Skip to main content
Top
Published in: European Journal of Trauma and Emergency Surgery 1/2012

01-02-2012 | Original Article

Biomechanical comparison of two locking plate systems for the distal tibia

Authors: F. Högel, S. Hoffmann, P. Weninger, V. Bühren, P. Augat

Published in: European Journal of Trauma and Emergency Surgery | Issue 1/2012

Login to get access

Abstract

Background

Distal tibia fractures are known to be difficult to stabilize and nonunions often occur because of a relative instability of the fragments. Therefore, it was of interest to ascertain how different locking plates behave regarding stiffness and interfragmentary movement in comminuted distal tibia fractures.

Methods

A locked medial plate (AxSOS) for the medial distal tibia and a locked medial plate (LCP) for the distal medial tibia were compared biomechanically under compression and torsional load. The tibiae were osteotomized in distal intersection between 4/5 and 5/5, with a gap of 10 mm after instrumentation. For compression force, a load of 350 N was applied and for torsion, a torque of 0–10 Nm and back to 0 over −5-Nm intervals was performed. Stiffness was calculated from the machine data and interfragmentary movement was measured with an optoelectronic measurement device.

Results

Under compression load, the stiffness showed no significant differences between the AxSOS plate compared to the LCP. Significant differences were seen in the interfragmentary movement, where the LCP showed 1.03 mm compared to 0.6 mm for the AxSOS plate. In torsional testing, the AxSOS plate showed significantly higher stiffness than the LCP. The AxSOS plate and the LCP showed similar values for interfragmentary movement under torsional load.

Conclusion

The treatment of distal tibia fractures with angle-stable medial AxSOS plate showed less interfragmentary movement and higher stiffness than fracture fixation with a locked medial LCP. Even if there are no significant differences in torsional testing, plating of the distal tibia should be performed with a steel plate from the biomechanical view.
Literature
1.
go back to reference Hazarika S, Chakravarthy J, Cooper J. Minimally invasive locking plate osteosynthesis for fractures of the distal tibia—results in 20 patients. Injury. 2006;37(9):877–87.PubMedCrossRef Hazarika S, Chakravarthy J, Cooper J. Minimally invasive locking plate osteosynthesis for fractures of the distal tibia—results in 20 patients. Injury. 2006;37(9):877–87.PubMedCrossRef
2.
go back to reference Dai JP, Yan YQ, Yu YF, Zhou X. Curative effect comparison of two methods of treatment for distal tibial fractures. Zhongguo Gu Shang. 2009;22(5):361–3.PubMed Dai JP, Yan YQ, Yu YF, Zhou X. Curative effect comparison of two methods of treatment for distal tibial fractures. Zhongguo Gu Shang. 2009;22(5):361–3.PubMed
3.
go back to reference Bahari S, Lenehan B, Khan H, McElwain JP. Minimally invasive percutaneous plate fixation of distal tibia fractures. Acta Orthop Belg. 2007;73(5):635–40.PubMed Bahari S, Lenehan B, Khan H, McElwain JP. Minimally invasive percutaneous plate fixation of distal tibia fractures. Acta Orthop Belg. 2007;73(5):635–40.PubMed
4.
go back to reference Yamaji T, Ando K, Wolf S, Augat P, Claes L. The effect of micromovement on callus formation. J Orthop Sci. 2001;6:571–5.PubMedCrossRef Yamaji T, Ando K, Wolf S, Augat P, Claes L. The effect of micromovement on callus formation. J Orthop Sci. 2001;6:571–5.PubMedCrossRef
5.
go back to reference Augat P, Burger J, Schorlemmer S, Henke T, Peraus M, Claes L. Shear movement at the fracture site delays healing in a diaphyseal fracture model. J Orthop Res. 2003;21:1011–7.PubMedCrossRef Augat P, Burger J, Schorlemmer S, Henke T, Peraus M, Claes L. Shear movement at the fracture site delays healing in a diaphyseal fracture model. J Orthop Res. 2003;21:1011–7.PubMedCrossRef
6.
go back to reference Bhandari M, Guyatt GH, Swiontkowski MF, Schemitsch EH. Treatment of open fractures of the shaft of the tibia. J Bone Joint Surg Br. 2001;83:62–8.PubMedCrossRef Bhandari M, Guyatt GH, Swiontkowski MF, Schemitsch EH. Treatment of open fractures of the shaft of the tibia. J Bone Joint Surg Br. 2001;83:62–8.PubMedCrossRef
7.
go back to reference Kuner EH, Berwarth H, Lücke SV. Behandlungsprinzipien bei aseptischen Pseudarthrosen. Orthopäde. 1996;25:394–404.PubMedCrossRef Kuner EH, Berwarth H, Lücke SV. Behandlungsprinzipien bei aseptischen Pseudarthrosen. Orthopäde. 1996;25:394–404.PubMedCrossRef
8.
go back to reference Cui Y, Wang YJ, Hua QK, Cai SQ, Yan LM, Chen KJ. Biomechanical research in treating unstable Pilon fracture with anatomic plate of distal tibia. Zhongguo Gu Shang. 2009;22(7):519–21.PubMed Cui Y, Wang YJ, Hua QK, Cai SQ, Yan LM, Chen KJ. Biomechanical research in treating unstable Pilon fracture with anatomic plate of distal tibia. Zhongguo Gu Shang. 2009;22(7):519–21.PubMed
9.
go back to reference Lau TW, Leung F, Chan CF, Chow SP. Wound complication of minimally invasive plate osteosynthesis in distal tibia fractures. Int Orthop. 2008;32(5):697–703.PubMedCrossRef Lau TW, Leung F, Chan CF, Chow SP. Wound complication of minimally invasive plate osteosynthesis in distal tibia fractures. Int Orthop. 2008;32(5):697–703.PubMedCrossRef
11.
go back to reference Morrison JB. The mechanics of the knee joint in relation to normal walking. J Biomech. 1970;3:51–61.PubMedCrossRef Morrison JB. The mechanics of the knee joint in relation to normal walking. J Biomech. 1970;3:51–61.PubMedCrossRef
12.
go back to reference Bergmann G, Deuretzbacher G, Heller M, Graichen F, Rohlmann A, Strauss J, Duda GN. Hip contact forces and gait patterns from routine activities. J Biomech. 2001;34:859–71.PubMedCrossRef Bergmann G, Deuretzbacher G, Heller M, Graichen F, Rohlmann A, Strauss J, Duda GN. Hip contact forces and gait patterns from routine activities. J Biomech. 2001;34:859–71.PubMedCrossRef
13.
go back to reference Andriacchi TP, Alexander EJ, Toney MK, Dyrby C, Sum J. A point cluster method for in vivo motion analysis: applied to a study of knee kinematics. J Biomech Eng. 1998;120:743–9.PubMedCrossRef Andriacchi TP, Alexander EJ, Toney MK, Dyrby C, Sum J. A point cluster method for in vivo motion analysis: applied to a study of knee kinematics. J Biomech Eng. 1998;120:743–9.PubMedCrossRef
14.
go back to reference Mehler D, Hansen M, Rommens PM. Biomechanische Untersuchungen Verschiedener Osteosynthesen an der proximalen Tibia: Vorstellung einer neuartigen meßgeometrischen Anordnung. Biomedizinische Technik. 2003;48:319–24.PubMedCrossRef Mehler D, Hansen M, Rommens PM. Biomechanische Untersuchungen Verschiedener Osteosynthesen an der proximalen Tibia: Vorstellung einer neuartigen meßgeometrischen Anordnung. Biomedizinische Technik. 2003;48:319–24.PubMedCrossRef
15.
go back to reference Gaebler C, Stanzl-Tschegg S, Laube W, Vécsei V. The fatigue strength of small diameter tibial nails. Injury. 2000;32:401–5.CrossRef Gaebler C, Stanzl-Tschegg S, Laube W, Vécsei V. The fatigue strength of small diameter tibial nails. Injury. 2000;32:401–5.CrossRef
16.
go back to reference Hansen M, Mehler D, Hessmann MH, Blum J, Rommens PM. Intramedullary stabilization of extraarticular proximal tibial fractures: a biomechanical comparison of intramedullary and extramedullary implants including a new proximal tibia nail (PTN). J Orthop Trauma. 2007;21:701–9.PubMedCrossRef Hansen M, Mehler D, Hessmann MH, Blum J, Rommens PM. Intramedullary stabilization of extraarticular proximal tibial fractures: a biomechanical comparison of intramedullary and extramedullary implants including a new proximal tibia nail (PTN). J Orthop Trauma. 2007;21:701–9.PubMedCrossRef
17.
go back to reference Heller MO, Bergmann G, Deuretzbacher G, Dürselen L, Pohl M, Claes L, Haas NP, Duda GN. Musculo-skeletal loading conditions at the hip during walking and stair climbing. J Biomech. 2001;34:883–93.PubMedCrossRef Heller MO, Bergmann G, Deuretzbacher G, Dürselen L, Pohl M, Claes L, Haas NP, Duda GN. Musculo-skeletal loading conditions at the hip during walking and stair climbing. J Biomech. 2001;34:883–93.PubMedCrossRef
18.
go back to reference Jöllenbeck T, Schönle C. Die Teilbelastung nach Knie- oder Hüft-totalendoprothese: Unmöglichkeit der Einhaltung, ihre Ursachen und Abhilfen. Z Orthop Ihre Grenzgeb. 2005;143:124–8.CrossRef Jöllenbeck T, Schönle C. Die Teilbelastung nach Knie- oder Hüft-totalendoprothese: Unmöglichkeit der Einhaltung, ihre Ursachen und Abhilfen. Z Orthop Ihre Grenzgeb. 2005;143:124–8.CrossRef
19.
go back to reference Hoenig M, Gao F, Kinder J, Zhang LQ, Collinge C, Merk BR. Extra-articular distal tibia fractures: a mechanical evaluation of 4 different treatment methods. J Orthop Trauma. 2010;24(1):30–5.PubMedCrossRef Hoenig M, Gao F, Kinder J, Zhang LQ, Collinge C, Merk BR. Extra-articular distal tibia fractures: a mechanical evaluation of 4 different treatment methods. J Orthop Trauma. 2010;24(1):30–5.PubMedCrossRef
20.
go back to reference Augat P, Margevicius K, Simon J, Wolf S, Suger G, Claes L. Local tissue properties in bone healing: influence of size and stability of the osteotomy gap. J Orthop Res. 1998;16:475–81.PubMedCrossRef Augat P, Margevicius K, Simon J, Wolf S, Suger G, Claes L. Local tissue properties in bone healing: influence of size and stability of the osteotomy gap. J Orthop Res. 1998;16:475–81.PubMedCrossRef
21.
go back to reference Claes L, Augat P, Suger G, Wilke HJ. Influence of size and stability of the osteotomy gap on the success of fracture healing. J Orthop Res. 1997;15:577–84.PubMedCrossRef Claes L, Augat P, Suger G, Wilke HJ. Influence of size and stability of the osteotomy gap on the success of fracture healing. J Orthop Res. 1997;15:577–84.PubMedCrossRef
22.
go back to reference Claes LE, Heigele CA, Neidlinger-Wilke C, Kaspar D, Seidl W, Margevicius KJ, Augat P. Effects of mechanical factors on the fracture healing process. Clin Orthop Relat Res. 1998;355:S132–47.PubMedCrossRef Claes LE, Heigele CA, Neidlinger-Wilke C, Kaspar D, Seidl W, Margevicius KJ, Augat P. Effects of mechanical factors on the fracture healing process. Clin Orthop Relat Res. 1998;355:S132–47.PubMedCrossRef
23.
go back to reference Aro HT, Chao EY. Bone-healing patterns affected by loading, fracture fragment stability, fracture type, and fracture site compression. Clin Orthop Relat Res. 1993;293:8–17.PubMed Aro HT, Chao EY. Bone-healing patterns affected by loading, fracture fragment stability, fracture type, and fracture site compression. Clin Orthop Relat Res. 1993;293:8–17.PubMed
24.
go back to reference Goodship AE, Watkins PE, Rigby HS, Kenwright J. The role of fixator frame stiffness in the control of fracture healing. An experimental study. J Biomech. 1993;26:1027–35.PubMedCrossRef Goodship AE, Watkins PE, Rigby HS, Kenwright J. The role of fixator frame stiffness in the control of fracture healing. An experimental study. J Biomech. 1993;26:1027–35.PubMedCrossRef
25.
go back to reference Kenwright J, Goodship AE. Controlled mechanical stimulation in the treatment of tibial fractures. Clin Orthop Relat Res. 1989;241:36–47.PubMed Kenwright J, Goodship AE. Controlled mechanical stimulation in the treatment of tibial fractures. Clin Orthop Relat Res. 1989;241:36–47.PubMed
26.
go back to reference Schildhauer TA, Robie B, Muhr G, Köller M. Bacterial adherence to tantalum versus commonly used orthopedic metallic implant materials. J Orthop Trauma. 2006;20(7):476–84.PubMedCrossRef Schildhauer TA, Robie B, Muhr G, Köller M. Bacterial adherence to tantalum versus commonly used orthopedic metallic implant materials. J Orthop Trauma. 2006;20(7):476–84.PubMedCrossRef
27.
go back to reference Soong M, van Leerdam R, Guitton TG, Got C, Katarincic J, Ring D. Fracture of the distal radius: risk factors for complications after locked volar plate fixation. J Hand Surg Am. 2011;36(1):3–9.PubMedCrossRef Soong M, van Leerdam R, Guitton TG, Got C, Katarincic J, Ring D. Fracture of the distal radius: risk factors for complications after locked volar plate fixation. J Hand Surg Am. 2011;36(1):3–9.PubMedCrossRef
28.
go back to reference Rozental TD, Blazar PE. Functional outcome and complications after volar plating for dorsally displaced, unstable fractures of the distal radius. J Hand Surg Am. 2006;31(3):359–65.PubMedCrossRef Rozental TD, Blazar PE. Functional outcome and complications after volar plating for dorsally displaced, unstable fractures of the distal radius. J Hand Surg Am. 2006;31(3):359–65.PubMedCrossRef
Metadata
Title
Biomechanical comparison of two locking plate systems for the distal tibia
Authors
F. Högel
S. Hoffmann
P. Weninger
V. Bühren
P. Augat
Publication date
01-02-2012
Publisher
Springer-Verlag
Published in
European Journal of Trauma and Emergency Surgery / Issue 1/2012
Print ISSN: 1863-9933
Electronic ISSN: 1863-9941
DOI
https://doi.org/10.1007/s00068-011-0123-4

Other articles of this Issue 1/2012

European Journal of Trauma and Emergency Surgery 1/2012 Go to the issue