Published in: Journal of Nuclear Cardiology 6/2019

01-12-2019 | Positron Emission Tomography | Editorial

Quantification of PET Studies

Author: Adriaan A. Lammertsma, PhD

Published in: Journal of Nuclear Cardiology | Issue 6/2019

Login to get access

Excerpt

Positron emission tomography (PET) is a unique molecular imaging modality, which allows for non-invasive in vivo assessments of regional tissue function in man.1 It represents the most selective and sensitive (pico- to nano-molar range) method for measuring molecular pathways and interactions in vivo.2 A multitude of physiological, biochemical, and pharmacological parameters can be measured, including blood flow (perfusion), blood volume (vascularity), oxygen utilization, glucose metabolism, pre- and post-synaptic receptor density and affinity, neurotransmitter release, enzyme activity, drug delivery and uptake, gene expression, etc. Within cardiology the method has mainly been used for assessing myocardial blood flow (MBF) and glucose metabolism (MMRglu). In fact, the so-called MBF/MMRglu match/mismatch approach3 probably was the first diagnostic application of PET and for many years has been the gold standard for assessing myocardial viability. Apart from its use in diagnostic imaging, PET has the capacity to provide new information on human disease, for example by using novel radiotracers. In recent years, PET plays an increasing role in the objective assessment of both progression of disease and therapeutic efficacy.4 At present, the latter application has found its way in the development of new drugs, but at the same time there is an enormous potential to use PET as a guiding tool in precision medicine. …
Literature
1.
go back to reference Phelps ME. PET: molecular imaging and its biological applications. Berlin: Springer; 2004.CrossRef Phelps ME. PET: molecular imaging and its biological applications. Berlin: Springer; 2004.CrossRef
2.
go back to reference Jones T. The role of positron emission tomography within the spectrum of medical imaging. Eur J Nucl Med. 1996;23:207–11.CrossRef Jones T. The role of positron emission tomography within the spectrum of medical imaging. Eur J Nucl Med. 1996;23:207–11.CrossRef
3.
go back to reference Tillisch J, Brunken R, Marshall R, Schwaiger M, Mandelkern M, Phelps M, et al. Reversibility of cardiac wall-motion abnormalities predicted by positron tomography. N Engl J Med. 1986;314:884–8.CrossRef Tillisch J, Brunken R, Marshall R, Schwaiger M, Mandelkern M, Phelps M, et al. Reversibility of cardiac wall-motion abnormalities predicted by positron tomography. N Engl J Med. 1986;314:884–8.CrossRef
4.
go back to reference Yoshinaga K, Chow BJ, deKemp RA, Thorn S, Ruddy TD, Davies RA, et al. Application of cardiac molecular imaging using positron emission tomography in evaluation of drug and therapeutics for cardiovascular disorders. Curr Pharm Des. 2005;11:903–32.CrossRef Yoshinaga K, Chow BJ, deKemp RA, Thorn S, Ruddy TD, Davies RA, et al. Application of cardiac molecular imaging using positron emission tomography in evaluation of drug and therapeutics for cardiovascular disorders. Curr Pharm Des. 2005;11:903–32.CrossRef
5.
go back to reference Harms HJ, Huisman MC, Knaapen P, Lammertsma AA, Lubberink M. Parametric imaging of myocardial blood flow and viability using [15O]H2O and PET/CT. Imaging Med. 2011;3:711–24.CrossRef Harms HJ, Huisman MC, Knaapen P, Lammertsma AA, Lubberink M. Parametric imaging of myocardial blood flow and viability using [15O]H2O and PET/CT. Imaging Med. 2011;3:711–24.CrossRef
6.
go back to reference Danad I, Raijmakers PG, Driessen RS, Leipsic J, Raju R, Naoum C, et al. Comparison of coronary CT angiography, SPECT, PET, and hybrid imaging for diagnosis of ischemic heart disease determined by fractional flow reserve. JAMA Cardiol. 2017;2:1100–7.CrossRef Danad I, Raijmakers PG, Driessen RS, Leipsic J, Raju R, Naoum C, et al. Comparison of coronary CT angiography, SPECT, PET, and hybrid imaging for diagnosis of ischemic heart disease determined by fractional flow reserve. JAMA Cardiol. 2017;2:1100–7.CrossRef
8.
go back to reference Hoffman EJ, Huang SC, Phelps ME. Quantitation in positron emission computed tomography: 1. Effect of object size. J Comput Assist Tomogr. 1979;3:299–308.CrossRef Hoffman EJ, Huang SC, Phelps ME. Quantitation in positron emission computed tomography: 1. Effect of object size. J Comput Assist Tomogr. 1979;3:299–308.CrossRef
9.
go back to reference Ter-Pogossian MM, Bergmann SR, Sobel BE. Influence of cardiac and respiratory motion on tomographic reconstructions of the heart: implications for quantitative nuclear cardiology. J Comput Assist Tomogr. 1982;6:1148–55.CrossRef Ter-Pogossian MM, Bergmann SR, Sobel BE. Influence of cardiac and respiratory motion on tomographic reconstructions of the heart: implications for quantitative nuclear cardiology. J Comput Assist Tomogr. 1982;6:1148–55.CrossRef
10.
go back to reference Lammertsma AA. Compartmental modeling in emission tomography. In: Grupen C, Buvat I, editors. Handbook of particle detection and imaging. Berlin: Springer; 2012. p. 1065–81.CrossRef Lammertsma AA. Compartmental modeling in emission tomography. In: Grupen C, Buvat I, editors. Handbook of particle detection and imaging. Berlin: Springer; 2012. p. 1065–81.CrossRef
11.
go back to reference Iida H, Kanno I, Takahashi A, Miura S, Murakami M, Takahashi K, et al. Measurement of absolute myocardial blood flow with H215O and dynamic positron-emission tomography. Strategy for quantification in relation to the partial-volume effect. Circulation. 1988;78:104–15.CrossRef Iida H, Kanno I, Takahashi A, Miura S, Murakami M, Takahashi K, et al. Measurement of absolute myocardial blood flow with H215O and dynamic positron-emission tomography. Strategy for quantification in relation to the partial-volume effect. Circulation. 1988;78:104–15.CrossRef
12.
go back to reference Patlak CS, Blasberg RG, Fenstermacher JD. Graphical evaluation of blood-to-brain transfer constants from multiple- time uptake data. J Cereb Blood Flow Metab. 1983;3:1–7.CrossRef Patlak CS, Blasberg RG, Fenstermacher JD. Graphical evaluation of blood-to-brain transfer constants from multiple- time uptake data. J Cereb Blood Flow Metab. 1983;3:1–7.CrossRef
Metadata
Title
Quantification of PET Studies
Author
Adriaan A. Lammertsma, PhD
Publication date
01-12-2019
Publisher
Springer International Publishing
Published in
Journal of Nuclear Cardiology / Issue 6/2019
Print ISSN: 1071-3581
Electronic ISSN: 1532-6551
DOI
https://doi.org/10.1007/s12350-018-01583-x

Other articles of this Issue 6/2019

Journal of Nuclear Cardiology 6/2019 Go to the issue