Skip to main content
Top
Published in: BMC Musculoskeletal Disorders 1/2014

Open Access 01-12-2014 | Research article

Clinical study of the Pronator Quadratus muscle: anatomical features and feasibility of Pronator-Sparing Surgery

Authors: Hsien-Yi Lo, Hong-Yi Cheng

Published in: BMC Musculoskeletal Disorders | Issue 1/2014

Login to get access

Abstract

Background

No clinical data for the relationship of pronator quadratus (PQ) muscle to distal radius had been reported. The aim of this study was to investigate the anatomical features of the PQ muscle related to plate osteosynthesis for distal radius fractures in clinical cases. The feasibility of PQ muscle sparing surgery was investigated as well.

Methods

Fifty two distal radius fractures (23-A2) were enclosed in this study. The whole width of the muscle and the distance from the distal edge of the muscle to the joint surface of the distal radius were measured. The distance from the fracture site of the radius to the joint surface was measured as well.

Results

The average width of the pronator quadratus muscle was 37.6 mm. The average distance from the pronator quadratus muscle to the lunate fossa surface was 12.2 mm, and the average distance from the pronator quadratus muscle to the scaphoid fossa surface was 13.6 mm. The average distance from the lunate fossa of the distal radius to the fracture site was 12.2 mm (range, 7.3-17 mm), and the scaphoid fossa of the distal radius to the fracture site was 13.2 mm (range, 9.4-18.8 mm).

Conclusions

This PQ muscle sparing surgery is feasible and can be performed without difficulty. The data might provide a useful basis for the preservation of pronator quadratus muscle applied to a functionally reduced fracture regarding the potential efficacy of conventional volar plate osteosynthesis.
Appendix
Available only for authorised users
Literature
1.
go back to reference Heim U, Pfeiffer KM: Internal fixation of small fractures. 1987, Berlin: Springer, Verlag, 3 Heim U, Pfeiffer KM: Internal fixation of small fractures. 1987, Berlin: Springer, Verlag, 3
2.
go back to reference Farouk O, Krettek C, Miclau T, Schandelmaier P, Guy P, Tscheme H: Minimally invasive plate osteosynthesis: does percutaneous plating disrupt femoral blood supply less than the traditional technique?. J Orthop Trauma. 1999, 13: 401-406. 10.1097/00005131-199908000-00002.CrossRefPubMed Farouk O, Krettek C, Miclau T, Schandelmaier P, Guy P, Tscheme H: Minimally invasive plate osteosynthesis: does percutaneous plating disrupt femoral blood supply less than the traditional technique?. J Orthop Trauma. 1999, 13: 401-406. 10.1097/00005131-199908000-00002.CrossRefPubMed
3.
go back to reference Krettek C, Muller M, Miclau T: Evolution of minimally invasive plate osteosynthesis (MIPO) in the femur. Injury. 2001, 32: 14-23.CrossRef Krettek C, Muller M, Miclau T: Evolution of minimally invasive plate osteosynthesis (MIPO) in the femur. Injury. 2001, 32: 14-23.CrossRef
4.
go back to reference Apivatthakakul T, Chiewcharntanakit S: Minimally invasive plate osteosynthesis (MIPO) in the treatment of the femoral shaft fracture where intramedullary nailing is not indicated. Int Orthop. 2009, 33: 1119-1126. 10.1007/s00264-008-0603-2.CrossRefPubMed Apivatthakakul T, Chiewcharntanakit S: Minimally invasive plate osteosynthesis (MIPO) in the treatment of the femoral shaft fracture where intramedullary nailing is not indicated. Int Orthop. 2009, 33: 1119-1126. 10.1007/s00264-008-0603-2.CrossRefPubMed
5.
go back to reference An Z, Zeng B, He X, Chen Q, Hu S: Plating osteosynthesis of mid-distal humeral shaft fractures: minimally invasive versus conventional open reduction technique. Int Orthop. 2010, 34: 131-135. 10.1007/s00264-009-0753-x.CrossRefPubMed An Z, Zeng B, He X, Chen Q, Hu S: Plating osteosynthesis of mid-distal humeral shaft fractures: minimally invasive versus conventional open reduction technique. Int Orthop. 2010, 34: 131-135. 10.1007/s00264-009-0753-x.CrossRefPubMed
6.
go back to reference Imatani J, Noda T, Morito Y, Sato T, Hashizume H, Inoue H: Minimally invasive plate osteosynthesis for comminuted fractures of the metaphysis of the radius. J Hand Surg Br. 2005, 30: 220-225. 10.1016/j.jhsb.2004.12.009.CrossRefPubMed Imatani J, Noda T, Morito Y, Sato T, Hashizume H, Inoue H: Minimally invasive plate osteosynthesis for comminuted fractures of the metaphysis of the radius. J Hand Surg Br. 2005, 30: 220-225. 10.1016/j.jhsb.2004.12.009.CrossRefPubMed
7.
go back to reference Takada N, Otsuka T: Anatomical features of the pronator quadratus muscle related to minimally invasive plate osteosynthesis of distal radial fractures with a volar locking plate: a cadaver study. Eur Orthop Traumatol. 2011, 2: 133-136. 10.1007/s12570-011-0079-1.CrossRef Takada N, Otsuka T: Anatomical features of the pronator quadratus muscle related to minimally invasive plate osteosynthesis of distal radial fractures with a volar locking plate: a cadaver study. Eur Orthop Traumatol. 2011, 2: 133-136. 10.1007/s12570-011-0079-1.CrossRef
8.
go back to reference Tobe M, Mizutani K, Tsubuku Y, Yanagihara Y: Minimally invasive plate osteosynthesis for distal radius fractures: surgical technique. Riv Chir Mano. 2008, 3: 280-284. Tobe M, Mizutani K, Tsubuku Y, Yanagihara Y: Minimally invasive plate osteosynthesis for distal radius fractures: surgical technique. Riv Chir Mano. 2008, 3: 280-284.
10.
go back to reference McConkey MO, Schwab TD, Travlos A, Oxland TR, Goetz T: Quantification of pronator quadratus contribution to isometric pronation torque of the forearm. J Hand Surg Am. 2009, 34: 1612-1617. 10.1016/j.jhsa.2009.07.008.CrossRefPubMed McConkey MO, Schwab TD, Travlos A, Oxland TR, Goetz T: Quantification of pronator quadratus contribution to isometric pronation torque of the forearm. J Hand Surg Am. 2009, 34: 1612-1617. 10.1016/j.jhsa.2009.07.008.CrossRefPubMed
11.
go back to reference Rath S, Hung LK, Leung PC: Vascular anatomy of the pronator quadratus muscle-bone flap: a justification for its use with a distally based blood supply. J Hand Surg Am. 1990, 15: 630-636. 10.1016/S0363-5023(09)90027-2.CrossRefPubMed Rath S, Hung LK, Leung PC: Vascular anatomy of the pronator quadratus muscle-bone flap: a justification for its use with a distally based blood supply. J Hand Surg Am. 1990, 15: 630-636. 10.1016/S0363-5023(09)90027-2.CrossRefPubMed
12.
go back to reference Lee JC, Lim J, Chacha PB: The anatomical basis of the vascularized pronator quadratus pedicled bone graft. J Hand Surg Br. 1997, 22: 644-646.CrossRefPubMed Lee JC, Lim J, Chacha PB: The anatomical basis of the vascularized pronator quadratus pedicled bone graft. J Hand Surg Br. 1997, 22: 644-646.CrossRefPubMed
13.
go back to reference Sen MK, Harvey EJ: Minimally invasive plate osteosynthesis of distal radius fractures using a pronator sparing approach. Tech Hand Up Extrem Surg. 2008, 12: 2-6. 10.1097/BTH.0b013e3180cac281.CrossRefPubMed Sen MK, Harvey EJ: Minimally invasive plate osteosynthesis of distal radius fractures using a pronator sparing approach. Tech Hand Up Extrem Surg. 2008, 12: 2-6. 10.1097/BTH.0b013e3180cac281.CrossRefPubMed
Metadata
Title
Clinical study of the Pronator Quadratus muscle: anatomical features and feasibility of Pronator-Sparing Surgery
Authors
Hsien-Yi Lo
Hong-Yi Cheng
Publication date
01-12-2014
Publisher
BioMed Central
Published in
BMC Musculoskeletal Disorders / Issue 1/2014
Electronic ISSN: 1471-2474
DOI
https://doi.org/10.1186/1471-2474-15-136

Other articles of this Issue 1/2014

BMC Musculoskeletal Disorders 1/2014 Go to the issue