Skip to main content
Top
Published in: International Urology and Nephrology 4/2011

01-12-2011 | Nephrology – Original Paper

Body composition monitor measurement technique for the detection of volume status in peritoneal dialysis patients: the effect of abdominal fullness

Authors: Savas Sipahi, Ender Hur, Saadet Demirtas, Ibrahim Kocayigit, Devrim Bozkurt, Ali Tamer, Huseyin Gunduz, Soner Duman

Published in: International Urology and Nephrology | Issue 4/2011

Login to get access

Abstract

Background

Bioimpedance spectroscopy (BIS) is used to assess volume status in peritoneal dialysis (PD) patients. However, it is proposed that it may be troubling in patients with abnormal fluid distribution and body geometry. It is not clear whether having an empty abdomen or not interferes with the BIS results and its relation with echocardiographic findings in PD patients.

Methods

Twenty-five prevalent PD patients were enrolled. Echocardiography and body composition analysis using BIS technique (50 frequencies, the Body Composition Monitor, BCM) were performed. Overhydration (OH), extracellular water (ECW) in liters and OH/ECW ratio were used as volume status indices. Differences in volume and echocardiographic findings, in patients with empty and with full abdomen, and their correlations with echocardiographic parameters were investigated.

Results

Mean age and PD duration were 61 ± 2.5 years and 42 ± 33 months, respectively. Sixty-four percent were male and 24% were diabetic. Mean left ventricular mass index (LVMi) was 131 ± 43 g/m , 2 mean left atrium diameter (LA) was 4.1 ± 0.1 cm, mean left ventricular ejection fraction (EF) was 64 ± 10%. Mean OH in patients with full abdomen were 1.67 ± 1.51 L and 1.68 ± 1.48 L, depending on the inclusion or exclusion of the dialysate volume, respectively. In patients with an empty abdomen, mean OHs were 2.12 ± 1.76 L and 1.91 ± 1.56 L, depending on the inclusion or exclusion of the dialysate volume. BIS measurements with an empty, but not with a full abdomen, was related to the echocardiographic parameters.

Conclusion

BIS is a reliable method to evaluate volume status in PD patients. BIS performed after peritoneal equilibration test with an empty abdomen, better reflects overhydration and is related to echocardiographic parameters.
Literature
1.
go back to reference Qureshi AR, Alvestrand A, Divino-Filho JC et al (2002) Inflammation, malnutrition, and cardiac disease as predictors of mortality in hemodialysis patients. J Am Soc Nephrol 13:28–36 Qureshi AR, Alvestrand A, Divino-Filho JC et al (2002) Inflammation, malnutrition, and cardiac disease as predictors of mortality in hemodialysis patients. J Am Soc Nephrol 13:28–36
2.
go back to reference Brown EA, Davies SJ, Rutherford P et al (2003) Survival of functionally anuric patients on automated peritoneal dialysis: the European APD outcome study. J Am Soc Nephrol 14:2948–2957PubMedCrossRef Brown EA, Davies SJ, Rutherford P et al (2003) Survival of functionally anuric patients on automated peritoneal dialysis: the European APD outcome study. J Am Soc Nephrol 14:2948–2957PubMedCrossRef
3.
go back to reference Konings CJ, Kooman JP, Schonck M et al (2002) Assessment of fluid status in peritoneal dialysis patients. Perit Dial Int 22:683–692PubMed Konings CJ, Kooman JP, Schonck M et al (2002) Assessment of fluid status in peritoneal dialysis patients. Perit Dial Int 22:683–692PubMed
4.
go back to reference Cheng LT, Gao YL, Qin C et al (2008) Volume overhydration is related to endothelial dysfunction in continuous ambulatory peritoneal dialysis patients. Perit Dial Int 28:397–402PubMed Cheng LT, Gao YL, Qin C et al (2008) Volume overhydration is related to endothelial dysfunction in continuous ambulatory peritoneal dialysis patients. Perit Dial Int 28:397–402PubMed
5.
go back to reference Yang JH, Cheng LT, Gu Y et al (2008) Volume overload in patients treated with continuous ambulatory peritoneal dialysis associated with reduced circadian blood pressure variation. Blood Purif 26:399–403PubMedCrossRef Yang JH, Cheng LT, Gu Y et al (2008) Volume overload in patients treated with continuous ambulatory peritoneal dialysis associated with reduced circadian blood pressure variation. Blood Purif 26:399–403PubMedCrossRef
6.
go back to reference Paniagua R, Amato D, Correa-Rotter R et al (2000) Correlation between peritoneal equilibration test and dialysis adequacy and transport test, for peritoneal transport type characterization. Mexican nephrology collaborative study group. Perit Dial Int 20:53–59PubMed Paniagua R, Amato D, Correa-Rotter R et al (2000) Correlation between peritoneal equilibration test and dialysis adequacy and transport test, for peritoneal transport type characterization. Mexican nephrology collaborative study group. Perit Dial Int 20:53–59PubMed
7.
go back to reference Leunissen KM, Kouw P, Kooman JP et al (1993) New techniques to determine fluid status in hemodialyzed patients. Kidney Int Suppl. 41:S50–S56PubMed Leunissen KM, Kouw P, Kooman JP et al (1993) New techniques to determine fluid status in hemodialyzed patients. Kidney Int Suppl. 41:S50–S56PubMed
8.
go back to reference Chamney PW, Kramer M, Rode C et al (2002) A new technique for establishing dry weight in hemodialysis patients via whole body bioimpedance. Kidney Int 61:2250–2258PubMedCrossRef Chamney PW, Kramer M, Rode C et al (2002) A new technique for establishing dry weight in hemodialysis patients via whole body bioimpedance. Kidney Int 61:2250–2258PubMedCrossRef
9.
go back to reference Chamney PW, Wabel P, Moissl UM et al (2007) A whole-body model to distinguish excess fluid from the hydration of major body tissues. Am J Clin Nutr 85:80–89PubMed Chamney PW, Wabel P, Moissl UM et al (2007) A whole-body model to distinguish excess fluid from the hydration of major body tissues. Am J Clin Nutr 85:80–89PubMed
10.
go back to reference Wizemann V, Wabel P, Chamney P et al (2009) The mortality risk of overhydration in haemodialysis patients. Nephrol Dial Transplant 24:1574–1579PubMedCrossRef Wizemann V, Wabel P, Chamney P et al (2009) The mortality risk of overhydration in haemodialysis patients. Nephrol Dial Transplant 24:1574–1579PubMedCrossRef
11.
go back to reference Zhu F, Hoenich NA, Kaysen G, Ronco C, Schneditz D, Murphy L, Santacroce S, Pangilinan A, Gotch F, Levin NW (2003) Measurement of intraperitoneal volume by segmental bioimpedance analysis during peritoneal dialysis. Am J Kidney Dis 42(1):167–172PubMedCrossRef Zhu F, Hoenich NA, Kaysen G, Ronco C, Schneditz D, Murphy L, Santacroce S, Pangilinan A, Gotch F, Levin NW (2003) Measurement of intraperitoneal volume by segmental bioimpedance analysis during peritoneal dialysis. Am J Kidney Dis 42(1):167–172PubMedCrossRef
12.
go back to reference Gardin JM, Adams DB, Douglas PS et al (2002) American society of echocardiography. Recommendations for a standardized report for adult transthoracic echocardiography: a report from the American society of echocardiography’s nomenclature and standards committee and task force for a standardized echocardiography report. J Am Soc Echocardiogr 15(3):275–290PubMedCrossRef Gardin JM, Adams DB, Douglas PS et al (2002) American society of echocardiography. Recommendations for a standardized report for adult transthoracic echocardiography: a report from the American society of echocardiography’s nomenclature and standards committee and task force for a standardized echocardiography report. J Am Soc Echocardiogr 15(3):275–290PubMedCrossRef
13.
go back to reference Devereux RB, Reichek N (1977) Echocardiographic determination of left ventricular mass in man. Anatomic validation of the method. Circulation 55(4):613–618PubMed Devereux RB, Reichek N (1977) Echocardiographic determination of left ventricular mass in man. Anatomic validation of the method. Circulation 55(4):613–618PubMed
14.
go back to reference Levy D, Garrison RJ, Savage DD, Kannel WB, Castelli WP (1990) Prognostic implications of echocardiographically determined left ventricular mass in the Framingham heart study. N Engl J Med 27:1561–1566CrossRef Levy D, Garrison RJ, Savage DD, Kannel WB, Castelli WP (1990) Prognostic implications of echocardiographically determined left ventricular mass in the Framingham heart study. N Engl J Med 27:1561–1566CrossRef
15.
go back to reference Plum J, Schoenicke G, Kleophas W et al (2001) Comparison of body fluid distribution between chronic haemodialysis and peritoneal dialysis patients as assessed by biophysical and biochemical methods. Nephrol Dial Transplant 16:2378–2385PubMedCrossRef Plum J, Schoenicke G, Kleophas W et al (2001) Comparison of body fluid distribution between chronic haemodialysis and peritoneal dialysis patients as assessed by biophysical and biochemical methods. Nephrol Dial Transplant 16:2378–2385PubMedCrossRef
16.
go back to reference Cox-Reijven PL, Kooman JP, Soeters PB, van der Sande FM, Leunissen KM (2001) Role of bioimpedance spectroscopy in assessment of body water compartments in hemodialysis patients. Am J Kidney Dis 38:832–838PubMedCrossRef Cox-Reijven PL, Kooman JP, Soeters PB, van der Sande FM, Leunissen KM (2001) Role of bioimpedance spectroscopy in assessment of body water compartments in hemodialysis patients. Am J Kidney Dis 38:832–838PubMedCrossRef
17.
go back to reference Asghar RB, Green S, Engel B, Davies SJ (2004) Relationship of demographic, dietary, and clinical factors to the hydration status of patients on peritoneal dialysis. Perit Dial Int 24:231–239PubMed Asghar RB, Green S, Engel B, Davies SJ (2004) Relationship of demographic, dietary, and clinical factors to the hydration status of patients on peritoneal dialysis. Perit Dial Int 24:231–239PubMed
18.
go back to reference Earthman C, Traughber D, Dobratz J, Howell W (2007) Bioimpedance spectroscopy for clinical assessment of fluid distribution and body cell mass. Nutr Clin Pract 22(4):389–405PubMedCrossRef Earthman C, Traughber D, Dobratz J, Howell W (2007) Bioimpedance spectroscopy for clinical assessment of fluid distribution and body cell mass. Nutr Clin Pract 22(4):389–405PubMedCrossRef
19.
go back to reference Lindley E, Devine Y, Hall L et al (2005) A ward-based procedure for assessment of fluid status in peritoneal dialysis patients using bioimpedance spectroscopy. Perit Dial Int 25(Suppl 3):S46–S48PubMed Lindley E, Devine Y, Hall L et al (2005) A ward-based procedure for assessment of fluid status in peritoneal dialysis patients using bioimpedance spectroscopy. Perit Dial Int 25(Suppl 3):S46–S48PubMed
Metadata
Title
Body composition monitor measurement technique for the detection of volume status in peritoneal dialysis patients: the effect of abdominal fullness
Authors
Savas Sipahi
Ender Hur
Saadet Demirtas
Ibrahim Kocayigit
Devrim Bozkurt
Ali Tamer
Huseyin Gunduz
Soner Duman
Publication date
01-12-2011
Publisher
Springer Netherlands
Published in
International Urology and Nephrology / Issue 4/2011
Print ISSN: 0301-1623
Electronic ISSN: 1573-2584
DOI
https://doi.org/10.1007/s11255-011-9977-y

Other articles of this Issue 4/2011

International Urology and Nephrology 4/2011 Go to the issue
Live Webinar | 27-06-2024 | 18:00 (CEST)

Keynote webinar | Spotlight on medication adherence

Live: Thursday 27th June 2024, 18:00-19:30 (CEST)

WHO estimates that half of all patients worldwide are non-adherent to their prescribed medication. The consequences of poor adherence can be catastrophic, on both the individual and population level.

Join our expert panel to discover why you need to understand the drivers of non-adherence in your patients, and how you can optimize medication adherence in your clinics to drastically improve patient outcomes.

Prof. Kevin Dolgin
Prof. Florian Limbourg
Prof. Anoop Chauhan
Developed by: Springer Medicine
Obesity Clinical Trial Summary

At a glance: The STEP trials

A round-up of the STEP phase 3 clinical trials evaluating semaglutide for weight loss in people with overweight or obesity.

Developed by: Springer Medicine