Influence of attachment bonding protocol on precision of the attachment in aligner treatments

Authors: Julia Weckmann, Dr. Sven Scharf, Isabelle Graf, Jörg Schwarze, Ludger Keilig, Christoph Bourauel, Bert Braumann

Published in: Journal of Orofacial Orthopedics / Fortschritte der Kieferorthopädie | Issue 1/2020

Login to get access

Abstract

Aim

Precise bonding of attachments in aligner treatment is crucial to achieve the intended tooth movement. Thus, we evaluated five different bonding protocols for attachments used in aligner treatments with the goal of identifying the most precise protocol.

Methods

One ellipsoid and one rectangular attachment were exemplarily chosen and examined. All attachments were bonded using the same template aligner, which was produced by thermoforming. The bonding process was repeated 30 times with each protocol for statistical analysis. The protocols differed in the type of composite used (high viscous, low viscous), the additional application of a perforation in the attachment reservoir, and the use of a two-phase procedure with high viscous composite. All bonded attachments were laser scanned and compared to the attachments of a master model using a surface/surface matching algorithm to determine the precision, i.e., highest aberrations (maximum vertical distance) between the attachment of the master and results obtained from the various bonding protocols. Furthermore, the excessive amounts of composite bonded around the attachments were measured and compared.

Results

The two-phase procedure had a median aberration of 0.13 mm and a median amount of excessive composite of 7.40 mm2 (ellipsoid attachment). With the low viscous composite without a perforation in the template reservoir, similar results were achieved (median 0.13 mm) regarding the maximum vertical distance, but had an excess area of 33.50 mm2.

Conclusion

In this in vitro study, the bonding protocol influenced the precision of bonded attachments. The bonding protocol with high viscous composite without a perforation in the attachment reservoir was the most inaccurate. The use of a low viscous composite or attachments made by a two-phase procedure with high viscous composite revealed more precise results.
Literature
2.
go back to reference Barreda GJ, Dzierewianko EA, Muñoz KA, Piccoli GI (2017) Surface wear of resin composites used for Invisalign® attachments. Acta Odontol Latinoam 30:90–95PubMed Barreda GJ, Dzierewianko EA, Muñoz KA, Piccoli GI (2017) Surface wear of resin composites used for Invisalign® attachments. Acta Odontol Latinoam 30:90–95PubMed
4.
go back to reference Böhme A, Jost-Brinkmann P‑G, Miethke R‑R (2003) Möglichkeiten der adhäsiven Befestigung von Invisalign®-Attachments. Kieferorthopädie 17:1001–1006 Böhme A, Jost-Brinkmann P‑G, Miethke R‑R (2003) Möglichkeiten der adhäsiven Befestigung von Invisalign®-Attachments. Kieferorthopädie 17:1001–1006
6.
go back to reference Garino F, Castroflorio T, Daher S et al (2016) Effectiveness of composite attachments in controlling upper-molar movement with aligners. J Clin Orthod 50:341–347PubMed Garino F, Castroflorio T, Daher S et al (2016) Effectiveness of composite attachments in controlling upper-molar movement with aligners. J Clin Orthod 50:341–347PubMed
13.
go back to reference Kuncio D (2014) Invisalign: current guidelines for effective treatment. N Y State Dent J 80:11–14PubMed Kuncio D (2014) Invisalign: current guidelines for effective treatment. N Y State Dent J 80:11–14PubMed
17.
go back to reference McNamara JA, Kramer KL, Juenker JP (1985) Invisible retainers. J Clin Orthod 19:570–578PubMed McNamara JA, Kramer KL, Juenker JP (1985) Invisible retainers. J Clin Orthod 19:570–578PubMed
18.
go back to reference Ralph WJ, Jefferies JR (1984) The minimal width of the periodontal space. J Oral Rehabil 11:415–418CrossRef Ralph WJ, Jefferies JR (1984) The minimal width of the periodontal space. J Oral Rehabil 11:415–418CrossRef
20.
go back to reference Schwarz AM (1932) Tissue changes incidental to orthodontic tooth movement. Int J Orthod 18:331–352 Schwarz AM (1932) Tissue changes incidental to orthodontic tooth movement. Int J Orthod 18:331–352
25.
go back to reference Weir T (2016) Invisalign treatment of lower incisor extraction cases. Aust Orthod J 32:82–87PubMed Weir T (2016) Invisalign treatment of lower incisor extraction cases. Aust Orthod J 32:82–87PubMed
Metadata
Title
Influence of attachment bonding protocol on precision of the attachment in aligner treatments
Authors
Julia Weckmann
Dr. Sven Scharf
Isabelle Graf
Jörg Schwarze
Ludger Keilig
Christoph Bourauel
Bert Braumann
Publication date
01-01-2020
Publisher
Springer Medizin
Keyword
Aligner
Published in
Journal of Orofacial Orthopedics / Fortschritte der Kieferorthopädie / Issue 1/2020
Print ISSN: 1434-5293
Electronic ISSN: 1615-6714
DOI
https://doi.org/10.1007/s00056-019-00204-7

Other articles of this Issue 1/2020

Journal of Orofacial Orthopedics / Fortschritte der Kieferorthopädie 1/2020 Go to the issue

Mitteilungen der DGKFO

Mitteilungen der DGKFO

Arnold-Biber Research Award

Artificial intelligence in orthodontics