Skip to main content
Top
Published in: Neurocritical Care 2/2021

01-10-2021 | Subdural Hematoma | Original work

Prothrombin Complex Concentrate for Emergent Reversal of Intracranial Hemorrhage in Patients with Ventricular Assist Devices

Authors: Grace Y. Lai, Matthew B. Maas, Christopher R. Leong, Eric M. Liotta, Jonathan D. Rich, Duc T. Pham, Esther E. Vorovich, Andrew M. Naidech, Babak S. Jahromi, Matthew B. Potts

Published in: Neurocritical Care | Issue 2/2021

Login to get access

Abstract

Background

Intracranial hemorrhage (ICH) is a devastating complication for patients with ventricular assist devices (VADs). The safety of emergent anticoagulation reversal with four-factor prothrombin complex concentrate (PCC) and optimal timing of anticoagulation resumption are not clear. In addition, lactate dehydrogenase (LDH) is used as a biomarker for thromboembolic risk, but its utility in guiding anticoagulation management after reversal with PCC has not be described.

Methods

We retrospectively reviewed a consecutive series of patients with VADs presenting with ICH between 2014 and 2020 who received four-factor PCC for rapid anticoagulation reversal. We collected the timing of PCC administration, timing of resumption of anticoagulation, survival, occurrence of thromboembolic events, and LDH levels throughout hospitalization.

Results

We identified 16 ICH events in 14 patients with VADs treated with rapid anticoagulation reversal using four-factor PCC (11 intraparenchymal, 4 subdural, 1 subarachnoid hemorrhage). PCC was administered at a mean of 3.3 ± 0.3 h after imaging diagnosis of ICH. Overall mortality was 63%. Survivors had higher presenting Glasgow Coma Scale (median 15, interquartile range [IQR] 15–15 versus 14, IQR 8–14.7, P = 0.041). In all six instances where the patient survived, anticoagulation was resumed on average 9.16 ± 1.62 days after reversal. There were no thromboembolic events prior to resumption of anticoagulation. Three events occurred after anticoagulation resumption and within 3 months of reversal: VAD thrombosis in a patient with thrombosis at the time of reversal, ischemic stroke, and readmission for elevated LDH in the setting of subtherapeutic international normalized ratio.

Conclusions

Our limited series found no thromboembolic complications immediately following anticoagulation reversal with PCC prior to resumption of anticoagulation. LDH trends may be useful to monitor thromboembolic risk after reversal.
Literature
1.
go back to reference Colombo PC, Mehra MR, Goldstein DJ, Estep JD, Salerno C, Jorde UP, et al. Comprehensive analysis of stroke in the long-term cohort of the MOMENTUM 3 study. Circulation. 2019;139:155–68.CrossRef Colombo PC, Mehra MR, Goldstein DJ, Estep JD, Salerno C, Jorde UP, et al. Comprehensive analysis of stroke in the long-term cohort of the MOMENTUM 3 study. Circulation. 2019;139:155–68.CrossRef
2.
go back to reference Cho SM, Moazami N, Frontera JA. Stroke and intracranial hemorrhage in HeartMate II and HeartWare left ventricular assist devices: a systematic review. Neurocrit Care. 2017;27:17–25.CrossRef Cho SM, Moazami N, Frontera JA. Stroke and intracranial hemorrhage in HeartMate II and HeartWare left ventricular assist devices: a systematic review. Neurocrit Care. 2017;27:17–25.CrossRef
3.
go back to reference Rogers JG, Pagani FD, Tatooles AJ, Bhat G, Slaughter MS, Birks EJ, et al. Intrapericardial left ventricular assist device for advanced heart failure. N Engl J Med. 2017;376:451–60.CrossRef Rogers JG, Pagani FD, Tatooles AJ, Bhat G, Slaughter MS, Birks EJ, et al. Intrapericardial left ventricular assist device for advanced heart failure. N Engl J Med. 2017;376:451–60.CrossRef
4.
go back to reference Milano CA, Rogers JG, Tatooles AJ, Bhat G, Slaughter MS, Birks EJ, et al. HVAD: the ENDURANCE supplemental trial. JACC Heart Fail. 2018;6:792–802.CrossRef Milano CA, Rogers JG, Tatooles AJ, Bhat G, Slaughter MS, Birks EJ, et al. HVAD: the ENDURANCE supplemental trial. JACC Heart Fail. 2018;6:792–802.CrossRef
5.
go back to reference Florisson DS, Conte SM, De Bono JA, Newcomb AE. Do patients with the centrifugal flow HeartMate 3 or HeartWare left ventricular assist device have better outcomes compared to those with axial flow HeartMate II? Interact Cardiovasc Thorac Surg. 2019;29:844–51.CrossRef Florisson DS, Conte SM, De Bono JA, Newcomb AE. Do patients with the centrifugal flow HeartMate 3 or HeartWare left ventricular assist device have better outcomes compared to those with axial flow HeartMate II? Interact Cardiovasc Thorac Surg. 2019;29:844–51.CrossRef
6.
go back to reference Tsiouris A, Heliopoulos I, Mikroulis D, Mitsias PD. Factors defining occurrence of ischemic and hemorrhagic strokes during continuous flow left ventricular assist device support. Gen Thorac Cardiovasc Surg. 2020;68:319–27.CrossRef Tsiouris A, Heliopoulos I, Mikroulis D, Mitsias PD. Factors defining occurrence of ischemic and hemorrhagic strokes during continuous flow left ventricular assist device support. Gen Thorac Cardiovasc Surg. 2020;68:319–27.CrossRef
7.
go back to reference Shahreyar M, Bob-Manuel T, Khouzam RN, Bashir MW, Sulaiman S, Akinseye O, et al. Trends, predictors and outcomes of ischemic stroke and intracranial hemorrhage in patients with a left ventricular assist device. Ann Transl Med. 2018;6:5.CrossRef Shahreyar M, Bob-Manuel T, Khouzam RN, Bashir MW, Sulaiman S, Akinseye O, et al. Trends, predictors and outcomes of ischemic stroke and intracranial hemorrhage in patients with a left ventricular assist device. Ann Transl Med. 2018;6:5.CrossRef
8.
go back to reference Rossi M, Serraino GF, Jiritano F, Renzulli A. What is the optimal anticoagulation in patients with a left ventricular assist device? Interact Cardiovasc Thorac Surg. 2012;15:733–40.CrossRef Rossi M, Serraino GF, Jiritano F, Renzulli A. What is the optimal anticoagulation in patients with a left ventricular assist device? Interact Cardiovasc Thorac Surg. 2012;15:733–40.CrossRef
9.
go back to reference Slaughter MS, Rogers JG, Milano CA, Russell SD, Conte JV, Feldman D, et al. Advanced heart failure treated with continuous-flow left ventricular assist device. N Engl J Med. 2009;361:2241–51.CrossRef Slaughter MS, Rogers JG, Milano CA, Russell SD, Conte JV, Feldman D, et al. Advanced heart failure treated with continuous-flow left ventricular assist device. N Engl J Med. 2009;361:2241–51.CrossRef
10.
go back to reference Goldstein JN, Thomas SH, Frontiero V, Joseph A, Engel C, Snider R, et al. Timing of fresh frozen plasma administration and rapid correction of coagulopathy in warfarin-related intracerebral hemorrhage. Stroke. 2006;37:151–5.CrossRef Goldstein JN, Thomas SH, Frontiero V, Joseph A, Engel C, Snider R, et al. Timing of fresh frozen plasma administration and rapid correction of coagulopathy in warfarin-related intracerebral hemorrhage. Stroke. 2006;37:151–5.CrossRef
11.
go back to reference Kuramatsu JB, Gerner ST, Schellinger PD, Glahn J, Endres M, Sobesky J, et al. Anticoagulant reversal, blood pressure levels, and anticoagulant resumption in patients with anticoagulation-related intracerebral hemorrhage. JAMA. 2015;313:824–36.CrossRef Kuramatsu JB, Gerner ST, Schellinger PD, Glahn J, Endres M, Sobesky J, et al. Anticoagulant reversal, blood pressure levels, and anticoagulant resumption in patients with anticoagulation-related intracerebral hemorrhage. JAMA. 2015;313:824–36.CrossRef
12.
go back to reference Feldman D, Pamboukian SV, Teuteberg JJ, Birks E, Lietz K, Moore SA, et al. The 2013 International Society for Heart and Lung Transplantation Guidelines for mechanical circulatory support: executive summary. J Heart Lung Transplant. 2013;32:157–87.CrossRef Feldman D, Pamboukian SV, Teuteberg JJ, Birks E, Lietz K, Moore SA, et al. The 2013 International Society for Heart and Lung Transplantation Guidelines for mechanical circulatory support: executive summary. J Heart Lung Transplant. 2013;32:157–87.CrossRef
13.
go back to reference Wong JK, Chen PC, Falvey J, Melvin AL, Lidder AK, Lowenstein LM, et al. Anticoagulation reversal strategies for left ventricular assist device patients presenting with acute intracranial hemorrhage. ASAIO J. 2016;62:552–7.CrossRef Wong JK, Chen PC, Falvey J, Melvin AL, Lidder AK, Lowenstein LM, et al. Anticoagulation reversal strategies for left ventricular assist device patients presenting with acute intracranial hemorrhage. ASAIO J. 2016;62:552–7.CrossRef
14.
go back to reference Sarode R, Milling TJ Jr, Refaai MA, Mangione A, Schneider A, Durn BL, et al. Efficacy and safety of a 4-factor prothrombin complex concentrate in patients on vitamin K antagonists presenting with major bleeding: a randomized, plasma-controlled, phase IIIb study. Circulation. 2013;128:1234–43.CrossRef Sarode R, Milling TJ Jr, Refaai MA, Mangione A, Schneider A, Durn BL, et al. Efficacy and safety of a 4-factor prothrombin complex concentrate in patients on vitamin K antagonists presenting with major bleeding: a randomized, plasma-controlled, phase IIIb study. Circulation. 2013;128:1234–43.CrossRef
15.
go back to reference Steiner T, Poli S, Griebe M, Hüsing J, Hajda J, Freiberger A, et al. Fresh frozen plasma versus prothrombin complex concentrate in patients with intracranial haemorrhage related to vitamin K antagonists (INCH): a randomised trial. Lancet Neurol. 2016;15:566–73.CrossRef Steiner T, Poli S, Griebe M, Hüsing J, Hajda J, Freiberger A, et al. Fresh frozen plasma versus prothrombin complex concentrate in patients with intracranial haemorrhage related to vitamin K antagonists (INCH): a randomised trial. Lancet Neurol. 2016;15:566–73.CrossRef
16.
go back to reference Rimsans J, Levesque A, Lyons E, Sylvester K, Givertz MM, Mehra MR, et al. Four factor prothrombin complex concentrate for warfarin reversal in patients with left ventricular assist devices. J Thromb Thrombolysis. 2018;46:180–5.CrossRef Rimsans J, Levesque A, Lyons E, Sylvester K, Givertz MM, Mehra MR, et al. Four factor prothrombin complex concentrate for warfarin reversal in patients with left ventricular assist devices. J Thromb Thrombolysis. 2018;46:180–5.CrossRef
17.
go back to reference Cho SM, Moazami N, Katz S, Starling R, Frontera JA. Reversal and resumption of antithrombotic therapy in LVAD-associated intracranial hemorrhage. Ann Thorac Surg. 2019;108:52–8.CrossRef Cho SM, Moazami N, Katz S, Starling R, Frontera JA. Reversal and resumption of antithrombotic therapy in LVAD-associated intracranial hemorrhage. Ann Thorac Surg. 2019;108:52–8.CrossRef
18.
go back to reference Jennings DL, Rimsans J, Connors JM. Prothrombin complex concentrate for warfarin reversal in patients with continuous-flow left ventricular assist devices: a narrative review. ASAIO J. 2020;66:482–8.CrossRef Jennings DL, Rimsans J, Connors JM. Prothrombin complex concentrate for warfarin reversal in patients with continuous-flow left ventricular assist devices: a narrative review. ASAIO J. 2020;66:482–8.CrossRef
19.
go back to reference Sood V, Alam O, Tchantchaleishvili V, Pagani FD, Aaronson KD, Haft J, et al. Correlation of pre-explant lactate dehydrogenase concentrations and findings during post-explant pump analysis of the HeartMate II left ventricular assist device. Ann Thorac Surg. 2017;103:1207–13.CrossRef Sood V, Alam O, Tchantchaleishvili V, Pagani FD, Aaronson KD, Haft J, et al. Correlation of pre-explant lactate dehydrogenase concentrations and findings during post-explant pump analysis of the HeartMate II left ventricular assist device. Ann Thorac Surg. 2017;103:1207–13.CrossRef
20.
go back to reference Starling RC, Moazami N, Silvestry SC, Ewald G, Rogers JG, Milano CA, et al. Unexpected abrupt increase in left ventricular assist device thrombosis. N Engl J Med. 2014;370:33–40.CrossRef Starling RC, Moazami N, Silvestry SC, Ewald G, Rogers JG, Milano CA, et al. Unexpected abrupt increase in left ventricular assist device thrombosis. N Engl J Med. 2014;370:33–40.CrossRef
21.
go back to reference Hurst TE, Xanthopoulos A, Ehrlinger J, Rajeswaran J, Pande A, Thuita L, et al. Dynamic prediction of left ventricular assist device pump thrombosis based on lactate dehydrogenase trends. ESC Heart Fail. 2019;6:1005–14.CrossRef Hurst TE, Xanthopoulos A, Ehrlinger J, Rajeswaran J, Pande A, Thuita L, et al. Dynamic prediction of left ventricular assist device pump thrombosis based on lactate dehydrogenase trends. ESC Heart Fail. 2019;6:1005–14.CrossRef
22.
go back to reference Shah P, Mehta VM, Cowger JA, Aaronson KD, Pagani FD. Diagnosis of hemolysis and device thrombosis with lactate dehydrogenase during left ventricular assist device support. J Heart Lung Transplant. 2014;33:102–4.CrossRef Shah P, Mehta VM, Cowger JA, Aaronson KD, Pagani FD. Diagnosis of hemolysis and device thrombosis with lactate dehydrogenase during left ventricular assist device support. J Heart Lung Transplant. 2014;33:102–4.CrossRef
23.
go back to reference Lai GY, Devlin PJ, Kesavabhotla K, Rich JD, Pham DT, Potts MB, et al. Management and outcome of intracranial hemorrhage in patients with left ventricular assist devices. J Neurosurg. 2019;132:1133–9.CrossRef Lai GY, Devlin PJ, Kesavabhotla K, Rich JD, Pham DT, Potts MB, et al. Management and outcome of intracranial hemorrhage in patients with left ventricular assist devices. J Neurosurg. 2019;132:1133–9.CrossRef
24.
go back to reference Kothari RU, Brott T, Broderick JP, Barsan WG, Sauerbeck LR, Zuccarello M, et al. The ABCs of measuring intracerebral hemorrhage volumes. Stroke. 1996;27:1304–5.CrossRef Kothari RU, Brott T, Broderick JP, Barsan WG, Sauerbeck LR, Zuccarello M, et al. The ABCs of measuring intracerebral hemorrhage volumes. Stroke. 1996;27:1304–5.CrossRef
25.
go back to reference Won SY, Zagorcic A, Dubinski D, Quick-Weller J, Herrmann E, Seifert V, et al. Excellent accuracy of ABC/2 volume formula compared to computer-assisted volumetric analysis of subdural hematomas. PLoS ONE. 2018;13:e0199809.CrossRef Won SY, Zagorcic A, Dubinski D, Quick-Weller J, Herrmann E, Seifert V, et al. Excellent accuracy of ABC/2 volume formula compared to computer-assisted volumetric analysis of subdural hematomas. PLoS ONE. 2018;13:e0199809.CrossRef
26.
go back to reference Carroll AH, Ramirez MP, Dowlati E, Mueller KB, Borazjani A, Chang JJ, et al. Management of intracranial hemorrhage in patients with a left ventricular assist device: a systematic review and meta-analysis. J Stroke Cerebrovasc Dis. 2021;30:105501.CrossRef Carroll AH, Ramirez MP, Dowlati E, Mueller KB, Borazjani A, Chang JJ, et al. Management of intracranial hemorrhage in patients with a left ventricular assist device: a systematic review and meta-analysis. J Stroke Cerebrovasc Dis. 2021;30:105501.CrossRef
27.
go back to reference Wilson TJ, Stetler WR Jr, Al-Holou WN, Sullivan SE, Fletcher JJ. Management of intracranial hemorrhage in patients with left ventricular assist devices. J Neurosurg. 2013;118:1063–8.CrossRef Wilson TJ, Stetler WR Jr, Al-Holou WN, Sullivan SE, Fletcher JJ. Management of intracranial hemorrhage in patients with left ventricular assist devices. J Neurosurg. 2013;118:1063–8.CrossRef
28.
go back to reference Willey JZ, Gavalas MV, Trinh PN, Yuzefpolskaya M, Reshad Garan A, Levin AP, et al. Outcomes after stroke complicating left ventricular assist device. J Heart Lung Transplant. 2016;35:1003–9.CrossRef Willey JZ, Gavalas MV, Trinh PN, Yuzefpolskaya M, Reshad Garan A, Levin AP, et al. Outcomes after stroke complicating left ventricular assist device. J Heart Lung Transplant. 2016;35:1003–9.CrossRef
29.
go back to reference Brekelmans MPA, Abdoellakhan RA, Scheres LJJ, Biedermann JS, Hutten BA, Meijer K, et al. Clinical outcome of patients with a vitamin K antagonist-associated bleeding treated with prothrombin complex concentrate. Res Pract Thromb Haemost. 2018;2:77–84.CrossRef Brekelmans MPA, Abdoellakhan RA, Scheres LJJ, Biedermann JS, Hutten BA, Meijer K, et al. Clinical outcome of patients with a vitamin K antagonist-associated bleeding treated with prothrombin complex concentrate. Res Pract Thromb Haemost. 2018;2:77–84.CrossRef
30.
go back to reference Santos CD, Matos NL, Asleh R, Dawit S, Rabinstein AA, O’Carroll CB, et al. The dilemma of resuming antithrombotic therapy after intracranial hemorrhage in patients with left ventricular assist devices. Neurocrit Care. 2020;32:822–7.CrossRef Santos CD, Matos NL, Asleh R, Dawit S, Rabinstein AA, O’Carroll CB, et al. The dilemma of resuming antithrombotic therapy after intracranial hemorrhage in patients with left ventricular assist devices. Neurocrit Care. 2020;32:822–7.CrossRef
Metadata
Title
Prothrombin Complex Concentrate for Emergent Reversal of Intracranial Hemorrhage in Patients with Ventricular Assist Devices
Authors
Grace Y. Lai
Matthew B. Maas
Christopher R. Leong
Eric M. Liotta
Jonathan D. Rich
Duc T. Pham
Esther E. Vorovich
Andrew M. Naidech
Babak S. Jahromi
Matthew B. Potts
Publication date
01-10-2021
Publisher
Springer US
Published in
Neurocritical Care / Issue 2/2021
Print ISSN: 1541-6933
Electronic ISSN: 1556-0961
DOI
https://doi.org/10.1007/s12028-021-01210-7

Other articles of this Issue 2/2021

Neurocritical Care 2/2021 Go to the issue