Skip to main content
Top
Published in: Netherlands Heart Journal 2/2018

Open Access 01-02-2018 | Original Article

Effects of hyperaemia on left ventricular longitudinal strain in patients with suspected coronary artery disease

A first-pass stress perfusion cardiovascular magnetic resonance imaging study

Authors: P. Garg, R. Aziz, T. Al Musa, D. P. Ripley, P. Haaf, J. R. J. Foley, P. P. Swoboda, G. J. Fent, L. E. Dobson, J. P. Greenwood, S. Plein

Published in: Netherlands Heart Journal | Issue 2/2018

Login to get access

Abstract

Aims

Myocardial perfusion imaging during hyperaemic stress is commonly used to detect coronary artery disease. The aim of this study was to investigate the relationship between left ventricular global longitudinal strain (GLS), strain rate (GLSR), myocardial early (E’) and late diastolic velocities (A’) with adenosine stress first-pass perfusion cardiovascular magnetic resonance (CMR) imaging.

Methods and results

44 patients met the inclusion criteria and underwent CMR imaging. The CMR imaging protocol included: rest/stress horizontal long-axis (HLA) cine, rest/stress first-pass adenosine perfusion and late gadolinium enhancement imaging. Rest and stress HLA cine CMR images were analysed using feature-tracking software for the assessment of myocardial deformation. The presence of perfusion defects was scored on a binomial scale. In patients with hyperaemia-induced perfusion defects, rest global longitudinal strain GLS (−16.9 ± 3.7 vs. −19.6 ± 3.4; p-value = 0.02), E’ (−86 ± 22 vs. −109 ± 38; p-value = 0.02), GLSR (69 ± 31 vs. 93 ± 38; p-value = 0.01) and stress GLS (−16.5 ± 4 vs. −21 ± 3.1; p < 0.001) were significantly reduced when compared with patients with no perfusion defects. Stress GLS was the strongest independent predictor of perfusion defects (odds ratio 1.43 95% confidence interval 1.14–1.78, p-value <0.001). A threshold of −19.8% for stress GLS demonstrated 78% sensitivity and 73% specificity for the presence of hyperaemia-induced perfusion defects.

Conclusions

At peak myocardial hyperaemic stress, GLS is reduced in the presence of a perfusion defect in patients with suspected coronary artery disease. This reduction is most likely caused by reduced endocardial blood flow at maximal hyperaemia because of transmural redistribution of blood flow in the presence of significant coronary stenosis.
Appendix
Available only for authorised users
Literature
2.
go back to reference Pan J, Huang S, Lu Z, et al. Comparison of myocardial transmural perfusion gradient by magnetic resonance imaging to fractional flow reserve in patients with suspected coronary artery disease. Am J Cardiol. 2015;115:1333–40.CrossRefPubMed Pan J, Huang S, Lu Z, et al. Comparison of myocardial transmural perfusion gradient by magnetic resonance imaging to fractional flow reserve in patients with suspected coronary artery disease. Am J Cardiol. 2015;115:1333–40.CrossRefPubMed
4.
go back to reference Algranati D, Kassab GS, Lanir Y. Why is the subendocardium more vulnerable to ischemia? A new paradigm. Am J Physiol Heart Circ Physiol. 2011;300:H1090–H100.CrossRefPubMed Algranati D, Kassab GS, Lanir Y. Why is the subendocardium more vulnerable to ischemia? A new paradigm. Am J Physiol Heart Circ Physiol. 2011;300:H1090–H100.CrossRefPubMed
5.
go back to reference Chiribiri A, Hautvast GLTF, Lockie T, et al. Assessment of coronary artery Stenosis severity and location: quantitative analysis of transmural perfusion gradients by high-resolution MRI versus FFR. JACC Cardiovasc Imaging. 2013;6:600–9.CrossRefPubMed Chiribiri A, Hautvast GLTF, Lockie T, et al. Assessment of coronary artery Stenosis severity and location: quantitative analysis of transmural perfusion gradients by high-resolution MRI versus FFR. JACC Cardiovasc Imaging. 2013;6:600–9.CrossRefPubMed
6.
go back to reference Panaich S, Briasoulis A, Cardozo S, Afonso L. Incremental value of two dimensional speckle tracking echocardiography in the functional assessment and characterization of subclinical left ventricular dysfunction. Curr Cardiol Rev. 2016;13(1):32–40.CrossRef Panaich S, Briasoulis A, Cardozo S, Afonso L. Incremental value of two dimensional speckle tracking echocardiography in the functional assessment and characterization of subclinical left ventricular dysfunction. Curr Cardiol Rev. 2016;13(1):32–40.CrossRef
7.
go back to reference Swoboda P, McDiarmid AK, Erhayiem B, et al. The association between fibrosis and contractile dysfunction in hypertrophic cardiomyopathy assessed by cardiovascular magnetic resonance. Eur Heart J Cardiovasc Imaging. 2016;17(Suppl 1):i1–i80. https://doi.org/10.1093/ehjci/jew093. Swoboda P, McDiarmid AK, Erhayiem B, et al. The association between fibrosis and contractile dysfunction in hypertrophic cardiomyopathy assessed by cardiovascular magnetic resonance. Eur Heart J Cardiovasc Imaging. 2016;17(Suppl 1):i1–i80. https://​doi.​org/​10.​1093/​ehjci/​jew093.
9.
go back to reference Schulz-Menger J, Bluemke DA, Bremerich J, et al. Standardized image interpretation and post processing in cardiovascular magnetic resonance: Society for Cardiovascular Magnetic Resonance (SCMR) board of trustees task force on standardized post processing. J Cardiovasc Magn Reson. 2013;15:35.CrossRefPubMedPubMedCentral Schulz-Menger J, Bluemke DA, Bremerich J, et al. Standardized image interpretation and post processing in cardiovascular magnetic resonance: Society for Cardiovascular Magnetic Resonance (SCMR) board of trustees task force on standardized post processing. J Cardiovasc Magn Reson. 2013;15:35.CrossRefPubMedPubMedCentral
10.
go back to reference Cerqueira MD, Weissman NJ, Dilsizian V, et al. Standardized myocardial segmentation and nomenclature for tomographic imaging of the heart. A statement for healthcare professionals from the Cardiac Imaging Committee of the Council on Clinical Cardiology of the American Heart Association. Circulation. 2002;105:539–42.CrossRefPubMed Cerqueira MD, Weissman NJ, Dilsizian V, et al. Standardized myocardial segmentation and nomenclature for tomographic imaging of the heart. A statement for healthcare professionals from the Cardiac Imaging Committee of the Council on Clinical Cardiology of the American Heart Association. Circulation. 2002;105:539–42.CrossRefPubMed
12.
go back to reference Plein S, Kozerke S, Suerder D, et al. High spatial resolution myocardial perfusion cardiac magnetic resonance for the detection of coronary artery disease. Eur Heart J. 2008;29:2148–55.CrossRefPubMedPubMedCentral Plein S, Kozerke S, Suerder D, et al. High spatial resolution myocardial perfusion cardiac magnetic resonance for the detection of coronary artery disease. Eur Heart J. 2008;29:2148–55.CrossRefPubMedPubMedCentral
13.
go back to reference Reimer KA, Jennings RB. The ‘wavefront phenomenon’ of myocardial ischemic cell death. II. Transmural progression of necrosis within the framework of ischemic bed size (myocardium at risk) and collateral flow. Lab Invest. 1979;40:633–44.PubMed Reimer KA, Jennings RB. The ‘wavefront phenomenon’ of myocardial ischemic cell death. II. Transmural progression of necrosis within the framework of ischemic bed size (myocardium at risk) and collateral flow. Lab Invest. 1979;40:633–44.PubMed
14.
go back to reference Greenbaum RA, Ho SY, Gibson DG, Becker AE, Anderson RH. Left ventricular fibre architecture in man. Heart. 1981;45:248–63.CrossRef Greenbaum RA, Ho SY, Gibson DG, Becker AE, Anderson RH. Left ventricular fibre architecture in man. Heart. 1981;45:248–63.CrossRef
15.
go back to reference Birkeland S, Westby J, Hessevik I, et al. Compensatory subendocardial hyperkinesis in the cat is abolished during coronary insufficiency outside an acutely ischaemic region. Cardiovasc Res. 1992;26:285–91.CrossRefPubMed Birkeland S, Westby J, Hessevik I, et al. Compensatory subendocardial hyperkinesis in the cat is abolished during coronary insufficiency outside an acutely ischaemic region. Cardiovasc Res. 1992;26:285–91.CrossRefPubMed
16.
go back to reference Liang H‑Y, Cauduro S, Pellikka P, et al. Usefulness of two-dimensional speckle strain for evaluation of left ventricular diastolic deformation in patients with coronary artery disease. Am J Cardiol. 2006;98:1581–6.CrossRefPubMed Liang H‑Y, Cauduro S, Pellikka P, et al. Usefulness of two-dimensional speckle strain for evaluation of left ventricular diastolic deformation in patients with coronary artery disease. Am J Cardiol. 2006;98:1581–6.CrossRefPubMed
17.
go back to reference Reant P, Labrousse L, Lafitte S, et al. Experimental validation of circumferential, longitudinal, and radial 2‑dimensional strain during dobutamine stress echocardiography in ischemic conditions. J Am Coll Cardiol. 2008;51:149–57.CrossRefPubMed Reant P, Labrousse L, Lafitte S, et al. Experimental validation of circumferential, longitudinal, and radial 2‑dimensional strain during dobutamine stress echocardiography in ischemic conditions. J Am Coll Cardiol. 2008;51:149–57.CrossRefPubMed
18.
go back to reference Ng ACT, Sitges M, Pham PN, et al. Incremental value of 2‑dimensional speckle tracking strain imaging to wall motion analysis for detection of coronary artery disease in patients undergoing dobutamine stress echocardiography. Am Heart J. 2009;158:836–44.CrossRefPubMed Ng ACT, Sitges M, Pham PN, et al. Incremental value of 2‑dimensional speckle tracking strain imaging to wall motion analysis for detection of coronary artery disease in patients undergoing dobutamine stress echocardiography. Am Heart J. 2009;158:836–44.CrossRefPubMed
19.
go back to reference Chow BJW, Abraham A, Wells GA, et al. Diagnostic accuracy and impact of computed tomographic coronary angiography on utilization of invasive coronary angiography. Circ Cardiovasc Imaging. 2009;2:16–23.CrossRefPubMed Chow BJW, Abraham A, Wells GA, et al. Diagnostic accuracy and impact of computed tomographic coronary angiography on utilization of invasive coronary angiography. Circ Cardiovasc Imaging. 2009;2:16–23.CrossRefPubMed
20.
go back to reference Greenwood JP, Maredia N, Younger JF, et al. Cardiovascular magnetic resonance and single-photon emission computed tomography for diagnosis of coronary heart disease (CE-MARC): a prospective trial. Lancet. 2012;379:453–60.CrossRefPubMedPubMedCentral Greenwood JP, Maredia N, Younger JF, et al. Cardiovascular magnetic resonance and single-photon emission computed tomography for diagnosis of coronary heart disease (CE-MARC): a prospective trial. Lancet. 2012;379:453–60.CrossRefPubMedPubMedCentral
21.
go back to reference Seward JB, Casaclang-verzosa G. Infiltrative cardiovascular diseases: cardiomyopathies that look alike. J Am Coll Cardiol. 2010;55:1769–79.CrossRefPubMed Seward JB, Casaclang-verzosa G. Infiltrative cardiovascular diseases: cardiomyopathies that look alike. J Am Coll Cardiol. 2010;55:1769–79.CrossRefPubMed
22.
go back to reference Afonso L, Kondur A, Simegn M, et al. Two-dimensional strain profiles in patients with physiological and pathological hypertrophy and preserved left ventricular systolic function : a comparative analyses. BMJ. 2012;2:1–9. Afonso L, Kondur A, Simegn M, et al. Two-dimensional strain profiles in patients with physiological and pathological hypertrophy and preserved left ventricular systolic function : a comparative analyses. BMJ. 2012;2:1–9.
23.
go back to reference Kul S, Ozcelik HK, Uyarel H, et al. Diagnostic value of strain echocardiography, galectin-3, and tenascin-C levels for the identification of patients with pulmonary and cardiac sarcoidosis. Lung. 2014;192:533–42.CrossRefPubMed Kul S, Ozcelik HK, Uyarel H, et al. Diagnostic value of strain echocardiography, galectin-3, and tenascin-C levels for the identification of patients with pulmonary and cardiac sarcoidosis. Lung. 2014;192:533–42.CrossRefPubMed
Metadata
Title
Effects of hyperaemia on left ventricular longitudinal strain in patients with suspected coronary artery disease
A first-pass stress perfusion cardiovascular magnetic resonance imaging study
Authors
P. Garg
R. Aziz
T. Al Musa
D. P. Ripley
P. Haaf
J. R. J. Foley
P. P. Swoboda
G. J. Fent
L. E. Dobson
J. P. Greenwood
S. Plein
Publication date
01-02-2018
Publisher
Bohn Stafleu van Loghum
Published in
Netherlands Heart Journal / Issue 2/2018
Print ISSN: 1568-5888
Electronic ISSN: 1876-6250
DOI
https://doi.org/10.1007/s12471-017-1071-3

Other articles of this Issue 2/2018

Netherlands Heart Journal 2/2018 Go to the issue

Rhythm Puzzle - Question

An irregular atrial tachycardia

Rhythm Puzzle - Answer

An irregular atrial tachycardia