Different bearing surfaces, including alumina-on-alumina, have been used to avoid osteolysis.
We prospectively followed 288 patients (319 hips) in which an alumina-on-alumina cup was used with a hydroxyapatite stem. The patients’ mean age was 52.7 (range, 14–70 years), and the minimum followup was 3 years (mean, 4.7 years; range, 3–8 years). At final followup, five cups (including one with an alumina liner fracture) and two stems underwent revision. The cumulative probability of not having a revision of one or both components for any cause was 97% (95% confidence interval, 94.7%–99.1%). No patient spontaneously reported any noises from the hip and none reported noises when specifically questioned. All patients who had not undergone revision had good clinical results, but five of these patients had radiographic cup loosening at last followup. These data suggest alumina-on-alumina prostheses had reasonable outcomes after 5 years. One acetabular component fractured from trauma. We observed no linear femoral head penetration. Continued followup will be required to determine if reduction in wear between the alumina-on-alumina bearings results in less osteolysis and loosening.
Level of Evidence: Level IV, therapeutic study. See the Guidelines for Authors for a complete description of levels of evidence.
Literature
1.
go back to reference Bal BS, Aleto TJ, Garino JP, Toni A, Hendricks KJ. Ceramic-on ceramic versus ceramic-on-polyethylene bearings in total hip arthroplasty: results of a multicenter prospective randomized study and update of modern ceramic total hip trials in the United States. Hip International. 2005;15:129–135. Bal BS, Aleto TJ, Garino JP, Toni A, Hendricks KJ. Ceramic-on ceramic versus ceramic-on-polyethylene bearings in total hip arthroplasty: results of a multicenter prospective randomized study and update of modern ceramic total hip trials in the United States. Hip International. 2005;15:129–135.
2.
go back to reference Bizot P, Hannouche D, Nizard R, Witvoet J, Sedel L. Hybrid alumina total hip arthroplasty using press-fit metal-backed socket in patients younger than 55 years. A six- to 11-year evaluation. J Bone Joint Surg Br. 2004;86:190–194.PubMedCrossRef Bizot P, Hannouche D, Nizard R, Witvoet J, Sedel L. Hybrid alumina total hip arthroplasty using press-fit metal-backed socket in patients younger than 55 years. A six- to 11-year evaluation. J Bone Joint Surg Br. 2004;86:190–194.PubMedCrossRef
3.
go back to reference Bizot P, Nizard R, Hamadouche M, Hannouche D, Sedel L. Prevention of wear and osteolysis. Alumina-on-alumina bearing. Clin Orthop Relat Res. 2001;393:85–93.PubMedCrossRef Bizot P, Nizard R, Hamadouche M, Hannouche D, Sedel L. Prevention of wear and osteolysis. Alumina-on-alumina bearing. Clin Orthop Relat Res. 2001;393:85–93.PubMedCrossRef
4.
go back to reference Bobyn JD, Toh KK, Hacking SA, Tanzer M, Krygier JJ. Tissue response to porous tantalum acetabular cups: a canine model. J Arthroplasty. 1999;14:347–354.PubMedCrossRef Bobyn JD, Toh KK, Hacking SA, Tanzer M, Krygier JJ. Tissue response to porous tantalum acetabular cups: a canine model. J Arthroplasty. 1999;14:347–354.PubMedCrossRef
5.
go back to reference Boutin P. Total hip arthroplasty using a ceramic prosthesis. The Classic. Clin Orthop Relat Res. 2000;379:3–11.PubMedCrossRef Boutin P. Total hip arthroplasty using a ceramic prosthesis. The Classic. Clin Orthop Relat Res. 2000;379:3–11.PubMedCrossRef
6.
go back to reference Capello WN, D’Antonio JA, Manley MT, Feinberg JR. Hydroxyapatite in total hip arthroplasty. Clinical results and critical issues. Clin Orthop Relat Res. 1998;355:200–211.PubMedCrossRef Capello WN, D’Antonio JA, Manley MT, Feinberg JR. Hydroxyapatite in total hip arthroplasty. Clinical results and critical issues. Clin Orthop Relat Res. 1998;355:200–211.PubMedCrossRef
7.
go back to reference D’Antonio J, Capello W, Manley M, Bierbaum B. New experience with alumina-on-alumina ceramic bearings for total hip arthroplasty. J Arthroplasty. 2002;17:390–397.PubMedCrossRef D’Antonio J, Capello W, Manley M, Bierbaum B. New experience with alumina-on-alumina ceramic bearings for total hip arthroplasty. J Arthroplasty. 2002;17:390–397.PubMedCrossRef
8.
go back to reference DeLee JG, Charnley J. Radiological demarcation of cemented sockets in total hip replacement. Clin Orthop Relat Res. 1976;121:20–32.PubMed DeLee JG, Charnley J. Radiological demarcation of cemented sockets in total hip replacement. Clin Orthop Relat Res. 1976;121:20–32.PubMed
9.
go back to reference Devane PA, Horne JG, Martin K, Coldham G, Krause B. Three-dimensional polyethylene wear of a press-fit titanium prosthesis. Factors influencing generation of polyethylene debris. J Arthroplasty. 1997;12:256–266.PubMedCrossRef Devane PA, Horne JG, Martin K, Coldham G, Krause B. Three-dimensional polyethylene wear of a press-fit titanium prosthesis. Factors influencing generation of polyethylene debris. J Arthroplasty. 1997;12:256–266.PubMedCrossRef
10.
go back to reference Dorr LD, Faugere M-C, Mackel AM, Gruen TA, Bognar B, Malluche HH. Structural and cellular assessment of bone quality of proximal femur. Bone. 1993;14:231–242.PubMedCrossRef Dorr LD, Faugere M-C, Mackel AM, Gruen TA, Bognar B, Malluche HH. Structural and cellular assessment of bone quality of proximal femur. Bone. 1993;14:231–242.PubMedCrossRef
11.
go back to reference Engh CA, Bobyn JD, Glassman AH. Porous-coated hip replacement. The factors governing bone ingrowth, stress shielding and clinical results. J Bone Joint Surg Br. 1987;69:45–55.PubMed Engh CA, Bobyn JD, Glassman AH. Porous-coated hip replacement. The factors governing bone ingrowth, stress shielding and clinical results. J Bone Joint Surg Br. 1987;69:45–55.PubMed
12.
go back to reference Engh CA, Glassman AH, Suthers KE. The case for porous-coated hip implants. The femoral side. Clin Orthop Relat Res. 1990;261:63–81.PubMed Engh CA, Glassman AH, Suthers KE. The case for porous-coated hip implants. The femoral side. Clin Orthop Relat Res. 1990;261:63–81.PubMed
13.
go back to reference Garcia-Cimbrelo E, Cruz-Pardos A, Cordero J, Sánchez-Sotelo J. Low-friction arthroplasty in patients younger than 40 years. 20- to 25-year results. J Arthroplasty. 2000;15:825–832.PubMedCrossRef Garcia-Cimbrelo E, Cruz-Pardos A, Cordero J, Sánchez-Sotelo J. Low-friction arthroplasty in patients younger than 40 years. 20- to 25-year results. J Arthroplasty. 2000;15:825–832.PubMedCrossRef
14.
go back to reference García-Cimbrelo E, Martínez-Sayanes JM, Minuesa A, Munuera L. Mittelmeier ceramic-ceramic prosthesis after ten years. J Arthroplasty. 1996;11:773–781.PubMedCrossRef García-Cimbrelo E, Martínez-Sayanes JM, Minuesa A, Munuera L. Mittelmeier ceramic-ceramic prosthesis after ten years. J Arthroplasty. 1996;11:773–781.PubMedCrossRef
15.
go back to reference Garino J. Modern ceramic-on-ceramic total hip systems in the United States. Clin Orthop Relat Res. 2000;379:41–47.PubMedCrossRef Garino J. Modern ceramic-on-ceramic total hip systems in the United States. Clin Orthop Relat Res. 2000;379:41–47.PubMedCrossRef
16.
go back to reference Geesink RG, Hoefnagels NHM. Six-year results of hydroxyapatite-coated total hip replacement. J Bone Joint Surg Br. 1995;77:534–547.PubMed Geesink RG, Hoefnagels NHM. Six-year results of hydroxyapatite-coated total hip replacement. J Bone Joint Surg Br. 1995;77:534–547.PubMed
17.
go back to reference Goetz DD, Smith JJ, Harris WH. The prevalence of femoral osteolysis associated with components inserted with or without cement in total hip replacements. J Bone Joint Surg Am. 1994;76:1121–1128.PubMed Goetz DD, Smith JJ, Harris WH. The prevalence of femoral osteolysis associated with components inserted with or without cement in total hip replacements. J Bone Joint Surg Am. 1994;76:1121–1128.PubMed
18.
go back to reference Gruen TA, McNeice GM, Amstutz HC. ‘Modes of failure’ of cemented stem-type femoral components: a radiographic analysis of loosening. Clin Orthop Relat Res. 1979;141:17–27.PubMed Gruen TA, McNeice GM, Amstutz HC. ‘Modes of failure’ of cemented stem-type femoral components: a radiographic analysis of loosening. Clin Orthop Relat Res. 1979;141:17–27.PubMed
19.
go back to reference Hamadouche M, Boutin P, Daussange J, Bolander ME, Sedel L. Alumina-on-alumina total hip arthroplasty. A minimum 18.5-year follow-up study. J Bone Joint Surg Am. 2002;84:69–77.PubMed Hamadouche M, Boutin P, Daussange J, Bolander ME, Sedel L. Alumina-on-alumina total hip arthroplasty. A minimum 18.5-year follow-up study. J Bone Joint Surg Am. 2002;84:69–77.PubMed
20.
go back to reference Hannouche D, Nich C, Bizot P, Meunier A, Nizard R, Sedel L. Fractures of ceramic bearings. History and present status. Clin Orthop Relat Res. 2003;417:19–26.PubMed Hannouche D, Nich C, Bizot P, Meunier A, Nizard R, Sedel L. Fractures of ceramic bearings. History and present status. Clin Orthop Relat Res. 2003;417:19–26.PubMed
21.
go back to reference Huo MH, Martin RP, Zatorsky LE, Keggi KJ. Cementless total hip arthroplasties using ceramic-on-ceramic articulation in young patients: a minimum 5-year follow-up study. J Arthroplasty. 1996;11:673–678.PubMedCrossRef Huo MH, Martin RP, Zatorsky LE, Keggi KJ. Cementless total hip arthroplasties using ceramic-on-ceramic articulation in young patients: a minimum 5-year follow-up study. J Arthroplasty. 1996;11:673–678.PubMedCrossRef
22.
go back to reference Johnston RC, Fitzgerald RH, Harris WH, Poss R, Müller ME, Sledge CB. Clinical and radiographic evaluation of total hip arthroplasty. A standard system of terminology for reporting results. J Bone Joint Surg Am. 1990;72:161–168.PubMed Johnston RC, Fitzgerald RH, Harris WH, Poss R, Müller ME, Sledge CB. Clinical and radiographic evaluation of total hip arthroplasty. A standard system of terminology for reporting results. J Bone Joint Surg Am. 1990;72:161–168.PubMed
23.
go back to reference Kaplan EL, Meier P. Nonparametric estimation from incomplete observations. J Am Stat Assoc. 1958;53:457–481.CrossRef Kaplan EL, Meier P. Nonparametric estimation from incomplete observations. J Am Stat Assoc. 1958;53:457–481.CrossRef
24.
go back to reference Kim Y-H, Kim J-S, Cho S-H. A comparison of polyethylene wear in hips with cobalt-chrome or zirconia heads. A prospective, randomised study. J Bone Joint Surg Br. 2001;83:742–750.PubMedCrossRef Kim Y-H, Kim J-S, Cho S-H. A comparison of polyethylene wear in hips with cobalt-chrome or zirconia heads. A prospective, randomised study. J Bone Joint Surg Br. 2001;83:742–750.PubMedCrossRef
25.
go back to reference Lai K-A, Shen W-J, Chen C-H, Yang C-Y, Hu W-P, Chang G-L. Failure of hydroxyapatite-coated acetabular cups. Ten-year follow-up of a 85 Landos Atoll arthroplasties. J Bone Joint Surg Br. 2002;84:641–646.PubMedCrossRef Lai K-A, Shen W-J, Chen C-H, Yang C-Y, Hu W-P, Chang G-L. Failure of hydroxyapatite-coated acetabular cups. Ten-year follow-up of a 85 Landos Atoll arthroplasties. J Bone Joint Surg Br. 2002;84:641–646.PubMedCrossRef
26.
go back to reference Merle D’Aubigné R, Postel M. Functional results of hip arthroplasty with acrylic prosthesis. J Bone Joint Surg Am. 1954;36:451–475. Merle D’Aubigné R, Postel M. Functional results of hip arthroplasty with acrylic prosthesis. J Bone Joint Surg Am. 1954;36:451–475.
27.
go back to reference Moore MS, McAuley JP, Young AM, Engh CA Sr. Radiographic signs of osseointegration in porous-coated acetabular components. Clin Orthop Relat Res. 2006;444:176–183.PubMedCrossRef Moore MS, McAuley JP, Young AM, Engh CA Sr. Radiographic signs of osseointegration in porous-coated acetabular components. Clin Orthop Relat Res. 2006;444:176–183.PubMedCrossRef
28.
go back to reference Park Y-S, Hwang S-K, Choy W-S, Kim Y-S, Moon Y-W, Lim S-J. Ceramic failure after total hip arthroplasty with an alumina-on-alumina bearing. J Bone Joint Surg Am. 2006;88:780–787.PubMedCrossRef Park Y-S, Hwang S-K, Choy W-S, Kim Y-S, Moon Y-W, Lim S-J. Ceramic failure after total hip arthroplasty with an alumina-on-alumina bearing. J Bone Joint Surg Am. 2006;88:780–787.PubMedCrossRef
29.
go back to reference Poggie RA, Turgeon TR, Coutts RD. Failure analysis of a ceramic bearing acetabular component. J Bone Joint Surg Am. 2007;89:367–380.PubMedCrossRef Poggie RA, Turgeon TR, Coutts RD. Failure analysis of a ceramic bearing acetabular component. J Bone Joint Surg Am. 2007;89:367–380.PubMedCrossRef
30.
go back to reference Riska EB. Ceramic endoprosthesis in total hip arthroplasty. Clin Orthop Relat Res. 1993;297:87–94.PubMed Riska EB. Ceramic endoprosthesis in total hip arthroplasty. Clin Orthop Relat Res. 1993;297:87–94.PubMed
31.
go back to reference Sedel L. Evolution of alumina-on-alumina implants. A review. Clin Orthop Relat Res. 2000;379:48–54.PubMedCrossRef Sedel L. Evolution of alumina-on-alumina implants. A review. Clin Orthop Relat Res. 2000;379:48–54.PubMedCrossRef
32.
go back to reference Sedel L, Kerboull L, Christel P. Alumina on alumina hip replacement results and survivorship in young patients. J Bone Joint Surg Br. 1990;72:658–663.PubMed Sedel L, Kerboull L, Christel P. Alumina on alumina hip replacement results and survivorship in young patients. J Bone Joint Surg Br. 1990;72:658–663.PubMed
33.
go back to reference Sedel L, Nizard RS, Kerboull L, Witwoet J. Alumina-alumina hip replacement in patients younger than 50 years old. Clin Orthop Relat Res. 1994;298:175–183.PubMed Sedel L, Nizard RS, Kerboull L, Witwoet J. Alumina-alumina hip replacement in patients younger than 50 years old. Clin Orthop Relat Res. 1994;298:175–183.PubMed
34.
go back to reference Soballe K. Hydroxyapatite ceramic coating for bone implant fixation. Acta Orthop Scand. 1993;255(Suppl):1–58. Soballe K. Hydroxyapatite ceramic coating for bone implant fixation. Acta Orthop Scand. 1993;255(Suppl):1–58.
35.
go back to reference Toni A, Traina F, Stea S, Sudanese A, Visentin M, Bordini B, Squarzoni S. Early diagnosis of ceramic liner fracture. Guidelines based on a twelve-year clinical experience. J Bone Joint Surg Am. 2006;88(Suppl 4):55–63.PubMedCrossRef Toni A, Traina F, Stea S, Sudanese A, Visentin M, Bordini B, Squarzoni S. Early diagnosis of ceramic liner fracture. Guidelines based on a twelve-year clinical experience. J Bone Joint Surg Am. 2006;88(Suppl 4):55–63.PubMedCrossRef
36.
go back to reference Walter WL, O’Toole GC, Walter WK, Ellis A, Zicat BA. Squeaking in ceramic-on-ceramic hips. The importance of acetabular component orientation. J Arthroplasty. 2007;22:496–503.PubMedCrossRef Walter WL, O’Toole GC, Walter WK, Ellis A, Zicat BA. Squeaking in ceramic-on-ceramic hips. The importance of acetabular component orientation. J Arthroplasty. 2007;22:496–503.PubMedCrossRef
Metadata
Title
Alumina-on-Alumina in THA
A Multicenter Prospective Study
Authors
Eduardo Garcia-Cimbrelo, MD, PhD
Eduardo Garcia-Rey, MD, PhD, EBOT
Antonio Murcia-Mazón, MD, PhD
Agustín Blanco-Pozo, MD, PhD
Eduardo Martí, MD
Publication date
01-02-2008
Publisher
Springer-Verlag
Published in
Clinical Orthopaedics and Related Research® / Issue 2/2008
Print ISSN: 0009-921X
Electronic ISSN: 1528-1132
DOI
https://doi.org/10.1007/s11999-007-0042-1

Other articles of this Issue 2/2008

Clinical Orthopaedics and Related Research® 2/2008 Go to the issue

Symposium: Papers Presented at the Closed Meeting of the International Hip Society

Long-term Radiographic Assessment of Cemented Polyethylene Acetabular Cups

International Hip Society Symposium

Retroacetabular Stress-shielding in THA