Skip to main content
Top
Published in: Journal of Orofacial Orthopedics / Fortschritte der Kieferorthopädie 3/2024

Open Access 11-11-2022 | Original article

Inadvertent side effects of fixed lingual retainers

An in vitro study

Authors: Marlen Seide, Teresa Kruse, Isabelle Graf, Christoph Bourauel, Bernd G. Lapatki, Rudolf Jäger, Bert Braumann

Published in: Journal of Orofacial Orthopedics / Fortschritte der Kieferorthopädie | Issue 3/2024

Login to get access

Abstract

Purpose

To better understand the side effects of fixed lingual retainers by means of an in vitro study in a two-tooth model determining the three-dimensional (3D) force–moment components acting at adjacent teeth combined with different composite–wire interfaces.

Methods

Triple-stranded round retainer wires were embedded in cured disks of flowable composite. At one side the composite–wire interface was untreated and checked to be absolutely fix. At the other side the composite–wire interface was configured as either an isolated compound with (1) petroleum jelly coating, or an adhered compound with (2) no manipulation, (3) ethanol degreasing or (4) ethanol degreasing and rectangular bending of the wire ends. The 3D force–moment components were registered, while the intertooth distance was increased in steps of 0.01 mm leading to increasing tension of the wire. Measurements were repeated after artificially aging the specimens.

Results

Retainer wire specimens with adhered compound (2, 3, 4) showed negative vestibulo-oral moments ranging maximally each between −0.3 and −0.9 Nmm in opposite direction to positive moments of 1.9 Nmm for specimens with isolated compound 1. Significant tipping moments occurred in the group with isolated compound at lower forces than in those groups with adhered compound. Similar effects were observed after artificial aging.

Conclusion

Side effects emerge under specific circumstances: an altered adhesive compound combined with the presence of oral forces. Compounds with lost adhesion at the composite–wire interface showed rotational moments in the direction of the wire windings even during low tensile forces similar to those that may occur in clinical settings. Opposite rotational moments leading to unwinding of the wire may occur in cases with adhered compounds at higher tensile forces. Utilization of round triple-stranded retainer wires without bent ends are of higher risk to induce inadvertent side effects.
Literature
5.
go back to reference Dahl EH, Zachrisson BU (1991) Long-term experience with direct-bonded lingual retainers. J Clin Orthod 25:619–630PubMed Dahl EH, Zachrisson BU (1991) Long-term experience with direct-bonded lingual retainers. J Clin Orthod 25:619–630PubMed
20.
go back to reference Proffit WR (1975) Muscle pressures and tooth position: North American whites and Australian aborigines. Angle Orthod 45:1–11. https://doi.org/10.1043/0003-3219(1975)045〈0001:MPATPN〉2.0.CO;2PubMed Proffit WR (1975) Muscle pressures and tooth position: North American whites and Australian aborigines. Angle Orthod 45:1–11. https://​doi.​org/​10.​1043/​0003-3219(1975)045〈0001:MPATPN〉2.0.CO;2PubMed
31.
go back to reference Zachrisson BJ (1995) Third-generation mandibular bonded lingual 3‑3 retainer. J Clin Orthod 29:39–48PubMed Zachrisson BJ (1995) Third-generation mandibular bonded lingual 3‑3 retainer. J Clin Orthod 29:39–48PubMed
Metadata
Title
Inadvertent side effects of fixed lingual retainers
An in vitro study
Authors
Marlen Seide
Teresa Kruse
Isabelle Graf
Christoph Bourauel
Bernd G. Lapatki
Rudolf Jäger
Bert Braumann
Publication date
11-11-2022
Publisher
Springer Medizin
Published in
Journal of Orofacial Orthopedics / Fortschritte der Kieferorthopädie / Issue 3/2024
Print ISSN: 1434-5293
Electronic ISSN: 1615-6714
DOI
https://doi.org/10.1007/s00056-022-00432-4

Other articles of this Issue 3/2024

Journal of Orofacial Orthopedics / Fortschritte der Kieferorthopädie 3/2024 Go to the issue

Mitteilungen der DGKFO

Mitteilungen der DGKFO