Skip to main content
Top
Published in: Strategies in Trauma and Limb Reconstruction 3/2017

Open Access 01-11-2017 | Review

Repair of the pronator quadratus after volar plate fixation in distal radius fractures: a systematic review

Authors: Marjolein A.M. Mulders, Monique M.J. Walenkamp, Fernande J.M.E. Bos, Niels W.L. Schep, J. Carel Goslings

Published in: Strategies in Trauma and Limb Reconstruction | Issue 3/2017

Login to get access

Abstract

To position the volar plate on the distal radius fracture site, the pronator quadratus muscle needs to be detached from its distal and radial side and lifted for optimal exposure to the fracture site. Although the conventional approach involves repair of the pronator quadratus, controversy surrounds the merits of this repair. The purpose of this study was to compare the functional outcomes of patients with distal radius fractures treated with pronator quadratus repair after volar plate fixation versus no pronator quadratus repair. A systematic search was conducted in Medline, EMBASE and the Cochrane Central Register of Controlled Trials, on 23 July 2015. All studies comparing pronator quadratus repair with no pronator quadratus repair in adult patients undergoing volar plate fixation for distal radius fractures were included. The primary outcome was the Disability of the Arm, Shoulder and Hand (DASH) score at 12 months. Secondary outcomes included range of motion, grip strength, post-operative pain and complications. A total of 169 patients were included, of which 95 underwent pronator quadratus repair, while 74 patients underwent no pronator quadratus repair. At 12 months follow-up no statistically significant differences in DASH-scores and range of motion were observed between pronator quadratus repair and no repair. Moreover, post-operative pain and complication rates were similar between both groups. At 12 months of follow-up, we do not see any advantages of pronator quadratus repair after volar plate fixation in the distal radius. However, a definitive conclusion cannot be drawn from this systematic review due to a lack of available evidence.
Literature
1.
go back to reference Chung KC, Spilson SV (2001) The frequency and epidemiology of hand and forearm fractures in the United States. J Hand Surg Am 26(5):908–915CrossRefPubMed Chung KC, Spilson SV (2001) The frequency and epidemiology of hand and forearm fractures in the United States. J Hand Surg Am 26(5):908–915CrossRefPubMed
2.
go back to reference Ismail AA, Pye SR, Cockerill WC et al (2002) Incidence of limb fracture across Europe: results from the European prospective osteoporosis study (EPOS). Osteoporos Int 13(7):565–571CrossRefPubMed Ismail AA, Pye SR, Cockerill WC et al (2002) Incidence of limb fracture across Europe: results from the European prospective osteoporosis study (EPOS). Osteoporos Int 13(7):565–571CrossRefPubMed
3.
go back to reference Bentohami A, Bosma J, Akkersdijk GJM, van Dijkman B, Goslings JC, Schep NWL (2014) Incidence and characteristics of distal radial fractures in an urban population in The Netherlands. Eur J Trauma Emerg Surg 40(3):357–361PubMed Bentohami A, Bosma J, Akkersdijk GJM, van Dijkman B, Goslings JC, Schep NWL (2014) Incidence and characteristics of distal radial fractures in an urban population in The Netherlands. Eur J Trauma Emerg Surg 40(3):357–361PubMed
4.
go back to reference Chung KC, Shauver MJ, Birkmeyer JD (2009) Trends in the United States in the treatment of distal radial fractures in the elderly. J Bone Joint Surg Am 91(8):1868–1873CrossRefPubMedPubMedCentral Chung KC, Shauver MJ, Birkmeyer JD (2009) Trends in the United States in the treatment of distal radial fractures in the elderly. J Bone Joint Surg Am 91(8):1868–1873CrossRefPubMedPubMedCentral
5.
go back to reference Fanuele J, Koval KJ, Lurie J, Zhou W, Tosteson A, Ring D (2009) Distal radial fracture treatment: what you get may depend on your age and address. J Bone Joint Surg Am 91(6):1313–1319CrossRefPubMedPubMedCentral Fanuele J, Koval KJ, Lurie J, Zhou W, Tosteson A, Ring D (2009) Distal radial fracture treatment: what you get may depend on your age and address. J Bone Joint Surg Am 91(6):1313–1319CrossRefPubMedPubMedCentral
6.
go back to reference Mattila VM, Huttunen TT, Sillanpaa P, Niemi S, Pihlajamaki H, Kannus P (2011) Significant change in the surgical treatment of distal radius fractures: a nationwide study between 1998 and 2008 in Finland. J Trauma 71(4):939–942 (discussion 942–933) CrossRefPubMed Mattila VM, Huttunen TT, Sillanpaa P, Niemi S, Pihlajamaki H, Kannus P (2011) Significant change in the surgical treatment of distal radius fractures: a nationwide study between 1998 and 2008 in Finland. J Trauma 71(4):939–942 (discussion 942–933) CrossRefPubMed
7.
go back to reference Mellstrand-Navarro C, Pettersson HJ, Tornqvist H, Ponzer S (2014) The operative treatment of fractures of the distal radius is increasing: results from a nationwide Swedish study. Bone Joint J 96-b(7):963–969CrossRefPubMed Mellstrand-Navarro C, Pettersson HJ, Tornqvist H, Ponzer S (2014) The operative treatment of fractures of the distal radius is increasing: results from a nationwide Swedish study. Bone Joint J 96-b(7):963–969CrossRefPubMed
8.
go back to reference Wright TW, Horodyski M, Smith DW (2005) Functional outcome of unstable distal radius fractures: ORIF with a volar fixed-angle tine plate versus external fixation. J Hand Surg Am 30(2):289–299CrossRefPubMed Wright TW, Horodyski M, Smith DW (2005) Functional outcome of unstable distal radius fractures: ORIF with a volar fixed-angle tine plate versus external fixation. J Hand Surg Am 30(2):289–299CrossRefPubMed
9.
go back to reference Williksen JH, Husby T, Hellund JC, Kvernmo HD, Rosales C, Frihagen F (2015) External fixation and adjuvant pins versus volar locking plate fixation in unstable distal radius fractures: a randomized, controlled study with a 5-year follow-up. J Hand Surg Am 40(7):1333–1340CrossRefPubMed Williksen JH, Husby T, Hellund JC, Kvernmo HD, Rosales C, Frihagen F (2015) External fixation and adjuvant pins versus volar locking plate fixation in unstable distal radius fractures: a randomized, controlled study with a 5-year follow-up. J Hand Surg Am 40(7):1333–1340CrossRefPubMed
10.
11.
go back to reference Protopsaltis TS, Ruch DS (2008) Volar approach to distal radius fractures. J Hand Surg Am 33(6):958–965CrossRefPubMed Protopsaltis TS, Ruch DS (2008) Volar approach to distal radius fractures. J Hand Surg Am 33(6):958–965CrossRefPubMed
12.
go back to reference Orbay J, Badia A, Khoury RK, Gonzalez E, Indriago I (2004) Volar fixed-angle fixation of distal radius fractures: the DVR plate. Tech Hand Up Extrem Surg 8(3):142–148CrossRefPubMed Orbay J, Badia A, Khoury RK, Gonzalez E, Indriago I (2004) Volar fixed-angle fixation of distal radius fractures: the DVR plate. Tech Hand Up Extrem Surg 8(3):142–148CrossRefPubMed
13.
go back to reference Orbay JL (2000) The treatment of unstable distal radius fractures with volar fixation. Hand Surg 5(2):103–112CrossRefPubMed Orbay JL (2000) The treatment of unstable distal radius fractures with volar fixation. Hand Surg 5(2):103–112CrossRefPubMed
14.
go back to reference Schneppendahl J, Windolf J, Kaufmann RA (2012) Distal radius fractures: current concepts. J Hand Surg Am 37(8):1718–1725CrossRefPubMed Schneppendahl J, Windolf J, Kaufmann RA (2012) Distal radius fractures: current concepts. J Hand Surg Am 37(8):1718–1725CrossRefPubMed
15.
go back to reference Chirpaz-Cerbat JM, Ruatti S, Houillon C, Ionescu S (2011) Dorsally displaced distal radius fractures treated by fixed-angle volar plating: grip and pronosupination strength recovery. A prospective study. Orthop Traumatol Surg Res 97(5):465–470CrossRefPubMed Chirpaz-Cerbat JM, Ruatti S, Houillon C, Ionescu S (2011) Dorsally displaced distal radius fractures treated by fixed-angle volar plating: grip and pronosupination strength recovery. A prospective study. Orthop Traumatol Surg Res 97(5):465–470CrossRefPubMed
16.
go back to reference Tosti R, Ilyas AM (2013) Prospective evaluation of pronator quadratus repair following volar plate fixation of distal radius fractures. J Hand Surg 38(9):1678–1684CrossRef Tosti R, Ilyas AM (2013) Prospective evaluation of pronator quadratus repair following volar plate fixation of distal radius fractures. J Hand Surg 38(9):1678–1684CrossRef
17.
go back to reference Berglund LM, Messer TM (2009) Complications of volar plate fixation for managing distal radius fractures. J Am Acad Orthop Surg 17(6):369–377CrossRefPubMed Berglund LM, Messer TM (2009) Complications of volar plate fixation for managing distal radius fractures. J Am Acad Orthop Surg 17(6):369–377CrossRefPubMed
18.
go back to reference Swigart CR, Badon MA, Bruegel VL, Dodds SD (2012) Assessment of pronator quadratus repair integrity following volar plate fixation for distal radius fractures: a prospective clinical cohort study. J Hand Surg Am 37(9):1868–1873CrossRefPubMed Swigart CR, Badon MA, Bruegel VL, Dodds SD (2012) Assessment of pronator quadratus repair integrity following volar plate fixation for distal radius fractures: a prospective clinical cohort study. J Hand Surg Am 37(9):1868–1873CrossRefPubMed
19.
go back to reference Hershman SH, Immerman I, Bechtel C, Lekic N, Paksima N, Egol KA (2013) The effects of pronator quadratus repair on outcomes after volar plating of distal radius fractures. J Orthop Trauma 27(3):130–133CrossRefPubMed Hershman SH, Immerman I, Bechtel C, Lekic N, Paksima N, Egol KA (2013) The effects of pronator quadratus repair on outcomes after volar plating of distal radius fractures. J Orthop Trauma 27(3):130–133CrossRefPubMed
20.
go back to reference Ahsan ZS, Yao J (2012) The importance of pronator quadratus repair in the treatment of distal radius fractures with volar plating. Hand (N Y) 7(3):276–280CrossRef Ahsan ZS, Yao J (2012) The importance of pronator quadratus repair in the treatment of distal radius fractures with volar plating. Hand (N Y) 7(3):276–280CrossRef
21.
go back to reference Moher D, Liberati A, Tetzlaff J, Altman DG (2009) Preferred reporting items for systematic reviews and meta-analyses: the PRISMA statement. J Clin Epidemiol 62(10):1006–1012CrossRefPubMed Moher D, Liberati A, Tetzlaff J, Altman DG (2009) Preferred reporting items for systematic reviews and meta-analyses: the PRISMA statement. J Clin Epidemiol 62(10):1006–1012CrossRefPubMed
22.
go back to reference Gummesson C, Atroshi I, Ekdahl C (2003) The disabilities of the arm, shoulder and hand (DASH) outcome questionnaire: longitudinal construct validity and measuring self-rated health change after surgery. BMC Musculoskelet Disord 4:11CrossRefPubMedPubMedCentral Gummesson C, Atroshi I, Ekdahl C (2003) The disabilities of the arm, shoulder and hand (DASH) outcome questionnaire: longitudinal construct validity and measuring self-rated health change after surgery. BMC Musculoskelet Disord 4:11CrossRefPubMedPubMedCentral
23.
go back to reference Bentohami A, de Burlet K, de Korte N, van den Bekerom MP, Goslings JC, Schep NW (2014) Complications following volar locking plate fixation for distal radial fractures: a systematic review. J Hand Surg Eur 39(7):745–754CrossRef Bentohami A, de Burlet K, de Korte N, van den Bekerom MP, Goslings JC, Schep NW (2014) Complications following volar locking plate fixation for distal radial fractures: a systematic review. J Hand Surg Eur 39(7):745–754CrossRef
24.
go back to reference Jadad AR, Moore RA, Carroll D, Jenkinson C, Reynolds DJ, Gavaghan DJ, McQuay HJ (1996) Assessing the quality of reports of randomized clinical trials: is blinding necessary? Control Clin Trials 17(1):1–12CrossRefPubMed Jadad AR, Moore RA, Carroll D, Jenkinson C, Reynolds DJ, Gavaghan DJ, McQuay HJ (1996) Assessing the quality of reports of randomized clinical trials: is blinding necessary? Control Clin Trials 17(1):1–12CrossRefPubMed
26.
go back to reference Gordon KD, Pardo RD, Johnson JA, King GJ, Miller TA (2004) Electromyographic activity and strength during maximum isometric pronation and supination efforts in healthy adults. J Orthop Res 22(1):208–213CrossRefPubMed Gordon KD, Pardo RD, Johnson JA, King GJ, Miller TA (2004) Electromyographic activity and strength during maximum isometric pronation and supination efforts in healthy adults. J Orthop Res 22(1):208–213CrossRefPubMed
27.
go back to reference Arora R, Lutz M, Hennerbichler A, Krappinger D, Espen D, Gabl M (2007) Complications following internal fixation of unstable distal radius fracture with a palmar locking-plate. J Orthop Trauma 21(5):316–322CrossRefPubMed Arora R, Lutz M, Hennerbichler A, Krappinger D, Espen D, Gabl M (2007) Complications following internal fixation of unstable distal radius fracture with a palmar locking-plate. J Orthop Trauma 21(5):316–322CrossRefPubMed
28.
go back to reference Heidari N, Clement H, Kosuge D, Grechenig W, Tesch NP, Weinberg AM (2012) Is sparing the pronator quadratus muscle possible in volar plating of the distal radius? J Hand Surg Eur 37(5):402–406CrossRef Heidari N, Clement H, Kosuge D, Grechenig W, Tesch NP, Weinberg AM (2012) Is sparing the pronator quadratus muscle possible in volar plating of the distal radius? J Hand Surg Eur 37(5):402–406CrossRef
29.
go back to reference Brown EN, Lifchez SD (2011) Flexor pollicis longus tendon rupture after volar plating of a distal radius fracture: pronator quadratus plate coverage may not adequately protect tendons. Eplasty 11:e43PubMedPubMedCentral Brown EN, Lifchez SD (2011) Flexor pollicis longus tendon rupture after volar plating of a distal radius fracture: pronator quadratus plate coverage may not adequately protect tendons. Eplasty 11:e43PubMedPubMedCentral
30.
go back to reference Soong M, Earp BE, Bishop G, Leung A, Blazar P (2011) Volar locking plate implant prominence and flexor tendon rupture. J Bone Joint Surg Am 93(4):328–335CrossRefPubMed Soong M, Earp BE, Bishop G, Leung A, Blazar P (2011) Volar locking plate implant prominence and flexor tendon rupture. J Bone Joint Surg Am 93(4):328–335CrossRefPubMed
31.
go back to reference Cross AW, Schmidt CC (2008) Flexor tendon injuries following locked volar plating of distal radius fractures. J Hand Surg Am 33(2):164–167CrossRefPubMed Cross AW, Schmidt CC (2008) Flexor tendon injuries following locked volar plating of distal radius fractures. J Hand Surg Am 33(2):164–167CrossRefPubMed
32.
go back to reference Koebke J, Werner J, Piening H (1984) The quadrate pronator muscle–a morphological and functional analysis. Anat Anz 157(4):311–318PubMed Koebke J, Werner J, Piening H (1984) The quadrate pronator muscle–a morphological and functional analysis. Anat Anz 157(4):311–318PubMed
34.
go back to reference McConkey MO, Schwab TD, Travlos A, Oxland TR, Goetz T (2009) Quantification of pronator quadratus contribution to isometric pronation torque of the forearm. J Hand Surg Am 34(9):1612–1617CrossRefPubMed McConkey MO, Schwab TD, Travlos A, Oxland TR, Goetz T (2009) Quantification of pronator quadratus contribution to isometric pronation torque of the forearm. J Hand Surg Am 34(9):1612–1617CrossRefPubMed
35.
go back to reference Haugstvedt JR, Berger RA, Berglund LJ (2001) A mechanical study of the moment-forces of the supinators and pronators of the forearm. Acta Orthop Scand 72(6):629–634CrossRefPubMed Haugstvedt JR, Berger RA, Berglund LJ (2001) A mechanical study of the moment-forces of the supinators and pronators of the forearm. Acta Orthop Scand 72(6):629–634CrossRefPubMed
36.
go back to reference Armangil M, Bezirgan U, Basarir K, Bilen G, Demirtas M, Bilgin SS (2014) The pronator quadratus muscle after plating of distal radius fractures: is the muscle still working? Eu J Orthop Surg Traumatol 24(3):335–339CrossRef Armangil M, Bezirgan U, Basarir K, Bilen G, Demirtas M, Bilgin SS (2014) The pronator quadratus muscle after plating of distal radius fractures: is the muscle still working? Eu J Orthop Surg Traumatol 24(3):335–339CrossRef
37.
go back to reference Huh JK, Lim JY, Song CH, Baek GH, Lee YH, Gong HS (2012) Isokinetic evaluation of pronation after volar plating of a distal radius fracture. Injury 43(2):200–204CrossRefPubMed Huh JK, Lim JY, Song CH, Baek GH, Lee YH, Gong HS (2012) Isokinetic evaluation of pronation after volar plating of a distal radius fracture. Injury 43(2):200–204CrossRefPubMed
38.
go back to reference Nho JH, Gong HS, Song CH, Wi SM, Lee YH, Baek GH (2014) Examination of the pronator quadratus muscle during hardware removal procedures after volar plating for distal radius fractures. Clin Orthop Surg 6(3):267–272CrossRefPubMedPubMedCentral Nho JH, Gong HS, Song CH, Wi SM, Lee YH, Baek GH (2014) Examination of the pronator quadratus muscle during hardware removal procedures after volar plating for distal radius fractures. Clin Orthop Surg 6(3):267–272CrossRefPubMedPubMedCentral
39.
go back to reference Haberle S, Sandmann GH, Deiler S, Kraus TM, Fensky F, Torsiglieri T, Rondak IC, Biberthaler P, Stockle U, Siebenlist S (2015) Pronator quadratus repair after volar plating of distal radius fractures or not? Results of a prospective randomized trial. Eur J Med Res 20:93CrossRefPubMedPubMedCentral Haberle S, Sandmann GH, Deiler S, Kraus TM, Fensky F, Torsiglieri T, Rondak IC, Biberthaler P, Stockle U, Siebenlist S (2015) Pronator quadratus repair after volar plating of distal radius fractures or not? Results of a prospective randomized trial. Eur J Med Res 20:93CrossRefPubMedPubMedCentral
40.
go back to reference Cannon TA, Carlston CV, Stevanovic MV, Ghiassi AD (2014) Pronator-sparing technique for volar plating of distal radius fractures. J Hand Surg Am 39(12):2506–2511CrossRefPubMed Cannon TA, Carlston CV, Stevanovic MV, Ghiassi AD (2014) Pronator-sparing technique for volar plating of distal radius fractures. J Hand Surg Am 39(12):2506–2511CrossRefPubMed
41.
go back to reference Rey PB, Rochet S, Loisel F, Obert L (2014) Technical note: how to spare the pronator quadratus during MIPO of distal radius fractures by using a mini-volar plate. Chir Main 33(2):95–99CrossRefPubMed Rey PB, Rochet S, Loisel F, Obert L (2014) Technical note: how to spare the pronator quadratus during MIPO of distal radius fractures by using a mini-volar plate. Chir Main 33(2):95–99CrossRefPubMed
42.
go back to reference Zenke Y, Sakai A, Oshige T, Moritani S, Fuse Y, Maehara T, Nakamura T (2011) Clinical results of volar locking plate for distal radius fractures: conventional versus minimally invasive plate osteosynthesis. J Orthop Trauma 25(7):425–431CrossRefPubMed Zenke Y, Sakai A, Oshige T, Moritani S, Fuse Y, Maehara T, Nakamura T (2011) Clinical results of volar locking plate for distal radius fractures: conventional versus minimally invasive plate osteosynthesis. J Orthop Trauma 25(7):425–431CrossRefPubMed
43.
go back to reference Lo HY, Cheng HY (2014) Clinical study of the pronator quadratus muscle: anatomical features and feasibility of pronator-sparing surgery. BMC Musculoskelet Disord 15:136CrossRefPubMedPubMedCentral Lo HY, Cheng HY (2014) Clinical study of the pronator quadratus muscle: anatomical features and feasibility of pronator-sparing surgery. BMC Musculoskelet Disord 15:136CrossRefPubMedPubMedCentral
Metadata
Title
Repair of the pronator quadratus after volar plate fixation in distal radius fractures: a systematic review
Authors
Marjolein A.M. Mulders
Monique M.J. Walenkamp
Fernande J.M.E. Bos
Niels W.L. Schep
J. Carel Goslings
Publication date
01-11-2017
Publisher
Springer Milan
Published in
Strategies in Trauma and Limb Reconstruction / Issue 3/2017
Print ISSN: 1828-8936
Electronic ISSN: 1828-8928
DOI
https://doi.org/10.1007/s11751-017-0288-4

Other articles of this Issue 3/2017

Strategies in Trauma and Limb Reconstruction 3/2017 Go to the issue