Skip to main content
Top
Published in: Journal of Children's Orthopaedics 1/2016

Open Access 01-02-2016 | Current Concept Review

EOS® biplanar X-ray imaging: concept, developments, benefits, and limitations

Authors: Elias Melhem, Ayman Assi, Rami El Rachkidi, Ismat Ghanem

Published in: Journal of Children's Orthopaedics | Issue 1/2016

Login to get access

Abstract

Purpose

In 1992, Georges Charpak invented a new type of X-ray detector, which in turn led to the development of the EOS® 2D/3D imaging system. This system takes simultaneous anteroposterior and lateral 2D images of the whole body and can be utilized to perform 3D reconstruction based on statistical models. The purpose of this review is to present the state of the art for this EOS® imaging technique, to report recent developments and advances in the technique, and to stress its benefits while also noting its limitations.

Methods

The review was based on a thorough literature search on the subject as well as personal experience gained from many years of using the EOS® system.

Results

While EOS® imaging could be proposed for many applications, it is most useful in relation to scoliosis and sagittal balance, due to its ability to take simultaneous orthogonal images while the patient is standing, to perform 3D reconstruction, and to determine various relationships among adjacent segments (cervical spine, pelvis, and lower limbs). The technique has also been validated for the study of pelvic and lower-limb deformity and pathology in adult and pediatric populations; in such a study it has the advantage of allowing the measurement of torsional deformity, which classically requires a CT scan.

Conclusions

The major advantages of EOS® are the relatively low dose of radiation (50–80 % less than conventional X-rays) that the patient receives and the possibility of obtaining a 3D reconstruction of the bones. However, this 3D reconstruction is not created automatically; a well-trained operator is required to generate it. The EOS® imaging technique has proven itself to be a very useful research and diagnostic tool.
Literature
1.
go back to reference Charpak G (1981) La detection des particules. Recherche 128:1384–1396 Charpak G (1981) La detection des particules. Recherche 128:1384–1396
2.
go back to reference Dubousset J, Charpak G, Dorion I et al (2005) A new 2D and 3D imaging approach to musculoskeletal physiology and pathology with low-dose radiation and the standing position: the EOS system. Bull Acad Natl Med 189:287–297 (Discussion 297–300) PubMed Dubousset J, Charpak G, Dorion I et al (2005) A new 2D and 3D imaging approach to musculoskeletal physiology and pathology with low-dose radiation and the standing position: the EOS system. Bull Acad Natl Med 189:287–297 (Discussion 297–300) PubMed
4.
go back to reference Chaibi Y, Cresson T, Aubert B et al (2012) Fast 3D reconstruction of the lower limb using a parametric model and statistical inferences and clinical measurements calculation from biplanar X-rays. Comput Methods Biomech Biomed Eng 15:457–466. doi:10.1080/10255842.2010.540758 CrossRef Chaibi Y, Cresson T, Aubert B et al (2012) Fast 3D reconstruction of the lower limb using a parametric model and statistical inferences and clinical measurements calculation from biplanar X-rays. Comput Methods Biomech Biomed Eng 15:457–466. doi:10.​1080/​10255842.​2010.​540758 CrossRef
5.
go back to reference Kalifa G, Charpak Y, Maccia C et al (1998) Evaluation of a new low-dose digital X-ray device: first dosimetric and clinical results in children. Pediatr Radiol 28:557–561CrossRefPubMed Kalifa G, Charpak Y, Maccia C et al (1998) Evaluation of a new low-dose digital X-ray device: first dosimetric and clinical results in children. Pediatr Radiol 28:557–561CrossRefPubMed
6.
7.
go back to reference Ilharreborde B, Ferrero E, Alison M, Mazda K (2015) EOS microdose protocol for the radiological follow-up of adolescent idiopathic scoliosis. Eur Spine J. doi:10.1007/s00586-015-3960-8 Ilharreborde B, Ferrero E, Alison M, Mazda K (2015) EOS microdose protocol for the radiological follow-up of adolescent idiopathic scoliosis. Eur Spine J. doi:10.​1007/​s00586-015-3960-8
8.
9.
go back to reference Krug KB, Weber C, Schwabe H et al (2014) Comparison of image quality using a X-ray stereotactical whole-body system and a direct flat-panel X-ray device in examinations of the pelvis and knee. RoFo Fortschritte auf dem Gebiet der Rontgenstrahlen und der Bildgeb Verfahren 186:67–76. doi:10.1055/s-0033-1350441 Krug KB, Weber C, Schwabe H et al (2014) Comparison of image quality using a X-ray stereotactical whole-body system and a direct flat-panel X-ray device in examinations of the pelvis and knee. RoFo Fortschritte auf dem Gebiet der Rontgenstrahlen und der Bildgeb Verfahren 186:67–76. doi:10.​1055/​s-0033-1350441
10.
go back to reference Rousseau M-A, Laporte S, Chavary-Bernier E et al (2007) Reproducibility of measuring the shape and three-dimensional position of cervical vertebrae in upright position using the EOS stereoradiography system. Spine (Phila Pa 1976) 32:2569–2572. doi:10.1097/BRS.0b013e318158cba2 CrossRef Rousseau M-A, Laporte S, Chavary-Bernier E et al (2007) Reproducibility of measuring the shape and three-dimensional position of cervical vertebrae in upright position using the EOS stereoradiography system. Spine (Phila Pa 1976) 32:2569–2572. doi:10.​1097/​BRS.​0b013e318158cba2​ CrossRef
12.
go back to reference Deschênes S, Godbout B, Skalli W, de Guise J (2002) Semi-automation of the 3D reconstruction of the spine using wavelets and splines. Stud Health Technol Inform 91:276–280PubMed Deschênes S, Godbout B, Skalli W, de Guise J (2002) Semi-automation of the 3D reconstruction of the spine using wavelets and splines. Stud Health Technol Inform 91:276–280PubMed
14.
go back to reference Cresson T, Chav R, Branchaud D et al (2009) Coupling 2D/3D registration method and statistical model to perform 3D reconstruction from partial X-rays images data. Conf Proc IEEE Eng Med Biol Soc 2009:1008–1011. doi:10.1109/IEMBS.2009.5333869 PubMed Cresson T, Chav R, Branchaud D et al (2009) Coupling 2D/3D registration method and statistical model to perform 3D reconstruction from partial X-rays images data. Conf Proc IEEE Eng Med Biol Soc 2009:1008–1011. doi:10.​1109/​IEMBS.​2009.​5333869 PubMed
17.
go back to reference Somoskeöy S, Tunyogi-Csapó M, Bogyó C, Illés T (2012) Accuracy and reliability of coronal and sagittal spinal curvature data based on patient-specific three-dimensional models created by the EOS 2D/3D imaging system. Spine J 12:1052–1059. doi:10.1016/j.spinee.2012.10.002 CrossRefPubMed Somoskeöy S, Tunyogi-Csapó M, Bogyó C, Illés T (2012) Accuracy and reliability of coronal and sagittal spinal curvature data based on patient-specific three-dimensional models created by the EOS 2D/3D imaging system. Spine J 12:1052–1059. doi:10.​1016/​j.​spinee.​2012.​10.​002 CrossRefPubMed
20.
go back to reference Ilharreborde B, Steffen JS, Nectoux E et al (2011) Angle measurement reproducibility using EOS three-dimensional reconstructions in adolescent idiopathic scoliosis treated by posterior instrumentation. Spine (Phila Pa 1976) 36:E1306–E1313. doi:10.1097/BRS.0b013e3182293548 CrossRef Ilharreborde B, Steffen JS, Nectoux E et al (2011) Angle measurement reproducibility using EOS three-dimensional reconstructions in adolescent idiopathic scoliosis treated by posterior instrumentation. Spine (Phila Pa 1976) 36:E1306–E1313. doi:10.​1097/​BRS.​0b013e3182293548​ CrossRef
22.
25.
go back to reference Ilharreborde B, Dubousset J, Le Huec J-C (2014) Use of EOS imaging for the assessment of scoliosis deformities: application to postoperative 3D quantitative analysis of the trunk. Eur Spine J 23(Suppl 4):S397–S405. doi:10.1007/s00586-014-3334-7 PubMed Ilharreborde B, Dubousset J, Le Huec J-C (2014) Use of EOS imaging for the assessment of scoliosis deformities: application to postoperative 3D quantitative analysis of the trunk. Eur Spine J 23(Suppl 4):S397–S405. doi:10.​1007/​s00586-014-3334-7 PubMed
28.
go back to reference Hirsch C, Ilharreborde B, Mazda K (2015) EOS suspension test for the assessment of spinal flexibility in adolescent idiopathic scoliosis. Eur Spine J 24:1408–1414. doi:10.1007/s00586-015-3771-y Hirsch C, Ilharreborde B, Mazda K (2015) EOS suspension test for the assessment of spinal flexibility in adolescent idiopathic scoliosis. Eur Spine J 24:1408–1414. doi:10.​1007/​s00586-015-3771-y
31.
33.
go back to reference Lazennec JY, Brusson A, Folinais D et al (2015) Measuring extension of the lumbar–pelvic–femoral complex with the EOS® system. Eur J Orthop Surg Traumatol 25:1061–1068. doi:10.1007/s00590-015-1603-8 Lazennec JY, Brusson A, Folinais D et al (2015) Measuring extension of the lumbar–pelvic–femoral complex with the EOS® system. Eur J Orthop Surg Traumatol 25:1061–1068. doi:10.​1007/​s00590-015-1603-8
34.
go back to reference Rillardon L, Campana S, Mitton D et al (2005) Evaluation of the intervertebral disc spaces with a low dose radiographic system. J Radiol 86:311–319CrossRefPubMed Rillardon L, Campana S, Mitton D et al (2005) Evaluation of the intervertebral disc spaces with a low dose radiographic system. J Radiol 86:311–319CrossRefPubMed
35.
go back to reference Sapin E, Briot K, Kolta S et al (2008) Bone mineral density assessment using the EOS low-dose X-ray device: a feasibility study. Proc Inst Mech Eng H 222:1263–1271CrossRefPubMed Sapin E, Briot K, Kolta S et al (2008) Bone mineral density assessment using the EOS low-dose X-ray device: a feasibility study. Proc Inst Mech Eng H 222:1263–1271CrossRefPubMed
36.
go back to reference Sapin-de Brosses E, Jolivet E, Travert C et al (2012) Prediction of the vertebral strength using a finite element model derived from low-dose biplanar imaging: benefits of subject-specific material properties. Spine (Phila Pa 1976) 37:E156–E162. doi:10.1097/BRS.0b013e3182293628 CrossRef Sapin-de Brosses E, Jolivet E, Travert C et al (2012) Prediction of the vertebral strength using a finite element model derived from low-dose biplanar imaging: benefits of subject-specific material properties. Spine (Phila Pa 1976) 37:E156–E162. doi:10.​1097/​BRS.​0b013e3182293628​ CrossRef
38.
go back to reference Bittersohl B, Freitas J, Zaps D et al (2013) EOS imaging of the human pelvis: reliability, validity, and controlled comparison with radiography. J Bone Joint Surg Am 95:e581–e589. doi:10.2106/JBJS.K.01591 CrossRef Bittersohl B, Freitas J, Zaps D et al (2013) EOS imaging of the human pelvis: reliability, validity, and controlled comparison with radiography. J Bone Joint Surg Am 95:e581–e589. doi:10.​2106/​JBJS.​K.​01591 CrossRef
39.
go back to reference Rousseau M-A, Brusson A, Lazennec J-Y (2014) Assessment of the axial rotation of the pelvis with the EOS(®) imaging system: intra- and inter-observer reproducibility and accuracy study. Eur J Orthop Surg Traumatol 24:891–895. doi:10.1007/s00590-013-1281-3 CrossRefPubMed Rousseau M-A, Brusson A, Lazennec J-Y (2014) Assessment of the axial rotation of the pelvis with the EOS(®) imaging system: intra- and inter-observer reproducibility and accuracy study. Eur J Orthop Surg Traumatol 24:891–895. doi:10.​1007/​s00590-013-1281-3 CrossRefPubMed
40.
go back to reference Baudoin A, Skalli W, de Guise JA, Mitton D (2008) Parametric subject-specific model for in vivo 3D reconstruction using bi-planar X-rays: application to the upper femoral extremity. Med Biol Eng Comput 46:799–805. doi:10.1007/s11517-008-0353-8 CrossRefPubMed Baudoin A, Skalli W, de Guise JA, Mitton D (2008) Parametric subject-specific model for in vivo 3D reconstruction using bi-planar X-rays: application to the upper femoral extremity. Med Biol Eng Comput 46:799–805. doi:10.​1007/​s11517-008-0353-8 CrossRefPubMed
41.
go back to reference Humbert L, Carlioz H, Baudoin A et al (2008) 3D evaluation of the acetabular coverage assessed by biplanar X-rays or single anteroposterior X-ray compared with CT-scan. Comput Methods Biomech Biomed Eng 11:257–262. doi:10.1080/10255840701760423 Humbert L, Carlioz H, Baudoin A et al (2008) 3D evaluation of the acetabular coverage assessed by biplanar X-rays or single anteroposterior X-ray compared with CT-scan. Comput Methods Biomech Biomed Eng 11:257–262. doi:10.​1080/​1025584070176042​3
42.
go back to reference Assi A, Ghostine B, Sauret C, et al. (2015) Validity and reliability of adult pelvic 3D reconstructions using low dose biplanar X-rays. In: ISB 2015, Glasgow, UK, 12–16 July 2015 Assi A, Ghostine B, Sauret C, et al. (2015) Validity and reliability of adult pelvic 3D reconstructions using low dose biplanar X-rays. In: ISB 2015, Glasgow, UK, 12–16 July 2015
45.
go back to reference Escott BG, Ravi B, Weathermon AC et al (2013) EOS low-dose radiography: a reliable and accurate upright assessment of lower-limb lengths. J Bone Jt Surg 95(e183):1. doi:10.2106/JBJS.L.00989 Escott BG, Ravi B, Weathermon AC et al (2013) EOS low-dose radiography: a reliable and accurate upright assessment of lower-limb lengths. J Bone Jt Surg 95(e183):1. doi:10.​2106/​JBJS.​L.​00989
47.
go back to reference Pomerantz ML, Glaser D, Doan J et al (2014) Three-dimensional biplanar radiography as a new means of accessing femoral version: a comparitive study of EOS three-dimensional radiography versus computed tomography. Skeletal Radiol 44:255–260. doi:10.1007/s00256-014-2031-2 CrossRefPubMed Pomerantz ML, Glaser D, Doan J et al (2014) Three-dimensional biplanar radiography as a new means of accessing femoral version: a comparitive study of EOS three-dimensional radiography versus computed tomography. Skeletal Radiol 44:255–260. doi:10.​1007/​s00256-014-2031-2 CrossRefPubMed
48.
go back to reference Rungprai C, Goetz JE, Arunakul M et al (2014) Validation and reproducibility of a biplanar imaging system versus conventional radiography of foot and ankle radiographic parameters. Foot Ankle Int 35:1166–1175. doi:10.1177/1071100714545514 CrossRefPubMed Rungprai C, Goetz JE, Arunakul M et al (2014) Validation and reproducibility of a biplanar imaging system versus conventional radiography of foot and ankle radiographic parameters. Foot Ankle Int 35:1166–1175. doi:10.​1177/​1071100714545514​ CrossRefPubMed
52.
go back to reference Lazennec JY, Rousseau MA, Rangel A et al (2011) Pelvis and total hip arthroplasty acetabular component orientations in sitting and standing positions: measurements reproductibility with EOS imaging system versus conventional radiographies. Orthop Traumatol Surg Res 97:373–380. doi:10.1016/j.otsr.2011.02.006 CrossRefPubMed Lazennec JY, Rousseau MA, Rangel A et al (2011) Pelvis and total hip arthroplasty acetabular component orientations in sitting and standing positions: measurements reproductibility with EOS imaging system versus conventional radiographies. Orthop Traumatol Surg Res 97:373–380. doi:10.​1016/​j.​otsr.​2011.​02.​006 CrossRefPubMed
55.
go back to reference Lazennec JY, Brusson A, Dominique F et al (2015) Offset and anteversion reconstruction after cemented and uncemented total hip arthroplasty: an evaluation with the low-dose EOS system comparing two- and three-dimensional imaging. Int Orthop 39:1259–1267. doi:10.1007/s00264-014-2616-3 Lazennec JY, Brusson A, Dominique F et al (2015) Offset and anteversion reconstruction after cemented and uncemented total hip arthroplasty: an evaluation with the low-dose EOS system comparing two- and three-dimensional imaging. Int Orthop 39:1259–1267. doi:10.​1007/​s00264-014-2616-3
56.
57.
go back to reference Lazennec J, Rousseau M, Brusson A et al (2015) Total hip prostheses in standing, sitting and squatting positions: an overview of our 8 years practice using the EOS imaging technology. Open Orthop J 9:26–44PubMedCentralCrossRefPubMed Lazennec J, Rousseau M, Brusson A et al (2015) Total hip prostheses in standing, sitting and squatting positions: an overview of our 8 years practice using the EOS imaging technology. Open Orthop J 9:26–44PubMedCentralCrossRefPubMed
58.
go back to reference Barbier O, Skalli W, Mainard L, Mainard D (2014) The reliability of the anterior pelvic plane for computer navigated acetabular component placement during total hip arthroplasty: prospective study with the EOS imaging system. Orthop Traumatol Surg Res 100:S287–S291. doi:10.1016/j.otsr.2014.07.003 CrossRefPubMed Barbier O, Skalli W, Mainard L, Mainard D (2014) The reliability of the anterior pelvic plane for computer navigated acetabular component placement during total hip arthroplasty: prospective study with the EOS imaging system. Orthop Traumatol Surg Res 100:S287–S291. doi:10.​1016/​j.​otsr.​2014.​07.​003 CrossRefPubMed
59.
go back to reference Billaud A, Verdier N, de Bartolo R et al (2015) Acetabular component navigation in lateral decubitus based on EOS imaging: a preliminary study of 13 cases. Orthop Traumatol Surg Res 101:271–275. doi:10.1016/j.otsr.2015.01.010 Billaud A, Verdier N, de Bartolo R et al (2015) Acetabular component navigation in lateral decubitus based on EOS imaging: a preliminary study of 13 cases. Orthop Traumatol Surg Res 101:271–275. doi:10.​1016/​j.​otsr.​2015.​01.​010
65.
69.
71.
go back to reference Dietrich TJ, Pfirrmann CWA, Schwab A et al (2013) Comparison of radiation dose, workflow, patient comfort and financial break-even of standard digital radiography and a novel biplanar low-dose X-ray system for upright full-length lower limb and whole spine radiography. Skeletal Radiol 42:959–967. doi:10.1007/s00256-013-1600-0 CrossRefPubMed Dietrich TJ, Pfirrmann CWA, Schwab A et al (2013) Comparison of radiation dose, workflow, patient comfort and financial break-even of standard digital radiography and a novel biplanar low-dose X-ray system for upright full-length lower limb and whole spine radiography. Skeletal Radiol 42:959–967. doi:10.​1007/​s00256-013-1600-0 CrossRefPubMed
72.
go back to reference McKenna C, Wade R, Faria R et al (2012) EOS 2D/3D X-ray imaging system: a systematic review and economic evaluation. Health Technol Assess 16:1–188. doi:10.3310/hta16140 CrossRef McKenna C, Wade R, Faria R et al (2012) EOS 2D/3D X-ray imaging system: a systematic review and economic evaluation. Health Technol Assess 16:1–188. doi:10.​3310/​hta16140 CrossRef
Metadata
Title
EOS® biplanar X-ray imaging: concept, developments, benefits, and limitations
Authors
Elias Melhem
Ayman Assi
Rami El Rachkidi
Ismat Ghanem
Publication date
01-02-2016
Publisher
Springer Berlin Heidelberg
Published in
Journal of Children's Orthopaedics / Issue 1/2016
Print ISSN: 1863-2521
Electronic ISSN: 1863-2548
DOI
https://doi.org/10.1007/s11832-016-0713-0

Other articles of this Issue 1/2016

Journal of Children's Orthopaedics 1/2016 Go to the issue