Skip to main content
Top
Published in: Clinical Orthopaedics and Related Research® 6/2012

01-06-2012 | Clinical Research

Does Lengthening and Then Plating (LAP) Shorten Duration of External Fixation?

Authors: Ryhor Harbacheuski, MD, Austin T. Fragomen, MD, S. Robert Rozbruch, MD

Published in: Clinical Orthopaedics and Related Research® | Issue 6/2012

Login to get access

Abstract

Background

Classic bone lengthening requires patients wear external fixation for the distraction and consolidation phases and there is fracture risk after frame removal. Our technique of lengthening with the Taylor Spatial FrameTM and then insertion of a locked plate allows earlier removal of the external fixator during consolidation. Plate insertion is accomplished through a clean pin-free zone avoiding contamination and before frame removal maintaining bone position.

Questions/purposes

We asked (1) whether lengthening and then plating (LAP) decrease the time for external fixation (2) how alignment and complications compare with those of the classic method.

Methods

We performed a retrospective case-matched comparison between LAP and the classic technique with 27 extremities in each group. We compared time wearing the frame, bone healing index, external fixation index, joint ROM, alignment, and complications.

Results

The time wearing the frame and external fixation index were lower in the LAP group (4.5 versus 6.2 months and 1.5 versus 2 months/cm). Deviation from normal alignment was observed in seven and six patients in the LAP and classic group, respectively. Varus malalignment in two patients in the LAP group was associated with plate breakage. The incidence of pin-tract infection was greater in the classic group (12 versus two). No deep infections occurred in the LAP group.

Conclusions

The LAP technique shortened the time patients wore the external fixator but was associated with a high incidence of varus deformity. Stronger plates may help prevent deformity and allow earlier removal of the frame.

Level of Evidence

Level III, therapeutic study (retrospective study). See the Guidelines for Authors for a complete description of levels of evidence.
Literature
1.
go back to reference Apivatthakakul T, Arpornchayanon O. Minimally invasive plate osteosynthesis (MIPO) combined with distraction osteogenesis in the treatment of bone defects: a new technique of bone transport. A report of two cases. Injury. 2002;33:460–465.PubMedCrossRef Apivatthakakul T, Arpornchayanon O. Minimally invasive plate osteosynthesis (MIPO) combined with distraction osteogenesis in the treatment of bone defects: a new technique of bone transport. A report of two cases. Injury. 2002;33:460–465.PubMedCrossRef
2.
go back to reference Aston WJ, Calder PR, Baker D, Hartley J, Hill RA. Lengthening of the congenital short femur using the Ilizarov technique: a single-surgeon series. J Bone Joint Surg Br. 2009;91:962–967.PubMedCrossRef Aston WJ, Calder PR, Baker D, Hartley J, Hill RA. Lengthening of the congenital short femur using the Ilizarov technique: a single-surgeon series. J Bone Joint Surg Br. 2009;91:962–967.PubMedCrossRef
3.
go back to reference Bhandari M, Guyatt GH, Swiontkowski MF, Tornetta P 3rd, Sprague S, Schemitsch EH. A lack of consensus in the assessment of fracture healing among orthopaedic surgeons. J Orthop Trauma. 2002;16:562–566.PubMedCrossRef Bhandari M, Guyatt GH, Swiontkowski MF, Tornetta P 3rd, Sprague S, Schemitsch EH. A lack of consensus in the assessment of fracture healing among orthopaedic surgeons. J Orthop Trauma. 2002;16:562–566.PubMedCrossRef
4.
go back to reference Blondel B, Launay F, Glard Y, Jacopin S, Jouve JL, Bollini G. Limb lengthening and deformity correction in children using hexapodal external fixation: preliminary results for 36 cases. Orthop Traumatol Surg Res. 2009;95:425–430.PubMedCrossRef Blondel B, Launay F, Glard Y, Jacopin S, Jouve JL, Bollini G. Limb lengthening and deformity correction in children using hexapodal external fixation: preliminary results for 36 cases. Orthop Traumatol Surg Res. 2009;95:425–430.PubMedCrossRef
5.
go back to reference Catagni MA, Lovisetti L, Guerreschi F, Combi A, Ottaviani G. Cosmetic bilateral leg lengthening: experience of 54 cases. J Bone Joint Surg Br. 2005;87:1402–1405.PubMedCrossRef Catagni MA, Lovisetti L, Guerreschi F, Combi A, Ottaviani G. Cosmetic bilateral leg lengthening: experience of 54 cases. J Bone Joint Surg Br. 2005;87:1402–1405.PubMedCrossRef
6.
go back to reference Corrales LA, Morshed S, Bhandari M, Miclau T 3rd. Variability in the assessment of fracture-healing in orthopaedic trauma studies. J Bone Joint Surg Am. 2008;90:1862–1868.PubMedCrossRef Corrales LA, Morshed S, Bhandari M, Miclau T 3rd. Variability in the assessment of fracture-healing in orthopaedic trauma studies. J Bone Joint Surg Am. 2008;90:1862–1868.PubMedCrossRef
7.
go back to reference Danziger MB, Kumar A, DeWeese J. Fractures after femoral lengthening using the Ilizarov method. J Pediatr Orthop. 1995;15:220–223.PubMed Danziger MB, Kumar A, DeWeese J. Fractures after femoral lengthening using the Ilizarov method. J Pediatr Orthop. 1995;15:220–223.PubMed
8.
go back to reference Endo H, Asaumi K, Mitani S, Noda T, Minagawa H, Tetsunaga T, Ozaki T. The minimally invasive plate osteosynthesis (MIPO) technique with a locking compression plate for femoral lengthening. Acta Med Okayama. 2008;62:333–339.PubMed Endo H, Asaumi K, Mitani S, Noda T, Minagawa H, Tetsunaga T, Ozaki T. The minimally invasive plate osteosynthesis (MIPO) technique with a locking compression plate for femoral lengthening. Acta Med Okayama. 2008;62:333–339.PubMed
9.
go back to reference Gantsoudes GD, Fragomen AT, Rozbruch SR. Intraoperative measurement of mounting parameters for the Taylor Spatial Frame. J Orthop Trauma. 2010;24:258–262.PubMedCrossRef Gantsoudes GD, Fragomen AT, Rozbruch SR. Intraoperative measurement of mounting parameters for the Taylor Spatial Frame. J Orthop Trauma. 2010;24:258–262.PubMedCrossRef
10.
go back to reference Gereli A, Nalbantoglu U, Kocaoglu B, Turkmen M. Comparison of palmar locking plate and K-wire augmented external fixation for intra-articular and comminuted distal radius fractures. Acta Orthop Traumatol Turc. 2010;44:212–219.PubMedCrossRef Gereli A, Nalbantoglu U, Kocaoglu B, Turkmen M. Comparison of palmar locking plate and K-wire augmented external fixation for intra-articular and comminuted distal radius fractures. Acta Orthop Traumatol Turc. 2010;44:212–219.PubMedCrossRef
11.
go back to reference Green SA. Pin and wire technique for external fixation. Instr Course Lect. 1995;44:487–493.PubMed Green SA. Pin and wire technique for external fixation. Instr Course Lect. 1995;44:487–493.PubMed
12.
go back to reference Ilizarov GA. The tension-stress effect on the genesis and growth of tissues: Part II. The influence of the rate and frequency of distraction. Clin Orthop Relat Res. 1989;239:263–285.PubMed Ilizarov GA. The tension-stress effect on the genesis and growth of tissues: Part II. The influence of the rate and frequency of distraction. Clin Orthop Relat Res. 1989;239:263–285.PubMed
13.
go back to reference Ilizarov GA. Transosseous Osteosynthesis: Theoretical and Clinical Aspects of the Regeneration and Growth of Tissue. New York, NY: Springer-Verlag; 1992. Ilizarov GA. Transosseous Osteosynthesis: Theoretical and Clinical Aspects of the Regeneration and Growth of Tissue. New York, NY: Springer-Verlag; 1992.
14.
go back to reference Iobst CA, Dahl MT. Limb lengthening with submuscular plate stabilization: a case series and description of the technique. J Pediatr Orthop. 2007;27:504–509.PubMedCrossRef Iobst CA, Dahl MT. Limb lengthening with submuscular plate stabilization: a case series and description of the technique. J Pediatr Orthop. 2007;27:504–509.PubMedCrossRef
15.
go back to reference Kristiansen LP, Steen H, Reikeras O. No difference in tibial lengthening index by use of Taylor spatial frame or Ilizarov external fixator. Acta Orthop. 2006;77:772–777.PubMedCrossRef Kristiansen LP, Steen H, Reikeras O. No difference in tibial lengthening index by use of Taylor spatial frame or Ilizarov external fixator. Acta Orthop. 2006;77:772–777.PubMedCrossRef
16.
go back to reference Lerner A, Chezar A, Haddad M, Kaufman H, Rozen N, Stein H. Complications encountered while using thin-wire-hybrid-external fixation modular frames for fracture fixation: a retrospective clinical analysis and possible support for “Damage Control Orthopaedic Surgery”. Injury. 2005;36:590–598.PubMedCrossRef Lerner A, Chezar A, Haddad M, Kaufman H, Rozen N, Stein H. Complications encountered while using thin-wire-hybrid-external fixation modular frames for fracture fixation: a retrospective clinical analysis and possible support for “Damage Control Orthopaedic Surgery”. Injury. 2005;36:590–598.PubMedCrossRef
17.
go back to reference Lie CW, Chow W. Limb lengthening in short-stature patients using monolateral and circular external fixators. Hong Kong Med J. 2009;15:280–284.PubMed Lie CW, Chow W. Limb lengthening in short-stature patients using monolateral and circular external fixators. Hong Kong Med J. 2009;15:280–284.PubMed
18.
go back to reference Matsubara H, Tsuchiya H, Sakurakichi K, Watanabe K, Tomita K. Deformity correction and lengthening of lower legs with an external fixator. Int Orthop. 2006;30:550–554.PubMedCrossRef Matsubara H, Tsuchiya H, Sakurakichi K, Watanabe K, Tomita K. Deformity correction and lengthening of lower legs with an external fixator. Int Orthop. 2006;30:550–554.PubMedCrossRef
19.
go back to reference McClelland D, Thomas PB, Bancroft G, Moorcraft CI. Fracture healing assessment comparing stiffness measurements using radiographs. Clin Orthop Relat Res. 2007;457:214–219.PubMed McClelland D, Thomas PB, Bancroft G, Moorcraft CI. Fracture healing assessment comparing stiffness measurements using radiographs. Clin Orthop Relat Res. 2007;457:214–219.PubMed
20.
go back to reference Nakase T, Kitano M, Kawai H, Ueda T, Higuchi C, Hamada M, Yoshikawa H. Distraction osteogenesis for correction of three-dimensional deformities with shortening of lower limbs by Taylor Spatial Frame. Arch Orthop Trauma Surg. 2009;129:1197–1201.PubMedCrossRef Nakase T, Kitano M, Kawai H, Ueda T, Higuchi C, Hamada M, Yoshikawa H. Distraction osteogenesis for correction of three-dimensional deformities with shortening of lower limbs by Taylor Spatial Frame. Arch Orthop Trauma Surg. 2009;129:1197–1201.PubMedCrossRef
21.
go back to reference O’Carrigan T, Paley D, Herzenberg JE. Obstacles in limb lengthening: fractures. In: Rozbruch SR, Ilizarov S, eds. Limb Lengthening and Reconstruction Surgery. New York, NY: Informa Healthcare; 2007:675–679. O’Carrigan T, Paley D, Herzenberg JE. Obstacles in limb lengthening: fractures. In: Rozbruch SR, Ilizarov S, eds. Limb Lengthening and Reconstruction Surgery. New York, NY: Informa Healthcare; 2007:675–679.
22.
go back to reference Oh CW, Shetty GM, Song HR, Kyung HS, Oh JK, Min WK, Lee BW, Park BC. Submuscular plating after distraction osteogenesis in children. J Pediatr Orthop B. 2008;17:265–269.PubMedCrossRef Oh CW, Shetty GM, Song HR, Kyung HS, Oh JK, Min WK, Lee BW, Park BC. Submuscular plating after distraction osteogenesis in children. J Pediatr Orthop B. 2008;17:265–269.PubMedCrossRef
23.
go back to reference Paley D. Problems, obstacles, and complications of limb lengthening by the Ilizarov technique. Clin Orthop Relat Res. 1990;250:81–104.PubMed Paley D. Problems, obstacles, and complications of limb lengthening by the Ilizarov technique. Clin Orthop Relat Res. 1990;250:81–104.PubMed
24.
go back to reference Paley D, Herzenberg JE, Paremain G, Bhave A. Femoral lengthening over an intramedullary nail: a matched-case comparison with Ilizarov femoral lengthening. J Bone Joint Surg Am. 1997;79:1464–1480.PubMed Paley D, Herzenberg JE, Paremain G, Bhave A. Femoral lengthening over an intramedullary nail: a matched-case comparison with Ilizarov femoral lengthening. J Bone Joint Surg Am. 1997;79:1464–1480.PubMed
25.
go back to reference Rozbruch SR, Fragomen AT, Ilizarov S. Correction of tibial deformity with use of the Ilizarov-Taylor spatial frame. J Bone Joint Surg Am. 2006;88(suppl 4):156–174.PubMedCrossRef Rozbruch SR, Fragomen AT, Ilizarov S. Correction of tibial deformity with use of the Ilizarov-Taylor spatial frame. J Bone Joint Surg Am. 2006;88(suppl 4):156–174.PubMedCrossRef
26.
go back to reference Rozbruch SR, Kleinman D, Fragomen AT, Ilizarov S. Limb lengthening and then insertion of an intramedullary nail: a case-matched comparison. Clin Orthop Relat Res. 2008;466:2923–2932.PubMedCrossRef Rozbruch SR, Kleinman D, Fragomen AT, Ilizarov S. Limb lengthening and then insertion of an intramedullary nail: a case-matched comparison. Clin Orthop Relat Res. 2008;466:2923–2932.PubMedCrossRef
27.
go back to reference Rozbruch SR, Segal K, Ilizarov S, Fragomen AT, Ilizarov G. Does the Taylor Spatial Frame accurately correct tibial deformities? Clin Orthop Relat Res. 2010;468:1352–1361.PubMedCrossRef Rozbruch SR, Segal K, Ilizarov S, Fragomen AT, Ilizarov G. Does the Taylor Spatial Frame accurately correct tibial deformities? Clin Orthop Relat Res. 2010;468:1352–1361.PubMedCrossRef
29.
go back to reference Song HR, Myrboh V, Oh CW, Lee ST, Lee SH. Tibial lengthening and concomitant foot deformity correction in 14 patients with permanent deformity after poliomyelitis. Acta Orthop. 2005;76:261–269.PubMedCrossRef Song HR, Myrboh V, Oh CW, Lee ST, Lee SH. Tibial lengthening and concomitant foot deformity correction in 14 patients with permanent deformity after poliomyelitis. Acta Orthop. 2005;76:261–269.PubMedCrossRef
30.
go back to reference Temple J, Santy J. Pin site care for preventing infections associated with external bone fixators and pins. Cochrane Database Syst Rev. 2004;1:CD004551. Temple J, Santy J. Pin site care for preventing infections associated with external bone fixators and pins. Cochrane Database Syst Rev. 2004;1:CD004551.
31.
go back to reference Uysal M, Akpinar S, Cesur N, Hersekli MA, Tandogan RN. Plating after lengthening (PAL): technical notes and preliminary clinical experiences. Arch Orthop Trauma Surg. 2007;127:889–893.PubMedCrossRef Uysal M, Akpinar S, Cesur N, Hersekli MA, Tandogan RN. Plating after lengthening (PAL): technical notes and preliminary clinical experiences. Arch Orthop Trauma Surg. 2007;127:889–893.PubMedCrossRef
32.
go back to reference Wagner H. Operative lengthening of the femur. Clin Orthop Relat Res. 1978;136:125–142.PubMed Wagner H. Operative lengthening of the femur. Clin Orthop Relat Res. 1978;136:125–142.PubMed
33.
go back to reference Wu CC, Lee ZL, Wu CC, Lee ZL. Speeded gradual lengthening and secondary angled blade plate stabilisation for proximal tibial shaft non-union with shortening. Int Orthop. 2008;32:693–696.PubMedCrossRef Wu CC, Lee ZL, Wu CC, Lee ZL. Speeded gradual lengthening and secondary angled blade plate stabilisation for proximal tibial shaft non-union with shortening. Int Orthop. 2008;32:693–696.PubMedCrossRef
Metadata
Title
Does Lengthening and Then Plating (LAP) Shorten Duration of External Fixation?
Authors
Ryhor Harbacheuski, MD
Austin T. Fragomen, MD
S. Robert Rozbruch, MD
Publication date
01-06-2012
Publisher
Springer-Verlag
Published in
Clinical Orthopaedics and Related Research® / Issue 6/2012
Print ISSN: 0009-921X
Electronic ISSN: 1528-1132
DOI
https://doi.org/10.1007/s11999-011-2178-2

Other articles of this Issue 6/2012

Clinical Orthopaedics and Related Research® 6/2012 Go to the issue