Abstract

Purpose of Review

Wearable cardioverter defibrillators (WCDs) have been developed as a temporary measure for protecting patients at risk for sudden cardiac death that do not meet the indication for implantable cardioverter defibrillator (ICD), most notably in the early stages of heart failure with reduced ejection fraction before reassessment of their left ventricular ejection fraction. In this review, we report available evidence in the literature and guidelines regarding WCD use in order to try to define the role WCDs may have in heart failure.

Recent Findings

In the last decade, most observational studies found WCDs to be both safe and effective in terminating ventricular arrhythmias in various indications, mostly centered around heart failure with reduced ejection fraction. The only available randomized controlled trial using WCD did not however show a benefit on patients’ survival. Hence, recent guidelines only recommended its use in limited indications. Recent data also suggest a possible interest of WCD in monitoring patients, a finding that may prove useful in the context of new-onset heart failure.

Summary

Data regarding WCD benefit is scarce, and definitive conclusions on its utility are hard to draw. In the context of heart failure, and particularly new-onset heart failure, WCD might find a role in a global comprehensive management of the disease, both acting as an educational tool, a monitoring tool, and, most importantly, a safe and effective tool in preventing sudden cardiac death. The low level of evidence however invites caution, and the decision of prescribing a WCD needs to be individualized and thoroughly discussed with the patient whose compliance is key with this device.
Literature
1.
go back to reference Moss AJ, Hall WJ, Cannom DS, Daubert JP, Higgins SL, Klein H, Levine JH, Saksena S, Waldo AL, Wilber D, Brown MW, Heo M. Improved survival with an implanted defibrillator in patients with coronary disease at high risk for ventricular arrhythmia. Multicenter Automatic Defibrillator Implantation Trial Investigators. N Engl J Med. 1996;335(26):1933–40. https://doi.org/10.1056/NEJM199612263352601.CrossRefPubMed Moss AJ, Hall WJ, Cannom DS, Daubert JP, Higgins SL, Klein H, Levine JH, Saksena S, Waldo AL, Wilber D, Brown MW, Heo M. Improved survival with an implanted defibrillator in patients with coronary disease at high risk for ventricular arrhythmia. Multicenter Automatic Defibrillator Implantation Trial Investigators. N Engl J Med. 1996;335(26):1933–40. https://​doi.​org/​10.​1056/​NEJM199612263352​601.CrossRefPubMed
2.
go back to reference Moss AJ, Zareba W, Hall WJ, Klein H, Wilber DJ, Cannom DS, Daubert JP, Higgins SL, Brown MW, Andrews ML; Multicenter Automatic Defibrillator Implantation Trial II Investigators. Prophylactic implantation of a defibrillator in patients with myocardial infarction and reduced ejection fraction. N Engl J Med. 2002;346(12):877–83. https://doi.org/10.1056/NEJMoa013474. Moss AJ, Zareba W, Hall WJ, Klein H, Wilber DJ, Cannom DS, Daubert JP, Higgins SL, Brown MW, Andrews ML; Multicenter Automatic Defibrillator Implantation Trial II Investigators. Prophylactic implantation of a defibrillator in patients with myocardial infarction and reduced ejection fraction. N Engl J Med. 2002;346(12):877–83. https://​doi.​org/​10.​1056/​NEJMoa013474.
3.
go back to reference Bardy GH, Lee KL, Mark DB, Poole JE, Packer DL, Boineau R, Domanski M, Troutman C, Anderson J, Johnson G, McNulty SE, Clapp-Channing N, Davidson-Ray LD, Fraulo ES, Fishbein DP, Luceri RM, Ip JH; Sudden Cardiac Death in Heart Failure Trial (SCD-HeFT) Investigators. Amiodarone or an implantable cardioverter-defibrillator for congestive heart failure. N Engl J Med. 2005;352(3):225–37. https://doi.org/10.1056/NEJMoa043399. Bardy GH, Lee KL, Mark DB, Poole JE, Packer DL, Boineau R, Domanski M, Troutman C, Anderson J, Johnson G, McNulty SE, Clapp-Channing N, Davidson-Ray LD, Fraulo ES, Fishbein DP, Luceri RM, Ip JH; Sudden Cardiac Death in Heart Failure Trial (SCD-HeFT) Investigators. Amiodarone or an implantable cardioverter-defibrillator for congestive heart failure. N Engl J Med. 2005;352(3):225–37. https://​doi.​org/​10.​1056/​NEJMoa043399.
4.
go back to reference Connolly SJ, Hallstrom AP, Cappato R, Schron EB, Kuck KH, Zipes DP, Greene HL, Boczor S, Domanski M, Follmann D, Gent M, Roberts RS. Meta-analysis of the implantable cardioverter defibrillator secondary prevention trials AVID, CASH and CIDS studies. Antiarrhythmics vs implantable defibrillator study. Cardiac Arrest Study Hamburg. Canadian Implantable Defibrillator Study. Eur Heart J. 2000;21(24):2071–8. https://doi.org/10.1053/euhj.2000.2476.CrossRefPubMed Connolly SJ, Hallstrom AP, Cappato R, Schron EB, Kuck KH, Zipes DP, Greene HL, Boczor S, Domanski M, Follmann D, Gent M, Roberts RS. Meta-analysis of the implantable cardioverter defibrillator secondary prevention trials AVID, CASH and CIDS studies. Antiarrhythmics vs implantable defibrillator study. Cardiac Arrest Study Hamburg. Canadian Implantable Defibrillator Study. Eur Heart J. 2000;21(24):2071–8. https://​doi.​org/​10.​1053/​euhj.​2000.​2476.CrossRefPubMed
5.
go back to reference Al-Khatib SM, Stevenson WG, Ackerman MJ, Bryant WJ, Callans DJ, Curtis AB, Deal BJ, Dickfeld T, Field ME, Fonarow GC, Gillis AM, Granger CB, Hammill SC, Hlatky MA, Joglar JA, Kay GN, Matlock DD, Myerburg RJ, Page RL. 2017 AHA/ACC/HRS guideline for management of patients with ventricular arrhythmias and the prevention of sudden cardiac death: a report of the American College of Cardiology/American Heart Association Task Force on Clinical Practice Guidelines and the Heart Rhythm Society. J Am Coll Cardiol. 2018;72(14):e91–220. https://doi.org/10.1016/j.jacc.2017.10.054.CrossRefPubMed Al-Khatib SM, Stevenson WG, Ackerman MJ, Bryant WJ, Callans DJ, Curtis AB, Deal BJ, Dickfeld T, Field ME, Fonarow GC, Gillis AM, Granger CB, Hammill SC, Hlatky MA, Joglar JA, Kay GN, Matlock DD, Myerburg RJ, Page RL. 2017 AHA/ACC/HRS guideline for management of patients with ventricular arrhythmias and the prevention of sudden cardiac death: a report of the American College of Cardiology/American Heart Association Task Force on Clinical Practice Guidelines and the Heart Rhythm Society. J Am Coll Cardiol. 2018;72(14):e91–220. https://​doi.​org/​10.​1016/​j.​jacc.​2017.​10.​054.CrossRefPubMed
6.
go back to reference McDonagh TA, Metra M, Adamo M, Gardner RS, Baumbach A, Böhm M, Burri H, Butler J, Čelutkienė J, Chioncel O, Cleland JGF, Coats AJS, Crespo-Leiro MG, Farmakis D, Gilard M, Heymans S, Hoes AW, Jaarsma T, Jankowska EA, Lainscak M, Lam CSP, Lyon AR, McMurray JJV, Mebazaa A, Mindham R, Muneretto C, Francesco Piepoli M, Price S, Rosano GMC, Ruschitzka F, Kathrine Skibelund A; ESC Scientific Document Group. 2021 ESC Guidelines for the diagnosis and treatment of acute and chronic heart failure. Eur Heart J. 2021;42(36):3599–3726. https://doi.org/10.1093/eurheartj/ehab368. McDonagh TA, Metra M, Adamo M, Gardner RS, Baumbach A, Böhm M, Burri H, Butler J, Čelutkienė J, Chioncel O, Cleland JGF, Coats AJS, Crespo-Leiro MG, Farmakis D, Gilard M, Heymans S, Hoes AW, Jaarsma T, Jankowska EA, Lainscak M, Lam CSP, Lyon AR, McMurray JJV, Mebazaa A, Mindham R, Muneretto C, Francesco Piepoli M, Price S, Rosano GMC, Ruschitzka F, Kathrine Skibelund A; ESC Scientific Document Group. 2021 ESC Guidelines for the diagnosis and treatment of acute and chronic heart failure. Eur Heart J. 2021;42(36):3599–3726. https://​doi.​org/​10.​1093/​eurheartj/​ehab368.
7.
go back to reference Solomon SD, Zelenkofske S, McMurray JJ, Finn PV, Velazquez E, Ertl G, Harsanyi A, Rouleau JL, Maggioni A, Kober L, White H, Van de Werf F, Pieper K, Califf RM, Pfeffer MA; Valsartan in Acute Myocardial Infarction Trial (VALIANT) Investigators. Sudden death in patients with myocardial infarction and left ventricular dysfunction, heart failure, or both. N Engl J Med. 2005;352(25):2581–8. https://doi.org/10.1056/NEJMoa043938. Solomon SD, Zelenkofske S, McMurray JJ, Finn PV, Velazquez E, Ertl G, Harsanyi A, Rouleau JL, Maggioni A, Kober L, White H, Van de Werf F, Pieper K, Califf RM, Pfeffer MA; Valsartan in Acute Myocardial Infarction Trial (VALIANT) Investigators. Sudden death in patients with myocardial infarction and left ventricular dysfunction, heart failure, or both. N Engl J Med. 2005;352(25):2581–8. https://​doi.​org/​10.​1056/​NEJMoa043938.
10.
go back to reference •• Epstein AE, Abraham WT, Bianco NR, Kern KB, Mirro M, Rao SV, Rhee EK, Solomon SD, Szymkiewicz SJ. Wearable cardioverter-defibrillator use in patients perceived to be at high risk early post-myocardial infarction. J Am Coll Cardiol. 2013;62(21):2000–7. https://doi.org/10.1016/j.jacc.2013.05.086. (The largest prospective registry of WCD use in ICM patients with LVEF ≤ 35%.)CrossRefPubMed •• Epstein AE, Abraham WT, Bianco NR, Kern KB, Mirro M, Rao SV, Rhee EK, Solomon SD, Szymkiewicz SJ. Wearable cardioverter-defibrillator use in patients perceived to be at high risk early post-myocardial infarction. J Am Coll Cardiol. 2013;62(21):2000–7. https://​doi.​org/​10.​1016/​j.​jacc.​2013.​05.​086. (The largest prospective registry of WCD use in ICM patients with LVEF ≤ 35%.)CrossRefPubMed
14.
go back to reference Tanja Odeneg and others. on behalf of the Austrian WCD Study Group, Indications for and outcome in patients with the wearable cardioverter-defibrillator in a nurse-based training programme: results of the Austrian WCD Registry. Eur J Cardiovasc Nurs. 2019;18(1):75–83. https://doi.org/10.1177/1474515118790365.CrossRef Tanja Odeneg and others. on behalf of the Austrian WCD Study Group, Indications for and outcome in patients with the wearable cardioverter-defibrillator in a nurse-based training programme: results of the Austrian WCD Registry. Eur J Cardiovasc Nurs. 2019;18(1):75–83. https://​doi.​org/​10.​1177/​1474515118790365​.CrossRef
15.
go back to reference Garcia R, Combes N, Defaye P, Narayanan K, Guedon-Moreau L, Boveda S, Blangy H, Bouet J, Briand F, Chevalier P, Cottin Y, Da Costa A, Degand B, Deharo JC, Eschalier R, Extramiana F, Goralski M, Guy-Moyat B, Guyomar Y, Hermida JS, Jourda F, Lellouche N, Mahfoud M, Manenti V, Mansourati J, Martin A, Pasquié JL, Ritter P, Rollin A, Tibi T, Yalioua A, Gras D, Sadoul N, Piot O, Leclercq C, Marijon E. Wearable cardioverter-defibrillator in patients with a transient risk of sudden cardiac death: the WEARIT-France cohort study. Europace. 2021;23(1):73–81. https://doi.org/10.1093/europace/euaa268.CrossRefPubMed Garcia R, Combes N, Defaye P, Narayanan K, Guedon-Moreau L, Boveda S, Blangy H, Bouet J, Briand F, Chevalier P, Cottin Y, Da Costa A, Degand B, Deharo JC, Eschalier R, Extramiana F, Goralski M, Guy-Moyat B, Guyomar Y, Hermida JS, Jourda F, Lellouche N, Mahfoud M, Manenti V, Mansourati J, Martin A, Pasquié JL, Ritter P, Rollin A, Tibi T, Yalioua A, Gras D, Sadoul N, Piot O, Leclercq C, Marijon E. Wearable cardioverter-defibrillator in patients with a transient risk of sudden cardiac death: the WEARIT-France cohort study. Europace. 2021;23(1):73–81. https://​doi.​org/​10.​1093/​europace/​euaa268.CrossRefPubMed
17.
go back to reference Mueller-Leisse J, Brunn J, Zormpas C, Hohmann S, Hillmann HAK, Eiringhaus J, Bauersachs J, Veltmann C, Duncker D. Delayed improvement of left ventricular function in newly diagnosed heart failure depends on etiology-a PROLONG-II substudy. Sensors (Basel). 2022;22(5):2037. https://doi.org/10.3390/s22052037.CrossRefPubMed Mueller-Leisse J, Brunn J, Zormpas C, Hohmann S, Hillmann HAK, Eiringhaus J, Bauersachs J, Veltmann C, Duncker D. Delayed improvement of left ventricular function in newly diagnosed heart failure depends on etiology-a PROLONG-II substudy. Sensors (Basel). 2022;22(5):2037. https://​doi.​org/​10.​3390/​s22052037.CrossRefPubMed
20.
go back to reference •Kuehn C, Ruemke S, Rellecke P, Lichtenberg A, Joskowiak D, Hagl C, Hassan M, Leyh RG, Erler S, Garbade J, Eifert S, Grieshaber P, Boening A, Doenst T, Velichkov I, Madej T, Knaut M, Hain A, Burger H. Wearable cardioverter defibrillator multicentre experience in a large cardiac surgery cohort at transient risk of sudden cardiac death. Eur J Cardiothorac Surg. 2022;61(5):1031–1040. https://doi.org/10.1093/ejcts/ezac086. (Use of WCD in a large multicenter retrospective cardiac surgery cohort.) •Kuehn C, Ruemke S, Rellecke P, Lichtenberg A, Joskowiak D, Hagl C, Hassan M, Leyh RG, Erler S, Garbade J, Eifert S, Grieshaber P, Boening A, Doenst T, Velichkov I, Madej T, Knaut M, Hain A, Burger H. Wearable cardioverter defibrillator multicentre experience in a large cardiac surgery cohort at transient risk of sudden cardiac death. Eur J Cardiothorac Surg. 2022;61(5):1031–1040. https://​doi.​org/​10.​1093/​ejcts/​ezac086. (Use of WCD in a large multicenter retrospective cardiac surgery cohort.)
21.
go back to reference Lackermair K, Schuhmann CG, Kubieniec M, Riesinger LM, Klier I, Stocker TJ, Kääb S, Estner HL, Fichtner S. Impairment of quality of life among patients with wearable cardioverter defibrillator therapy (LifeVest®): a preliminary study. Biomed Res Int. 2018;27(2018):6028494. https://doi.org/10.1155/2018/6028494.CrossRef Lackermair K, Schuhmann CG, Kubieniec M, Riesinger LM, Klier I, Stocker TJ, Kääb S, Estner HL, Fichtner S. Impairment of quality of life among patients with wearable cardioverter defibrillator therapy (LifeVest®): a preliminary study. Biomed Res Int. 2018;27(2018):6028494. https://​doi.​org/​10.​1155/​2018/​6028494.CrossRef
23.
go back to reference Kellnar A, Fichtner S, Sams L, Stremmel C, Estner HL, Lackermair K. Evaluation of a standardized training and adherence surveillance programme to overcome quality-of-life impairments and enhance compliance in patients treated with wearable cardioverter defibrillator. Patient prefer adherence. N Engl J Med. 2023;17:433–40. https://doi.org/10.2147/PPA.S400086.CrossRef Kellnar A, Fichtner S, Sams L, Stremmel C, Estner HL, Lackermair K. Evaluation of a standardized training and adherence surveillance programme to overcome quality-of-life impairments and enhance compliance in patients treated with wearable cardioverter defibrillator. Patient prefer adherence. N Engl J Med. 2023;17:433–40. https://​doi.​org/​10.​2147/​PPA.​S400086.CrossRef
24.
go back to reference Shen L, Jhund PS, Petrie MC, Claggett BL, Barlera S, Cleland JGF, Dargie HJ, Granger CB, Kjekshus J, Køber L, Latini R, Maggioni AP, Packer M, Pitt B, Solomon SD, Swedberg K, Tavazzi L, Wikstrand J, Zannad F, Zile MR, McMurray JJV. Declining risk of sudden death in heart failure. N Engl J Med. 2017;377(1):41–51. https://doi.org/10.1056/NEJMoa1609758.CrossRefPubMed Shen L, Jhund PS, Petrie MC, Claggett BL, Barlera S, Cleland JGF, Dargie HJ, Granger CB, Kjekshus J, Køber L, Latini R, Maggioni AP, Packer M, Pitt B, Solomon SD, Swedberg K, Tavazzi L, Wikstrand J, Zannad F, Zile MR, McMurray JJV. Declining risk of sudden death in heart failure. N Engl J Med. 2017;377(1):41–51. https://​doi.​org/​10.​1056/​NEJMoa1609758.CrossRefPubMed
26.
go back to reference • Berger JM, Sengupta JD, Bank AJ, Casey SA, Witt D, Sharkey SW, Stanberry LI, Hauser RG. Causes and clinical consequences of inappropriate shocks experienced by patients wearing a cardioverter-defibrillator. Heart Rhythm. 2023;20(7):970–975. https://doi.org/10.1016/j.hrthm.2023.03.1604. (Analysis of a registry of inappropriate shocks by the LifeVest® in 2021–2022 reported to FDA.) • Berger JM, Sengupta JD, Bank AJ, Casey SA, Witt D, Sharkey SW, Stanberry LI, Hauser RG. Causes and clinical consequences of inappropriate shocks experienced by patients wearing a cardioverter-defibrillator. Heart Rhythm. 2023;20(7):970–975. https://​doi.​org/​10.​1016/​j.​hrthm.​2023.​03.​1604. (Analysis of a registry of inappropriate shocks by the LifeVest® in 2021–2022 reported to FDA.)
28.
go back to reference Poole JE, Gleva MJ, Birgersdotter-Green U, Branch KRH, Doshi RN, Salam T, Crawford TC, Willcox ME, Sridhar AM, Mikdadi G, Beinart SC, Cha YM, Russo AM, Rowbotham RK, Sullivan J, Gustavson LM, Kivilaid K. A wearable cardioverter defibrillator with a low false alarm rate. J Cardiovasc Electrophysiol. 2022;33(5):831–42. https://doi.org/10.1111/jce.15417.CrossRefPubMedPubMedCentral Poole JE, Gleva MJ, Birgersdotter-Green U, Branch KRH, Doshi RN, Salam T, Crawford TC, Willcox ME, Sridhar AM, Mikdadi G, Beinart SC, Cha YM, Russo AM, Rowbotham RK, Sullivan J, Gustavson LM, Kivilaid K. A wearable cardioverter defibrillator with a low false alarm rate. J Cardiovasc Electrophysiol. 2022;33(5):831–42. https://​doi.​org/​10.​1111/​jce.​15417.CrossRefPubMedPubMedCentral
29.
go back to reference •• Olgin JE, Pletcher MJ, Vittinghoff E, Wranicz J, Malik R, Morin DP, Zweibel S, Buxton AE, Elayi CS, Chung EH, Rashba E, Borggrefe M, Hue TF, Maguire C, Lin F, Simon JA, Hulley S, Lee BK; VEST Investigators. Wearable cardioverter-defibrillator after myocardial infarction. N Engl J Med. 2018;379(13):1205–1215. https://doi.org/10.1056/NEJMoa1800781. (The only randomized controlled trial evaluating the benefit of WCD use.) •• Olgin JE, Pletcher MJ, Vittinghoff E, Wranicz J, Malik R, Morin DP, Zweibel S, Buxton AE, Elayi CS, Chung EH, Rashba E, Borggrefe M, Hue TF, Maguire C, Lin F, Simon JA, Hulley S, Lee BK; VEST Investigators. Wearable cardioverter-defibrillator after myocardial infarction. N Engl J Med. 2018;379(13):1205–1215. https://​doi.​org/​10.​1056/​NEJMoa1800781. (The only randomized controlled trial evaluating the benefit of WCD use.)
30.
go back to reference • Olgin JE, Lee BK, Vittinghoff E, Morin DP, Zweibel S, Rashba E, Chung EH, Borggrefe M, Hulley S, Lin F, Hue TF, Pletcher MJ. Impact of wearable cardioverter-defibrillator compliance on outcomes in the VEST trial: as-treated and per-protocol analyses. J Cardiovasc Electrophysiol. 2020;31(5):1009–1018. https://doi.org/10.1111/jce.14404. (As treated and per protocol analyses of VEST trial.) • Olgin JE, Lee BK, Vittinghoff E, Morin DP, Zweibel S, Rashba E, Chung EH, Borggrefe M, Hulley S, Lin F, Hue TF, Pletcher MJ. Impact of wearable cardioverter-defibrillator compliance on outcomes in the VEST trial: as-treated and per-protocol analyses. J Cardiovasc Electrophysiol. 2020;31(5):1009–1018. https://​doi.​org/​10.​1111/​jce.​14404. (As treated and per protocol analyses of VEST trial.)
32.
go back to reference •• Masri A, Altibi AM, Erqou S, Zmaili MA, Saleh A, Al-Adham R, Ayoub K, Baghal M, Alkukhun L, Barakat AF, Jain S, Saba S, Adelstein E. Wearable cardioverter-defibrillator therapy for the prevention of sudden cardiac death: a systematic review and meta-analysis. JACC Clin Electrophysiol. 2019;5(2):152–161. https://doi.org/10.1016/j.jacep.2018.11.011. (Meta-analysis of the main studies on WCD, including the VEST trial.) •• Masri A, Altibi AM, Erqou S, Zmaili MA, Saleh A, Al-Adham R, Ayoub K, Baghal M, Alkukhun L, Barakat AF, Jain S, Saba S, Adelstein E. Wearable cardioverter-defibrillator therapy for the prevention of sudden cardiac death: a systematic review and meta-analysis. JACC Clin Electrophysiol. 2019;5(2):152–161. https://​doi.​org/​10.​1016/​j.​jacep.​2018.​11.​011. (Meta-analysis of the main studies on WCD, including the VEST trial.)
33.
go back to reference Duncker D, Westenfeld R, Konrad T, Pfeffer T, Correia de Freitas CA, Pfister R, Thomas D, Fürnkranz A, Andrié RP, Napp A, Schmitt J, Karolyi L, Wakili R, Hilfiker-Kleiner D, Bauersachs J, Veltmann C. Risk for life-threatening arrhythmia in newly diagnosed peripartum cardiomyopathy with low ejection fraction: a German multi-centre analysis. Clin Res Cardiol. 2017;106(8):582–589. https://doi.org/10.1007/s00392-017-1090-5. Duncker D, Westenfeld R, Konrad T, Pfeffer T, Correia de Freitas CA, Pfister R, Thomas D, Fürnkranz A, Andrié RP, Napp A, Schmitt J, Karolyi L, Wakili R, Hilfiker-Kleiner D, Bauersachs J, Veltmann C. Risk for life-threatening arrhythmia in newly diagnosed peripartum cardiomyopathy with low ejection fraction: a German multi-centre analysis. Clin Res Cardiol. 2017;106(8):582–589. https://​doi.​org/​10.​1007/​s00392-017-1090-5.
34.
go back to reference Zeppenfeld K, Tfelt-Hansen J, de Riva M, Winkel BG, Behr ER, Blom NA, Charron P, Corrado D, Dagres N, de Chillou C, Eckardt L, Friede T, Haugaa KH, Hocini M, Lambiase PD, Marijon E, Merino JL, Peichl P, Priori SG, Reichlin T, Schulz-Menger J, Sticherling C, Tzeis S, Verstrael A, Volterrani M; ESC Scientific Document Group. 2022 ESC Guidelines for the management of patients with ventricular arrhythmias and the prevention of sudden cardiac death. Eur Heart J. 2022;43(40):3997–4126. https://doi.org/10.1093/eurheartj/ehac262. Zeppenfeld K, Tfelt-Hansen J, de Riva M, Winkel BG, Behr ER, Blom NA, Charron P, Corrado D, Dagres N, de Chillou C, Eckardt L, Friede T, Haugaa KH, Hocini M, Lambiase PD, Marijon E, Merino JL, Peichl P, Priori SG, Reichlin T, Schulz-Menger J, Sticherling C, Tzeis S, Verstrael A, Volterrani M; ESC Scientific Document Group. 2022 ESC Guidelines for the management of patients with ventricular arrhythmias and the prevention of sudden cardiac death. Eur Heart J. 2022;43(40):3997–4126. https://​doi.​org/​10.​1093/​eurheartj/​ehac262.
35.
36.
go back to reference Hillmann HAK, Hohmann S, Mueller-Leisse J, Zormpas C, Eiringhaus J, Bauersachs J, Veltmann C, Duncker D. Feasibility and first results of heart failure monitoring using the wearable cardioverter-defibrillator in newly diagnosed heart failure with reduced ejection fraction. Sensors (Basel). 2021;21(23):7798. https://doi.org/10.3390/s21237798.CrossRefPubMed Hillmann HAK, Hohmann S, Mueller-Leisse J, Zormpas C, Eiringhaus J, Bauersachs J, Veltmann C, Duncker D. Feasibility and first results of heart failure monitoring using the wearable cardioverter-defibrillator in newly diagnosed heart failure with reduced ejection fraction. Sensors (Basel). 2021;21(23):7798. https://​doi.​org/​10.​3390/​s21237798.CrossRefPubMed
37.
go back to reference Garcia R, Warming PE, Narayanan K, Defaye P, Guedon-Moreau L, Blangy H, Piot O, Leclercq C, Marijon E; WEARIT-France Investigators. Dynamic changes in nocturnal heart rate predict short-term cardiovascular events in patients using the wearable cardioverter-defibrillator: from the WEARIT-France cohort study. Europace. 2023;25(5):euad062. https://doi.org/10.1093/europace/euad062. Garcia R, Warming PE, Narayanan K, Defaye P, Guedon-Moreau L, Blangy H, Piot O, Leclercq C, Marijon E; WEARIT-France Investigators. Dynamic changes in nocturnal heart rate predict short-term cardiovascular events in patients using the wearable cardioverter-defibrillator: from the WEARIT-France cohort study. Europace. 2023;25(5):euad062. https://​doi.​org/​10.​1093/​europace/​euad062.
38.
go back to reference Botto GL, Mantovani LG, Cortesi PA, De Ponti R, D'Onofrio A, Biffi M, Capucci A, Casu G, Notarstefano P, Scaglione M, Zanotto G, Boriani G; Italian Association of Arrhythmology and Cardiac Pacing (AIAC). The value of wearable cardioverter defibrillator in adult patients with recent myocardial infarction: economic and clinical implications from a health technology assessment perspective. Int J Cardiol. 2022;356:12–18. https://doi.org/10.1016/j.ijcard.2022.04.003 Botto GL, Mantovani LG, Cortesi PA, De Ponti R, D'Onofrio A, Biffi M, Capucci A, Casu G, Notarstefano P, Scaglione M, Zanotto G, Boriani G; Italian Association of Arrhythmology and Cardiac Pacing (AIAC). The value of wearable cardioverter defibrillator in adult patients with recent myocardial infarction: economic and clinical implications from a health technology assessment perspective. Int J Cardiol. 2022;356:12–18. https://​doi.​org/​10.​1016/​j.​ijcard.​2022.​04.​003
Metadata
Title
The Role of the Wearable Defibrillator in Heart Failure
Authors
Thibault Lenormand
Alexandre Bodin
Laurent Fauchier
Publication date
18-01-2024
Publisher
Springer US
Published in
Current Heart Failure Reports / Issue 1/2024
Print ISSN: 1546-9530
Electronic ISSN: 1546-9549
DOI
https://doi.org/10.1007/s11897-023-00641-x

Other articles of this Issue 1/2024

Current Heart Failure Reports 1/2024 Go to the issue