Abstract

The aim of the study is to determine the outcomes in patients who underwent conversion from an external fixator to an internal fixation device. This is a retrospective review of 18 patients (24 limbs) who underwent conversion from external to internal fixation. The patients had external fixators applied for traumatic bone defects or congenital deformities. Conversion to internal fixation was performed for reasons of patient dissatisfaction with external fixation, pin track sepsis, persistent non-union or refracture. The complexity of cases was graded using Paley’s level of difficulty score. Patients were either converted acutely or delayed. Internal fixation devices were either intramedullary nails or plate and screws. Outcome was regarded as excellent if the patients were fully weight-bearing and pain-free on a mechanically well-aligned limb and without need for further surgery: good if the patient required subsequent surgery to achieve union and poor if irreversible complications occurred. Acute conversions (fixator removal and introduction of internal fixation device at same surgery) were done in 19 limbs and delayed conversion (interval between fixator removal and internal fixation) in 5. In the acute group, 17 limbs (89.4 %) had at least a good outcome, 16 of these limbs had an excellent result. Two limbs (10.6 %) had a poor result and required amputation. Both cases were after acute conversion to intramedullary nails; the original presenting diagnosis was of an infected non-union of the tibia and both had Paley scores above 7. In the delayed conversion group, all limbs (100 %) had at least a good outcome, with 4 limbs (80 %) having an excellent result. The mean external fixator time was 185 days (61–370). Both the cases with poor outcomes had longer external fixation times. This series supports the practice of conversion of external fixation to internal fixation with the majority of patients attaining good results. It identifies that plate devices appear to produce fewer deep sepsis complications, as compared to intramedullary nails, particularly when the original presenting diagnosis is a septic non-union.
Literature
1.
go back to reference Paley D (1990) Problems, obstacles and complications of limb lengthening by the Ilizarov technique. Clin Orthop 250:81–104PubMed Paley D (1990) Problems, obstacles and complications of limb lengthening by the Ilizarov technique. Clin Orthop 250:81–104PubMed
2.
go back to reference Fischgrund J, Paley D, Suber C (1994) Variations affecting time to bone healing during bone lengthening. CORR 301:31–37 Fischgrund J, Paley D, Suber C (1994) Variations affecting time to bone healing during bone lengthening. CORR 301:31–37
3.
go back to reference Kristiansen LP, Steen H (1990) Lengthening of the tibia over an intramedullary nail, using the Ilizarov external fixator: major complications and slow consolidation in 9 lengthenings. Acta Orthop Scand 70:271–274CrossRef Kristiansen LP, Steen H (1990) Lengthening of the tibia over an intramedullary nail, using the Ilizarov external fixator: major complications and slow consolidation in 9 lengthenings. Acta Orthop Scand 70:271–274CrossRef
4.
go back to reference Paley D, Herzenberg JE, Paremain G, Bhave A (1997) Femoral lengthening over an intramedullary nail: a matched-case comparison with Ilizarov lengthening. J Bone Joint Surg Am 79-A:1464–1480 Paley D, Herzenberg JE, Paremain G, Bhave A (1997) Femoral lengthening over an intramedullary nail: a matched-case comparison with Ilizarov lengthening. J Bone Joint Surg Am 79-A:1464–1480
5.
go back to reference Oh C, Kim J, Choi J, Min W, Park B (2009) Limb lengthening with a submuscular locking plate. J Bone Joint Sur Br 91-B:1394–1399CrossRef Oh C, Kim J, Choi J, Min W, Park B (2009) Limb lengthening with a submuscular locking plate. J Bone Joint Sur Br 91-B:1394–1399CrossRef
6.
go back to reference Iobst CA, Dahl MT (2007) Limb lengthening with submuscular plate stabilization: a case series and description of the technique. J Pediatr Orthop 27:504–509PubMedCrossRef Iobst CA, Dahl MT (2007) Limb lengthening with submuscular plate stabilization: a case series and description of the technique. J Pediatr Orthop 27:504–509PubMedCrossRef
7.
go back to reference Simpson AH, Cole AS, Kenwright J (1999) Leg lengthening over an intramedullary nail. J Bone Joint Surg Br 81:1041–1045PubMedCrossRef Simpson AH, Cole AS, Kenwright J (1999) Leg lengthening over an intramedullary nail. J Bone Joint Surg Br 81:1041–1045PubMedCrossRef
8.
go back to reference Maurer DJ, Merkow RL, Gustilo RB (1989) Infection after intramedullary nailing of severe open tibial fractures initially treated with external fixation. J Bone Joint Surg Am 71:835–838PubMed Maurer DJ, Merkow RL, Gustilo RB (1989) Infection after intramedullary nailing of severe open tibial fractures initially treated with external fixation. J Bone Joint Surg Am 71:835–838PubMed
9.
go back to reference Linh HB, Feibel RJ (2009) Tibial lengthening over an intramedullary nail. Tech Orthop 24:279–288CrossRef Linh HB, Feibel RJ (2009) Tibial lengthening over an intramedullary nail. Tech Orthop 24:279–288CrossRef
10.
go back to reference Uysal M, Akpinar S, Cesur N, Hersekli MA, Tandogan RN (2007) Plating after nailing: technical notes and preliminary clinical experiences. Arch Ortop Trauma Surg 127:889–893CrossRef Uysal M, Akpinar S, Cesur N, Hersekli MA, Tandogan RN (2007) Plating after nailing: technical notes and preliminary clinical experiences. Arch Ortop Trauma Surg 127:889–893CrossRef
11.
go back to reference Brewster MBS, Mauffrey C, Lewis AC, Hull P (2010) Lower limb lengthening: is there a difference in the lengthening index and infection rates of lengthening with external fixators, external fixators with intramedullary nails or intramedullary nailing alone? A systematic review of the literature. Eur J Orthop Surg Traumatol 20:103–108CrossRef Brewster MBS, Mauffrey C, Lewis AC, Hull P (2010) Lower limb lengthening: is there a difference in the lengthening index and infection rates of lengthening with external fixators, external fixators with intramedullary nails or intramedullary nailing alone? A systematic review of the literature. Eur J Orthop Surg Traumatol 20:103–108CrossRef
12.
go back to reference Oh CW, Song HR, Kim JW, Choi JW, Min WK, Park BC (2009) Limb lengthening with a submuscular locking plate. JBJS Br 91-B:1394–1399 Oh CW, Song HR, Kim JW, Choi JW, Min WK, Park BC (2009) Limb lengthening with a submuscular locking plate. JBJS Br 91-B:1394–1399
13.
go back to reference Sun XT, Easwar TR, Manesh S, Ryu JH, Song SH, Kim SJ, Song HR (2011) Complications and outcomes of tibial lengthening using the Ilizarov method with or without a supplementary nail. JBJS Br 93-B:782–787 Sun XT, Easwar TR, Manesh S, Ryu JH, Song SH, Kim SJ, Song HR (2011) Complications and outcomes of tibial lengthening using the Ilizarov method with or without a supplementary nail. JBJS Br 93-B:782–787
14.
go back to reference Sabhawal S, Green S, McCarthy J, Hamby RC (2011) What’s new in limb lengthening and deformity correction? JBJS Am 93-A:213–221CrossRef Sabhawal S, Green S, McCarthy J, Hamby RC (2011) What’s new in limb lengthening and deformity correction? JBJS Am 93-A:213–221CrossRef
15.
go back to reference Kocaoglu M, Eralp L, Kilicoglu O, Burc H, Cakmak M (2004) Complications encountered during lengthening over an intramedullary nail. JBJS Am 86-A:2406–2411PubMed Kocaoglu M, Eralp L, Kilicoglu O, Burc H, Cakmak M (2004) Complications encountered during lengthening over an intramedullary nail. JBJS Am 86-A:2406–2411PubMed
16.
go back to reference Rozbruch S, Kleinman D (2008) Limb lengthening and then insertion of an intramedullary nail. CORR 466:2923–2932CrossRef Rozbruch S, Kleinman D (2008) Limb lengthening and then insertion of an intramedullary nail. CORR 466:2923–2932CrossRef
17.
go back to reference Harbacheuski R, Fragomen A, Rozbruch S (2012) Does lengthening and then plating (LAP) shorten duration of external fixation? Clin Orthop Relat Res 470:1771–1781PubMedPubMedCentralCrossRef Harbacheuski R, Fragomen A, Rozbruch S (2012) Does lengthening and then plating (LAP) shorten duration of external fixation? Clin Orthop Relat Res 470:1771–1781PubMedPubMedCentralCrossRef
Metadata
Title
Conversion of external fixation to internal fixation in a non-acute, reconstructive setting: a case series
Authors
T. Monni
F. F. Birkholtz
P. de Lange
C. H. Snyckers
Publication date
01-04-2013
Publisher
Springer Milan
Published in
Strategies in Trauma and Limb Reconstruction / Issue 1/2013
Print ISSN: 1828-8936
Electronic ISSN: 1828-8928
DOI
https://doi.org/10.1007/s11751-013-0157-8

Other articles of this Issue 1/2013

Strategies in Trauma and Limb Reconstruction 1/2013 Go to the issue