Skip to main content
Top
Published in: Clinical Orthopaedics and Related Research® 1/2017

01-01-2017 | Symposium: 2016 Knee Society Proceedings

The Chitranjan S. Ranawat Award

No Difference in 2-year Functional Outcomes Using Kinematic versus Mechanical Alignment in TKA: A Randomized Controlled Clinical Trial

Authors: Simon W. Young, FRACS, Matthew L. Walker, FRACS, Ali Bayan, FRACS, Toby Briant-Evans, FRCS, Paul Pavlou, FRCS, Bill Farrington, FRCS, FRACS

Published in: Clinical Orthopaedics and Related Research® | Issue 1/2017

Login to get access

Abstract

Background

Neutral mechanical alignment (MA) in total knee arthroplasty (TKA) aims to position femoral and tibial components perpendicular to the mechanical axis of the limb. In contrast, kinematic alignment (KA) attempts to match implant position to the prearthritic anatomy of the individual patient with the aim of improving functional outcome. However, comparative data between the two techniques are lacking.

Questions/purposes

In this randomized trial, we asked: (1) Are 2-year patient-reported outcome scores enhanced in patients with KA compared with an MA technique? (2) How does postoperative component alignment differ between the techniques? (3) Is the proportion of patients undergoing reoperation at 2 years different between the techniques?

Methods

Ninety-nine primary TKAs in 95 patients were randomized to either MA (n = 50) or KA (n = 49) groups. A pilot study of 20 TKAs was performed before this trial using the same patient-specific guides positioning in kinematic alignment. In the KA group, patient-specific cutting blocks were manufactured using individual preoperative MRI data. In the MA group, computer navigation was used to ensure neutral mechanical alignment accuracy. Postoperative alignment was assessed with CT scan, and functional scores (including the Oxford Knee Score, WOMAC, and the Forgotten Joint Score) were assessed preoperatively and at 6 weeks, 6 months, and 1 and 2 years postoperatively. No patients were lost to followup. We set sample size at a minimum of 45 patients per treatment arm based on a 5-point improvement in the mean Oxford Knee Score (OKS; the previously reported minimum clinically significant difference for the OKS in TKA), a pooled SD of 8.3, 80% power, and a two-sided significance level of 5%.

Results

We observed no difference in 2-year change scores (postoperative minus preoperative score) in KA versus MA patients for the OKS (mean 21, SD 8 versus 20, SD 8, least square means 1.0, 95% confidence interval [CI], −1.4 to 3.4, p = 0.4), WOMAC score (mean 38, SD 18 versus 35, SD 8, least square means 3, 95% CI, −3.2 to 8.9, p = 0.3), or Forgotten Joint score (28 SD 37 versus 28, SD 28, least square means 0.8, 95% CI, −9.1–10.7, p = 0.8). Postoperative hip-knee-ankle axis was not different between groups (mean KA 0.4° varus SD 3.5 versus MA 0.7° varus SD 2.0), but in the KA group, the tibial component was a mean 1.9° more varus than the MA group (95% CI, 0.8°−3.0°, p = 0.003) and the femoral component in 1.6° more valgus (95% CI, −2.5° to −0.7°, p = 0.003). Complication rates were not different between groups.

Conclusions

We found no difference in 2-year patient-reported outcome scores in TKAs implanted using the KA versus an MA technique. The theoretical advantages of improved pain and function that form the basis of the design rationale of KA were not observed in this study. Currently, it is unknown whether the alterations in component alignment seen with KA will compromise long-term survivorship of TKA. In this study, we were unable to demonstrate an advantage to KA in terms of pain or function that would justify this risk.

Level of Evidence

Level I, therapeutic study.
Literature
1.
go back to reference Aglietti P, Buzzi R. Posteriorly stabilised total-condylar knee replacement. Three to eight years’ follow-up of 85 knees. J Bone Joint Surg Br. 1988;70:211–216.PubMed Aglietti P, Buzzi R. Posteriorly stabilised total-condylar knee replacement. Three to eight years’ follow-up of 85 knees. J Bone Joint Surg Br. 1988;70:211–216.PubMed
2.
go back to reference Arima J, Whiteside LA, McCarthy DS, White SE. Femoral rotational alignment, based on the anteroposterior axis, in total knee arthroplasty in a valgus knee. A technical note. J Bone Joint Surg Am. 1995;77:1331–1334.CrossRefPubMed Arima J, Whiteside LA, McCarthy DS, White SE. Femoral rotational alignment, based on the anteroposterior axis, in total knee arthroplasty in a valgus knee. A technical note. J Bone Joint Surg Am. 1995;77:1331–1334.CrossRefPubMed
3.
go back to reference Bargren JH, Blaha JD, Freeman MA. Alignment in total knee arthroplasty. Correlated biomechanical and clinical observations. Clin Orthop Relat Res. 1983;173:178–183. Bargren JH, Blaha JD, Freeman MA. Alignment in total knee arthroplasty. Correlated biomechanical and clinical observations. Clin Orthop Relat Res. 1983;173:178–183.
4.
go back to reference Behrend H, Giesinger K, Giesinger JM, Kuster MS. The ‘forgotten joint’ as the ultimate goal in joint arthroplasty: validation of a new patient-reported outcome measure. J Arthroplasty. 2012;27:430–436.e1. Behrend H, Giesinger K, Giesinger JM, Kuster MS. The ‘forgotten joint’ as the ultimate goal in joint arthroplasty: validation of a new patient-reported outcome measure. J Arthroplasty. 2012;27:430–436.e1.
5.
go back to reference Bellemans J. Neutral mechanical alignment: a requirement for successful TKA: opposes. Orthopedics. 2011;34:e507–509.CrossRefPubMed Bellemans J. Neutral mechanical alignment: a requirement for successful TKA: opposes. Orthopedics. 2011;34:e507–509.CrossRefPubMed
6.
go back to reference Bellemans J, Colyn W, Vandenneucker H, Victor J. The Chitranjan Ranawat Award: Is neutral mechanical alignment normal for all patients? The concept of constitutional varus. Clin Orthop Relat Res. 2012;470:45–53.CrossRefPubMed Bellemans J, Colyn W, Vandenneucker H, Victor J. The Chitranjan Ranawat Award: Is neutral mechanical alignment normal for all patients? The concept of constitutional varus. Clin Orthop Relat Res. 2012;470:45–53.CrossRefPubMed
7.
go back to reference Bellemans J, Vandenneucker H, Van Lauwe J, Victor J. A new surgical technique for medial collateral ligament balancing: multiple needle puncturing. J Arthroplasty. 2010;25:1151–1156.CrossRefPubMed Bellemans J, Vandenneucker H, Van Lauwe J, Victor J. A new surgical technique for medial collateral ligament balancing: multiple needle puncturing. J Arthroplasty. 2010;25:1151–1156.CrossRefPubMed
8.
go back to reference Berend ME, Ritter MA, Meding JB, Faris PM, Keating EM, Redelman R, Faris GW, Davis KE. Tibial component failure mechanisms in total knee arthroplasty. Clin Orthop Relat Res. 2004;428:26–34.CrossRef Berend ME, Ritter MA, Meding JB, Faris PM, Keating EM, Redelman R, Faris GW, Davis KE. Tibial component failure mechanisms in total knee arthroplasty. Clin Orthop Relat Res. 2004;428:26–34.CrossRef
9.
go back to reference Berger RA, Crossett LS, Jacobs JJ, Rubash HE. Malrotation causing patellofemoral complications after total knee arthroplasty. Clin Orthop Relat Res. 1998;356:144–153.CrossRef Berger RA, Crossett LS, Jacobs JJ, Rubash HE. Malrotation causing patellofemoral complications after total knee arthroplasty. Clin Orthop Relat Res. 1998;356:144–153.CrossRef
10.
go back to reference Boldt JG, Stiehl JB, Hodler J, Zanetti M, Munzinger U. Femoral component rotation and arthrofibrosis following mobile-bearing total knee arthroplasty. Int Orthop. 2006;30:420–425.CrossRefPubMedPubMedCentral Boldt JG, Stiehl JB, Hodler J, Zanetti M, Munzinger U. Femoral component rotation and arthrofibrosis following mobile-bearing total knee arthroplasty. Int Orthop. 2006;30:420–425.CrossRefPubMedPubMedCentral
12.
go back to reference Chauhan SK, Clark GW, Lloyd S, Scott RG, Breidahl W, Sikorski JM. Computer-assisted total knee replacement. A controlled cadaver study using a multi-parameter quantitative CT assessment of alignment (the Perth CT Protocol). J Bone Joint Surg Br. 2004;86:818–823.CrossRefPubMed Chauhan SK, Clark GW, Lloyd S, Scott RG, Breidahl W, Sikorski JM. Computer-assisted total knee replacement. A controlled cadaver study using a multi-parameter quantitative CT assessment of alignment (the Perth CT Protocol). J Bone Joint Surg Br. 2004;86:818–823.CrossRefPubMed
13.
go back to reference Clark G, Leong A, McEwen P, Steele R, Tran T, Trivett A. Intra-operative reliability of ShapeMatch cutting guide placement in total knee arthroplasty. Comput Aided Surg. 2013;18:159–165.CrossRefPubMed Clark G, Leong A, McEwen P, Steele R, Tran T, Trivett A. Intra-operative reliability of ShapeMatch cutting guide placement in total knee arthroplasty. Comput Aided Surg. 2013;18:159–165.CrossRefPubMed
14.
go back to reference Dossett HG, Estrada NA, Swartz GJ, LeFevre GW, Kwasman BG. A randomised controlled trial of kinematically and mechanically aligned total knee replacements: two-year clinical results. Bone Joint J. 2014;96:907–913.CrossRefPubMed Dossett HG, Estrada NA, Swartz GJ, LeFevre GW, Kwasman BG. A randomised controlled trial of kinematically and mechanically aligned total knee replacements: two-year clinical results. Bone Joint J. 2014;96:907–913.CrossRefPubMed
15.
go back to reference Dossett HG, Swartz GJ, Estrada NA, LeFevre GW, Kwasman BG. Kinematically versus mechanically aligned total knee arthroplasty. Orthopedics. 2012;35:e160–169.PubMed Dossett HG, Swartz GJ, Estrada NA, LeFevre GW, Kwasman BG. Kinematically versus mechanically aligned total knee arthroplasty. Orthopedics. 2012;35:e160–169.PubMed
16.
go back to reference Eckhoff D, Hogan C, DiMatteo L, Robinson M, Bach J. Difference between the epicondylar and cylindrical axis of the knee. Clin Orthop Relat Res. 2007;461:238–244.PubMed Eckhoff D, Hogan C, DiMatteo L, Robinson M, Bach J. Difference between the epicondylar and cylindrical axis of the knee. Clin Orthop Relat Res. 2007;461:238–244.PubMed
17.
go back to reference Eckhoff DG, Bach JM, Spitzer VM, Reinig KD, Bagur MM, Baldini TH, Flannery NMP. Three-dimensional mechanics, kinematics, and morphology of the knee viewed in virtual reality. J Bone Joint Surg Am. 2005;87(Suppl 2):71–80.PubMed Eckhoff DG, Bach JM, Spitzer VM, Reinig KD, Bagur MM, Baldini TH, Flannery NMP. Three-dimensional mechanics, kinematics, and morphology of the knee viewed in virtual reality. J Bone Joint Surg Am. 2005;87(Suppl 2):71–80.PubMed
18.
go back to reference Fang DM, Ritter MA, Davis KE. Coronal alignment in total knee arthroplasty: just how important is it? J Arthroplasty. 2009;24:39–43.CrossRefPubMed Fang DM, Ritter MA, Davis KE. Coronal alignment in total knee arthroplasty: just how important is it? J Arthroplasty. 2009;24:39–43.CrossRefPubMed
19.
go back to reference Green GV, Berend KR, Berend ME, Glisson RR, Vail TP. The effects of varus tibial alignment on proximal tibial surface strain in total knee arthroplasty: the posteromedial hot spot. J Arthroplasty. 2002;17:1033–1039.CrossRefPubMed Green GV, Berend KR, Berend ME, Glisson RR, Vail TP. The effects of varus tibial alignment on proximal tibial surface strain in total knee arthroplasty: the posteromedial hot spot. J Arthroplasty. 2002;17:1033–1039.CrossRefPubMed
20.
go back to reference Halder A, Kutzner I, Graichen F, Heinlein B, Beier A, Bergmann G. Influence of limb alignment on mediolateral loading in total knee replacement: in vivo measurements in five patients. J Bone Joint Surg Am. 2012;94:1023–1029.CrossRefPubMed Halder A, Kutzner I, Graichen F, Heinlein B, Beier A, Bergmann G. Influence of limb alignment on mediolateral loading in total knee replacement: in vivo measurements in five patients. J Bone Joint Surg Am. 2012;94:1023–1029.CrossRefPubMed
21.
go back to reference Howell SM, Howell SJ, Hull ML. Assessment of the radii of the medial and lateral femoral condyles in varus and valgus knees with osteoarthritis. J Bone Joint Surg Am. 2010;92:98–104.CrossRefPubMed Howell SM, Howell SJ, Hull ML. Assessment of the radii of the medial and lateral femoral condyles in varus and valgus knees with osteoarthritis. J Bone Joint Surg Am. 2010;92:98–104.CrossRefPubMed
22.
go back to reference Howell SM, Howell SJ, Kuznik KT, Cohen J, Hull ML. Does a kinematically aligned total knee arthroplasty restore function without failure regardless of alignment category? Clin Orthop Relat Res. 2013;471:1000–1007.CrossRefPubMed Howell SM, Howell SJ, Kuznik KT, Cohen J, Hull ML. Does a kinematically aligned total knee arthroplasty restore function without failure regardless of alignment category? Clin Orthop Relat Res. 2013;471:1000–1007.CrossRefPubMed
23.
go back to reference Howell SM, Hull ML. Kinematic alignment in total knee arthroplasty. In: Scott WN, ed. Insall and Scott Surgery of the Knee. Philadelphia, PA, USA: Elsevier; 2012:1255–1268.CrossRef Howell SM, Hull ML. Kinematic alignment in total knee arthroplasty. In: Scott WN, ed. Insall and Scott Surgery of the Knee. Philadelphia, PA, USA: Elsevier; 2012:1255–1268.CrossRef
24.
go back to reference Howell SM, Papadopoulos S, Kuznik K, Ghaly LR, Hull ML. Does varus alignment adversely affect implant survival and function six years after kinematically aligned total knee arthroplasty? Int Orthop. 2015;39:2117–2124.CrossRefPubMed Howell SM, Papadopoulos S, Kuznik K, Ghaly LR, Hull ML. Does varus alignment adversely affect implant survival and function six years after kinematically aligned total knee arthroplasty? Int Orthop. 2015;39:2117–2124.CrossRefPubMed
25.
go back to reference Howell SM, Papadopoulos S, Kuznik KT, Hull ML. Accurate alignment and high function after kinematically aligned TKA performed with generic instruments. Knee Surg Sports Traumatol Arthrosc. 2013;21:2271–2280.CrossRefPubMed Howell SM, Papadopoulos S, Kuznik KT, Hull ML. Accurate alignment and high function after kinematically aligned TKA performed with generic instruments. Knee Surg Sports Traumatol Arthrosc. 2013;21:2271–2280.CrossRefPubMed
26.
go back to reference Insall JN, Dorr LD, Scott RD, Scott WN. Rationale of the Knee Society clinical rating system. Clin Orthop Relat Res. 1989;248:13–14. Insall JN, Dorr LD, Scott RD, Scott WN. Rationale of the Knee Society clinical rating system. Clin Orthop Relat Res. 1989;248:13–14.
27.
go back to reference Jeffery RS, Morris RW, Denham RA. Coronal alignment after total knee replacement. J Bone Joint Surg Br. 1991;73:709–714.PubMed Jeffery RS, Morris RW, Denham RA. Coronal alignment after total knee replacement. J Bone Joint Surg Br. 1991;73:709–714.PubMed
28.
go back to reference Kamat YD, Aurakzai KM, Adhikari AR, Matthews D, Kalairajah Y, Field RE. Does computer navigation in total knee arthroplasty improve patient outcome at midterm follow-up? Int Orthop. 2009;33:1567–1570.CrossRefPubMed Kamat YD, Aurakzai KM, Adhikari AR, Matthews D, Kalairajah Y, Field RE. Does computer navigation in total knee arthroplasty improve patient outcome at midterm follow-up? Int Orthop. 2009;33:1567–1570.CrossRefPubMed
29.
go back to reference Lawrie CM, Noble PC, Ismaily SK, Stal D, Incavo SJ. The flexion-extension axis of the knee and its relationship to the rotational orientation of the tibial plateau. J Arthroplasty. 2011;26:53–58.e1. Lawrie CM, Noble PC, Ismaily SK, Stal D, Incavo SJ. The flexion-extension axis of the knee and its relationship to the rotational orientation of the tibial plateau. J Arthroplasty. 2011;26:53–58.e1.
30.
go back to reference Lotke PA, Ecker ML. Influence of positioning of prosthesis in total knee replacement. J Bone Joint Surg Am. 1977;59:77–79.CrossRefPubMed Lotke PA, Ecker ML. Influence of positioning of prosthesis in total knee replacement. J Bone Joint Surg Am. 1977;59:77–79.CrossRefPubMed
31.
go back to reference Matsumoto M, Baba T, Homma Y, Kobayashi H, Ochi H, Yuasa T, Behrend H, Kaneko K. Validation study of the Forgotten Joint Score-12 as a universal patient-reported outcome measure. Eur J Orthop Surg Traumatol. 2015;25:1141–1145.CrossRefPubMed Matsumoto M, Baba T, Homma Y, Kobayashi H, Ochi H, Yuasa T, Behrend H, Kaneko K. Validation study of the Forgotten Joint Score-12 as a universal patient-reported outcome measure. Eur J Orthop Surg Traumatol. 2015;25:1141–1145.CrossRefPubMed
32.
go back to reference Moran CG, Pinder IM, Lees TA, Midwinter MJ. Survivorship analysis of the uncemented porous-coated anatomic knee replacement. J Bone Joint Surg Am. 1991;73:848–857.CrossRefPubMed Moran CG, Pinder IM, Lees TA, Midwinter MJ. Survivorship analysis of the uncemented porous-coated anatomic knee replacement. J Bone Joint Surg Am. 1991;73:848–857.CrossRefPubMed
33.
go back to reference Murray DW, Fitzpatrick R, Rogers K, Pandit H, Beard DJ, Carr AJ, Dawson J. The use of the Oxford hip and knee scores. J Bone Joint Surg Br. 2007;89:1010–1014.CrossRefPubMed Murray DW, Fitzpatrick R, Rogers K, Pandit H, Beard DJ, Carr AJ, Dawson J. The use of the Oxford hip and knee scores. J Bone Joint Surg Br. 2007;89:1010–1014.CrossRefPubMed
34.
go back to reference Nam D, Nunley RM, Barrack RL. Patient dissatisfaction following total knee replacement: a growing concern? Bone Joint J. 2014;96:96–100.CrossRefPubMed Nam D, Nunley RM, Barrack RL. Patient dissatisfaction following total knee replacement: a growing concern? Bone Joint J. 2014;96:96–100.CrossRefPubMed
35.
go back to reference Nam D, Park A, Stambough JB, Johnson SR, Nunley RM, Barrack RL. The Mark Coventry Award: Custom cutting guides do not improve total knee arthroplasty clinical outcomes at 2 years followup. Clin Orthop Relat Res. 2016;474:40–46.CrossRefPubMed Nam D, Park A, Stambough JB, Johnson SR, Nunley RM, Barrack RL. The Mark Coventry Award: Custom cutting guides do not improve total knee arthroplasty clinical outcomes at 2 years followup. Clin Orthop Relat Res. 2016;474:40–46.CrossRefPubMed
36.
go back to reference Nogler M, Hozack W, Collopy D, Mayr E, Deirmengian G, Sekyra K. Alignment for total knee replacement: a comparison of kinematic axis versus mechanical axis techniques. A cadaver study. Int Orthop. 2012;36:2249–2253.CrossRefPubMed Nogler M, Hozack W, Collopy D, Mayr E, Deirmengian G, Sekyra K. Alignment for total knee replacement: a comparison of kinematic axis versus mechanical axis techniques. A cadaver study. Int Orthop. 2012;36:2249–2253.CrossRefPubMed
37.
go back to reference Parratte S, Pagnano MW, Trousdale RT, Berry DJ. Effect of postoperative mechanical axis alignment on the fifteen-year survival of modern, cemented total knee replacements. J Bone Joint Surg Am. 2010;92:2143–2149.CrossRefPubMed Parratte S, Pagnano MW, Trousdale RT, Berry DJ. Effect of postoperative mechanical axis alignment on the fifteen-year survival of modern, cemented total knee replacements. J Bone Joint Surg Am. 2010;92:2143–2149.CrossRefPubMed
38.
go back to reference Rebal BA, Babatunde OM, Lee JH, Geller JA, Patrick DA, Macaulay W. Imageless computer navigation in total knee arthroplasty provides superior short term functional outcomes: a meta-analysis. J Arthroplasty. 2014;29:938–944.CrossRefPubMed Rebal BA, Babatunde OM, Lee JH, Geller JA, Patrick DA, Macaulay W. Imageless computer navigation in total knee arthroplasty provides superior short term functional outcomes: a meta-analysis. J Arthroplasty. 2014;29:938–944.CrossRefPubMed
39.
go back to reference Ritter MA, Faris PM, Keating EM, Meding JB. Postoperative alignment of total knee replacement. Its effect on survival. Clin Orthop Relat Res. 1994;299:153–156. Ritter MA, Faris PM, Keating EM, Meding JB. Postoperative alignment of total knee replacement. Its effect on survival. Clin Orthop Relat Res. 1994;299:153–156.
40.
go back to reference Roberts TD, Clatworthy MG, Frampton CM, Young SW. Does computer assisted navigation improve functional outcomes and implant survivability after total knee arthroplasty? J Arthroplasty. 2015;30(Suppl):59–63.CrossRefPubMed Roberts TD, Clatworthy MG, Frampton CM, Young SW. Does computer assisted navigation improve functional outcomes and implant survivability after total knee arthroplasty? J Arthroplasty. 2015;30(Suppl):59–63.CrossRefPubMed
41.
go back to reference Tew M, Waugh W. Tibiofemoral alignment and the results of knee replacement. J Bone Joint Surg Br. 1985;67:551–556.PubMed Tew M, Waugh W. Tibiofemoral alignment and the results of knee replacement. J Bone Joint Surg Br. 1985;67:551–556.PubMed
42.
go back to reference Whitehouse SL, Lingard EA, Katz JN, Learmonth ID. Development and testing of a reduced WOMAC function scale. J Bone Joint Surg Br. 2003;85:706–711.PubMed Whitehouse SL, Lingard EA, Katz JN, Learmonth ID. Development and testing of a reduced WOMAC function scale. J Bone Joint Surg Br. 2003;85:706–711.PubMed
43.
go back to reference Woolson ST, Harris AHS, Wagner DW, Giori NJ. Component alignment during total knee arthroplasty with use of standard or custom instrumentation: a randomized clinical trial using computed tomography for postoperative alignment measurement. J Bone Joint Surg Am. 2014;96:366–372.CrossRefPubMed Woolson ST, Harris AHS, Wagner DW, Giori NJ. Component alignment during total knee arthroplasty with use of standard or custom instrumentation: a randomized clinical trial using computed tomography for postoperative alignment measurement. J Bone Joint Surg Am. 2014;96:366–372.CrossRefPubMed
Metadata
Title
The Chitranjan S. Ranawat Award
No Difference in 2-year Functional Outcomes Using Kinematic versus Mechanical Alignment in TKA: A Randomized Controlled Clinical Trial
Authors
Simon W. Young, FRACS
Matthew L. Walker, FRACS
Ali Bayan, FRACS
Toby Briant-Evans, FRCS
Paul Pavlou, FRCS
Bill Farrington, FRCS, FRACS
Publication date
01-01-2017
Publisher
Springer US
Published in
Clinical Orthopaedics and Related Research® / Issue 1/2017
Print ISSN: 0009-921X
Electronic ISSN: 1528-1132
DOI
https://doi.org/10.1007/s11999-016-4844-x

Other articles of this Issue 1/2017

Clinical Orthopaedics and Related Research® 1/2017 Go to the issue