Skip to main content
Top
Published in: Nuclear Medicine and Molecular Imaging 6/2021

01-12-2021 | Computed Tomography | Review

A Brief History of Nuclear Medicine Physics, Instrumentation, and Data Sciences in Korea

Authors: Jae Sung Lee, Kyeong Min Kim, Yong Choi, Hee-Joung Kim

Published in: Nuclear Medicine and Molecular Imaging | Issue 6/2021

Login to get access

Abstract

We review the history of nuclear medicine physics, instrumentation, and data sciences in Korea to commemorate the 60th anniversary of the Korean Society of Nuclear Medicine. In the 1970s and 1980s, the development of SPECT, nuclear stethoscope, and bone densitometry systems, as well as kidney and cardiac image analysis technology, marked the beginning of nuclear medicine physics and engineering in Korea. With the introduction of PET and cyclotron in Korea in 1994, nuclear medicine imaging research was further activated. With the support of large-scale government projects, the development of gamma camera, SPECT, and PET systems was carried out. Exploiting the use of PET scanners in conjunction with cyclotrons, extensive studies on myocardial blood flow quantification and brain image analysis were also actively pursued. In 2005, Korea’s first domestic cyclotron succeeded in producing radioactive isotopes, and the cyclotron was provided to six universities and university hospitals, thereby facilitating the nationwide supply of PET radiopharmaceuticals. Since the late 2000s, research on PET/MRI has been actively conducted, and the advanced research results of Korean scientists in the fields of silicon photomultiplier PET and simultaneous PET/MRI have attracted significant attention from the academic community. Currently, Korean researchers are actively involved in endeavors to solve a variety of complex problems in nuclear medicine using artificial intelligence and deep learning technologies.
Literature
1.
2.
go back to reference Lee MH, Hahn SS, Lee SH, Lee JK, Kang SS, Koh CS, et al. Investigation and treatment of disease of the thyroid gland with radioactive iodine: the first report. Korean J Med. 1961;4:29–49. Lee MH, Hahn SS, Lee SH, Lee JK, Kang SS, Koh CS, et al. Investigation and treatment of disease of the thyroid gland with radioactive iodine: the first report. Korean J Med. 1961;4:29–49.
3.
go back to reference Toh SH. Thyroid and radioactive I-131. J Korean Med Assoc. 1961;4:72–83. Toh SH. Thyroid and radioactive I-131. J Korean Med Assoc. 1961;4:72–83.
4.
go back to reference Lee M-H. The present status of nuclear medicine in Korea. Korean J Nucl Med. 1968;2:9–14. Lee M-H. The present status of nuclear medicine in Korea. Korean J Nucl Med. 1968;2:9–14.
5.
go back to reference Cho ZH, Chan JK, Eriksson L. Circular ring transverse axial positron camera for 3-dimensional reconstruction of radionuclides distribution. IEEE Trans Nucl Sci. 1976;23:613–22.CrossRef Cho ZH, Chan JK, Eriksson L. Circular ring transverse axial positron camera for 3-dimensional reconstruction of radionuclides distribution. IEEE Trans Nucl Sci. 1976;23:613–22.CrossRef
6.
go back to reference Cho Z, Farukhi M. Bismuth germanate as a potential scintillation detector in positron cameras. J Nucl Med. 1977;18:840–4.PubMed Cho Z, Farukhi M. Bismuth germanate as a potential scintillation detector in positron cameras. J Nucl Med. 1977;18:840–4.PubMed
7.
go back to reference Cho Z, Hong K, Hilal S. Spherical positron emission tomograph (S-PET) I-performance analysis. Nucl Instrum Methods Phys Res. 1984;225:422–38.CrossRef Cho Z, Hong K, Hilal S. Spherical positron emission tomograph (S-PET) I-performance analysis. Nucl Instrum Methods Phys Res. 1984;225:422–38.CrossRef
8.
go back to reference Cho Z, Hong K, Ra JB, Lee S, Hilal S, Correll J. A new sampling scheme for the ring positron camera: Dichotomic ring sampling. IEEE Trans Nucl Sci. 1981;28:94–8.CrossRef Cho Z, Hong K, Ra JB, Lee S, Hilal S, Correll J. A new sampling scheme for the ring positron camera: Dichotomic ring sampling. IEEE Trans Nucl Sci. 1981;28:94–8.CrossRef
9.
go back to reference Cho ZH, Yi W, Jung KJ, Lee BU, Min HB, Song HB. Performance of single photon tomographic system - GAMMATOM-1. IEEE Trans Nucl Sci. 1982;29:484–7.CrossRef Cho ZH, Yi W, Jung KJ, Lee BU, Min HB, Song HB. Performance of single photon tomographic system - GAMMATOM-1. IEEE Trans Nucl Sci. 1982;29:484–7.CrossRef
10.
go back to reference Ra JB, Lim C, Cho Z, Hilal S, Correll J. A true three-dimensional reconstruction algorithm for the spherical positron emission tomograph. Phys Med Biol. 1982;27:37–50.CrossRef Ra JB, Lim C, Cho Z, Hilal S, Correll J. A true three-dimensional reconstruction algorithm for the spherical positron emission tomograph. Phys Med Biol. 1982;27:37–50.CrossRef
11.
go back to reference Cho ZH, Son YD, Kim HK, Kim KN, Oh SH, Han JY, et al. A fusion PET–MRI system with a high-resolution research tomograph-PET and ultra-high field 7.0 T-MRI for the molecular-genetic imaging of the brain. Proteomics. 2008;8:1302–23.PubMedCrossRef Cho ZH, Son YD, Kim HK, Kim KN, Oh SH, Han JY, et al. A fusion PET–MRI system with a high-resolution research tomograph-PET and ultra-high field 7.0 T-MRI for the molecular-genetic imaging of the brain. Proteomics. 2008;8:1302–23.PubMedCrossRef
12.
go back to reference Cho ZH, Son YD, Kim HK, Kim NB, Choi EJ, Lee SY, et al. Observation of glucose metabolism in the thalamic nuclei by fusion PET/MRI. J Nucl Med. 2011;52:401–4.PubMedCrossRef Cho ZH, Son YD, Kim HK, Kim NB, Choi EJ, Lee SY, et al. Observation of glucose metabolism in the thalamic nuclei by fusion PET/MRI. J Nucl Med. 2011;52:401–4.PubMedCrossRef
13.
go back to reference Hong IK, Chung ST, Kim HK, Kim YB, Son YD, Cho ZH. Ultra fast symmetry and SIMD-based projection-backprojection (SSP) algorithm for 3-D PET image reconstruction. IEEE Trans Med Imaging. 2007;26:789–803.PubMedCrossRef Hong IK, Chung ST, Kim HK, Kim YB, Son YD, Cho ZH. Ultra fast symmetry and SIMD-based projection-backprojection (SSP) algorithm for 3-D PET image reconstruction. IEEE Trans Med Imaging. 2007;26:789–803.PubMedCrossRef
14.
go back to reference Lim C, Gottschalk S, Walker R, Schreiner R, Valentino F, Pinkstaff C, et al. Triangular SPECT system for 3-D total organ volume imaging: design concept and preliminary imaging results. IEEE Trans Nucl Sci. 1985;32:741–7.CrossRef Lim C, Gottschalk S, Walker R, Schreiner R, Valentino F, Pinkstaff C, et al. Triangular SPECT system for 3-D total organ volume imaging: design concept and preliminary imaging results. IEEE Trans Nucl Sci. 1985;32:741–7.CrossRef
15.
go back to reference Lim C, Walker R, Pinkstaff C, Kim K, Anderson J, King S, et al. Triangular SPECT system for 3-D total organ volume imaging: performance results and dynamic imaging capability. IEEE Trans Nucl Sci. 1986;33:501–4.CrossRef Lim C, Walker R, Pinkstaff C, Kim K, Anderson J, King S, et al. Triangular SPECT system for 3-D total organ volume imaging: performance results and dynamic imaging capability. IEEE Trans Nucl Sci. 1986;33:501–4.CrossRef
16.
go back to reference Yoo H, Min BG, Lee MC, Kim SK, Lee JS, Koh C-S. A study on the quantitative evaluation of renal function using compartment model. Seoul J Med. 1983;24:437–41. Yoo H, Min BG, Lee MC, Kim SK, Lee JS, Koh C-S. A study on the quantitative evaluation of renal function using compartment model. Seoul J Med. 1983;24:437–41.
17.
go back to reference Min B-G, Kim Y-H, Koh C-S. A study on left ventricular volume change measurement using nuclear stethoscope. J Biomed Eng Res. 1984;5:167–72. Min B-G, Kim Y-H, Koh C-S. A study on left ventricular volume change measurement using nuclear stethoscope. J Biomed Eng Res. 1984;5:167–72.
18.
go back to reference Bong JG, Kim HJ, So SG, Kim HM, Lee JD, Gwon SI. Development of imaging gamma probe using the position sensitive PMTube. J Biomed Eng Res. 1999;20:107–13. Bong JG, Kim HJ, So SG, Kim HM, Lee JD, Gwon SI. Development of imaging gamma probe using the position sensitive PMTube. J Biomed Eng Res. 1999;20:107–13.
19.
go back to reference Yang MG, Kwark C, Shim YG, Kim H-J, Choi Y, Chung J-K, et al. Design and performance evaluation of small size counting and imaging gamma probe system. J Biomed Eng Res. 1997;18:291–9. Yang MG, Kwark C, Shim YG, Kim H-J, Choi Y, Chung J-K, et al. Design and performance evaluation of small size counting and imaging gamma probe system. J Biomed Eng Res. 1997;18:291–9.
20.
go back to reference Kim J-H, Choi Y, Kim J-Y, Im K-C, Kim S-E, Choi Y-S, et al. Monte Carlo simulations of detection efficiency and position resolution of NaI(TI)-PMT detector used in small gamma camera. Prog Med Phys. 1997;8:67–76. Kim J-H, Choi Y, Kim J-Y, Im K-C, Kim S-E, Choi Y-S, et al. Monte Carlo simulations of detection efficiency and position resolution of NaI(TI)-PMT detector used in small gamma camera. Prog Med Phys. 1997;8:67–76.
21.
go back to reference Kim JH, Choi Y, Joo KS, Sihn BS, Chong JW, Kim SE, et al. Development of a miniature scintillation camera using an NaI(Tl) scintillator and PSPMT for scintimammography. Phys Med Biol. 2000;45:3481–8.PubMedCrossRef Kim JH, Choi Y, Joo KS, Sihn BS, Chong JW, Kim SE, et al. Development of a miniature scintillation camera using an NaI(Tl) scintillator and PSPMT for scintimammography. Phys Med Biol. 2000;45:3481–8.PubMedCrossRef
22.
go back to reference Choi Y, Kim J-H, Kim J-Y, Im K-C, Kim S-E, Choe Y-S, et al. Investigation of the signal characteristics of a small gamma camera system using NaI(Tl)-position sensitive photomultiplier tube. Korean J Nucl Med. 2000;34:82–93.CrossRef Choi Y, Kim J-H, Kim J-Y, Im K-C, Kim S-E, Choe Y-S, et al. Investigation of the signal characteristics of a small gamma camera system using NaI(Tl)-position sensitive photomultiplier tube. Korean J Nucl Med. 2000;34:82–93.CrossRef
23.
go back to reference Kim H-J, So S-G, Bong J-G, Kim H-M, Kim J-H, Ju G-S, et al. A study of digitalizing analog gamma camera using Gamma-PF board. J Biomed Eng Res. 1998;19:351–60. Kim H-J, So S-G, Bong J-G, Kim H-M, Kim J-H, Ju G-S, et al. A study of digitalizing analog gamma camera using Gamma-PF board. J Biomed Eng Res. 1998;19:351–60.
24.
go back to reference Bong J-K, Kim H-J, Im J-H, Yang S-O, Moon D-H, Ryu J-S, et al. A study of dopamine transporter imaging and comparison of noninvasive simplified quantitative methods in normal controls and Parkinson’s patients. Korean J Nucl Med. 1996;30:315–24. Bong J-K, Kim H-J, Im J-H, Yang S-O, Moon D-H, Ryu J-S, et al. A study of dopamine transporter imaging and comparison of noninvasive simplified quantitative methods in normal controls and Parkinson’s patients. Korean J Nucl Med. 1996;30:315–24.
25.
go back to reference Kim H-J, Son H-K, Bong J-K, Nam K-P, Lee H-K. Collimator selection in nuclear medicine imaging using I-123 generated by Te-124 reaction. Korean J Nucl Med. 1996;30:372–8. Kim H-J, Son H-K, Bong J-K, Nam K-P, Lee H-K. Collimator selection in nuclear medicine imaging using I-123 generated by Te-124 reaction. Korean J Nucl Med. 1996;30:372–8.
26.
go back to reference Son H-K, Nha S-K, Lee H-K, Kim H-J. The measurement of sensitivity and comparative analysis of simplified quantitation methods to measure dopamine transporters using [I-123] IPT pharmacokinetic computer simulations. Korean J Nucl Med. 1997;31:19–29. Son H-K, Nha S-K, Lee H-K, Kim H-J. The measurement of sensitivity and comparative analysis of simplified quantitation methods to measure dopamine transporters using [I-123] IPT pharmacokinetic computer simulations. Korean J Nucl Med. 1997;31:19–29.
27.
go back to reference Kim HJ, Im JH, Yang SO, Moon DH, Ryu JS, Bong JK, et al. Imaging and quantitation of dopamine transporters with iodine-123-IPT in normal and Parkinson’s disease subjects. J Nucl Med. 1997;38:1703–11.PubMed Kim HJ, Im JH, Yang SO, Moon DH, Ryu JS, Bong JK, et al. Imaging and quantitation of dopamine transporters with iodine-123-IPT in normal and Parkinson’s disease subjects. J Nucl Med. 1997;38:1703–11.PubMed
28.
go back to reference Wagner HN Jr. SNM annual meeting: medical problem solving. J Nucl Med. 1996;37:11N-4N, 7N, 26N Wagner HN Jr. SNM annual meeting: medical problem solving. J Nucl Med. 1996;37:11N-4N, 7N, 26N
29.
go back to reference Lee D-S, Lee T-H, Kim K-M, Chung J-K, Lee M-C, Koh C-S. Optimization of subtraction brain perfusion SPECT with basal/acetazolamide consecutive acquisition. Korean J Nucl Med. 1997;31:330–8. Lee D-S, Lee T-H, Kim K-M, Chung J-K, Lee M-C, Koh C-S. Optimization of subtraction brain perfusion SPECT with basal/acetazolamide consecutive acquisition. Korean J Nucl Med. 1997;31:330–8.
30.
go back to reference Kim K-M, Lee D-S, Kim S-K, Lee J-S, Kang K-W, Yeo J-S, et al. Quantification of cerebrovascular reserve using Tc-99m HMPAO brain SPECT and lassen’s algorithm. Korean J Nucl Med. 2000;34:322–35.CrossRef Kim K-M, Lee D-S, Kim S-K, Lee J-S, Kang K-W, Yeo J-S, et al. Quantification of cerebrovascular reserve using Tc-99m HMPAO brain SPECT and lassen’s algorithm. Korean J Nucl Med. 2000;34:322–35.CrossRef
31.
go back to reference Lee DS, Kim KM, Kim SK, Cheon GJ, Kim YK, Chung JK, et al. Development of a method for measuring myocardial contractility with gated myocardial SPECT and arterial tonometry. J Nucl Cardiol. 1999;6:657–63.PubMedCrossRef Lee DS, Kim KM, Kim SK, Cheon GJ, Kim YK, Chung JK, et al. Development of a method for measuring myocardial contractility with gated myocardial SPECT and arterial tonometry. J Nucl Cardiol. 1999;6:657–63.PubMedCrossRef
32.
go back to reference Ahn JY, Lee DS, Lee JS, Kim SK, Cheon GJ, Yeo JS, et al. Quantification of regional myocardial blood flow using dynamic H2(15)O PET and factor analysis. J Nucl Med. 2001;42:782–7.PubMed Ahn JY, Lee DS, Lee JS, Kim SK, Cheon GJ, Yeo JS, et al. Quantification of regional myocardial blood flow using dynamic H2(15)O PET and factor analysis. J Nucl Med. 2001;42:782–7.PubMed
33.
go back to reference Lee BI, Lee JS, Lee DS, Choi S. Myocardial blood flow quantification in dynamic PET: An ensemble ICA approach. Lect Notes Comput Sci. 2005;3697:709–14.CrossRef Lee BI, Lee JS, Lee DS, Choi S. Myocardial blood flow quantification in dynamic PET: An ensemble ICA approach. Lect Notes Comput Sci. 2005;3697:709–14.CrossRef
34.
go back to reference Lee JS, Lee DD, Choi S, Park KS, Lee DS. Non-negative matrix factorization of dynamic images in nuclear medicine. IEEE Nucl Sci Symp Conf Rec. 2001;4:2027–30. Lee JS, Lee DD, Choi S, Park KS, Lee DS. Non-negative matrix factorization of dynamic images in nuclear medicine. IEEE Nucl Sci Symp Conf Rec. 2001;4:2027–30.
35.
go back to reference Lee JS, Lee DS, Ahn JY, Cheon GJ, Kim SK, Yeo JS, et al. Parametric image of myocardial blood flow generated from dynamic H2(15)O PET using factor analysis and cluster analysis. Med Biol Eng Comput. 2005;43:678–85.PubMedCrossRef Lee JS, Lee DS, Ahn JY, Cheon GJ, Kim SK, Yeo JS, et al. Parametric image of myocardial blood flow generated from dynamic H2(15)O PET using factor analysis and cluster analysis. Med Biol Eng Comput. 2005;43:678–85.PubMedCrossRef
36.
go back to reference Lee JS, Lee DS, Ahn JY, Cheon GJ, Kim SK, Yeo JS, et al. Blind separation of cardiac components and extraction of input function from H(2)(15)O dynamic myocardial PET using independent component analysis. J Nucl Med. 2001;42:938–43.PubMed Lee JS, Lee DS, Ahn JY, Cheon GJ, Kim SK, Yeo JS, et al. Blind separation of cardiac components and extraction of input function from H(2)(15)O dynamic myocardial PET using independent component analysis. J Nucl Med. 2001;42:938–43.PubMed
37.
go back to reference Lee JS, Lee DS, Ahn JY, Yeo JS, Cheon GJ, Kim SK, et al. Generation of parametric image of regional myocardial blood flow using H(2)(15)O dynamic PET and a linear least-squares method. J Nucl Med. 2005;46:1687–95.PubMed Lee JS, Lee DS, Ahn JY, Yeo JS, Cheon GJ, Kim SK, et al. Generation of parametric image of regional myocardial blood flow using H(2)(15)O dynamic PET and a linear least-squares method. J Nucl Med. 2005;46:1687–95.PubMed
38.
go back to reference Choi Y, Huang S-C, Hawkins RA, Kim JY, Kim B-T, Hoh CK, et al. Quantification of myocardial blood flow using 13N-ammonia and PET: comparison of tracer models. J Nucl Med. 1999;40:1045–55.PubMed Choi Y, Huang S-C, Hawkins RA, Kim JY, Kim B-T, Hoh CK, et al. Quantification of myocardial blood flow using 13N-ammonia and PET: comparison of tracer models. J Nucl Med. 1999;40:1045–55.PubMed
39.
go back to reference Choi Y, Kim J-Y, Im K-C, Kim J-H, Woo S-K, Lee K-H, et al. Quantification of myocardial blood flow using dynamic N-13 ammonia PET and factor analysis. Korean J Nucl Med. 1999;33:316–26. Choi Y, Kim J-Y, Im K-C, Kim J-H, Woo S-K, Lee K-H, et al. Quantification of myocardial blood flow using dynamic N-13 ammonia PET and factor analysis. Korean J Nucl Med. 1999;33:316–26.
40.
go back to reference Kim J-Y, Lee K-H, Kim S-E, Choe Y-S, Ju H-K, Kim Y-J, et al. A refined method for quantification of myocardial blood flow using N-13 ammonia and dynamic PET. Korean J Nucl Med. 1997;31:73–82. Kim J-Y, Lee K-H, Kim S-E, Choe Y-S, Ju H-K, Kim Y-J, et al. A refined method for quantification of myocardial blood flow using N-13 ammonia and dynamic PET. Korean J Nucl Med. 1997;31:73–82.
41.
go back to reference Kim SJ, Lee JS, Kim YK, Frost J, Wand G, McCaul ME, et al. Multiple linear analysis methods for the quantification of irreversibly binding radiotracers. J Cereb Blood Flow Metab. 2008;28:1965–77.PubMedCrossRef Kim SJ, Lee JS, Kim YK, Frost J, Wand G, McCaul ME, et al. Multiple linear analysis methods for the quantification of irreversibly binding radiotracers. J Cereb Blood Flow Metab. 2008;28:1965–77.PubMedCrossRef
42.
go back to reference Seo S, Kim SJ, Yoo HB, Lee JY, Kim YK, Lee DS, et al. Noninvasive bi-graphical analysis for the quantification of slowly reversible radioligand binding. Phys Med Biol. 2016;61:6770–90.PubMedCrossRef Seo S, Kim SJ, Yoo HB, Lee JY, Kim YK, Lee DS, et al. Noninvasive bi-graphical analysis for the quantification of slowly reversible radioligand binding. Phys Med Biol. 2016;61:6770–90.PubMedCrossRef
43.
go back to reference Kim JW, Lee JS, Kim SJ, Hoigebazar L, Shin K-H, Yu K-S, et al. Compartmental modeling and simplified quantification of [11C] sertraline distribution in human brain. Arch Pharmacal Res. 2012;35:1591–7.CrossRef Kim JW, Lee JS, Kim SJ, Hoigebazar L, Shin K-H, Yu K-S, et al. Compartmental modeling and simplified quantification of [11C] sertraline distribution in human brain. Arch Pharmacal Res. 2012;35:1591–7.CrossRef
44.
go back to reference Kim JH, Kim Y-H, Kim YJ, Yang BY, Jeong JM, Youn H, et al. Quantitative positron emission tomography imaging of angiogenesis in rats with forelimb ischemia using 68 Ga-NOTA-c(RGDyK). Angiogenesis. 2013;16:837–46.PubMedCrossRef Kim JH, Kim Y-H, Kim YJ, Yang BY, Jeong JM, Youn H, et al. Quantitative positron emission tomography imaging of angiogenesis in rats with forelimb ischemia using 68 Ga-NOTA-c(RGDyK). Angiogenesis. 2013;16:837–46.PubMedCrossRef
45.
go back to reference Seo S, Kim SJ, Kim YK, Lee J-Y, Jeong JM, Lee DS, et al. Comparative assessment of parametric neuroreceptor mapping approaches based on the simplified reference tissue model using [11C] ABP688 PET. J Cereb Blood Flow Metab. 2015;35:2098–108.PubMedPubMedCentralCrossRef Seo S, Kim SJ, Kim YK, Lee J-Y, Jeong JM, Lee DS, et al. Comparative assessment of parametric neuroreceptor mapping approaches based on the simplified reference tissue model using [11C] ABP688 PET. J Cereb Blood Flow Metab. 2015;35:2098–108.PubMedPubMedCentralCrossRef
46.
go back to reference Seo S, Kim SJ, Lee DS, Lee JS. Recent advances in parametric neuroreceptor mapping with dynamic PET: basic concepts and graphical analyses. Neurosci Bull. 2014;30:733–54.PubMedPubMedCentralCrossRef Seo S, Kim SJ, Lee DS, Lee JS. Recent advances in parametric neuroreceptor mapping with dynamic PET: basic concepts and graphical analyses. Neurosci Bull. 2014;30:733–54.PubMedPubMedCentralCrossRef
47.
go back to reference Kim SJ, Lee JS, Im KC, Kim S-Y, Park S-A, Lee SJ, et al. Kinetic modeling of 3′-deoxy-3′-18F-fluorothymidine for quantitative cell proliferation imaging in subcutaneous tumor models in mice. J Nucl Med. 2008;49:2057–66.PubMedCrossRef Kim SJ, Lee JS, Im KC, Kim S-Y, Park S-A, Lee SJ, et al. Kinetic modeling of 3′-deoxy-3′-18F-fluorothymidine for quantitative cell proliferation imaging in subcutaneous tumor models in mice. J Nucl Med. 2008;49:2057–66.PubMedCrossRef
48.
go back to reference Lim KS, Kwon JS, Jang IJ, Jeong JM, Lee JS, Kim HW, et al. Modeling of brain D2 receptor occupancy-plasma concentration relationships with a novel antipsychotic, YKP1358, using serial PET scans in healthy volunteers. Clin Pharmacol Ther. 2007;81:252–8.PubMedCrossRef Lim KS, Kwon JS, Jang IJ, Jeong JM, Lee JS, Kim HW, et al. Modeling of brain D2 receptor occupancy-plasma concentration relationships with a novel antipsychotic, YKP1358, using serial PET scans in healthy volunteers. Clin Pharmacol Ther. 2007;81:252–8.PubMedCrossRef
49.
go back to reference Lee DS, Lee JS, Kim KM, Chung J-K, Lee MC. Functional brain mapping using H2(15)O positron emission tomography (I): Statistical parametric mapping method. Korean J Nucl Med. 1998;32:225–37. Lee DS, Lee JS, Kim KM, Chung J-K, Lee MC. Functional brain mapping using H2(15)O positron emission tomography (I): Statistical parametric mapping method. Korean J Nucl Med. 1998;32:225–37.
50.
go back to reference Lee JS, Lee DS, Lee SK, Nam HW, Kim S-K, Park KS, et al. Functional brain mapping using H2(15)O positron emission tomography (II): Mapping of human working memory. Korean J Nucl Med. 1998;32:238–49. Lee JS, Lee DS, Lee SK, Nam HW, Kim S-K, Park KS, et al. Functional brain mapping using H2(15)O positron emission tomography (II): Mapping of human working memory. Korean J Nucl Med. 1998;32:238–49.
51.
go back to reference Kwon JS, Kim JJ, Lee DW, Lee JS, Lee DS, Kim MS, et al. Neural correlates of clinical symptoms and cognitive dysfunctions in obsessive-compulsive disorder. Psychiatry Res. 2003;122:37–47.PubMedCrossRef Kwon JS, Kim JJ, Lee DW, Lee JS, Lee DS, Kim MS, et al. Neural correlates of clinical symptoms and cognitive dysfunctions in obsessive-compulsive disorder. Psychiatry Res. 2003;122:37–47.PubMedCrossRef
52.
go back to reference Lee DS, Lee JS, Oh SH, Kim SK, Kim JW, Chung JK, et al. Cross-modal plasticity and cochlear implants. Nature. 2001;409:149–50.PubMedCrossRef Lee DS, Lee JS, Oh SH, Kim SK, Kim JW, Chung JK, et al. Cross-modal plasticity and cochlear implants. Nature. 2001;409:149–50.PubMedCrossRef
53.
go back to reference Lee JS, Kim BN, Kang E, Lee DS, Kim YK, Chung JK, et al. Regional cerebral blood flow in children with attention deficit hyperactivity disorder: comparison before and after methylphenidate treatment. Hum Brain Mapp. 2005;24:157–64.PubMedCrossRef Lee JS, Kim BN, Kang E, Lee DS, Kim YK, Chung JK, et al. Regional cerebral blood flow in children with attention deficit hyperactivity disorder: comparison before and after methylphenidate treatment. Hum Brain Mapp. 2005;24:157–64.PubMedCrossRef
54.
go back to reference Lee JS, Lee DS, Oh SH, Kim CS, Kim JW, Hwang CH, et al. PET evidence of neuroplasticity in adult auditory cortex of postlingual deafness. J Nucl Med. 2003;44:1435–9.PubMed Lee JS, Lee DS, Oh SH, Kim CS, Kim JW, Hwang CH, et al. PET evidence of neuroplasticity in adult auditory cortex of postlingual deafness. J Nucl Med. 2003;44:1435–9.PubMed
56.
go back to reference Lee JS, Lee DS, Kim YK, Kim J, Lee HY, Lee SK, et al. Probabilistic map of blood flow distribution in the brain from the internal carotid artery. Neuroimage. 2004;23:1422–31.PubMedCrossRef Lee JS, Lee DS, Kim YK, Kim J, Lee HY, Lee SK, et al. Probabilistic map of blood flow distribution in the brain from the internal carotid artery. Neuroimage. 2004;23:1422–31.PubMedCrossRef
57.
go back to reference Kim SJ, Kim IJ, Kim YK, Lee TH, Lee JS, Jun S, et al. Probabilistic anatomic mapping of cerebral blood flow distribution of the middle cerebral artery. J Nucl Med. 2008;49:39–43.PubMedCrossRef Kim SJ, Kim IJ, Kim YK, Lee TH, Lee JS, Jun S, et al. Probabilistic anatomic mapping of cerebral blood flow distribution of the middle cerebral artery. J Nucl Med. 2008;49:39–43.PubMedCrossRef
58.
go back to reference Lee JS, Lee DS. Analysis of functional brain images using population-based probabilistic atlas. Curr Med Imaging Rev. 2005;1:81–7.CrossRef Lee JS, Lee DS. Analysis of functional brain images using population-based probabilistic atlas. Curr Med Imaging Rev. 2005;1:81–7.CrossRef
59.
go back to reference Koo B, Lee J, Kim J, Lee J, Kim I, Kim J, et al. Developing a Korean standard brain atlas on the basis of statistical and probabilistic approach and visualization tool for functional image analysis. Korean J Nucl Med. 2003;37:162–70. Koo B, Lee J, Kim J, Lee J, Kim I, Kim J, et al. Developing a Korean standard brain atlas on the basis of statistical and probabilistic approach and visualization tool for functional image analysis. Korean J Nucl Med. 2003;37:162–70.
60.
go back to reference Lee J-S, Lee D-S, Kim Y-K, Kim J-S, Lee J-M, Koo B-B, et al. Quantification of brain images using Korean standard templates and structural and cytoarchitectonic probabilistic maps. Korean J Nucl Med. 2004;38:241–52. Lee J-S, Lee D-S, Kim Y-K, Kim J-S, Lee J-M, Koo B-B, et al. Quantification of brain images using Korean standard templates and structural and cytoarchitectonic probabilistic maps. Korean J Nucl Med. 2004;38:241–52.
61.
go back to reference Choi JY, Lee KH, Na DL, Byun HS, Lee SJ, Kim H, et al. Subcortical aphasia after striatocapsular infarction: quantitative analysis of brain perfusion SPECT using statistical parametric mapping and a statistical probabilistic anatomic map. J Nucl Med. 2007;48:194–200.PubMed Choi JY, Lee KH, Na DL, Byun HS, Lee SJ, Kim H, et al. Subcortical aphasia after striatocapsular infarction: quantitative analysis of brain perfusion SPECT using statistical parametric mapping and a statistical probabilistic anatomic map. J Nucl Med. 2007;48:194–200.PubMed
62.
go back to reference Lee JS, Lee DS, Kim SK, Lee SK, Chung JK, Lee MC, et al. Localization of epileptogenic zones in F-18 FDG brain PET of patients with temporal lobe epilepsy using artificial neural network. IEEE Trans Med Imaging. 2000;19:347–55.PubMedCrossRef Lee JS, Lee DS, Kim SK, Lee SK, Chung JK, Lee MC, et al. Localization of epileptogenic zones in F-18 FDG brain PET of patients with temporal lobe epilepsy using artificial neural network. IEEE Trans Med Imaging. 2000;19:347–55.PubMedCrossRef
63.
go back to reference Lee JS, Park KS, Lee DS, Lee CW, Chung JK, Lee MC. Development and applications of a software for Functional Image Registration (FIRE). Comput Methods Programs Biomed. 2005;78:157–64.PubMedCrossRef Lee JS, Park KS, Lee DS, Lee CW, Chung JK, Lee MC. Development and applications of a software for Functional Image Registration (FIRE). Comput Methods Programs Biomed. 2005;78:157–64.PubMedCrossRef
64.
go back to reference Park HJ, Kim JJ, Youn T, Lee DS, Lee MC, Kwon JS. Independent component model for cognitive functions of multiple subjects using [15O]H2O PET images. Hum Brain Mapp. 2003;18:284–95.PubMedPubMedCentralCrossRef Park HJ, Kim JJ, Youn T, Lee DS, Lee MC, Kwon JS. Independent component model for cognitive functions of multiple subjects using [15O]H2O PET images. Hum Brain Mapp. 2003;18:284–95.PubMedPubMedCentralCrossRef
65.
go back to reference Park H-J, Kubicki M, Shenton ME, Guimond A, McCarley RW, Maier SE, et al. Spatial normalization of diffusion tensor MRI using multiple channels. Neuroimage. 2003;20:1995–2009.PubMedCrossRef Park H-J, Kubicki M, Shenton ME, Guimond A, McCarley RW, Maier SE, et al. Spatial normalization of diffusion tensor MRI using multiple channels. Neuroimage. 2003;20:1995–2009.PubMedCrossRef
66.
go back to reference Oh JS, Song IC, Lee JS, Kang H, Park KS, Kang E, et al. Tractography-guided statistics (TGIS) in diffusion tensor imaging for the detection of gender difference of fiber integrity in the midsagittal and parasagittal corpora callosa. Neuroimage. 2007;36:606–16.PubMedCrossRef Oh JS, Song IC, Lee JS, Kang H, Park KS, Kang E, et al. Tractography-guided statistics (TGIS) in diffusion tensor imaging for the detection of gender difference of fiber integrity in the midsagittal and parasagittal corpora callosa. Neuroimage. 2007;36:606–16.PubMedCrossRef
67.
go back to reference Park HJ, Lee JD, Chun JW, Seok JH, Yun M, Oh MK, et al. Cortical surface-based analysis of 18F-FDG PET: measured metabolic abnormalities in schizophrenia are affected by cortical structural abnormalities. Neuroimage. 2006;31:1434–44.PubMedCrossRef Park HJ, Lee JD, Chun JW, Seok JH, Yun M, Oh MK, et al. Cortical surface-based analysis of 18F-FDG PET: measured metabolic abnormalities in schizophrenia are affected by cortical structural abnormalities. Neuroimage. 2006;31:1434–44.PubMedCrossRef
68.
go back to reference Oh JS, Oh M, Chung SJ, Kim JS. Cerebellum-specific 18F-FDG PET analysis for the detection of subregional glucose metabolism changes in spinocerebellar ataxia. NeuroReport. 2014;25:1198–202.PubMedCrossRef Oh JS, Oh M, Chung SJ, Kim JS. Cerebellum-specific 18F-FDG PET analysis for the detection of subregional glucose metabolism changes in spinocerebellar ataxia. NeuroReport. 2014;25:1198–202.PubMedCrossRef
69.
go back to reference Lee JD, Park HJ, Park ES, Kim DG, Rha DW, Kim EY, et al. Assessment of regional GABA(A) receptor binding using 18F-fluoroflumazenil positron emission tomography in spastic type cerebral palsy. Neuroimage. 2007;34:19–25.PubMedCrossRef Lee JD, Park HJ, Park ES, Kim DG, Rha DW, Kim EY, et al. Assessment of regional GABA(A) receptor binding using 18F-fluoroflumazenil positron emission tomography in spastic type cerebral palsy. Neuroimage. 2007;34:19–25.PubMedCrossRef
70.
go back to reference Son HJ, Oh JS, Roh JH, Seo SW, Oh M, Lee SJ, et al. Differences in gray and white matter (18)F-THK5351 uptake between behavioral-variant frontotemporal dementia and other dementias. Eur J Nucl Med Mol Imaging. 2019;46:357–66.PubMedCrossRef Son HJ, Oh JS, Roh JH, Seo SW, Oh M, Lee SJ, et al. Differences in gray and white matter (18)F-THK5351 uptake between behavioral-variant frontotemporal dementia and other dementias. Eur J Nucl Med Mol Imaging. 2019;46:357–66.PubMedCrossRef
71.
go back to reference Kim JS, Lee JS, Park MH, Kang H, Lee JJ, Lee HJ, et al. Assessment of cerebral glucose metabolism in cat deafness model: strategies for improving the voxel-based statistical analysis for animal PET studies. Mol Imaging Biol. 2008;10:154–61.PubMedCrossRef Kim JS, Lee JS, Park MH, Kang H, Lee JJ, Lee HJ, et al. Assessment of cerebral glucose metabolism in cat deafness model: strategies for improving the voxel-based statistical analysis for animal PET studies. Mol Imaging Biol. 2008;10:154–61.PubMedCrossRef
72.
go back to reference Kim JS, Lee JS, Park MH, Kim KM, Oh SH, Cheon GJ, et al. Feasibility of template-guided attenuation correction in cat brain PET imaging. Mol Imaging Biol. 2010;12:250–8.PubMedCrossRef Kim JS, Lee JS, Park MH, Kim KM, Oh SH, Cheon GJ, et al. Feasibility of template-guided attenuation correction in cat brain PET imaging. Mol Imaging Biol. 2010;12:250–8.PubMedCrossRef
73.
go back to reference Woo SK, Lee TS, Kim KM, Kim JY, Jung JH, Kang JH, et al. Anesthesia condition for (18)F-FDG imaging of lung metastasis tumors using small animal PET. Nucl Med Biol. 2008;35:143–50.PubMedCrossRef Woo SK, Lee TS, Kim KM, Kim JY, Jung JH, Kang JH, et al. Anesthesia condition for (18)F-FDG imaging of lung metastasis tumors using small animal PET. Nucl Med Biol. 2008;35:143–50.PubMedCrossRef
74.
go back to reference Kim JS, Yu AR, Kim KM, Oh SJ, Ryu JS, Kim HJ, et al. Validation of a postinjection transmission method for actual rat brain PET. Med Phys. 2012;39:5614–20.PubMedCrossRef Kim JS, Yu AR, Kim KM, Oh SJ, Ryu JS, Kim HJ, et al. Validation of a postinjection transmission method for actual rat brain PET. Med Phys. 2012;39:5614–20.PubMedCrossRef
75.
go back to reference Chung YH, Choi Y, Cho G, Choe YS, Lee KH, Kim BT. Characterization of dual layer phoswich detector performance for small animal PET using Monte Carlo simulation. Phys Med Biol. 2004;49:2881–90.PubMedCrossRef Chung YH, Choi Y, Cho G, Choe YS, Lee KH, Kim BT. Characterization of dual layer phoswich detector performance for small animal PET using Monte Carlo simulation. Phys Med Biol. 2004;49:2881–90.PubMedCrossRef
76.
go back to reference Jeong MH, Choi Y, Chung YH, Song TY, Jung JH, Hong KJ, et al. Performance improvement of small gamma camera using NaI(Tl) plate and position sensitive photo-multiplier tubes. Phys Med Biol. 2004;49:4961–70.PubMedCrossRef Jeong MH, Choi Y, Chung YH, Song TY, Jung JH, Hong KJ, et al. Performance improvement of small gamma camera using NaI(Tl) plate and position sensitive photo-multiplier tubes. Phys Med Biol. 2004;49:4961–70.PubMedCrossRef
77.
go back to reference Song TY, Choi Y, Jung JH, Min BJ, Hong KJ, Choe YS, et al. Performance amelioration for small animal SPECT using optimized pinhole collimator and image correction technique. IEEE Trans Nucl Sci. 2005;52:1396–400.CrossRef Song TY, Choi Y, Jung JH, Min BJ, Hong KJ, Choe YS, et al. Performance amelioration for small animal SPECT using optimized pinhole collimator and image correction technique. IEEE Trans Nucl Sci. 2005;52:1396–400.CrossRef
78.
go back to reference Chung YH, Choi Y, Cho G, Choe YS, Lee K-H, Kim B-T. Optimization of dual layer phoswich detector consisting of LSO and LuYAP for small animal PET. IEEE Trans Nucl Sci. 2005;52:217–21.CrossRef Chung YH, Choi Y, Cho G, Choe YS, Lee K-H, Kim B-T. Optimization of dual layer phoswich detector consisting of LSO and LuYAP for small animal PET. IEEE Trans Nucl Sci. 2005;52:217–21.CrossRef
79.
go back to reference Kim JS, Lee JS, Im KC, Kim SJ, Kim SY, Lee DS, et al. Performance measurement of the microPET focus 120 scanner. J Nucl Med. 2007;48:1527–35.PubMedCrossRef Kim JS, Lee JS, Im KC, Kim SJ, Kim SY, Lee DS, et al. Performance measurement of the microPET focus 120 scanner. J Nucl Med. 2007;48:1527–35.PubMedCrossRef
80.
go back to reference Lee BI, Lee JS, Kim JS, Lee DS, Choi CU, Lim SM. Performance characteristics of microPET R4 scanner for small animal imaging. Korean J Nucl Med. 2005;39:49–56. Lee BI, Lee JS, Kim JS, Lee DS, Choi CU, Lim SM. Performance characteristics of microPET R4 scanner for small animal imaging. Korean J Nucl Med. 2005;39:49–56.
81.
go back to reference Ito M, Lee JS, Kwon SI, Lee GS, Hong B, Lee KS, et al. A four-layer DOI detector with a relative offset for use in an animal PET system. IEEE Trans Nucl Sci. 2010;57:976–81.CrossRef Ito M, Lee JS, Kwon SI, Lee GS, Hong B, Lee KS, et al. A four-layer DOI detector with a relative offset for use in an animal PET system. IEEE Trans Nucl Sci. 2010;57:976–81.CrossRef
82.
go back to reference Ito M, Lee JS, Park MJ, Sim KS, Hong SJ. Design and simulation of a novel method for determining depth-of-interaction in a PET scintillation crystal array using a single-ended readout by a multi-anode PMT. Phys Med Biol. 2010;55:3827–41.PubMedCrossRef Ito M, Lee JS, Park MJ, Sim KS, Hong SJ. Design and simulation of a novel method for determining depth-of-interaction in a PET scintillation crystal array using a single-ended readout by a multi-anode PMT. Phys Med Biol. 2010;55:3827–41.PubMedCrossRef
83.
go back to reference Hong SJ, Kwon SI, Ito M, Lee GS, Sim K-S, Park KS, et al. Concept verification of three-layer DOI detectors for small animal PET. IEEE Trans Nucl Sci. 2008;55:912–7.CrossRef Hong SJ, Kwon SI, Ito M, Lee GS, Sim K-S, Park KS, et al. Concept verification of three-layer DOI detectors for small animal PET. IEEE Trans Nucl Sci. 2008;55:912–7.CrossRef
84.
go back to reference Lee CM, Hong SJ, Yoon HS, Ito M, Kwon S, Park SK, et al. Spatial and energy resolutions of a hexagonal animal PET scanner based on LGSO crystal and flat-panel PMT. Nucl Eng Technol. 2012;44:53–60.CrossRef Lee CM, Hong SJ, Yoon HS, Ito M, Kwon S, Park SK, et al. Spatial and energy resolutions of a hexagonal animal PET scanner based on LGSO crystal and flat-panel PMT. Nucl Eng Technol. 2012;44:53–60.CrossRef
85.
go back to reference Yoon HS, Lee CM, Ito M, Kwon SI, Kim SM, Ko GB, et al. Breast-dedicated positron emission tomography systems. J Biomed Eng Res. 2010;31:259–68. Yoon HS, Lee CM, Ito M, Kwon SI, Kim SM, Ko GB, et al. Breast-dedicated positron emission tomography systems. J Biomed Eng Res. 2010;31:259–68.
86.
go back to reference Ito M, Hong SJ, Lee JS. Positron emission tomography (PET) detectors with depth-of-interaction (DOI) capability. Biomed Eng Lett. 2011;1:70–81.CrossRef Ito M, Hong SJ, Lee JS. Positron emission tomography (PET) detectors with depth-of-interaction (DOI) capability. Biomed Eng Lett. 2011;1:70–81.CrossRef
87.
go back to reference Chung YH, Baek C-H, Lee S-J, Hong KJ, Kang JH, Choi Y. Preliminary experimental results of a quasi-monolithic detector with DOI capability for a small animal PET. Nucl Instrum Meth A. 2010;621:590–4.CrossRef Chung YH, Baek C-H, Lee S-J, Hong KJ, Kang JH, Choi Y. Preliminary experimental results of a quasi-monolithic detector with DOI capability for a small animal PET. Nucl Instrum Meth A. 2010;621:590–4.CrossRef
88.
go back to reference Chung YH, Lee S-J, Baek C-H, Choi Y. New design of a quasi-monolithic detector module with DOI capability for small animal PET. Nucl Instrum Meth A. 2008;593:588–91.CrossRef Chung YH, Lee S-J, Baek C-H, Choi Y. New design of a quasi-monolithic detector module with DOI capability for small animal PET. Nucl Instrum Meth A. 2008;593:588–91.CrossRef
89.
go back to reference Ito M, Lee MS, Lee JS. Continuous depth-of-interaction measurement in a single-layer pixelated crystal array using a single-ended readout. Phys Med Biol. 2013;58:1269–82.PubMedCrossRef Ito M, Lee MS, Lee JS. Continuous depth-of-interaction measurement in a single-layer pixelated crystal array using a single-ended readout. Phys Med Biol. 2013;58:1269–82.PubMedCrossRef
90.
go back to reference Lee MS, Kim KY, Ko GB, Lee JS. Prototype pre-clinical PET scanner with depth-of-interaction measurements using single-layer crystal array and single-ended readout. Phys Med Biol. 2017;62:3983–96.PubMedCrossRef Lee MS, Kim KY, Ko GB, Lee JS. Prototype pre-clinical PET scanner with depth-of-interaction measurements using single-layer crystal array and single-ended readout. Phys Med Biol. 2017;62:3983–96.PubMedCrossRef
91.
go back to reference Lee MS, Lee JS. Depth-of-interaction measurement in a single-layer crystal array with a single-ended readout using digital silicon photomultiplier. Phys Med Biol. 2015;60:6495–514.PubMedCrossRef Lee MS, Lee JS. Depth-of-interaction measurement in a single-layer crystal array with a single-ended readout using digital silicon photomultiplier. Phys Med Biol. 2015;60:6495–514.PubMedCrossRef
92.
go back to reference Kim SM, Lee JS, Lee CS, Kim CH, Lee MC, Lee DS, et al. Fully three-dimensional OSEM-based image reconstruction for Compton imaging using optimized ordering schemes. Phys Med Biol. 2010;55:5007–27.PubMedCrossRef Kim SM, Lee JS, Lee CS, Kim CH, Lee MC, Lee DS, et al. Fully three-dimensional OSEM-based image reconstruction for Compton imaging using optimized ordering schemes. Phys Med Biol. 2010;55:5007–27.PubMedCrossRef
93.
go back to reference Kim SM, Seo H, Park JH, Kim CH, Lee CS, Lee SJ, et al. Resolution recovery reconstruction for a Compton camera. Phys Med Biol. 2013;58:2823–40.PubMedCrossRef Kim SM, Seo H, Park JH, Kim CH, Lee CS, Lee SJ, et al. Resolution recovery reconstruction for a Compton camera. Phys Med Biol. 2013;58:2823–40.PubMedCrossRef
94.
go back to reference An S, Seo H, Lee J, Lee C, Lee J, Kim CH. Effect of detector parameters on the image quality of Compton camera for 99mTc. Nucl Instrum Meth A. 2007;571:251–4.CrossRef An S, Seo H, Lee J, Lee C, Lee J, Kim CH. Effect of detector parameters on the image quality of Compton camera for 99mTc. Nucl Instrum Meth A. 2007;571:251–4.CrossRef
95.
go back to reference Seo H, Kim CH, Park JH, Kim JK, Lee JH, Lee CS, et al. Development of double-scattering-type Compton camera with double-sided silicon strip detectors and NaI(Tl) scintillation detector. Nucl Instrum Meth A. 2010;615:333–9.CrossRef Seo H, Kim CH, Park JH, Kim JK, Lee JH, Lee CS, et al. Development of double-scattering-type Compton camera with double-sided silicon strip detectors and NaI(Tl) scintillation detector. Nucl Instrum Meth A. 2010;615:333–9.CrossRef
96.
go back to reference Kang J, Choi Y, Hong KJ, Hu W, Jung JH, Huh Y, et al. A small animal PET based on GAPDs and charge signal transmission approach for hybrid PET-MR imaging. J Inst. 2011;6:P08012. Kang J, Choi Y, Hong KJ, Hu W, Jung JH, Huh Y, et al. A small animal PET based on GAPDs and charge signal transmission approach for hybrid PET-MR imaging. J Inst. 2011;6:P08012.
97.
go back to reference Kang J, Choi Y, Hong KJ, Jung JH, Hu W, Huh YS, et al. A feasibility study of photosensor charge signal transmission to preamplifier using long cable for development of hybrid PET-MRI. Med Phys. 2010;37:5655–64.PubMedCrossRef Kang J, Choi Y, Hong KJ, Jung JH, Hu W, Huh YS, et al. A feasibility study of photosensor charge signal transmission to preamplifier using long cable for development of hybrid PET-MRI. Med Phys. 2010;37:5655–64.PubMedCrossRef
98.
go back to reference Kwon SI, Lee JS, Yoon HS, Ito M, Ko GB, Choi JY, et al. Development of small-animal PET prototype using silicon photomultiplier (SiPM): initial results of phantom and animal imaging studies. J Nucl Med. 2011;52:572–9.PubMedCrossRef Kwon SI, Lee JS, Yoon HS, Ito M, Ko GB, Choi JY, et al. Development of small-animal PET prototype using silicon photomultiplier (SiPM): initial results of phantom and animal imaging studies. J Nucl Med. 2011;52:572–9.PubMedCrossRef
99.
go back to reference Lee JS, Hong SJ. Geiger-mode avalanche photodiodes for PET/MRI Electronics for Radiation Detection. FL: CRC Press Boca Raton; 2010. p. 179–98. Lee JS, Hong SJ. Geiger-mode avalanche photodiodes for PET/MRI Electronics for Radiation Detection. FL: CRC Press Boca Raton; 2010. p. 179–98.
100.
go back to reference Lee JS, Ito M, Sim K, Hong B, Lee KS, Muhammad J, et al. Investigation of solid-state photomultipliers for positron emission tomography scanners. J Korean Phys Soc. 2007;50:1332–9.CrossRef Lee JS, Ito M, Sim K, Hong B, Lee KS, Muhammad J, et al. Investigation of solid-state photomultipliers for positron emission tomography scanners. J Korean Phys Soc. 2007;50:1332–9.CrossRef
101.
go back to reference Hong SJ, Song IC, Ito M, Kwon SI, Lee GS, Sim K-S, et al. An investigation into the use of Geiger-mode solid-state photomultipliers for simultaneous PET and MRI acquisition. IEEE Trans Nucl Sci. 2008;55:882–8.CrossRef Hong SJ, Song IC, Ito M, Kwon SI, Lee GS, Sim K-S, et al. An investigation into the use of Geiger-mode solid-state photomultipliers for simultaneous PET and MRI acquisition. IEEE Trans Nucl Sci. 2008;55:882–8.CrossRef
102.
go back to reference Jung JH, Choi Y, Hong KJ, Hu W, Kang JH, Min BJ, et al. Development of a position decoder circuit for PET consisting of GAPD arrays. Nucl Instrum Meth A. 2010;621:310–5.CrossRef Jung JH, Choi Y, Hong KJ, Hu W, Kang JH, Min BJ, et al. Development of a position decoder circuit for PET consisting of GAPD arrays. Nucl Instrum Meth A. 2010;621:310–5.CrossRef
103.
go back to reference Kwon SI, Hong SJ, Ito M, Yoon HS, Song IC, Lee JS. Development of SSPM-PET with digitally controlled bias voltage supply. J Nucl Med. 2009;50(supplement 2):355. Kwon SI, Hong SJ, Ito M, Yoon HS, Song IC, Lee JS. Development of SSPM-PET with digitally controlled bias voltage supply. J Nucl Med. 2009;50(supplement 2):355.
104.
go back to reference Yoon HS, Ko GB, Kwon SI, Lee CM, Ito M, Song IC, et al. Simultaneous PET/MR imaging with a MR-compatible SiPM PET scanner. J Nucl Med. 2011;52(supplement 1):258. Yoon HS, Ko GB, Kwon SI, Lee CM, Ito M, Song IC, et al. Simultaneous PET/MR imaging with a MR-compatible SiPM PET scanner. J Nucl Med. 2011;52(supplement 1):258.
105.
go back to reference Yoon HS, Ko GB, Kwon SI, Lee CM, Ito M, Song IC, et al. Initial results of simultaneous PET/MRI experiments with an MRI-compatible silicon photomultiplier PET scanner. J Nucl Med. 2012;53:608–14.PubMedCrossRef Yoon HS, Ko GB, Kwon SI, Lee CM, Ito M, Song IC, et al. Initial results of simultaneous PET/MRI experiments with an MRI-compatible silicon photomultiplier PET scanner. J Nucl Med. 2012;53:608–14.PubMedCrossRef
106.
go back to reference Cho G, Kim H, Sul WS, Lee C, Kang B-S. Optimum design of quenching capacitor integrated silicon photomultipliers for TOF-PET application. Phys Procedia. 2012;37:1511–7.CrossRef Cho G, Kim H, Sul WS, Lee C, Kang B-S. Optimum design of quenching capacitor integrated silicon photomultipliers for TOF-PET application. Phys Procedia. 2012;37:1511–7.CrossRef
107.
go back to reference Sul W-S, Kim H, Cho G. Silicon photomultiplier modules for MRI-compatible PET. J Inst. 2015;10:C04002. Sul W-S, Kim H, Cho G. Silicon photomultiplier modules for MRI-compatible PET. J Inst. 2015;10:C04002.
108.
go back to reference Hong KJ, Choi Y, Jung JH, Kang J, Hu W, Lim HK, et al. A prototype MR insertable brain PET using tileable GAPD arrays. Med Phys. 2013;40:042503 Hong KJ, Choi Y, Jung JH, Kang J, Hu W, Lim HK, et al. A prototype MR insertable brain PET using tileable GAPD arrays. Med Phys. 2013;40:042503
109.
go back to reference Jung JH, Choi Y, Jung J, Kim S, Lim HK, Im KC, et al. Development of PET/MRI with insertable PET for simultaneous PET and MR imaging of human brain. Med Phys. 2015;42:2354–63.PubMedCrossRef Jung JH, Choi Y, Jung J, Kim S, Lim HK, Im KC, et al. Development of PET/MRI with insertable PET for simultaneous PET and MR imaging of human brain. Med Phys. 2015;42:2354–63.PubMedCrossRef
110.
go back to reference Oh C, Han Y, Kim D, Lim H, Choi Y, Cho G, et al. An optimal RF shielding method for MR-PET fusion system with insertable PET. Int J Imaging Syst Technol. 2014;24:263–9.CrossRef Oh C, Han Y, Kim D, Lim H, Choi Y, Cho G, et al. An optimal RF shielding method for MR-PET fusion system with insertable PET. Int J Imaging Syst Technol. 2014;24:263–9.CrossRef
111.
go back to reference Ko GB, Yoon HS, Kim KY, Lee MS, Yang BY, Jeong JM, et al. Simultaneous multiparametric PET/MRI with silicon photomultiplier PET and ultra-high-field MRI for small-animal imaging. J Nucl Med. 2016;57:1309–15.PubMedCrossRef Ko GB, Yoon HS, Kim KY, Lee MS, Yang BY, Jeong JM, et al. Simultaneous multiparametric PET/MRI with silicon photomultiplier PET and ultra-high-field MRI for small-animal imaging. J Nucl Med. 2016;57:1309–15.PubMedCrossRef
112.
go back to reference Ko GB, Kim KY, Yoon HS, Lee MS, Son JW, Im HJ, et al. Evaluation of a silicon photomultiplier PET insert for simultaneous PET and MR imaging. Med Phys. 2016;43:72.PubMedCrossRef Ko GB, Kim KY, Yoon HS, Lee MS, Son JW, Im HJ, et al. Evaluation of a silicon photomultiplier PET insert for simultaneous PET and MR imaging. Med Phys. 2016;43:72.PubMedCrossRef
113.
go back to reference Lee S, Choi Y, Jung JH, Jung J, Kim KB, Choe HJ, et al. Performance evaluation of a small animal PET scanner a high level of multiplexing and charge-signal transmission. Phys Med Biol. 2019;64:045015 Lee S, Choi Y, Jung JH, Jung J, Kim KB, Choe HJ, et al. Performance evaluation of a small animal PET scanner a high level of multiplexing and charge-signal transmission. Phys Med Biol. 2019;64:045015
114.
go back to reference Cho ZH, Son YD, Kim HK, Kwon DH, Joo YH, Ra JB, et al. Development of positron emission tomography with wobbling and zooming for high sensitivity and high-resolution molecular imaging. IEEE Trans Med Imaging. 2019;38:2875–82.PubMedCrossRef Cho ZH, Son YD, Kim HK, Kwon DH, Joo YH, Ra JB, et al. Development of positron emission tomography with wobbling and zooming for high sensitivity and high-resolution molecular imaging. IEEE Trans Med Imaging. 2019;38:2875–82.PubMedCrossRef
115.
go back to reference Son JW, Kim KY, Yoon HS, Won JY, Ko GB, Lee MS, et al. Proof-of-concept prototype time-of-flight PET system based on high-quantum-efficiency multianode PMTs. Med Phys. 2017;44:5314–24.PubMedCrossRef Son JW, Kim KY, Yoon HS, Won JY, Ko GB, Lee MS, et al. Proof-of-concept prototype time-of-flight PET system based on high-quantum-efficiency multianode PMTs. Med Phys. 2017;44:5314–24.PubMedCrossRef
116.
go back to reference Won JY, Ko GB, Kim KY, Park H, Lee S, Son JW, et al. Comparator-less PET data acquisition system using single-ended memory interface input receivers of FPGA. Phys Med Biol. 2020;65:155007 Won JY, Ko GB, Kim KY, Park H, Lee S, Son JW, et al. Comparator-less PET data acquisition system using single-ended memory interface input receivers of FPGA. Phys Med Biol. 2020;65:155007
117.
go back to reference Won JY, Park H, Lee S, Son JW, Chung Y, Ko GB, et al. Development and initial results of a brain PET insert for simultaneous 7-Tesla PET/MRI using an FPGA-only signal digitization method. IEEE Trans Med Imaging. 2021;40:1579–90.PubMedCrossRef Won JY, Park H, Lee S, Son JW, Chung Y, Ko GB, et al. Development and initial results of a brain PET insert for simultaneous 7-Tesla PET/MRI using an FPGA-only signal digitization method. IEEE Trans Med Imaging. 2021;40:1579–90.PubMedCrossRef
118.
go back to reference Choe H-J, Choi Y, Kwak DJ, Lee J. Prototype time-of-flight PET utilizing capacitive multiplexing readout method. Nucl Instrum Meth A. 2019;921:43–9.CrossRef Choe H-J, Choi Y, Kwak DJ, Lee J. Prototype time-of-flight PET utilizing capacitive multiplexing readout method. Nucl Instrum Meth A. 2019;921:43–9.CrossRef
119.
go back to reference Hong SJ, Kang HG, Ko GB, Song IC, Rhee JT, Lee JS. SiPM-PET with a short optical fiber bundle for simultaneous PET-MR imaging. Phys Med Biol. 2012;57:3869–83.PubMedCrossRef Hong SJ, Kang HG, Ko GB, Song IC, Rhee JT, Lee JS. SiPM-PET with a short optical fiber bundle for simultaneous PET-MR imaging. Phys Med Biol. 2012;57:3869–83.PubMedCrossRef
120.
go back to reference Han YB, Song SH, Kang HG, Lee HY, Hong SJ. SiPM-based gamma detector with a central GRIN lens for a visible/NIRF/gamma multi-modal laparoscope. Opt Express. 2021;29:2364–77.PubMedCrossRef Han YB, Song SH, Kang HG, Lee HY, Hong SJ. SiPM-based gamma detector with a central GRIN lens for a visible/NIRF/gamma multi-modal laparoscope. Opt Express. 2021;29:2364–77.PubMedCrossRef
121.
go back to reference Kang HG, Lee HY, Kim KM, Song SH, Hong GC, Hong SJ. A feasibility study of an integrated NIR/gamma/visible imaging system for endoscopic sentinel lymph node mapping. Med Phys. 2017;44:227–39.PubMedCrossRef Kang HG, Lee HY, Kim KM, Song SH, Hong GC, Hong SJ. A feasibility study of an integrated NIR/gamma/visible imaging system for endoscopic sentinel lymph node mapping. Med Phys. 2017;44:227–39.PubMedCrossRef
122.
go back to reference Kang HG, Song SH, Han YB, Lee HY, Kim KM, Hong SJ. Proof-of-concept of a multimodal laparoscope for simultaneous NIR/gamma/visible imaging using wavelength division multiplexing. Opt Express. 2018;26:8325–39.PubMedCrossRef Kang HG, Song SH, Han YB, Lee HY, Kim KM, Hong SJ. Proof-of-concept of a multimodal laparoscope for simultaneous NIR/gamma/visible imaging using wavelength division multiplexing. Opt Express. 2018;26:8325–39.PubMedCrossRef
123.
go back to reference Park C, Kim C, Kim J, Lee Y, Na Y, Lee K, et al. Performance comparison between ceramic Ce:GAGG and single crystal Ce:GAGG with digital-SiPM. J Inst. 2017;12:P01002. Park C, Kim C, Kim J, Lee Y, Na Y, Lee K, et al. Performance comparison between ceramic Ce:GAGG and single crystal Ce:GAGG with digital-SiPM. J Inst. 2017;12:P01002.
124.
go back to reference Ullah MN, Pratiwi E, Park JH, Yamamoto S, Kamada K, Yoshikawa A, et al. Studies on sub-millimeter LYSO: Ce, Ce: GAGG, and a new Ce: GFAG block detector for PET using digital silicon photomultiplier. Nucl Instrum Meth A. 2018;911:115–22.CrossRef Ullah MN, Pratiwi E, Park JH, Yamamoto S, Kamada K, Yoshikawa A, et al. Studies on sub-millimeter LYSO: Ce, Ce: GAGG, and a new Ce: GFAG block detector for PET using digital silicon photomultiplier. Nucl Instrum Meth A. 2018;911:115–22.CrossRef
125.
go back to reference Ullah MN, Park C, Pratiwi E, Kim C, Choi H, Yeom J-Y. A new positron-gamma discriminating phoswich detector based on wavelength discrimination (WLD). Nucl Instrum Meth A. 2019;946:162631 Ullah MN, Park C, Pratiwi E, Kim C, Choi H, Yeom J-Y. A new positron-gamma discriminating phoswich detector based on wavelength discrimination (WLD). Nucl Instrum Meth A. 2019;946:162631
126.
go back to reference Ullah MN, Pratiwi E, Park JH, Lee K, Choi H, Yeom J-Y. Wavelength discrimination (WLD) TOF-PET detector with DOI information. Phys Med Biol. 2020;65:055003 Ullah MN, Pratiwi E, Park JH, Lee K, Choi H, Yeom J-Y. Wavelength discrimination (WLD) TOF-PET detector with DOI information. Phys Med Biol. 2020;65:055003
127.
go back to reference Bae S, Bae J, Lee H, Lee K. Development of correction methods for variable pinhole single-photon emission computed tomography. J Inst. 2016;11:C02060. Bae S, Bae J, Lee H, Lee K. Development of correction methods for variable pinhole single-photon emission computed tomography. J Inst. 2016;11:C02060.
128.
go back to reference Bae S, Chun J, Cha H, Yeom JY, Lee K, Lee H. Simulation study of a novel target oriented SPECT design using a variable pinhole collimator. Med Phys. 2017;44:470–8.PubMedCrossRef Bae S, Chun J, Cha H, Yeom JY, Lee K, Lee H. Simulation study of a novel target oriented SPECT design using a variable pinhole collimator. Med Phys. 2017;44:470–8.PubMedCrossRef
129.
go back to reference Cha H, Cho K, Jung Y-J, Bae S, Kim KM, Kim M, et al. Development of organ-specific dual-head single-photon emission computed tomography using variable pinhole collimator. Nucl Instrum Meth A. 2021;987:164822 Cha H, Cho K, Jung Y-J, Bae S, Kim KM, Kim M, et al. Development of organ-specific dual-head single-photon emission computed tomography using variable pinhole collimator. Nucl Instrum Meth A. 2021;987:164822
130.
go back to reference Oh JS, Kang BC, Roh JL, Kim JS, Cho KJ, Lee SW, et al. Intratumor textural heterogeneity on pretreatment (18)F-FDG PET images predicts response and survival after chemoradiotherapy for hypopharyngeal cancer. Ann Surg Oncol. 2015;22:2746–54.PubMedCrossRef Oh JS, Kang BC, Roh JL, Kim JS, Cho KJ, Lee SW, et al. Intratumor textural heterogeneity on pretreatment (18)F-FDG PET images predicts response and survival after chemoradiotherapy for hypopharyngeal cancer. Ann Surg Oncol. 2015;22:2746–54.PubMedCrossRef
131.
go back to reference Son HJ, Oh JS, Oh M, Kim SJ, Lee JH, Roh JH, et al. The clinical feasibility of deep learning-based classification of amyloid PET images in visually equivocal cases. Eur J Nucl Med Mol Imaging. 2020;47:332–41.PubMedCrossRef Son HJ, Oh JS, Oh M, Kim SJ, Lee JH, Roh JH, et al. The clinical feasibility of deep learning-based classification of amyloid PET images in visually equivocal cases. Eur J Nucl Med Mol Imaging. 2020;47:332–41.PubMedCrossRef
132.
go back to reference Kim KY, Son JW, Kim K, Chung Y, Park JY, Lee YS, et al. Performance evaluation of SimPET-X, a PET insert for simultaneous mouse total-body PET/MR imaging. Mol Imaging Biol. 2021 Kim KY, Son JW, Kim K, Chung Y, Park JY, Lee YS, et al. Performance evaluation of SimPET-X, a PET insert for simultaneous mouse total-body PET/MR imaging. Mol Imaging Biol. 2021
133.
go back to reference Son JW, Kim KY, Park JY, Kim K, Lee YS, Ko GB, et al. SimPET: a preclinical PET insert for simultaneous PET/MR imaging. Mol Imaging Biol. 2020;22:1208–17.PubMedCrossRef Son JW, Kim KY, Park JY, Kim K, Lee YS, Ko GB, et al. SimPET: a preclinical PET insert for simultaneous PET/MR imaging. Mol Imaging Biol. 2020;22:1208–17.PubMedCrossRef
134.
go back to reference Choi H, Cheon GJ, Kim H-J, Choi SH, Lee JS, Kim Y-I, et al. Segmentation-based MR attenuation correction including bones also affects quantitation in brain studies: an initial result of 18F-FP-CIT PET/MR for patients with parkinsonism. J Nucl Med. 2014;55:1617–22.PubMedCrossRef Choi H, Cheon GJ, Kim H-J, Choi SH, Lee JS, Kim Y-I, et al. Segmentation-based MR attenuation correction including bones also affects quantitation in brain studies: an initial result of 18F-FP-CIT PET/MR for patients with parkinsonism. J Nucl Med. 2014;55:1617–22.PubMedCrossRef
135.
go back to reference Kim JH, Lee JS, Song I-C, Lee DS. Comparison of segmentation-based attenuation correction methods for PET/MRI: evaluation of bone and liver standardized uptake value with oncologic PET/CT data. J Nucl Med. 2012;53:1878–82.PubMedCrossRef Kim JH, Lee JS, Song I-C, Lee DS. Comparison of segmentation-based attenuation correction methods for PET/MRI: evaluation of bone and liver standardized uptake value with oncologic PET/CT data. J Nucl Med. 2012;53:1878–82.PubMedCrossRef
137.
go back to reference An HJ, Seo S, Kang H, Choi H, Cheon GJ, Kim H-J, et al. MRI-based attenuation correction for PET/MRI using multiphase level-set method. J Nucl Med. 2016;57:587–93.PubMedCrossRef An HJ, Seo S, Kang H, Choi H, Cheon GJ, Kim H-J, et al. MRI-based attenuation correction for PET/MRI using multiphase level-set method. J Nucl Med. 2016;57:587–93.PubMedCrossRef
138.
go back to reference Hwang D, Kang SK, Kim KY, Seo S, Paeng JC, Lee DS, et al. Generation of PET attenuation map for whole-body time-of-flight 18F-FDG PET/MRI using a deep neural network trained with simultaneously reconstructed activity and attenuation maps. J Nucl Med. 2019;60:1183–9.PubMedPubMedCentralCrossRef Hwang D, Kang SK, Kim KY, Seo S, Paeng JC, Lee DS, et al. Generation of PET attenuation map for whole-body time-of-flight 18F-FDG PET/MRI using a deep neural network trained with simultaneously reconstructed activity and attenuation maps. J Nucl Med. 2019;60:1183–9.PubMedPubMedCentralCrossRef
139.
go back to reference Hwang D, Kim KY, Kang SK, Seo S, Paeng JC, Lee DS, et al. Improving the accuracy of simultaneously reconstructed activity and attenuation maps using deep learning. J Nucl Med. 2018;59:1624–9.PubMedCrossRef Hwang D, Kim KY, Kang SK, Seo S, Paeng JC, Lee DS, et al. Improving the accuracy of simultaneously reconstructed activity and attenuation maps using deep learning. J Nucl Med. 2018;59:1624–9.PubMedCrossRef
140.
go back to reference Hwang D, Kang SK, Kim KY, Choi H, Seo S, Lee JS. Data-driven respiratory phase-matched PET attenuation correction without CT. Phys Med Biol. 2021;66:115009 Hwang D, Kang SK, Kim KY, Choi H, Seo S, Lee JS. Data-driven respiratory phase-matched PET attenuation correction without CT. Phys Med Biol. 2021;66:115009
141.
go back to reference Lee JS. A review of deep-learning-based approaches for attenuation correction in positron emission tomography. IEEE Trans Radiat Plasma Med Sci. 2021;5:160–84.CrossRef Lee JS. A review of deep-learning-based approaches for attenuation correction in positron emission tomography. IEEE Trans Radiat Plasma Med Sci. 2021;5:160–84.CrossRef
142.
go back to reference Kim JH, Lee JS, Kang KW, Lee HY, Han SW, Kim TY, et al. Whole-body distribution and radiation dosimetry of (68)Ga-NOTA-RGD, a positron emission tomography agent for angiogenesis imaging. Cancer Biother Radiopharm. 2012;27:65–71.PubMed Kim JH, Lee JS, Kang KW, Lee HY, Han SW, Kim TY, et al. Whole-body distribution and radiation dosimetry of (68)Ga-NOTA-RGD, a positron emission tomography agent for angiogenesis imaging. Cancer Biother Radiopharm. 2012;27:65–71.PubMed
143.
go back to reference Choi JY, Lyoo CH, Kim JS, Kim KM, Lee M, Ryu YH. Biodistribution and radiation dosimetry of [(18)F]Mefway in humans. Mol Imaging Biol. 2016;18:803–6.PubMedCrossRef Choi JY, Lyoo CH, Kim JS, Kim KM, Lee M, Ryu YH. Biodistribution and radiation dosimetry of [(18)F]Mefway in humans. Mol Imaging Biol. 2016;18:803–6.PubMedCrossRef
144.
go back to reference Choi JY, Lyoo CH, Lee JH, Cho H, Kim KM, Kim JS, et al. Human radiation dosimetry of [(18)F]AV-1451(T807) to detect tau pathology. Mol Imaging Biol. 2016;18:479–82.PubMedCrossRef Choi JY, Lyoo CH, Lee JH, Cho H, Kim KM, Kim JS, et al. Human radiation dosimetry of [(18)F]AV-1451(T807) to detect tau pathology. Mol Imaging Biol. 2016;18:479–82.PubMedCrossRef
145.
146.
go back to reference Gupta A, Lee MS, Kim JH, Park S, Park HS, Kim SE, et al. Preclinical voxel-based dosimetry through GATE Monte Carlo simulation using PET/CT imaging of mice. Phys Med Biol. 2019;64:095007 Gupta A, Lee MS, Kim JH, Park S, Park HS, Kim SE, et al. Preclinical voxel-based dosimetry through GATE Monte Carlo simulation using PET/CT imaging of mice. Phys Med Biol. 2019;64:095007
147.
go back to reference Gupta A, Shin JH, Lee MS, Park JY, Kim K, Kim JH, et al. Voxel-based dosimetry of iron oxide nanoparticle-conjugated (177)Lu-labeled folic acid using SPECT/CT imaging of mice. Mol Pharm. 2019;16:1498–506.PubMedCrossRef Gupta A, Shin JH, Lee MS, Park JY, Kim K, Kim JH, et al. Voxel-based dosimetry of iron oxide nanoparticle-conjugated (177)Lu-labeled folic acid using SPECT/CT imaging of mice. Mol Pharm. 2019;16:1498–506.PubMedCrossRef
148.
go back to reference Lee MS, Kim JH, Paeng JC, Kang KW, Jeong JM, Lee DS, et al. Whole-body voxel-based personalized dosimetry: the multiple voxel S-value approach for heterogeneous media with nonuniform activity distributions. J Nucl Med. 2018;59:1133–9.PubMedCrossRef Lee MS, Kim JH, Paeng JC, Kang KW, Jeong JM, Lee DS, et al. Whole-body voxel-based personalized dosimetry: the multiple voxel S-value approach for heterogeneous media with nonuniform activity distributions. J Nucl Med. 2018;59:1133–9.PubMedCrossRef
149.
go back to reference Song YS, Kim JH, Lee BC, Jung JH, Park HS, Kim SE. Biodistribution and internal radiation dosimetry of (99m)Tc-IDA-D-[c(RGDfK)](2) (BIK-505), a novel SPECT radiotracer for the imaging of integrin α(v)β(3) expression. Cancer Biother Radiopharm. 2018;33:396–402.PubMedPubMedCentral Song YS, Kim JH, Lee BC, Jung JH, Park HS, Kim SE. Biodistribution and internal radiation dosimetry of (99m)Tc-IDA-D-[c(RGDfK)](2) (BIK-505), a novel SPECT radiotracer for the imaging of integrin α(v)β(3) expression. Cancer Biother Radiopharm. 2018;33:396–402.PubMedPubMedCentral
150.
go back to reference Lee MS, Hwang D, Kim JH, Lee JS. Deep-dose: a voxel dose estimation method using deep convolutional neural network for personalized internal dosimetry. Sci Rep. 2019;9:10308.PubMedPubMedCentralCrossRef Lee MS, Hwang D, Kim JH, Lee JS. Deep-dose: a voxel dose estimation method using deep convolutional neural network for personalized internal dosimetry. Sci Rep. 2019;9:10308.PubMedPubMedCentralCrossRef
151.
go back to reference Lee N, Oh I, Chae SY, Jin S, Oh SJ, Lee SJ, et al. Radiation dosimetry of [(18)F]GP1 for imaging activated glycoprotein IIb/IIIa receptors with positron emission tomography in patients with acute thromboembolism. Nucl Med Biol. 2019;72–73:45–8.PubMedCrossRef Lee N, Oh I, Chae SY, Jin S, Oh SJ, Lee SJ, et al. Radiation dosimetry of [(18)F]GP1 for imaging activated glycoprotein IIb/IIIa receptors with positron emission tomography in patients with acute thromboembolism. Nucl Med Biol. 2019;72–73:45–8.PubMedCrossRef
152.
go back to reference Lee I, Lim I, Byun BH, Kim BI, Choi CW, Woo SK, et al. A microdose clinical trial to evaluate [(18)F]Florastamin as a positron emission tomography imaging agent in patients with prostate cancer. Eur J Nucl Med Mol Imaging. 2021;48:95–102.PubMedCrossRef Lee I, Lim I, Byun BH, Kim BI, Choi CW, Woo SK, et al. A microdose clinical trial to evaluate [(18)F]Florastamin as a positron emission tomography imaging agent in patients with prostate cancer. Eur J Nucl Med Mol Imaging. 2021;48:95–102.PubMedCrossRef
153.
go back to reference Woo SK, Jang SJ, Seo MJ, Park JH, Kim BS, Kim EJ, et al. Development of (64)Cu-NOTA-trastuzumab for HER2 targeting: a radiopharmaceutical with improved pharmacokinetics for human studies. J Nucl Med. 2019;60:26–33.PubMedCrossRef Woo SK, Jang SJ, Seo MJ, Park JH, Kim BS, Kim EJ, et al. Development of (64)Cu-NOTA-trastuzumab for HER2 targeting: a radiopharmaceutical with improved pharmacokinetics for human studies. J Nucl Med. 2019;60:26–33.PubMedCrossRef
154.
155.
go back to reference Kang SK, Seo S, Shin SA, Byun MS, Lee DY, Kim YK, et al. Adaptive template generation for amyloid PET using a deep learning approach. Hum Brain Mapp. 2018;39:3769–78.PubMedPubMedCentralCrossRef Kang SK, Seo S, Shin SA, Byun MS, Lee DY, Kim YK, et al. Adaptive template generation for amyloid PET using a deep learning approach. Hum Brain Mapp. 2018;39:3769–78.PubMedPubMedCentralCrossRef
156.
go back to reference Park J, Bae S, Seo S, Park S, Bang JI, Han JH, et al. Measurement of glomerular filtration rate using quantitative SPECT/CT and deep-learning-based kidney segmentation. Sci Rep. 2019;9:4223.PubMedPubMedCentralCrossRef Park J, Bae S, Seo S, Park S, Bang JI, Han JH, et al. Measurement of glomerular filtration rate using quantitative SPECT/CT and deep-learning-based kidney segmentation. Sci Rep. 2019;9:4223.PubMedPubMedCentralCrossRef
157.
158.
go back to reference Lee S, Jung JH, Kim D, Lim HK, Park MA, Kim G, et al. PET/CT for brain amyloid: a feasibility study for scan time reduction by deep learning. Clin Nucl Med. 2021;46:e133–40.PubMedCrossRef Lee S, Jung JH, Kim D, Lim HK, Park MA, Kim G, et al. PET/CT for brain amyloid: a feasibility study for scan time reduction by deep learning. Clin Nucl Med. 2021;46:e133–40.PubMedCrossRef
159.
go back to reference Choi JH, Kim HA, Kim W, Lim I, Lee I, Byun BH, et al. Early prediction of neoadjuvant chemotherapy response for advanced breast cancer using PET/MRI image deep learning. Sci Rep. 2020;10:21149.PubMedPubMedCentralCrossRef Choi JH, Kim HA, Kim W, Lim I, Lee I, Byun BH, et al. Early prediction of neoadjuvant chemotherapy response for advanced breast cancer using PET/MRI image deep learning. Sci Rep. 2020;10:21149.PubMedPubMedCentralCrossRef
160.
go back to reference Jeong YJ, Park HS, Jeong JE, Yoon HJ, Jeon K, Cho K, et al. Restoration of amyloid PET images obtained with short-time data using a generative adversarial networks framework. Sci Rep. 2021;11:4825.PubMedPubMedCentralCrossRef Jeong YJ, Park HS, Jeong JE, Yoon HJ, Jeon K, Cho K, et al. Restoration of amyloid PET images obtained with short-time data using a generative adversarial networks framework. Sci Rep. 2021;11:4825.PubMedPubMedCentralCrossRef
161.
go back to reference Yie SY, Kang SK, Hwang D, Lee JS. Self-supervised PET denoising. Nucl Med Mol Imaging. 2020;54:299–304.PubMedCrossRef Yie SY, Kang SK, Hwang D, Lee JS. Self-supervised PET denoising. Nucl Med Mol Imaging. 2020;54:299–304.PubMedCrossRef
162.
go back to reference Hyun SH, Ahn MS, Koh YW, Lee SJ. A machine-learning approach using PET-based radiomics to predict the histological subtypes of lung cancer. Clin Nucl Med. 2019;44:956–60.PubMedCrossRef Hyun SH, Ahn MS, Koh YW, Lee SJ. A machine-learning approach using PET-based radiomics to predict the histological subtypes of lung cancer. Clin Nucl Med. 2019;44:956–60.PubMedCrossRef
163.
go back to reference Ryoo HG, Choi H, Lee DS. Deep learning-based interpretation of basal/acetazolamide brain perfusion SPECT leveraging unstructured reading reports. Eur J Nucl Med Mol Imaging. 2020;47:2186–96.PubMedCrossRef Ryoo HG, Choi H, Lee DS. Deep learning-based interpretation of basal/acetazolamide brain perfusion SPECT leveraging unstructured reading reports. Eur J Nucl Med Mol Imaging. 2020;47:2186–96.PubMedCrossRef
164.
go back to reference Kim JY, Oh D, Sung K, Choi H, Paeng JC, Cheon GJ, et al. Visual interpretation of [(18)F]Florbetaben PET supported by deep learning-based estimation of amyloid burden. Eur J Nucl Med Mol Imaging. 2021;48:1116–23.PubMedCrossRef Kim JY, Oh D, Sung K, Choi H, Paeng JC, Cheon GJ, et al. Visual interpretation of [(18)F]Florbetaben PET supported by deep learning-based estimation of amyloid burden. Eur J Nucl Med Mol Imaging. 2021;48:1116–23.PubMedCrossRef
165.
go back to reference Choi H, Kim YK, Yoon EJ, Lee JY, Lee DS. Cognitive signature of brain FDG PET based on deep learning: domain transfer from Alzheimer’s disease to Parkinson’s disease. Eur J Nucl Med Mol Imaging. 2020;47:403–12.PubMedCrossRef Choi H, Kim YK, Yoon EJ, Lee JY, Lee DS. Cognitive signature of brain FDG PET based on deep learning: domain transfer from Alzheimer’s disease to Parkinson’s disease. Eur J Nucl Med Mol Imaging. 2020;47:403–12.PubMedCrossRef
166.
go back to reference Kang SK, Choi H, Lee JS. Translating amyloid PET of different radiotracers by a deep generative model for interchangeability. Neuroimage. 2021;232:117890 Kang SK, Choi H, Lee JS. Translating amyloid PET of different radiotracers by a deep generative model for interchangeability. Neuroimage. 2021;232:117890
167.
168.
go back to reference Choi H, Jin KH. Predicting cognitive decline with deep learning of brain metabolism and amyloid imaging. Behav Brain Res. 2018;344:103–9.PubMedCrossRef Choi H, Jin KH. Predicting cognitive decline with deep learning of brain metabolism and amyloid imaging. Behav Brain Res. 2018;344:103–9.PubMedCrossRef
169.
go back to reference Choi H, Ha S, Im HJ, Paek SH, Lee DS. Refining diagnosis of Parkinson’s disease with deep learning-based interpretation of dopamine transporter imaging. NeuroImage Clin. 2017;16:586–94.PubMedPubMedCentralCrossRef Choi H, Ha S, Im HJ, Paek SH, Lee DS. Refining diagnosis of Parkinson’s disease with deep learning-based interpretation of dopamine transporter imaging. NeuroImage Clin. 2017;16:586–94.PubMedPubMedCentralCrossRef
170.
go back to reference Lee S, Kim J, Kang H, Kang D-Y, Park J. Genetic algorithm based deep learning neural network structure and hyperparameter optimization. Appl Sci. 2021;11:744.CrossRef Lee S, Kim J, Kang H, Kang D-Y, Park J. Genetic algorithm based deep learning neural network structure and hyperparameter optimization. Appl Sci. 2021;11:744.CrossRef
Metadata
Title
A Brief History of Nuclear Medicine Physics, Instrumentation, and Data Sciences in Korea
Authors
Jae Sung Lee
Kyeong Min Kim
Yong Choi
Hee-Joung Kim
Publication date
01-12-2021
Publisher
Springer Singapore
Published in
Nuclear Medicine and Molecular Imaging / Issue 6/2021
Print ISSN: 1869-3474
Electronic ISSN: 1869-3482
DOI
https://doi.org/10.1007/s13139-021-00721-7

Other articles of this Issue 6/2021

Nuclear Medicine and Molecular Imaging 6/2021 Go to the issue