Skip to main content
Top
Published in: Cardiovascular Intervention and Therapeutics 2/2020

01-04-2020 | Original Article

Guide catheter extension lock enables the strongest backup force during the antegrade approach in percutaneous coronary intervention

Authors: Satoshi Kameda, Atsunori Okamura, Yasushi Sakata, Kenshi Fujii

Published in: Cardiovascular Intervention and Therapeutics | Issue 2/2020

Login to get access

Abstract

Sufficient guide catheter backup is crucial for successful percutaneous coronary intervention (PCI). We have developed a new technique for locking a small child catheter to the vessel wall by balloon dilatation outside the child catheter at the proximal site of the main branch. We call this the “guide catheter extension lock” (“Kiwami® lock”, Kiwami® child catheter, Terumo Corp. Tokyo, Japan). The guide catheter extension lock backup force was evaluated in an experimental model, and we report a case of chronic total occlusion treated with PCI using this technique. The guide catheter backup force was measured using an artificial cardiac vessel model with a right coronary artery and side branch. We evaluated the backup forces of the guide catheter extension lock and other techniques using an 8Fr Judkins right guide catheter (child catheter: 45.0 ± 4.6 g force [gf]; a 7Fr delivery catheter (Guide-Liner®, Vascular Solutions, Minneapolis MN, USA): 67.4 ± 14.4 gf; an anchoring balloon technique at the side branch: 98.3 ± 11.9 gf; and the guide catheter extension lock: 112.1 ± 13.0 gf). The guide catheter extension lock technique provided the strongest backup force. Our clinical experience shows that this technique is effective during PCI.
Literature
1.
go back to reference Satoshi T, Koki S, Kazuya S, Nobuhiro O, Shingo M, Kenji Y, et al. In vitro and human studies of a 4F double-coaxial technique (“mother-child” configuration) to facilitate stent implantation in resistant coronary vessels. Circ Cardiovasc Interv. 2011;4:155–61.CrossRef Satoshi T, Koki S, Kazuya S, Nobuhiro O, Shingo M, Kenji Y, et al. In vitro and human studies of a 4F double-coaxial technique (“mother-child” configuration) to facilitate stent implantation in resistant coronary vessels. Circ Cardiovasc Interv. 2011;4:155–61.CrossRef
2.
go back to reference de Man FHAF, Tandjung K, Hartmann M, van Houwelingen KG, Stoel MG, Louwerenburg HW, et al. Usefulness and safety of the GuideLiner catheter to enhance intubation and support of guide catheters: insights from the Twente GuideLiner registry. EuroIntervention. 2012;8:336–44.CrossRef de Man FHAF, Tandjung K, Hartmann M, van Houwelingen KG, Stoel MG, Louwerenburg HW, et al. Usefulness and safety of the GuideLiner catheter to enhance intubation and support of guide catheters: insights from the Twente GuideLiner registry. EuroIntervention. 2012;8:336–44.CrossRef
3.
go back to reference Takahashi A, Taniguchi N, Yamada T, Mizuguchi Y, Hata T, Nakajima S. The novel 4.5F Cokatte catheter for stent delivery facilitation in complex coronary artery lesions. Cardiovasc Revasc Med. 2014;15:346–9.CrossRef Takahashi A, Taniguchi N, Yamada T, Mizuguchi Y, Hata T, Nakajima S. The novel 4.5F Cokatte catheter for stent delivery facilitation in complex coronary artery lesions. Cardiovasc Revasc Med. 2014;15:346–9.CrossRef
4.
go back to reference Shinya F, Hideo T, Eisho K, Kunihiko K, Tatsuhiko H, Masaharu O, et al. New technique for superior guiding catheter support during advancement of balloon in coronary angioplasty: the anchor technique. Catheter Cardiovasc Interv. 2003;59:482–8.CrossRef Shinya F, Hideo T, Eisho K, Kunihiko K, Tatsuhiko H, Masaharu O, et al. New technique for superior guiding catheter support during advancement of balloon in coronary angioplasty: the anchor technique. Catheter Cardiovasc Interv. 2003;59:482–8.CrossRef
5.
go back to reference Mitsugu H, Shigeru S, Hatutatsu M. Anchoring technique to improve guiding catheter support in coronary angioplasty of chronic total occlusions. Catheter Cardiovasc Interv. 2006;67:366–71.CrossRef Mitsugu H, Shigeru S, Hatutatsu M. Anchoring technique to improve guiding catheter support in coronary angioplasty of chronic total occlusions. Catheter Cardiovasc Interv. 2006;67:366–71.CrossRef
6.
go back to reference Mahmood A, Banerjee S, Brilakis ES. Applications of the distal anchoring technique in coronary and peripheral interventions. J Invasive Cardiol. 2011;23:289–92. Mahmood A, Banerjee S, Brilakis ES. Applications of the distal anchoring technique in coronary and peripheral interventions. J Invasive Cardiol. 2011;23:289–92.
7.
go back to reference Ikari Y, Nagaoka M, Kim J, Morino Y, Tanabe T. The physics of guiding catheter for the left coronary artery in transfemoral and transradial interventions. J Invasive Cardiol. 2005;17:636–41.PubMed Ikari Y, Nagaoka M, Kim J, Morino Y, Tanabe T. The physics of guiding catheter for the left coronary artery in transfemoral and transradial interventions. J Invasive Cardiol. 2005;17:636–41.PubMed
8.
go back to reference Hiwatashi A, Iwabuchi M, Yokoi H, Tayama S, Sakamoto T, Noda K, et al. PCI using a 4-Fr child catheter in a mother guide catheter: Kyushu KIWAMI ST Registry. Catheter Cardiovasc Interv. 2010;76:919–23.CrossRef Hiwatashi A, Iwabuchi M, Yokoi H, Tayama S, Sakamoto T, Noda K, et al. PCI using a 4-Fr child catheter in a mother guide catheter: Kyushu KIWAMI ST Registry. Catheter Cardiovasc Interv. 2010;76:919–23.CrossRef
9.
go back to reference Takahashi S, Saito S, Tanaka S, Miyashita Y, Shiono T, Arai F, et al. New method to increase a backup support of a 6 French guiding coronary catheter. Catheter Cardiovasc Interv. 2004;63:452–6.CrossRef Takahashi S, Saito S, Tanaka S, Miyashita Y, Shiono T, Arai F, et al. New method to increase a backup support of a 6 French guiding coronary catheter. Catheter Cardiovasc Interv. 2004;63:452–6.CrossRef
10.
go back to reference Okamura A, Iwakura K, Nagai H, Kawamura K, Yamasaki T, Fujii K. Chronic total occlusion treated with coronary intervention by three-dimensional guidewire manipulation: an experimental study and clinical experience. Cardiovasc Interv Ther. 2016;31:238–44.CrossRef Okamura A, Iwakura K, Nagai H, Kawamura K, Yamasaki T, Fujii K. Chronic total occlusion treated with coronary intervention by three-dimensional guidewire manipulation: an experimental study and clinical experience. Cardiovasc Interv Ther. 2016;31:238–44.CrossRef
11.
go back to reference Reo N, Takashi Y, Keisuke O, Nobuyuki M, Takayoshi S, Noriyuki K. A successful treatment for a lesion of chronic total occlusion using guiding catheter lock technique. Cardiovasc Interv Ther. 2018;33:402–3.CrossRef Reo N, Takashi Y, Keisuke O, Nobuyuki M, Takayoshi S, Noriyuki K. A successful treatment for a lesion of chronic total occlusion using guiding catheter lock technique. Cardiovasc Interv Ther. 2018;33:402–3.CrossRef
12.
go back to reference Takunori T, Kenichi S, Yousuke T, Kei Y, Hiroshi W, Shin-ichi M, et al. Comparison of the device performance between the conventional guide extension catheter and the soft guide extension catheter. Cardiovasc Revascularization Med. 2018;20:113–9 (pii: S1553838918302410) (Accessed 1 June 2018). Takunori T, Kenichi S, Yousuke T, Kei Y, Hiroshi W, Shin-ichi M, et al. Comparison of the device performance between the conventional guide extension catheter and the soft guide extension catheter. Cardiovasc Revascularization Med. 2018;20:113–9 (pii: S1553838918302410) (Accessed 1 June 2018).
Metadata
Title
Guide catheter extension lock enables the strongest backup force during the antegrade approach in percutaneous coronary intervention
Authors
Satoshi Kameda
Atsunori Okamura
Yasushi Sakata
Kenshi Fujii
Publication date
01-04-2020
Publisher
Springer Japan
Published in
Cardiovascular Intervention and Therapeutics / Issue 2/2020
Print ISSN: 1868-4300
Electronic ISSN: 1868-4297
DOI
https://doi.org/10.1007/s12928-019-00596-8

Other articles of this Issue 2/2020

Cardiovascular Intervention and Therapeutics 2/2020 Go to the issue