS, Hawke M. Control of bleeding in endoscopic sinus surgery: use of a novel gelatin-based hemostatic agent. J Otolaryngol. 2002;31:271–4.CrossRefPubMed
50.
go back to reference Mathiasen RA, Cruz RM. Prospective, randomized, controlled clinical trial of a novel matrix hemostatic sealant in patients with acute anterior epistaxis. Laryngoscope. 2005;115:899–902.CrossRefPubMed Mathiasen RA, Cruz RM. Prospective, randomized, controlled clinical trial of a novel matrix hemostatic sealant in patients with acute anterior epistaxis. Laryngoscope. 2005;115:899–902.CrossRefPubMed
51.
go back to reference Pursifull NF, Morris MS, Harris RA, Morey AF. Damage control management of experimental grade 5 renal injuries: further evaluation of FloSeal gelatin matrix. J Trauma. 2006;60:346–50.CrossRefPubMed Pursifull NF, Morris MS, Harris RA, Morey AF. Damage control management of experimental grade 5 renal injuries: further evaluation of FloSeal gelatin matrix. J Trauma. 2006;60:346–50.CrossRefPubMed
52.
go back to reference Hick EJ, Morey AF, Harris RA, Morris MS. Gelatin matrix treatment of complex renal injuries in a porcine model. J Urol. 2005;173:1801–4.CrossRefPubMed Hick EJ, Morey AF, Harris RA, Morris MS. Gelatin matrix treatment of complex renal injuries in a porcine model. J Urol. 2005;173:1801–4.CrossRefPubMed
53.
go back to reference Leixnering M, Reichetseder J, Schultz A, Figl M, Wassermann E, Thurnher M, et al. Gelatin thrombin granules for hemostasis in a severe traumatic liver and spleen rupture model in swine. J Trauma. 2008;64:456–61.CrossRefPubMed Leixnering M, Reichetseder J, Schultz A, Figl M, Wassermann E, Thurnher M, et al. Gelatin thrombin granules for hemostasis in a severe traumatic liver and spleen rupture model in swine. J Trauma. 2008;64:456–61.CrossRefPubMed
54.
go back to reference Woodworth BA, Chandra RK, LeBenger JD, Ilie B, Schlosser RJ. A gelatin-thrombin matrix for hemostasis after endoscopic sinus surgery. Am J Otolaryngol. 2009;30:49–53.CrossRefPubMed Woodworth BA, Chandra RK, LeBenger JD, Ilie B, Schlosser RJ. A gelatin-thrombin matrix for hemostasis after endoscopic sinus surgery. Am J Otolaryngol. 2009;30:49–53.CrossRefPubMed
55.
go back to reference Lewis KM, Atlee HD, Mannone AJ, Dwyer J, Lin L, Goppelt A, et al. Comparison of two gelatin and thrombin combination hemostats in a porcine liver abrasion model. J Invest Surg. 2013;26:141–8.PubMedCentralCrossRefPubMed Lewis KM, Atlee HD, Mannone AJ, Dwyer J, Lin L, Goppelt A, et al. Comparison of two gelatin and thrombin combination hemostats in a porcine liver abrasion model. J Invest Surg. 2013;26:141–8.PubMedCentralCrossRefPubMed
56.
go back to reference Prior JJ, Wallace DG, Harner A, Powers N. A sprayable hemostat containing fibrillar collagen, bovine thrombin, and autologous plasma. Ann Thorac Surg. 1999;68:479–85.CrossRefPubMed Prior JJ, Wallace DG, Harner A, Powers N. A sprayable hemostat containing fibrillar collagen, bovine thrombin, and autologous plasma. Ann Thorac Surg. 1999;68:479–85.CrossRefPubMed
57.
go back to reference Turner AS, Parker D, Egbert B, Maroney M, Armstrong R, Powers N. Evaluation of a novel hemostatic device in an ovine parenchymal organ bleeding model of normal and impaired hemostasis. J Biomed Mater Res. 2002;63:37–47.CrossRefPubMed Turner AS, Parker D, Egbert B, Maroney M, Armstrong R, Powers N. Evaluation of a novel hemostatic device in an ovine parenchymal organ bleeding model of normal and impaired hemostasis. J Biomed Mater Res. 2002;63:37–47.CrossRefPubMed
58.
go back to reference CoStasis Multi-center Collaborative Writing Committee. A novel collagen-based composite offers effective hemostasis for multiple surgical indications: Results of a randomized controlled trial. Surgery. 2001;129:445–50.CrossRef CoStasis Multi-center Collaborative Writing Committee. A novel collagen-based composite offers effective hemostasis for multiple surgical indications: Results of a randomized controlled trial. Surgery. 2001;129:445–50.CrossRef
59.
go back to reference Chapman WC, Clavien PA, Fung J, Khanna A, Bonham A. Effective control of hepatic bleeding with a novel collagen-based composite combined with autologous plasma: results of a randomized controlled trial. Arch Surg. 2000;135:1200–4.CrossRefPubMed Chapman WC, Clavien PA, Fung J, Khanna A, Bonham A. Effective control of hepatic bleeding with a novel collagen-based composite combined with autologous plasma: results of a randomized controlled trial. Arch Surg. 2000;135:1200–4.CrossRefPubMed
60.
go back to reference Dunne JR, Bochicchio GV, Scalea TM. A novel approach to the treatment of gunshot injuries to the sacrum. Am Surg. 2003;69:91–4.PubMed Dunne JR, Bochicchio GV, Scalea TM. A novel approach to the treatment of gunshot injuries to the sacrum. Am Surg. 2003;69:91–4.PubMed
61.
go back to reference Bloomfield MR, Klika AK, Molloy RM, Froimson MI, Krebs VE, Barsoum WK. Prospective randomized evaluation of a collagen/thrombin and autologous platelet hemostatic agent during total knee arthroplasty. J Arthroplast. 2012;27:695–702.CrossRef Bloomfield MR, Klika AK, Molloy RM, Froimson MI, Krebs VE, Barsoum WK. Prospective randomized evaluation of a collagen/thrombin and autologous platelet hemostatic agent during total knee arthroplasty. J Arthroplast. 2012;27:695–702.CrossRef
62.
go back to reference Hauser CJ, Boffard K, Dutton R, Bernard GR, Croce MA, Holcomb JB, et al. Results of the CONTROL trial: efficacy and safety of recombinant activated Factor VII in the management of refractory traumatic hemorrhage. J Trauma. 2010;69:489–500.CrossRefPubMed Hauser CJ, Boffard K, Dutton R, Bernard GR, Croce MA, Holcomb JB, et al. Results of the CONTROL trial: efficacy and safety of recombinant activated Factor VII in the management of refractory traumatic hemorrhage. J Trauma. 2010;69:489–500.CrossRefPubMed
Metadata
Title
Use of local pro-coagulant haemostatic agents for intra-cavity control of haemorrhage after trauma
Authors
A. Navarro
A. Brooks
Publication date
01-10-2015
Publisher
Springer Berlin Heidelberg
Published in
European Journal of Trauma and Emergency Surgery / Issue 5/2015
Print ISSN: 1863-9933
Electronic ISSN: 1863-9941
DOI
https://doi.org/10.1007/s00068-014-0441-4

Other articles of this Issue 5/2015

European Journal of Trauma and Emergency Surgery 5/2015 Go to the issue

ESTES News 5.2015

ESTES News 5.2015