Skip to main content
Top
Published in: Forensic Science, Medicine and Pathology 2/2013

01-06-2013 | Original Article

Material differentiation in forensic radiology with single-source dual-energy computed tomography

Authors: Thomas D. Ruder, Yannick Thali, Stephan A. Bolliger, Sandra Somaini-Mathier, Michael J. Thali, Gary M. Hatch, Sebastian T. Schindera

Published in: Forensic Science, Medicine and Pathology | Issue 2/2013

Login to get access

Abstract

The goal of this study was to investigate the use of dual-energy computed tomography (CT) in differentiating frequently encountered foreign material on CT images using a standard single-source CT scanner. We scanned 20 different, forensically relevant materials at two X-Ray energy levels (80 and 130 kVp) on CT. CT values were measured in each object at both energy levels. Intraclass correlation coefficient (ICC) was used to determine intra-reader reliability. Analysis of variance (ANOVA) was performed to assess significance levels between X-Ray attenuation at 80 and 130 kVp. T test was used to investigate significance levels between mean HU values of individual object pairings at single energy levels of 80 and 130 kVp, respectively. ANOVA revealed that the difference in attenuation between beam energies of 80 kVp compared to 130 kVp was statistically significant (p < 0.005) for all materials except brass and lead. ICC was excellent at 80 kVp (0.999, p < 0.001) and at 130 kVp (0.998, p < 0.001). T test showed that using single energy levels of 80 and 130 kVp respectively 181/190 objects pairs could be differentiated from one another based on HU measurements. Using the combined information from both energy levels, 189/190 object pairs could be differentiated. Scanning with different energy levels is a simple way to apply dual-energy technique on a regular single-energy CT and improves the ability to differentiate foreign bodies with CT, based on their attenuation values.
Literature
1.
go back to reference Brogdon BG, Lichtenstein JE. Forensic radiology in historical perspective. In: Brogdon BG, editor. Forensic radiology. Boca Raton: CRC Press; 1998. p. 13–34.CrossRef Brogdon BG, Lichtenstein JE. Forensic radiology in historical perspective. In: Brogdon BG, editor. Forensic radiology. Boca Raton: CRC Press; 1998. p. 13–34.CrossRef
2.
go back to reference Brogdon BG, Lichtenstein JE. Scope of forensic radiology. In: Brogdon BG, editor. Forensic radiology. Boca Raton: CRC Press; 1998. p. 35–52.CrossRef Brogdon BG, Lichtenstein JE. Scope of forensic radiology. In: Brogdon BG, editor. Forensic radiology. Boca Raton: CRC Press; 1998. p. 35–52.CrossRef
3.
go back to reference Thali MJ, Yen K, Schweitzer W, Vock P, Boesch C, Ozdoba C, Schroth G, Ith M, Sonnenschein M, Doernhoefer T, Scheurer E, Plattner T, Dirnhofer R. Virtopsy, a new imaging horizon in forensic pathology: virtual autopsy by postmortem multislice computed tomography (MSCT) and magnetic resonance imaging (MRI)—a feasibility study. J Forensic Sci. 2003;48:386–403.PubMed Thali MJ, Yen K, Schweitzer W, Vock P, Boesch C, Ozdoba C, Schroth G, Ith M, Sonnenschein M, Doernhoefer T, Scheurer E, Plattner T, Dirnhofer R. Virtopsy, a new imaging horizon in forensic pathology: virtual autopsy by postmortem multislice computed tomography (MSCT) and magnetic resonance imaging (MRI)—a feasibility study. J Forensic Sci. 2003;48:386–403.PubMed
4.
go back to reference Rutty GN, Morgan B, O’Donnell C, Leth PM, Thali M. Forensic institutes across the world place CT or MRI scanners or both into their mortuaries. J Trauma. 2008;65:493–4.PubMedCrossRef Rutty GN, Morgan B, O’Donnell C, Leth PM, Thali M. Forensic institutes across the world place CT or MRI scanners or both into their mortuaries. J Trauma. 2008;65:493–4.PubMedCrossRef
5.
go back to reference Thali MJ, Dirnhofer R, Vock P. The virtopsy approach. 1st ed. Boca Raton: CRC Press Taylor & Francis Group; 2009.CrossRef Thali MJ, Dirnhofer R, Vock P. The virtopsy approach. 1st ed. Boca Raton: CRC Press Taylor & Francis Group; 2009.CrossRef
6.
go back to reference O’Donnell C, Iino M, Mansharan K, Leditscke J, Woodford N. Contribution of postmortem multidetector CT scanning to identification of the deceased in a mass disaster: experience gained from the 2009 Victorian bushfires. Forensic Sci Int. 2011;205:15–28.PubMedCrossRef O’Donnell C, Iino M, Mansharan K, Leditscke J, Woodford N. Contribution of postmortem multidetector CT scanning to identification of the deceased in a mass disaster: experience gained from the 2009 Victorian bushfires. Forensic Sci Int. 2011;205:15–28.PubMedCrossRef
7.
go back to reference Weissleder R, Wittenberg J, Harisinghani MG, Chen JW. Imaging Physics. In: Weissleder R, Wittenberg J, Harisinghani MG, Chen JW, editors. Primer of diagnostic imaging. Philadelphia: Mosby Elsevier; 2007. p. 989–1069. Weissleder R, Wittenberg J, Harisinghani MG, Chen JW. Imaging Physics. In: Weissleder R, Wittenberg J, Harisinghani MG, Chen JW, editors. Primer of diagnostic imaging. Philadelphia: Mosby Elsevier; 2007. p. 989–1069.
8.
go back to reference Huda W, Slone R. Computed tomography. In: Huda W, Slone R, editors. Review of radiologic physics. Philadelphia: Lippincott Williams & Wilkins; 2003. p. 121–36. Huda W, Slone R. Computed tomography. In: Huda W, Slone R, editors. Review of radiologic physics. Philadelphia: Lippincott Williams & Wilkins; 2003. p. 121–36.
9.
go back to reference Bolliger SA, Oesterhelweg L, Spendlove D, Ross S, Thali MJ. Is differentiation of frequently encountered foreign bodies in corpses possible by Hounsfield density measurement? J Forensic Sci. 2009;54:1119–22.PubMedCrossRef Bolliger SA, Oesterhelweg L, Spendlove D, Ross S, Thali MJ. Is differentiation of frequently encountered foreign bodies in corpses possible by Hounsfield density measurement? J Forensic Sci. 2009;54:1119–22.PubMedCrossRef
10.
go back to reference Jackowski C, Lussi A, Classens M, Kilchoer T, Bolliger S, Aghayev E, et al. Extended CT scale overcomes restoration caused streak artifacts for dental identification in CT-3D color encoded automatic discrimination of dental restorations. J Comput Assist Tomogr. 2006;30:510–3.PubMedCrossRef Jackowski C, Lussi A, Classens M, Kilchoer T, Bolliger S, Aghayev E, et al. Extended CT scale overcomes restoration caused streak artifacts for dental identification in CT-3D color encoded automatic discrimination of dental restorations. J Comput Assist Tomogr. 2006;30:510–3.PubMedCrossRef
11.
go back to reference Flohr TG, McCollough CH, Bruder H, Petersilka M, Gruber K, Süss C, et al. First performance evaluation of a dual-source CT (DSCT) system. Eur Radiol. 2006;16:256–68.PubMedCrossRef Flohr TG, McCollough CH, Bruder H, Petersilka M, Gruber K, Süss C, et al. First performance evaluation of a dual-source CT (DSCT) system. Eur Radiol. 2006;16:256–68.PubMedCrossRef
12.
go back to reference Johnson TR, Krauss B, Sedlmair M, Grasruck M, Bruder H, Morhard D, et al. Material differentiation by dual energy CT: initial experience. Eur Radiol. 2007;17:1510–7.PubMedCrossRef Johnson TR, Krauss B, Sedlmair M, Grasruck M, Bruder H, Morhard D, et al. Material differentiation by dual energy CT: initial experience. Eur Radiol. 2007;17:1510–7.PubMedCrossRef
13.
go back to reference Coursey CA, Nelson RC, Boll DT, Paulson EK, Ho LM, Neville AM, et al. Dual-energy multidetector CT: how does it work, what can it tell us, and when can we use it in abdominopelvic imaging? Radiographics. 2010;30:1037–55.PubMedCrossRef Coursey CA, Nelson RC, Boll DT, Paulson EK, Ho LM, Neville AM, et al. Dual-energy multidetector CT: how does it work, what can it tell us, and when can we use it in abdominopelvic imaging? Radiographics. 2010;30:1037–55.PubMedCrossRef
14.
go back to reference Pache G, Krauss B, Strohm P, Saueressig U, Blanke P, Bulla S, Schäfer O, Helwig P, Kotter E, Langer M, Baumann T. Dual-energy CT virtual noncalcium technique: detecting posttraumatic bone marrow lesions–feasibility study. Radiology. 2010;256:617–24.PubMedCrossRef Pache G, Krauss B, Strohm P, Saueressig U, Blanke P, Bulla S, Schäfer O, Helwig P, Kotter E, Langer M, Baumann T. Dual-energy CT virtual noncalcium technique: detecting posttraumatic bone marrow lesions–feasibility study. Radiology. 2010;256:617–24.PubMedCrossRef
15.
go back to reference Johnson TRC, Fink C, Schönberg SO, Reiser MF. Dual energy CT in clinical practice. 1st ed. Berlin: Springer; 2011.CrossRef Johnson TRC, Fink C, Schönberg SO, Reiser MF. Dual energy CT in clinical practice. 1st ed. Berlin: Springer; 2011.CrossRef
16.
go back to reference Guggenberger R, Winklhofer S, Osterhoff G, Wanner GA, Fortunati M, Andreisek G, Alkadhi H, Stolzmann P. Metallic artefact reduction with monoenergetic dual-energy CT: systematic ex vivo evaluation of posterior spinal fusion implants from various vendors and different spine levels. Eur Radiol. 2012;22:2357–64.PubMedCrossRef Guggenberger R, Winklhofer S, Osterhoff G, Wanner GA, Fortunati M, Andreisek G, Alkadhi H, Stolzmann P. Metallic artefact reduction with monoenergetic dual-energy CT: systematic ex vivo evaluation of posterior spinal fusion implants from various vendors and different spine levels. Eur Radiol. 2012;22:2357–64.PubMedCrossRef
17.
go back to reference Persson A, Jackowski C, Engström E, Zachrisson H. Advances of dual source, dual-energy imaging in postmortem CT. Eur J Radiol. 2008;68:446–55.PubMedCrossRef Persson A, Jackowski C, Engström E, Zachrisson H. Advances of dual source, dual-energy imaging in postmortem CT. Eur J Radiol. 2008;68:446–55.PubMedCrossRef
18.
go back to reference Jackowski C, Thali MJ. Radiologic Identification. In: Thali MJ, Dirnhofer R, Vock P, editors. The virtopsy approach. Boca Raton: CRC Press Taylor & Francis Group; 2009. p. 169–85. Jackowski C, Thali MJ. Radiologic Identification. In: Thali MJ, Dirnhofer R, Vock P, editors. The virtopsy approach. Boca Raton: CRC Press Taylor & Francis Group; 2009. p. 169–85.
19.
go back to reference Ruder TD, Thali Y, Schindera ST, Dalla Torre SA, Zech WD, Thali MJ, Ross S, Hatch GM. How reliable are Hounsfield-unit measurements in forensic radiology? Forensic Sci Int. 2012;220:219–23.PubMedCrossRef Ruder TD, Thali Y, Schindera ST, Dalla Torre SA, Zech WD, Thali MJ, Ross S, Hatch GM. How reliable are Hounsfield-unit measurements in forensic radiology? Forensic Sci Int. 2012;220:219–23.PubMedCrossRef
20.
go back to reference Woisetschläger M, Lussi A, Persson A, Jackowski C. Fire victim identification by post-mortem dental CT: radiologic evaluation of restorative materials after exposure to high temperatures. Eur J Radiol. 2011;80:432–40.PubMedCrossRef Woisetschläger M, Lussi A, Persson A, Jackowski C. Fire victim identification by post-mortem dental CT: radiologic evaluation of restorative materials after exposure to high temperatures. Eur J Radiol. 2011;80:432–40.PubMedCrossRef
21.
Metadata
Title
Material differentiation in forensic radiology with single-source dual-energy computed tomography
Authors
Thomas D. Ruder
Yannick Thali
Stephan A. Bolliger
Sandra Somaini-Mathier
Michael J. Thali
Gary M. Hatch
Sebastian T. Schindera
Publication date
01-06-2013
Publisher
Springer US
Published in
Forensic Science, Medicine and Pathology / Issue 2/2013
Print ISSN: 1547-769X
Electronic ISSN: 1556-2891
DOI
https://doi.org/10.1007/s12024-012-9398-y

Other articles of this Issue 2/2013

Forensic Science, Medicine and Pathology 2/2013 Go to the issue