Skip to main content
Top
Published in: Journal of Nuclear Cardiology 2/2010

01-04-2010 | Original Article

Diagnostic and prognostic value of myocardial perfusion gated SPECT in orthotopic heart transplant recipients

Authors: Alain Manrique, MD, PhD, Mathieu Bernard, MD, Anne Hitzel, MD, Michael Bubenheim, PhD, Christophe Tron, MD, Denis Agostini, MD, PhD, Alain Cribier, Pierre Véra, MD, PhD, Jean Paul Bessou, MD, Michel Redonnet, MD

Published in: Journal of Nuclear Cardiology | Issue 2/2010

Login to get access

Abstract

Background

Cardiac allograft vasculopathy (CAV) limits long-term survival after heart transplantation. Diagnostic and prognostic value of gated single photon emission computed tomography (gated SPECT) has not been documented in this setting.

Methods and Results

We identified 110 consecutive heart transplant recipients (with transplantation >18 months) who underwent stress–rest gated SPECT and coronary angiography within 1 month, and were clinically monitored in a single heart transplantation center. Visual scoring of perfusion and wall motion images used a 16-segment model. Left ventricular function was automatically calculated. Coronary angiography was normal in 64 patients (58%) and abnormal in 46 (any CAV, 42%), of whom 19 had severe stenoses. Sensitivity and negative predictive (NPV) value were .63 and .75 for identification of any CAV, and .84 and .96 for severe CAV. Cox regression analysis showed that independent predictors of cardiac death and retransplantation were the presence of any angiographic CAV lesions (RR = 8.816, P = .043) and a stress perfusion defect >3 segments (RR = 5.607, P = .0053). A stress perfusion defect >3 segments predicted the need for late coronary revascularization >2 months (RR = 6.11, P = .0002).

Conclusions

We conclude that perfusion gated SPECT is a useful noninvasive screening test and may be proposed to help identify heart transplant recipients with a high risk of poor clinical outcome. A normal gated SPECT was associated with a low risk of cardiac hard event and might alleviate the need for coronary angiography.
Literature
1.
go back to reference Taylor DO, Edwards LB, Boucek MM, et al. Registry of the International Society for Heart and Lung Transplantation: Twenty-fourth official adult heart transplant report–2007. J Heart Lung Transplant 2007;26:769-81.CrossRefPubMed Taylor DO, Edwards LB, Boucek MM, et al. Registry of the International Society for Heart and Lung Transplantation: Twenty-fourth official adult heart transplant report–2007. J Heart Lung Transplant 2007;26:769-81.CrossRefPubMed
3.
go back to reference Johnson DE, Alderman EL, Schroeder JS, et al. Transplant coronary artery disease: Histopathologic correlations with angiographic morphology. J Am Coll Cardiol 1991;17:449-57.PubMed Johnson DE, Alderman EL, Schroeder JS, et al. Transplant coronary artery disease: Histopathologic correlations with angiographic morphology. J Am Coll Cardiol 1991;17:449-57.PubMed
4.
go back to reference St Goar FG, Pinto FJ, Alderman EL, et al. Detection of coronary atherosclerosis in young adult hearts using intravascular ultrasound. Circulation 1992;86:756-63.PubMed St Goar FG, Pinto FJ, Alderman EL, et al. Detection of coronary atherosclerosis in young adult hearts using intravascular ultrasound. Circulation 1992;86:756-63.PubMed
5.
go back to reference Redonnet M, Derumeaux G, Mouton-Schleifer D, et al. Noninvasive detection of cardiac graft vascular disease. Transplant Proc 1995;27:2530-1.PubMed Redonnet M, Derumeaux G, Mouton-Schleifer D, et al. Noninvasive detection of cardiac graft vascular disease. Transplant Proc 1995;27:2530-1.PubMed
6.
go back to reference Derumeaux G, Redonnet M, Mouton-Schleifer D, et al. Dobutamine stress echocardiography in orthotopic heart transplant recipients. J Am Coll Cardiol 1995;25:1665-72.CrossRefPubMed Derumeaux G, Redonnet M, Mouton-Schleifer D, et al. Dobutamine stress echocardiography in orthotopic heart transplant recipients. J Am Coll Cardiol 1995;25:1665-72.CrossRefPubMed
7.
go back to reference Geleijnse ML, Fioretti PM, Roelandt JR. Methodology, feasibility, safety and diagnostic accuracy of dobutamine stress echocardiography. J Am Coll Cardiol 1997;30:595-606.CrossRefPubMed Geleijnse ML, Fioretti PM, Roelandt JR. Methodology, feasibility, safety and diagnostic accuracy of dobutamine stress echocardiography. J Am Coll Cardiol 1997;30:595-606.CrossRefPubMed
8.
go back to reference Ciliberto GR, Ruffini L, Mangiavacchi M, et al. Resting echocardiography and quantitative dipyridamole technetium-99m sestamibi tomography in the identification of cardiac allograft vasculopathy and the prediction of long-term prognosis after heart transplantation. Eur Heart J 2001;22:964-71.CrossRefPubMed Ciliberto GR, Ruffini L, Mangiavacchi M, et al. Resting echocardiography and quantitative dipyridamole technetium-99m sestamibi tomography in the identification of cardiac allograft vasculopathy and the prediction of long-term prognosis after heart transplantation. Eur Heart J 2001;22:964-71.CrossRefPubMed
9.
go back to reference DePuey EG, Rozanski A. Using gated technetium-99m-sestamibi SPECT to characterize fixed myocardial defects as infarct or artifact. J Nucl Med 1995;36:952-5.PubMed DePuey EG, Rozanski A. Using gated technetium-99m-sestamibi SPECT to characterize fixed myocardial defects as infarct or artifact. J Nucl Med 1995;36:952-5.PubMed
10.
go back to reference Sharir T, Germano G, Kang X, et al. Prediction of myocardial infarction versus cardiac death by gated myocardial perfusion SPECT: Risk stratification by the amount of stress-induced ischemia and the poststress ejection fraction. J Nucl Med 2001;42:831-7.PubMed Sharir T, Germano G, Kang X, et al. Prediction of myocardial infarction versus cardiac death by gated myocardial perfusion SPECT: Risk stratification by the amount of stress-induced ischemia and the poststress ejection fraction. J Nucl Med 2001;42:831-7.PubMed
11.
go back to reference Gao SZ, Alderman EL, Schroeder JS, Silverman JF, Hunt SA. Accelerated coronary vascular disease in the heart transplant patient: Coronary arteriographic findings. J Am Coll Cardiol 1988;12:334-40.PubMed Gao SZ, Alderman EL, Schroeder JS, Silverman JF, Hunt SA. Accelerated coronary vascular disease in the heart transplant patient: Coronary arteriographic findings. J Am Coll Cardiol 1988;12:334-40.PubMed
12.
go back to reference Puskas C, Kosch M, Kerber S, et al. Progressive heterogeneity of myocardial perfusion in heart transplant recipients detected by thallium-201 myocardial SPECT. J Nucl Med 1997;38:760-5.PubMed Puskas C, Kosch M, Kerber S, et al. Progressive heterogeneity of myocardial perfusion in heart transplant recipients detected by thallium-201 myocardial SPECT. J Nucl Med 1997;38:760-5.PubMed
13.
go back to reference Smart FW, Ballantyne CM, Cocanougher B, et al. Insensitivity of noninvasive tests to detect coronary artery vasculopathy after heart transplant. Am J Cardiol 1991;67:243-7.CrossRefPubMed Smart FW, Ballantyne CM, Cocanougher B, et al. Insensitivity of noninvasive tests to detect coronary artery vasculopathy after heart transplant. Am J Cardiol 1991;67:243-7.CrossRefPubMed
14.
go back to reference Ciliberto GR, Mangiavacchi M, Banfi F, et al. Coronary artery disease after heart transplantation: Non-invasive evaluation with exercise thallium scintigraphy. Eur Heart J 1993;14:226-9.PubMed Ciliberto GR, Mangiavacchi M, Banfi F, et al. Coronary artery disease after heart transplantation: Non-invasive evaluation with exercise thallium scintigraphy. Eur Heart J 1993;14:226-9.PubMed
15.
go back to reference Rodney RA, Johnson LL, Blood DK, Barr ML. Myocardial perfusion scintigraphy in heart transplant recipients with and without allograft atherosclerosis: A comparison of thallium-201 and technetium 99m sestamibi. J Heart Lung Transplant 1994;13:173-80.PubMed Rodney RA, Johnson LL, Blood DK, Barr ML. Myocardial perfusion scintigraphy in heart transplant recipients with and without allograft atherosclerosis: A comparison of thallium-201 and technetium 99m sestamibi. J Heart Lung Transplant 1994;13:173-80.PubMed
16.
go back to reference Howarth DM, Forstrom LA, Samudrala V, et al. Evaluation of 201Tl SPET myocardial perfusion imaging in the detection of coronary artery disease after orthotopic heart transplantation. Nucl Med Commun 1996;17:105-13.PubMedCrossRef Howarth DM, Forstrom LA, Samudrala V, et al. Evaluation of 201Tl SPET myocardial perfusion imaging in the detection of coronary artery disease after orthotopic heart transplantation. Nucl Med Commun 1996;17:105-13.PubMedCrossRef
17.
go back to reference Elhendy A, Sozzi FB, van Domburg RT, et al. Accuracy of dobutamine tetrofosmin myocardial perfusion imaging for the noninvasive diagnosis of transplant coronary artery stenosis. J Heart Lung Transplant 2000;19:360-6.CrossRefPubMed Elhendy A, Sozzi FB, van Domburg RT, et al. Accuracy of dobutamine tetrofosmin myocardial perfusion imaging for the noninvasive diagnosis of transplant coronary artery stenosis. J Heart Lung Transplant 2000;19:360-6.CrossRefPubMed
18.
go back to reference Hacker M, Tausig A, Romuller B, et al. Dobutamine myocardial scintigraphy for the prediction of cardiac events after heart transplantation. Nucl Med Commun 2005;26:607-12.CrossRefPubMed Hacker M, Tausig A, Romuller B, et al. Dobutamine myocardial scintigraphy for the prediction of cardiac events after heart transplantation. Nucl Med Commun 2005;26:607-12.CrossRefPubMed
19.
go back to reference Wu YW, Yen RF, Lee CM, et al. Diagnostic and prognostic value of dobutamine thallium-201 single-photon emission computed tomography after heart transplantation. J Heart Lung Transplant 2005;24:544-50.CrossRefPubMed Wu YW, Yen RF, Lee CM, et al. Diagnostic and prognostic value of dobutamine thallium-201 single-photon emission computed tomography after heart transplantation. J Heart Lung Transplant 2005;24:544-50.CrossRefPubMed
20.
go back to reference Iskandrian AS, Heo J, Kong B, Lyons E. Effect of exercise level on the ability of thallium-201 tomographic imaging in detecting coronary artery disease: Analysis of 461 patients. J Am Coll Cardiol 1989;14:1477-86.CrossRefPubMed Iskandrian AS, Heo J, Kong B, Lyons E. Effect of exercise level on the ability of thallium-201 tomographic imaging in detecting coronary artery disease: Analysis of 461 patients. J Am Coll Cardiol 1989;14:1477-86.CrossRefPubMed
21.
go back to reference Candell-Riera J, Santana-Boado C, Castell-Conesa J, et al. Simultaneous dipyridamole/maximal subjective exercise with 99mTc-MIBI SPECT: Improved diagnostic yield in coronary artery disease. J Am Coll Cardiol 1997;29:531-6.CrossRefPubMed Candell-Riera J, Santana-Boado C, Castell-Conesa J, et al. Simultaneous dipyridamole/maximal subjective exercise with 99mTc-MIBI SPECT: Improved diagnostic yield in coronary artery disease. J Am Coll Cardiol 1997;29:531-6.CrossRefPubMed
22.
go back to reference Allen-Auerbach M, Schoder H, Johnson J, et al. Relationship between coronary function by positron emission tomography and temporal changes in morphology by intravascular ultrasound (IVUS) in transplant recipients. J Heart Lung Transplant 1999;18:211-9.CrossRefPubMed Allen-Auerbach M, Schoder H, Johnson J, et al. Relationship between coronary function by positron emission tomography and temporal changes in morphology by intravascular ultrasound (IVUS) in transplant recipients. J Heart Lung Transplant 1999;18:211-9.CrossRefPubMed
23.
go back to reference Verna E, Ceriani L, Giovanella L, Binaghi G, Garancini S. “False-positive” myocardial perfusion scintigraphy findings in patients with angiographically normal coronary arteries: Insights from intravascular sonography studies. J Nucl Med 2000;41:1935-40.PubMed Verna E, Ceriani L, Giovanella L, Binaghi G, Garancini S. “False-positive” myocardial perfusion scintigraphy findings in patients with angiographically normal coronary arteries: Insights from intravascular sonography studies. J Nucl Med 2000;41:1935-40.PubMed
24.
go back to reference Gregory SA, Ferencik M, Achenbach S, et al. Comparison of sixty-four-slice multidetector computed tomographic coronary angiography to coronary angiography with intravascular ultrasound for the detection of transplant vasculopathy. Am J Cardiol 2006;98:877-84.CrossRefPubMed Gregory SA, Ferencik M, Achenbach S, et al. Comparison of sixty-four-slice multidetector computed tomographic coronary angiography to coronary angiography with intravascular ultrasound for the detection of transplant vasculopathy. Am J Cardiol 2006;98:877-84.CrossRefPubMed
25.
go back to reference Romeo G, Houyel L, Angel CY, Brenot P, Riou JY, Paul JF. Coronary stenosis detection by 16-slice computed tomography in heart transplant patients: Comparison with conventional angiography and impact on clinical management. J Am Coll Cardiol 2005;45:1826-31.CrossRefPubMed Romeo G, Houyel L, Angel CY, Brenot P, Riou JY, Paul JF. Coronary stenosis detection by 16-slice computed tomography in heart transplant patients: Comparison with conventional angiography and impact on clinical management. J Am Coll Cardiol 2005;45:1826-31.CrossRefPubMed
26.
go back to reference Kuettner A, Beck T, Drosch T, et al. Image quality and diagnostic accuracy of non-invasive coronary imaging with 16 detector slice spiral computed tomography with 188 ms temporal resolution. Heart 2005;91:938-41.CrossRefPubMed Kuettner A, Beck T, Drosch T, et al. Image quality and diagnostic accuracy of non-invasive coronary imaging with 16 detector slice spiral computed tomography with 188 ms temporal resolution. Heart 2005;91:938-41.CrossRefPubMed
27.
go back to reference Einstein AJ, Henzlova MJ, Rajagopalan S. Estimating risk of cancer associated with radiation exposure from 64-slice computed tomography coronary angiography. JAMA 2007;298:317-23.CrossRefPubMed Einstein AJ, Henzlova MJ, Rajagopalan S. Estimating risk of cancer associated with radiation exposure from 64-slice computed tomography coronary angiography. JAMA 2007;298:317-23.CrossRefPubMed
28.
go back to reference Yamani MH, Haji SA, Starling RC, et al. Myocardial ischemic-fibrotic injury after human heart transplantation is associated with increased progression of vasculopathy, decreased cellular rejection and poor long-term outcome. J Am Coll Cardiol 2002;39:970-7.CrossRefPubMed Yamani MH, Haji SA, Starling RC, et al. Myocardial ischemic-fibrotic injury after human heart transplantation is associated with increased progression of vasculopathy, decreased cellular rejection and poor long-term outcome. J Am Coll Cardiol 2002;39:970-7.CrossRefPubMed
29.
go back to reference Weis M, Hartmann A, Olbrich HG, Hor G, Zeiher AM. Prognostic significance of coronary flow reserve on left ventricular ejection fraction in cardiac transplant recipients. Transplantation 1998;65:103-8.CrossRefPubMed Weis M, Hartmann A, Olbrich HG, Hor G, Zeiher AM. Prognostic significance of coronary flow reserve on left ventricular ejection fraction in cardiac transplant recipients. Transplantation 1998;65:103-8.CrossRefPubMed
30.
go back to reference Elhendy A, van Domburg RT, Vantrimpont P, et al. Prediction of mortality in heart transplant recipients by stress technetium-99m tetrofosmin myocardial perfusion imaging. Am J Cardiol 2002;89:964-8.CrossRefPubMed Elhendy A, van Domburg RT, Vantrimpont P, et al. Prediction of mortality in heart transplant recipients by stress technetium-99m tetrofosmin myocardial perfusion imaging. Am J Cardiol 2002;89:964-8.CrossRefPubMed
31.
go back to reference Redonnet M, Tron C, Koning R, et al. Coronary angioplasty and stenting in cardiac allograft vasculopathy following heart transplantation. Transplant Proc 2000;32:463-5.CrossRefPubMed Redonnet M, Tron C, Koning R, et al. Coronary angioplasty and stenting in cardiac allograft vasculopathy following heart transplantation. Transplant Proc 2000;32:463-5.CrossRefPubMed
32.
go back to reference Benza RL, Zoghbi GJ, Tallaj J, et al. Palliation of allograft vasculopathy with transluminal angioplasty: A decade of experience. J Am Coll Cardiol 2004;43:1973-81.CrossRefPubMed Benza RL, Zoghbi GJ, Tallaj J, et al. Palliation of allograft vasculopathy with transluminal angioplasty: A decade of experience. J Am Coll Cardiol 2004;43:1973-81.CrossRefPubMed
33.
go back to reference Carlsen J, Toft JC, Mortensen SA, Arendrup H, Aldershvile J, Hesse B. Myocardial perfusion scintigraphy as a screening method for significant coronary artery stenosis in cardiac transplant recipients. J Heart Lung Transplant 2000;19:873-8.CrossRefPubMed Carlsen J, Toft JC, Mortensen SA, Arendrup H, Aldershvile J, Hesse B. Myocardial perfusion scintigraphy as a screening method for significant coronary artery stenosis in cardiac transplant recipients. J Heart Lung Transplant 2000;19:873-8.CrossRefPubMed
34.
go back to reference Hachamovitch R, Berman DS, Kiat H, et al. Exercise myocardial perfusion SPECT in patients without known coronary artery disease: Incremental prognostic value and use in risk stratification. Circulation 1996;93:905-14.PubMed Hachamovitch R, Berman DS, Kiat H, et al. Exercise myocardial perfusion SPECT in patients without known coronary artery disease: Incremental prognostic value and use in risk stratification. Circulation 1996;93:905-14.PubMed
Metadata
Title
Diagnostic and prognostic value of myocardial perfusion gated SPECT in orthotopic heart transplant recipients
Authors
Alain Manrique, MD, PhD
Mathieu Bernard, MD
Anne Hitzel, MD
Michael Bubenheim, PhD
Christophe Tron, MD
Denis Agostini, MD, PhD
Alain Cribier
Pierre Véra, MD, PhD
Jean Paul Bessou, MD
Michel Redonnet, MD
Publication date
01-04-2010
Publisher
Springer-Verlag
Published in
Journal of Nuclear Cardiology / Issue 2/2010
Print ISSN: 1071-3581
Electronic ISSN: 1532-6551
DOI
https://doi.org/10.1007/s12350-009-9166-x

Other articles of this Issue 2/2010

Journal of Nuclear Cardiology 2/2010 Go to the issue