Skip to main content
Top
Published in: Molecular Imaging and Biology 2/2009

01-03-2009 | Research Article

Multimodality Rodent Imaging Chambers for Use Under Barrier Conditions with Gas Anesthesia

Authors: Chris Suckow, Claudia Kuntner, Patrick Chow, Robert Silverman, Arion Chatziioannou, David Stout

Published in: Molecular Imaging and Biology | Issue 2/2009

Login to get access

Abstract

Purpose

The ability to reproducibly and repeatedly image rodents in noninvasive imaging systems, such as small-animal positron emission tomography (PET) and computed tomography (CT), requires a reliable method for anesthetizing, positioning, and heating animals in a simple reproducible manner. In this paper, we demonstrate that mice and rats can be reproducibly and repeatedly imaged using an imaging chamber designed to be rigidly mounted on multiple imaging systems.

Procedures

Mouse and rat imaging chambers were made of acrylic plastic and aluminum. MicroCT scans were used to evaluate the positioning reproducibility of the chambers in multimodality and longitudinal imaging studies. The ability of the chambers to maintain mouse and rat body temperatures while anesthetized with gas anesthesia was also evaluated.

Results

Both the mouse and rat imaging chambers were able to reproducibly position the animals in the imaging systems with a small degree of error. Placement of the mouse in the mouse imaging chamber resulted in a mean distance of 0.23 mm per reference point in multimodality studies, whereas for longitudinal studies the mean difference was 1.11 mm. The rat chamber resulted in a mean difference of 0.46 mm in multimodality studies and a mean difference of 4.31 mm in longitudinal studies per reference point. The chambers maintained rodent body temperatures at the set point temperature of 38°C.

Conclusions

The rodent imaging chambers were able to reproducibly position rodents in tomographs with a small degree of variability and were compatible with routine use. The embedded anesthetic line and heating system was capable of maintaining the rodent’s temperature and anesthetic state, thereby enhancing rodent health and improving data collection reliability.
Literature
1.
go back to reference Croy AC, DiSanto JP, Manz M et al (2007) Mouse models of immunodeficiency. In: Fox JG, Barthold SW, Davisson MT et al (eds) The mouse in biomedical research. Academic, New York, pp 275–289CrossRef Croy AC, DiSanto JP, Manz M et al (2007) Mouse models of immunodeficiency. In: Fox JG, Barthold SW, Davisson MT et al (eds) The mouse in biomedical research. Academic, New York, pp 275–289CrossRef
2.
go back to reference Fueger BJ et al (2006) Impact of animal handling on the results of 18F-FDG PET studies in mice. J Nucl Med 47:999–1006PubMed Fueger BJ et al (2006) Impact of animal handling on the results of 18F-FDG PET studies in mice. J Nucl Med 47:999–1006PubMed
3.
go back to reference Chow PL, Stout DB, Komisopoulou E, Chatziioannou AF (2006) A method of image registration for small animal, multi-modality imaging. Phys Med Biol 51:379–390PubMedCrossRef Chow PL, Stout DB, Komisopoulou E, Chatziioannou AF (2006) A method of image registration for small animal, multi-modality imaging. Phys Med Biol 51:379–390PubMedCrossRef
4.
go back to reference Stout DB et al (2005) Small animal imaging center design: the facility at the UCLA Crump institute for molecular imaging. Mol Imaging Biol 7:393–402PubMedCrossRef Stout DB et al (2005) Small animal imaging center design: the facility at the UCLA Crump institute for molecular imaging. Mol Imaging Biol 7:393–402PubMedCrossRef
5.
go back to reference Stout D, Lawson TP, Silverman RW, Chatziioannou AF (2001) Immuno-isolated imaging of SCID and nude mice in microPET. Proceedings of the Annual Conference of the Academy of Molecular Imaging Stout D, Lawson TP, Silverman RW, Chatziioannou AF (2001) Immuno-isolated imaging of SCID and nude mice in microPET. Proceedings of the Annual Conference of the Academy of Molecular Imaging
6.
go back to reference Bahadur AN et al (2007) Multimodality chamber for coregistered anatomical and molecular imaging of small animals. Lab Anim (NY) 36:29–35CrossRef Bahadur AN et al (2007) Multimodality chamber for coregistered anatomical and molecular imaging of small animals. Lab Anim (NY) 36:29–35CrossRef
7.
go back to reference Rubins DJ, Meadors AK, Yee S, Melega WP, Cherry SR (2001) Evaluation of a stereotactic frame for repositioning of the rat brain in serial positron emission tomography imaging studies. J Neurosci Methods 107:63–70PubMedCrossRef Rubins DJ, Meadors AK, Yee S, Melega WP, Cherry SR (2001) Evaluation of a stereotactic frame for repositioning of the rat brain in serial positron emission tomography imaging studies. J Neurosci Methods 107:63–70PubMedCrossRef
8.
go back to reference Herschman HR (2004) PET reporter genes for noninvasive imaging of gene therapy, cell tracking and transgenic analysis. Crit Rev Oncol Hematol 51:191–204PubMedCrossRef Herschman HR (2004) PET reporter genes for noninvasive imaging of gene therapy, cell tracking and transgenic analysis. Crit Rev Oncol Hematol 51:191–204PubMedCrossRef
9.
go back to reference Hendrich H, Horst M (2004) Housing and maintenance. In: Hendrich H (ed) The laboratory mouse. Academic, New York, pp 395–408CrossRef Hendrich H, Horst M (2004) Housing and maintenance. In: Hendrich H (ed) The laboratory mouse. Academic, New York, pp 395–408CrossRef
10.
go back to reference Chatziioannou AF (2002) Molecular imaging of small animals with dedicated PET tomographs. Eur J Nucl Med Mol Imaging 29:98–114PubMedCrossRef Chatziioannou AF (2002) Molecular imaging of small animals with dedicated PET tomographs. Eur J Nucl Med Mol Imaging 29:98–114PubMedCrossRef
11.
go back to reference Jacoby RO, Fox JG, Davisson M (2002) Biology and diseases of mice. In: Fox JG, Anderson LC, Loew FM et al (eds) Laboratory animal medicine. 2nd edn. Academic, New York, pp 35–120 Jacoby RO, Fox JG, Davisson M (2002) Biology and diseases of mice. In: Fox JG, Anderson LC, Loew FM et al (eds) Laboratory animal medicine. 2nd edn. Academic, New York, pp 35–120
12.
go back to reference Deroose CM et al (2007) Multimodality imaging of tumor xenografts and metastases in mice with combined small-animal PET, small-animal CT, and bioluminescence imaging. J Nucl Med 48:295–303PubMed Deroose CM et al (2007) Multimodality imaging of tumor xenografts and metastases in mice with combined small-animal PET, small-animal CT, and bioluminescence imaging. J Nucl Med 48:295–303PubMed
13.
go back to reference Wagenaar DJ, Kapusta M, Li J, Patt BE (2006) Rationale for the combination of nuclear medicine with magnetic resonance for pre-clinical imaging. Technol Cancer Res Treat 5:343–350PubMed Wagenaar DJ, Kapusta M, Li J, Patt BE (2006) Rationale for the combination of nuclear medicine with magnetic resonance for pre-clinical imaging. Technol Cancer Res Treat 5:343–350PubMed
14.
go back to reference Hsieh J et al (2004) A novel reconstruction algorithm to extend the CT scan field-of-view. Med Phys 31:2385–2391PubMedCrossRef Hsieh J et al (2004) A novel reconstruction algorithm to extend the CT scan field-of-view. Med Phys 31:2385–2391PubMedCrossRef
15.
go back to reference Beattie BJ et al (2007) Multimodality registration without a dedicated multimodality scanner. Mol Imaging 6:108–120PubMed Beattie BJ et al (2007) Multimodality registration without a dedicated multimodality scanner. Mol Imaging 6:108–120PubMed
16.
go back to reference Zanzonico P et al (2006) Animal-specific positioning molds for registration of repeat imaging studies: comparative microPET imaging of F18-labeled fluoro-deoxyglucose and fluoro-misonidazole in rodent tumors. Nucl Med Biol 33:65–70PubMedCrossRef Zanzonico P et al (2006) Animal-specific positioning molds for registration of repeat imaging studies: comparative microPET imaging of F18-labeled fluoro-deoxyglucose and fluoro-misonidazole in rodent tumors. Nucl Med Biol 33:65–70PubMedCrossRef
17.
go back to reference Kastenmayer RJ, Perdue KA (2007) Variation in organ volumes of matched BALB/c mice by microcomputed tomography analysis. J Am Assoc Lab Anim Sci 46:7–12PubMed Kastenmayer RJ, Perdue KA (2007) Variation in organ volumes of matched BALB/c mice by microcomputed tomography analysis. J Am Assoc Lab Anim Sci 46:7–12PubMed
Metadata
Title
Multimodality Rodent Imaging Chambers for Use Under Barrier Conditions with Gas Anesthesia
Authors
Chris Suckow
Claudia Kuntner
Patrick Chow
Robert Silverman
Arion Chatziioannou
David Stout
Publication date
01-03-2009
Publisher
Springer-Verlag
Published in
Molecular Imaging and Biology / Issue 2/2009
Print ISSN: 1536-1632
Electronic ISSN: 1860-2002
DOI
https://doi.org/10.1007/s11307-008-0165-0

Other articles of this Issue 2/2009

Molecular Imaging and Biology 2/2009 Go to the issue